Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial-velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial-velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm s{sup −1}, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial-velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser fRequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on the radial-velocity precision due to pixel-position nonuniformities and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter–McLaughlin effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Low cost automated precise time measurement system

The Aerospace Guidance and Metrology Center (AGMC) has the responsibility for the dissemination of Precise Time and Time Interval (PTTI) to Air Force timing systems requiring microsecond time. In order to maintain traceability to the USNO Master Clock in Washington D.C., and accomplish efficient logging of time and frequency data on individual precision clocks, a simple automatic means of acquiring precise time has been devised. The Automatic Time Interval Measurement System (ATIMS) consists of a minicomputer (8K Memory), teletype terminal, electronic counter, Loran C receiver, time base generator and locally-manufactured relay matrix panel. During the measurement process, the computer controls the relay matrix which selects for comparison 13 atomic clocks against a reference clock and the reference versus Loran C. Through use of the system teletype, the operator is able to set the system clock (hours, minutes and seconds), examine and/or modify all clock data and constants, and set measurement intervals. This is done in a conversational manner. A logic flow diagram, system schematic, source listing and software components are included in the presentation.

Alpert, A.↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f

Mass Spectrometry↗

The NuMI Flux Prediction at ICARUS

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment seeking to probe fundamental symmetries within the structure of the Pontecorvo-Maki-Nakagawa-Sakata (PMNS) mixing matrix, and perform precision measurements its parameters including the neutrino mass ordering via the sign of $\Delta m^2_{31}$, and the charge-parity violating phase, $\delta_{CP}$. To make these measurements with high precision, DUNE will require external $\nu$-Ar scattering cross section data as a crucial input to the oscillation fit. Imaging Cosmic And Rare Underground Signals (ICARUS) is a 476 t liquid argon neutrino detector located at Fermi National Accelerator Laboratory (FNAL) where it is serving as the far detector for the Short-Baseline Neutrino (SBN) program along the Booster Neutrino Beam (BNB) axis. ICARUS additionally lies 795 m downstream and 100.1 mrad off-axis of the Neutrinos at the Main Injector (NuMI) neutrino beam. From this position, ICARUS is exposed to a large flux of NuMI (anti-)electron and (anti-)muon neutrinos, and poses a unique opportunity to provide high-statistics measurements of quasi-elastic and single pion-production cross sections for four neutrino flavors ($\nu_{\mu}$, $\nu_{e}$, $\bar{\nu}_{\mu}$, $\bar{\nu}_{e}$). This dissertation is centered around accurately characterizing the models and estimating their precision for use in making these measurements. This includes identifying major sources of uncertainty in the models such that they can be properly propagated to the cross section measurements. Specifically, this work focused on the model of the NuMI beamline and its impact on the neutrino fluxes, but also delved into the detector response model and its impact on reconstructed observables in the detector. Significant efforts were made to improve the characterization to enhance precision and thus reduce the level of propagated uncertainty. In particular, the NuMI flux was determined to be composed of 57% $\nu_{\mu}$, 38% $\bar{\nu}_{\mu}$, 3% $\nu_{e}$, and 2% $\bar{\nu}_{e}$ while the horns are operating in the positive-particle focusing configuration. The total uncertainty on the $\nu_{\mu} + \bar{\nu}_{\mu}$ ($\nu_{e} + \bar{\nu}_{e}$) flux while operating in the forward horn operating mode was determined to be 10.84% (9.04%). Compared to the on-axis flux, mesons that eventually decay to neutrinos more frequently reinteract within the NuMI structure, resulting in elevated uncertainty as these processes are not well-constrained by existing hadron interaction cross section measurements. Covariance matrices were calculated to propagate the flux uncertainty characterization to NuMI analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The overlapping plates method applied to CCD observations of 243 Ida

The overlapping plates method has been applied to crossing-point Charge Coupled Device (CCD) observations of minor planet 243 Ida to produce absolute position measurements precise to better than 0.1 sec and differential position measurements precise to better than 0.06 sec. Although these observations numbered only 17 out of the 520 that produced the final ground-based Ida ephemeris for the Galileo spacecraft flyby, their inclusion decreased Ida's downtrack error from 78 to 60 km and its out-of-plane error from 58 to 44 km.

Owen, W. M., Jr.↗

New physics contamination to precision luminosity measurements at future 𝑒 +⁢ 𝑒 − colliders

Several key observables of the high-precision physics program at future lepton colliders will critically depend on the knowledge of the absolute machine luminosity. The determination of the luminosity relies on the precise knowledge of some reference process, which is, in principle, not affected by unknown physics, so that its cross section can be computed within a well-established theory, like the Standard Model. Quantifying the uncertainties induced by possible new physics effects on such processes is, therefore, crucial. We present an investigation of light and heavy new physics contributions to the small-angle Bhabha process at future 𝑒 + ⁢𝑒 − colliders, and we discuss possible strategies to remove the contamination due to heavy degrees of freedom by relying on observables that are independent of the absolute luminosity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comprehensive Measurement of the Reactor Antineutrino Spectrum and Flux at Daya Bay

This Letter reports the precise measurement of the reactor antineutrino spectrum and flux based on the full dataset of 4.7 ×10 6 inverse-beta-decay candidates collected at Daya Bay near detectors. Expressed in terms of the inverse-beta-decay yield per fission, the antineutrino spectra from all reactor fissile isotopes and the specific 235 U and 239 Pu isotopes are measured with 1.3%, 3%, and 8% uncertainties, respectively, near the 3 MeV spectrum peak in reconstructed energy, reaching the best precision in the world. The total antineutrino flux and isotopic 235 U and 239 Pu fluxes are precisely measured to be 5.84 ± 0.07, 6.16 ± 0.12, and 4.16 ± 0.21 in units of 10 −43 cm 2 /fission. These measurements are compared with the Huber-Mueller model, the reevaluated conversion model based on the Kurchatov Institute measurement, and the latest summation model (SM2023). Furthermore, the Daya Bay flux shows good consistency with the Kurchatov Institute and SM2023 models but disagrees with the Huber-Mueller model. The Daya Bay spectrum, however, disagrees with all model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geoscience Laser Altimeter System (GLAS) for the ICESat Mission

The Geoscience Laser Altimeter System (GLAS) is a new generation lidar and is the primary science payload for NASA's ICESat Mission. The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, establish a grid of accurate height profiles of the Earth's land topography, and profile the vertical distribution of clouds and aerosols on a global scale. GLAS will be integrated onto a small spacecraft built by Ball Aerospace, and will be launched into a polar orbit with a 590-630 km altitude at an inclination of 94 degrees. ICESat is is currently planned to launch in winter 2002/03 and GLAS is designed to operate continuously in space for a minimum of 3 years. GLAS will measure the vertical distance from orbit to the Earth's surface with pulses from a ND:YAG laser at a 40 Hz rate. Each 6 nsec wide 1064 nm laser pulse is used to produce a single range measurement. On the surface, the laser footprints have 66 m diameter and approx. 170 m center-center spacings. The GLAS receiver uses a I m diameter telescope to detect laser backscatter and a Si APD to detect the 1064 nm signals. The detector's output is sampled by a digital ranging receiver, which records each transmitted pulse and surface echo waveform with 1 nsec (15 cm) resolution. Each echo pulse is digitized and is reported to ground with a record length of from 200 to 544 samples, depending on the spacecraft's location . The GLAS location and epoch times are measured by a precision GPS receiver carried on the ICESat spacecraft. Initial processing of the echo waveforms within GLAS permits discrimination between cloud and surface echoes for selecting appropriate waveform samples. This selection is guided by an on-board DEM which is used to set the boundaries for the echo pulse search algorithm. Subsequent ground-based echo pulse analysis, along with GPS-based clock frequency estimates, permit final determination of the range to the surface, degree of pulse spreading, and vertical distribution of any vegetation illuminated by the laser. Accurate knowledge of the laser beam's pointing angle is needed to prevent height biases when measuring over tilted surfaces, such as near the boundaries of ice sheets. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam's centroid angle to better than 10 urad is needed. GLAS uses a stellar reference system (SRS) to measure the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith and a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser is measured pulse relative to the star camera with a laser reference system (LRS). GLAS will also measure the vertical distributions of clouds and aerosols by recording the vertical profiles of laser pulse backscatter at both 1064 and 532 nm. The 1064 rim measurements use the Si APD detector and will be used to measure the height and echo pulse shape from thicker clouds. The lidar receiver at 532 nm uses a narrow bandwidth etalon filter and highly sensitive photon counting detectors. The 532 nm backscatter profiles will be used to measure the vertical extent of thinner clouds and the atmospheric boundary layer. The GLAS instrument component development is complete and the instrument is undergoing final testing and qualification at NASA-Goddard. The GLAS "as-built" characteristics and its expected measurement performance will be discussed.

Abshire, James B.↗

Sub-Hertz resonance by weak measurement

Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus has potential in precision measurement applications. Although frequency measurements offer the hitherto highest precision due to the stable narrow atomic transitions, it remains a long-standing interest to develop new schemes to further escalate their performance. Here, we demonstrate a WM-enhanced correlation spectroscopy technique capable of narrowing the resonance linewidth down to 0.1 Hz in a room-temperature atomic vapour cell. The potential of this technique for precision measurement is demonstrated through weak magnetic-field sensing. By judiciously pre- and post-selecting frequency-modulated input and output optical states in a nearly orthogonal manner, a sensitivity of 7 fT Hz -1/2 at a low frequency near DC is achieved using only one laser beam with 15 µW of power. Additionally, our results extend the WM framework to a non-Hermitian Hamiltonian and shed new light on metrology and bio-magnetic field sensing.

Science & Technology - Other Topics↗

First Measurements of Differential Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

Making high-precision measurements of neutrino oscillation parameters requires an unprecedented understanding of neutrino-nucleus scattering. In this presentation, we present the first muon neutrino charged current double-differential cross sections in kinematic imbalance variables. These variables characterize the imbalance in the plane transverse to an incoming neutrino. We use events with a single muon above 100 MeV/c, a single final state proton above 300 MeV/c, and no recorded final state pions. Thus, these variables act as a direct probe of nuclear effects such as final state interactions, Fermi motion, and multi-nucleon processes. We also present a complementary ongoing analysis using electron neutrinos. This channel is of the utmost importance for the extraction of neutrino oscillation parameters by making high-precision measurements. Our measurements allow us to constrain systematic uncertainties associated with neutrino oscillation results performed by near-future experiments of the Short Baseline Neutrino (SBN) program, as well as by future large-scale experiments like DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurements of Differential Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

Making high-precision measurements of neutrino oscillation parameters requires an unprecedented understanding of neutrino-nucleus scattering. In this presentation, we present the first muon neutrino charged current double-differential cross sections in kinematic imbalance variables. These variables characterize the imbalance in the plane transverse to an incoming neutrino. We use events with a single muon above 100 MeV/c, a single final state proton above 300 MeV/c, and no recorded final state pions. Thus, these variables act as a direct probe of nuclear effects such as final state interactions, Fermi motion, and multi-nucleon processes. We also present a complementary ongoing analysis using electron neutrinos. This channel is of the utmost importance for the extraction of neutrino oscillation parameters by making high-precision measurements. Our measurements allow us to constrain systematic uncertainties associated with neutrino oscillation results performed by near-future experiments of the Short Baseline Neutrino (SBN) program, as well as by future large-scale experiments like DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurements of Differential Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

Making high-precision measurements of neutrino oscillation parameters requires an unprecedented understanding of neutrino-nucleus scattering. In this presentation, we present the first muon neutrino charged current double-differential cross sections in kinematic imbalance variables. These variables characterize the imbalance in the plane transverse to an incoming neutrino. We use events with a single muon above 100 MeV/c, a single final state proton above 300 MeV/c, and no recorded final state pions. Thus, these variables act as a direct probe of nuclear effects such as final state interactions, Fermi motion, and multi-nucleon processes. We also present a complementary ongoing analysis using electron neutrinos. This channel is of the utmost importance for the extraction of neutrino oscillation parameters by making high-precision measurements. Our measurements allow us to constrain systematic uncertainties associated with neutrino oscillation results performed by near-future experiments of the Short Baseline Neutrino (SBN) program, as well as by future large-scale experiments like DUNE.

43 PARTICLE ACCELERATORS↗

Measurement of Precision Geometric Distances to Three Anchor Points in the Local Universe

We proposed a program to measure distances directly with accuracies of 5% to three anchor points in the Local Universe. We planned to accomplish this by conducting Very Long Baseline Interferometry (VLBI) observations of NGC 4258, M 33, and Sgr A*. These distance estimates should have a minimum of systematic uncertainty and can be used to re-calibrate several 'standard candles,' such as Cepheid and RR Lyrae variables. This will place the Galactic and extragalactic distance scales on much firmer ground. The primary contribution of our program will be to provide crucial independent checks and calibrations of extragalactic distance measurements. This will contribute to the ultimate success and impact of the HST Key Project on Extragalactic Distances and the Full-Sky Astrometric Mapping Explorer (FAME). Additionally, since distances are fundamental to astrophysics, our results will affect a large number of general projects on NASA facilities such as the Hubble Space Telescope, Chandra X-ray Observatory, and Next Generation Space Telescope.

Reid, Mark J.↗

Analysis of One-Way Laser Ranging Data to LRO, Time Transfer and Clock Characterization

We processed and analyzed one-way laser ranging data from International Laser Ranging Service ground stations to NASA's Lunar Reconnaissance Orbiter (LRO), obtained from June 13, 2009 until September 30, 2014. We pair and analyze the one-way range observables from station laser fire and spacecraft laser arrival times by using nominal LRO orbit models based on the GRAIL gravity field. We apply corrections for instrument range walk, as well as for atmospheric and relativistic effects. In total we derived a tracking data volume of approximately 3000 hours featuring 64 million Full Rate and 1.5 million Normal Point observations. From a statistical analysis of the dataset we evaluate the experiment and the ground station performance. We observe a laser ranging measurement precision of 12.3 centimeters in case of the Full Rate data which surpasses the LOLA (Lunar Orbiting Laser Altimeter) timestamp precision of 15 centimeters. The averaging to Normal Point data further reduces the measurement precision to 5.6 centimeters. We characterized the LRO clock with fits throughout the mission time and estimated the rate to 6.9 times10 (sup -8), the aging to 1.6 times 10 (sup -12) per day and the change of aging to 2.3 times 10 (sup -14) per day squared over all mission phases. The fits also provide referencing of onboard time to the TDB (Barycentric Dynamical Time) time scale at a precision of 166 nanoseconds over two and 256 nanoseconds over all mission phases, representing ground to space time transfer. Furthermore we measure ground station clock differences from the fits as well as from simultaneous passes which we use for ground to ground time transfer from common view observations. We observed relative offsets ranging from 33 to 560 nanoseconds and relative rates ranging from 2 times 10 (sup -13) to 6 times 10 (sup -12) between the ground station clocks during selected mission phases. We study the results from the different methods and discuss their applicability for time transfer.

Bauer, S.↗

Direct experimental constraints on the spatial extent of a neutrino wavepacket

Despite their high relative abundance in our Universe, neutrinos are the least understood fundamental particles of nature. In fact, the quantum properties of neutrinos emitted in experimentally relevant sources are theoretically contested and the spatial extent of the neutrino wavepacket is only loosely constrained by reactor neutrino oscillation data with a spread of 13 orders of magnitude. Here we present a method to directly access this quantity by precisely measuring the energy width of the recoil daughter nucleus emitted in the radioactive decay of beryllium-7. The final state in the decay process contains a recoiling lithium-7 nucleus, which is entangled with an electron neutrino at creation. The lithium-7 energy spectrum is measured to high precision by directly embedding beryllium-7 radioisotopes into a high-resolution superconducting tunnel junction that is operated as a cryogenic sensor. Under this approach, we set a lower limit on the Heisenberg spatial uncertainty of the recoil daughter of 6.2 pm, which implies that the final-state system is localized at a scale more than a thousand times larger than the nucleus itself. From this measurement, the first, to our knowledge, direct lower limit on the spatial extent of a neutrino wavepacket is extracted. These results may have implications in several areas including the theoretical understanding of neutrino properties, the nature of localization in weak nuclear decays and the interpretation of neutrino physics data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preface to the Proceedings of the 23rd Topical Conference on High-Temperature Plasma Diagnostics

Measurements of phenomena advance our understanding of the physical universe. As our understanding grows, more precise measurements are required, as are measurements of new quantities. Diagnosis of a plasma requires developing new instruments, also called diagnostics, as well as new ways to analyze, interpret, synthesize, and correlate their measurements. Further, as computing power increases and multi-physics codes improve their accuracy, more precise measurements are needed to guide future code developments and to validate predictions of these simulation codes. The Topical Conference on High-Temperature Plasma Diagnostics is focused on presenting and documenting the most recent advances in these instrumentation areas for plasmas. The 23rd occurrence of this biennial conference took place on December 14–17, 2020, and was hosted by Los Alamos National Laboratory. Originally scheduled for June 2020 in Santa Fe, New Mexico, the conference was postponed and then held virtually due to the global COVID-19 pandemic. Conference times were adjusted and presentations were scheduled to meet the needs of attendees in Europe, the USA, and Asia.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗