Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

First experimental measurements with the Segmented Inverted-coaxial GerMAnium (SIGMA) detector

The SIGMA project aims to develop a p-type segmented inverted coaxial point contact germanium detector for gamma-ray tracking and imaging. Here the performance of the first prototype of this type of detector is reported. The measurements performed verified the size and shape of the crystal and determined the location of the complex active volumes of the detector segments. The latter determines the charge collection times that are related to the position of interaction. Good agreement is found between the results and the specified crystal design. The energy resolution of the point contact has been measured to be 0.84 keV and 2.21 keV at 122 keV and 1332 keV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending Interfaces in 3D to Achieve Superior Nanoscale Strength in Ti/Nb Nanolaminates

Tuning the atomic-level structure of nanolaminates enables high strength, increased deformability, and the ability to absorb and mitigate damage due to varied crystalline defects, including dislocations. Here, we present the enhanced strength of Ti/Nb nanolaminates containing thick 3D interfaces (3DIs), relative to their chemically abrupt 2D counterparts. We examine the effects of crystallographic alignment and compositional gradients on mechanical behavior via experiments and phase-field-dislocation dynamics (PFDD) modeling. Mechanical testing reveals that nanolaminates containing thicker 3DIs demonstrate a 28% hardness enhancement compared with sharp-interface nanolaminates. PFDD modeling shows that the critical resolved shear stress (CRSS) increases with the 3DI thickness. Gradual compositional transitions in 3DIs were confirmed via scanning transmission electron microscopy and high-resolution transmission electron microscopy, showing sharp crystallographic transitions and a heightened interface topography. The findings establish a positive function between the 3DI thickness and mechanical robustness for hexagonal-closest-packed-containing composites, emphasizing the role of defect–interface interactions in tailoring the mechanical performance and providing a foundation for future interfacial engineering.

36 MATERIALS SCIENCE↗

Understanding capacity fade in organic redox-flow batteries by combining spectroscopy with statistical inference techniques

Organic redox-active molecules are attractive as redox-flow battery (RFB) reactants because of their low anticipated costs and widely tunable properties. Unfortunately, many lab-scale flow cells experience rapid material degradation (from chemical and electrochemical decay mechanisms) and capacity fade during cycling (>0.1%/day) hindering their commercial deployment. In this work, we combine ultraviolet-visible spectrophotometry and statistical inference techniques to elucidate the Michael attack decay mechanism for 4,5-dihydroxy-1,3-benzenedisulfonic acid (BQDS), a once-promising positive electrolyte reactant for aqueous organic redox-flow batteries. We use Bayesian inference and multivariate curve resolution on the spectroscopic data to derive uncertainty-quantified reaction orders and rates for Michael attack, estimate the spectra of intermediate species and establish a quantitative connection between molecular decay and capacity fade. Our work illustrates the promise of using statistical inference to elucidate chemical and electrochemical mechanisms of capacity fade in organic redox-flow battery together with uncertainty quantification, in flow cell-based electrochemical systems.

25 ENERGY STORAGE↗

Ancient co-option of LTR retrotransposons as yeast centromeres

Centromeres ensure accurate chromosome segregation, yet their DNA evolves rapidly across eukaryotes leaving the origins of new centromere architectures unclear. The brewer’s yeast Saccharomyces cerevisiae exemplifies this long-standing puzzle. Its centromeres shifted ancestrally from large, repeat-rich, epigenetically specified forms to the compact, genetically defined ‘point’ centromeres. How this transition occurred has remained unresolved6. Here we identify evolutionarily related ‘proto-point’ centromeres that provide a resolution to the evolutionary origins of point centromeres. Proto-point centromeres contain a single centromeric nucleosome positioned over an AT-rich core, accompanied by relaxed organization and sequence variability of flanking cis-elements. In two species, these proto-point centromeres lie within retrotransposon-derived repeat clusters, linking ancestral repeat-rich centromeres to genetically encoded ones. Comparative and phylogenetic analyses indicate that proto-point and point centromeres evolved in an ancestor with retrotransposon-rich centromeres. These results identify long-terminal-repeat retrotransposons, specifically Ty5 sequences, as the genetic substrate for point-centromere evolution and provide a mechanistic route by which an epigenetic centromere can become genetically specified. More broadly, they show how selfish elements can be co-opted to perform essential chromosomal functions.

Haase, Max A. B. [Max Planck Institute of Molecula↗

tRNA shape is an identity element for an archaeal pyrrolysyl-tRNA synthetase from the human gut

Protein translation is orchestrated through tRNA aminoacylation and ribosomal elongation. Among the highly conserved structure of tRNAs, they have distinguishing features which promote interaction with their cognate aminoacyl tRNA synthetase (aaRS). These key features are referred to as identity elements. In our study, we investigated the tRNA:aaRS pair that installs the 22nd amino acid, pyrrolysine (tRNAPyl:PylRS). Pyrrolysyl-tRNA synthetases (PylRSs) are naturally encoded in some archaeal and bacterial genomes to acylate tRNAPyl with pyrrolysine. Their large amino acid binding pocket and poor recognition of the tRNA anticodon have been instrumental in incorporating > 200 noncanonical amino acids. PylRS enzymes can be divided into three classes based on their genomic structure. Two classes contain both an N-terminal and C-terminal domain, however the third class (ΔpylSn) lacks the N-terminal domain. In this study we explored the tRNA identity elements for a ΔpylSn tRNAPyl from Candidatus Methanomethylophilus alvus which drives the orthogonality seen with its cognate PylRS (MaPylRS). From aminoacylation and translation assays we identified five key elements in ΔpylSn tRNAPyl necessary for MaPylRS activity. The absence of a base (position 8) and a G–U wobble pair (G28:U42) were found to affect the high-resolution structure of the tRNA, while molecular dynamic simulations led us to acknowledge the rigidity imparted from the G–C base pairs (G3:C70 and G5:C68).

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic structure and resistivity minimum in GdCuAs 2

The electrical resistivity of GdCuAs 2 single crystals exhibits an anomalous Kondo-like resistivity minimum above the antiferromagnetic ordering temperature T N 1 approximate to 10.6 K, which is unusual for a highly localized 4f-moment (Gd 3+ ) system. Using x-ray resonant magnetic scattering, we determined the magnetic structure of GdCuAs 2 , where Gd moments are antiferromagnetically aligned along the crystallographic a axis and in the (+ + --) arrangement in the c direction and ferromagnetically arranged in the b direction. The antiferromagnetic order appears first at q = (δ, 0, 0.5) below 10 K, with an incommensurate modulation along the a axis and locks into a commensurate position at q = (1/3, 0, 0.5) below T N 2 approximate to 6 K. Our high-resolution x-ray diffraction measurements show a two-peak structure at Q = (2, 0, 6) above the resistivity minimum, suggesting a lower-symmetry crystal structure than the reported tetragonal structure, and the Q = (2, 0, 6) peak becomes a sharp one-peak structure below the resistivity minimum, implying a magnetoelastic coupling above T N . In conclusion, our findings suggest a complex interplay between the crystal structure and antiferromagnetic structure through a magnetoelastic coupling, associated with the anomalous resistivity minimum above T N 1 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

E3SM‐Arctic: Regionally Refined Coupled Model for Advanced Understanding of Arctic Systems Interactions

Earth system models are essential tools for climate projections, but coarse resolutions limit regional accuracy, especially in the Arctic. Regionally refined meshes (RRMs) enhance resolution in key areas while maintaining computational efficiency. This paper provides an overview of the United States (U.S.) Department of Energy's (DOE's) Energy Exascale Earth System Model version 2.1 with an Arctic RRM, hereafter referred to as E3SMv2.1-Arctic, for the atmosphere (25 km), land (25 km), and ocean/ice (10 km) components. We evaluate the atmospheric component and its interactions with land, ocean, and cryosphere by comparing the RRM (E3SM2.1-Arctic) historical simulations (1950–2014) with the uniform low-resolution (LR) counterpart, reanalysis products, and observational data sets. The RRM generally reduces biases in the LR model, improving simulations of Arctic large-scale mean fields, such as precipitation, atmospheric circulation, clouds, atmospheric river frequency, and sea ice thickness. However, it introduces a seasonally dependent surface air temperature bias, reducing the LR cold bias in summer but enhancing the LR warm bias in winter, which contributes to the underestimated winter sea ice area and volume. Radiative feedback analysis shows similar climate feedback strengths in both model configurations, with the RRM exhibiting a more positive surface albedo feedback and contributing to a stronger surface warming than LR. These findings underscore the importance of high-resolution modeling for advancing our understanding of Arctic climate changes and their broader global impacts, although some persistent biases appear to be independent of model resolution at 10–100 km scales.

Energy Exascale Earth System Model (E3SM)↗

Resolving the Inner Parsec of the Blazar J1924–2914 with the Event Horizon Telescope

The blazar J1924–2914 is a primary Event Horizon Telescope (EHT) calibrator for the Galactic center’s black hole Sagittarius A*. Here we present the first total and linearly polarized intensity images of this source obtained with the unprecedented 20 μas resolution of the EHT. J1924–2914 is a very compact flat-spectrum radio source with strong optical variability and polarization. In April 2017 the source was observed quasi-simultaneously with the EHT (April 5–11), the Global Millimeter VLBI Array (April 3), and the Very Long Baseline Array (April 28), giving a novel view of the source at four observing frequencies, 230, 86, 8.7, and 2.3 GHz. These observations probe jet properties from the subparsec to 100 pc scales. We combine the multifrequency images of J1924–2914 to study the source morphology. We find that the jet exhibits a characteristic bending, with a gradual clockwise rotation of the jet projected position angle of about 90° between 2.3 and 230 GHz. Linearly polarized intensity images of J1924–2914 with the extremely fine resolution of the EHT provide evidence for ordered toroidal magnetic fields in the blazar compact core.

79 ASTRONOMY AND ASTROPHYSICS↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

Deriving spatially explicit direct and indirect interaction networks from animal movement data

Abstract Quantifying spatiotemporally explicit interactions within animal populations facilitates the understanding of social structure and its relationship with ecological processes. Data from animal tracking technologies (Global Positioning Systems [“GPS”]) can circumvent longstanding challenges in the estimation of spatiotemporally explicit interactions, but the discrete nature and coarse temporal resolution of data mean that ephemeral interactions that occur between consecutive GPS locations go undetected. Here, we developed a method to quantify individual and spatial patterns of interaction using continuous‐time movement models (CTMMs) fit to GPS tracking data. We first applied CTMMs to infer the full movement trajectories at an arbitrarily fine temporal scale before estimating interactions, thus allowing inference of interactions occurring between observed GPS locations. Our framework then infers indirect interactions—individuals occurring at the same location, but at different times—while allowing the identification of indirect interactions to vary with ecological context based on CTMM outputs. We assessed the performance of our new method using simulations and illustrated its implementation by deriving disease‐relevant interaction networks for two behaviorally differentiated species, wild pigs ( Sus scrofa ) that can host African Swine Fever and mule deer ( Odocoileus hemionus ) that can host chronic wasting disease. Simulations showed that interactions derived from observed GPS data can be substantially underestimated when temporal resolution of movement data exceeds 30‐min intervals. Empirical application suggested that underestimation occurred in both interaction rates and their spatial distributions. CTMM‐Interaction method, which can introduce uncertainties, recovered majority of true interactions. Our method leverages advances in movement ecology to quantify fine‐scale spatiotemporal interactions between individuals from lower temporal resolution GPS data. It can be leveraged to infer dynamic social networks, transmission potential in disease systems, consumer–resource interactions, information sharing, and beyond. The method also sets the stage for future predictive models linking observed spatiotemporal interaction patterns to environmental drivers.

59 BASIC BIOLOGICAL SCIENCES↗

High-Resolution Momentum Imaging—From Stern’s Molecular Beam Method to the COLTRIMS Reaction Microscope [Book Chapter]

Multi-particle momentum imaging experiments are now capable of providing detailed information on the properties and the dynamics of quantum systems in Atomic, Molecular and Photon (AMO) physics. Historically, Otto Stern can be considered the pioneer of high-resolution momentum measurements of particles moving in a vacuum and he was the first to obtain sub-atomic unit (a.u.) momentum resolution (Schmidt-Böcking et al. in The precision limits in a single-event quantum measurement of electron momentum and position, these proceedings). A major contribution to modern experimental atomic and molecular physics was his so-called molecular beam method, which Stern developed and employed in his experiments. With this method he discovered several fundamental properties of atoms, molecules and nuclei. As corresponding particle detection techniques were lacking during his time, he was only able to observe the averaged footprints of large particle ensembles. Today it is routinely possible to measure the momenta of single particles, because of the tremendous progress in single particle detection and data acquisition electronics. A “state-of-the-art” COLTRIMS reaction microscope can measure, for example, the momenta of several particles ejected in the same quantum process in coincidence with sub-a.u. momentum resolution. Such setups can be used to visualize the dynamics of quantum reactions and image the entangled motion of electrons inside atoms and molecules. This review will briefly summarize Stern’s work and then present in longer detail the historic steps of the development of the COLTRIMS reaction microscope. Furthermore, some benchmark results are shown which initially paved the way for a broad acceptance of the COLTRIMS approach. Finally, a small selection of milestone work is presented which has been performed during the last two decades.

Jahnke, T.↗

Characterization and alignment of a resonant cavity beam position monitor for the Compact LInear Collider (CLIC) project at CERN

Beam diagnostic devices are essential tools to sense the properties of the beam in particle accelerators. Beam Position Monitors (BPMs) are used to detect the transverse beam spatial coordinates. A large number of high-resolution resonant cavity BPMs, operating at 14GHz, are proposed to monitor the orbit of the two main beam linacs of the CLIC project. This paper discusses innovative calibration techniques on a dedicated test bench in the frame of the PACMAN project. The particular location of the electromagnetic center of the resonant cavity BPM is detected utilizing a stretched-wire measurement approach. Measurements, RF characterization and final fiducialization of the BPM electrical offset are treated with details. Initial studies through EM simulations of the cavity BPM are covered. The presented experimental results prove the feasibility of the alignment methodology with nanometric resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracellular filaments revealed by affinity capture cryogenic-electron tomography

Cryogenic-electron tomography (cryo-ET) has provided an unprecedented glimpse into the nanoscale architecture of cells by combining cryogenic preservation of biological structures with electron tomography. Micropatterning of extracellular matrix proteins is increasingly used as a method to prepare adherent cell types for cryo-ET as it promotes optimal positioning of cells and subcellular regions of interest for vitrification, cryo-focused ion beam (cryo-FIB) milling, and data acquisition. Here we demonstrate a micropatterning workflow for capturing minimally adherent cell types, human T cells and Jurkat cells, for cryo-FIB and cryo-ET. Our affinity capture system facilitated the nanoscale imaging of Jurkat cells, revealing extracellular filamentous structures. It improved workflow efficiency by consistently producing grids with a sufficient number of well-positioned cells for an entire cryo-FIB session. Affinity capture can be extended to facilitate high-resolution imaging of other adherent and non-adherent cell types with cryo-ET.

Biochemistry↗

Exploring leakage in dielectric films via automated experiments in scanning probe microscopy

Here electronic conduction pathways in dielectric thin films are explored using automated experiments in scanning probe microscopy (SPM). In this study, we use large field of view scanning to identify the position of localized conductive spots and develop an SPM workflow to probe their dynamic behavior at higher spatial resolution as a function of time, voltage, and scanning process in an automated fashion. Using this approach, we observe the variable behaviors of the conductive spots in a 20-nm-thick ferroelectric Hf 0.54 Zr 0.48 O 2 film, where conductive spots disappear and reappear during continuous scanning. There are also fresh conductive spots that develop during scanning. The automated workflow is universal and can be integrated into a wide range of microscopy techniques, including SPM, electron microscopy, optical microscopy, and chemical imaging.

36 MATERIALS SCIENCE↗

Design and performance characterisation of the HAPG von Hámos Spectrometer at the High Energy Density Instrument of the European XFEL

The von Hámos spectrometer setup at the HED instrument of the European XFEL is described in detail. The spectrometer is designed to be operated primarily between 5 and 15 keV to complement the operating photon energy range of the HED instrument. Four Highly Annealed Pyrolitic Graphite (HAPG) crystals are characterised with thicknesses of 40 μm or 100 μm and radius-of-curvature 50 mm or 80 mm, in conjunction with either an ePix100 or Jungfrau detector. The achieved resolution with the 50 mm crystals, operated between 6.5 and 9 keV, matches that reported previously: ~8 eV for a thickness of 40 μm, whereas, with an 80 mm crystal of thickness 40 μm, the resolution exceeds that expected. Namely, a resolution of 2 eV is demonstrated between 5–6 keV implying a resolving power of 2800. Therefore, we posit that flatter HAPG crystals, with their high reflectivity and improved resolving power, are a powerful tool for hard x-ray scattering and emission experiments allowing unprecedented measurements of collective scattering in a single shot.

47 OTHER INSTRUMENTATION↗

Multigrid Optimization for Large-Scale Ptychographic Phase Retrieval

Ptychography is a popular imaging technique that combines diffractive imaging with scanning microscopy. The technique consists of a coherent beam that is scanned across an object in a series of overlapping positions, leading to reliable and improved reconstructions. Ptychographic microscopes allow for large fields to be imaged at high resolution at the cost of additional computational expense. Herein, we propose a multigrid-based optimization framework to reduce the computational burdens of large-scale ptychographic phase retrieval. Our proposed method exploits the inherent hierarchical structures in ptychography through tailored restriction and prolongation operators for the object and data domains. Our numerical results show that our proposed scheme accelerates the convergence of its underlying solver and outperforms the ptychographical iterative engine, a workhorse in the optics community.

97 MATHEMATICS AND COMPUTING↗

High-Resolution ESM Projections for Energy Applications Over the CONUS

Assessing energy resources under future scenarios requires high-resolution meteorological information that is physically consistent and suitable for regional-scale analysis. While Earth system model (ESM) projections provide valuable large-scale information, their coarse resolution and systematic biases limit direct applicability for energy system modeling and planning. In this study, we develop a high-resolution dynamical downscaling framework based on the Weather Research and Forecasting (WRF) model to translate global-scale ESM data into energy-relevant regional projections over the contiguous United States (CONUS). The framework identifies an optimized WRF configuration through numerical experiments and evaluates raw and bias-corrected ESM initial and boundary conditions, with soil moisture (SM) and soil temperature (ST) bias correction implemented as an integral part of the bias-corrected ESM forcing to improve land-atmosphere coupling prior to WRF dynamical downscaling. Using an optimized WRF configuration at 4-km resolution, we show that raw ESM forcing introduces systematic dry and cold soil biases that propagate into pronounced warm biases in near-surface air temperature and positive biases in solar irradiance, particularly during summer. Applying bias-corrected atmospheric forcing together with bias-corrected SM and ST substantially reduces these downstream biases and improves the surface energy balance and near-surface atmospheric fields. These results demonstrate that bias-aware treatment of initial conditions is critical for producing high-resolution downscaled projections suitable for energy system modeling and planning applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗