Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Performance Analysis on Fault Tolerant Control System

In a fault tolerant control (FTC) system, a parameter varying FTC law is reconfigured based on fault parameters estimated by fault detection and isolation (FDI) modules. FDI modules require some time to detect fault occurrences in aero-vehicle dynamics. In this paper, an FTC analysis framework is provided to calculate the upper bound of an induced-L(sub 2) norm of an FTC system with existence of false identification and detection time delay. The upper bound is written as a function of a fault detection time and exponential decay rates and has been used to determine which FTC law produces less performance degradation (tracking error) due to false identification. The analysis framework is applied for an FTC system of a HiMAT (Highly Maneuverable Aircraft Technology) vehicle. Index Terms fault tolerant control system, linear parameter varying system, HiMAT vehicle.

Shin, Jong-Yeob↗

A cascaded coding scheme for error control and its performance analysis

A coding scheme for error control in data communication systems is investigated. The scheme is obtained by cascading two error correcting codes, called the inner and the outer codes. The error performance of the scheme is analyzed for a binary symmetric channel with bit error rate epsilon < 1/2. It is shown that, if the inner and outer codes are chosen properly, extremely high reliability can be attained even for a high channel bit error rate. Various specific example schemes with inner codes ranging from high rates to very low rates and Reed-Solomon codes are considered, and their probabilities are evaluated. They all provide extremely high reliability even for very high bit error rates, say 0.1 to 0.01. Several example schemes are being considered by NASA for satellite and spacecraft down link error control.

Lin, S.↗

A cascaded coding scheme for error control and its performance analysis

A coding scheme for error control in data communication systems is investigated. The scheme is obtained by cascading two error-correcting codes, called the inner and outer codes. Its error performance is analyzed for a binary symmetric channel with bit-error rate epsilon less than 1/2. It is shown that, if the inner and outer codes are chosen properly, high reliability can be attained even for a high-channel bit-error rate. Specific examples with inner codes ranging from high rates and Reed-Solomon codes as outer codes are considered, and their error probabilities evaluated. They all provide high reliability even for high bit-error rates, say 0.1-0.01. Several example schemes are being considered for satellite and spacecraft downlink error control.

Kasami, Tadao↗

Statistical Performance Analysis on Approximately 320 Perovskite Single- and Two-Junction Solar Cells and Modules from >30 Global Sources

As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? We compile results from ca. 320 perovskite PV cells and modules, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, and show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. We discuss implications of these findings on performance testing protocols and propose possible options for fast and accurate testing of perovskite PV.

asymptotic↗

DS-CDMA satellite diversity reception for personal satellite communication: Downlink performance analysis

The downlink of a satellite-mobile personal communication system employing power-controlled Direct Sequence Code Division Multiple Access (DS-CDMA) and exploiting satellite-diversity is analyzed and its performance compared with a more traditional communication system utilizing single satellite reception. The analytical model developed has been thoroughly validated by means of extensive Monte Carlo computer simulations. It is shown how the capacity gain provided by diversity reception shrinks considerably in the presence of increasing traffic or in the case of light shadowing conditions. Moreover, the quantitative results tend to indicate that to combat system capacity reduction due to intra-system interference, no more than two satellites shall be active over the same region. To achieve higher system capacity, differently from terrestrial cellular systems, Multi-User Detection (MUD) techniques are likely to be required in the mobile user terminal, thus considerably increasing its complexity.

DeGaudenzi, Riccardo↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

Dust Abrasion Damage on Martian Solar Arrays: Experimental Investigation and Opportunity Rover Performance Analysis

Here we investigate the effects of erosion and weathering that occur on III-V cover-glass interconnected cells (CICs) after exposure to Mars dust storm conditions. The durability of these materials in a Martian environment is not well characterized so we perform analogous experimentation. To replicate the dust impingement, test coupons were placed in an enclosure and sandblasted with Mars dust simulant. We show the J-V response dependency on both incident angle and exposure times. We find that the simulated Martian dust storm often results in damage to the anti-reflective coating and subsequent reduced short circuit current. Reduction in the open circuit voltage is observed, likely caused by structural damage to the crystal lattice after CIC fracture. We employ data-driven modeling to determine a performance degradation rate that is consistent with zero within uncertainty. We also quantify the soiling contribution and power degradation of the photovoltaic cells on Mars through analysis of 4.95 Martian years of report-out power conditions from the Opportunity rover. We find that atmospheric dust suspended due to a weather event does not result in instantaneous settled dust on the PV cells. We calculate via autocorrelation function that the dust settling rate is approximately 21 Sols from atmospheric dust suspension. The findings presented here deliver a realistic approximation for the insolation values and subsequent PV power expected over time on the Martian surface thus informing future dust abatement systems.

McMillon-Brown, Lyndsey↗

Dust Abrasion Damage on Martian Solar Arrays: Experimental Investigation and Opportunity Rover Performance Analysis

Here we investigate the effects of erosion and weathering that occur on III-V cover-glass interconnected cells (CICs) after exposure to Mars dust storm conditions. The durability of these materials in a Martian environment is not well characterized so we perform analogous experimentation. To replicate the dust impingement, test coupons were placed in an enclosure and sandblasted with Mars dust simulant. We show the J-V response dependency on both incident angle and exposure times. We find that the simulated Martian dust storm often results in damage to the anti-reflective coating and subsequent reduced short circuit current. Reduction in the open circuit voltage is observed, likely caused by structural damage to the crystal lattice after CIC fracture. We employ data-driven modeling to determine a performance degradation rate that is consistent with zero within uncertainty. We also quantify the soiling contribution and power degradation of the photovoltaic cells on Mars through analysis of 4.95 Martian years of report-out power conditions from the Opportunity rover. We find that atmospheric dust suspended due to a weather event does not result in instantaneous settled dust on the PV cells. We calculate via autocorrelation function that the dust settling rate is approximately 21 Sols from atmospheric dust suspension. The findings presented here deliver a realistic approximation for the insolation values and subsequent PV power expected over time on the Martian surface thus informing future dust abatement systems.

McMillon-Brown, Lyndsey↗

Gaussian approximation versus nearly exact performance analysis of optical communication systems with PPM signaling and APD receivers

A 25-Mb/s direct-detection optical communication system that used Q = 4 PPM (pulse-position modulation) signaling was constructed and its performance measured under laboratory conditions. The system used a single-mode AlGaAs laser diode (lambda = 834 nm) and low-noise silicon avalanche photodiode (APD). A procedure for numerically computing system performance is given that uses the nearly exact Webb approximation of the true Conradi distribution for the APD output and does not require excessive amounts of computer time. Comparison revealed that modeling the APD ouptut as a Gaussian process under conditions of negligible background radiation and low (less than 10 to the -12 A) APD bulk leakage currents leads to substantial underestimates of optimal APD gain and overestimates of system bit error probability. Examples illustrate the breakdown of the Gaussian approximation in assessing system performance. The measured performance was in excellent agreement with that predicted by the computational procedure. The system achieved a bit error probability of 10 to the -6 at a received signal energy, corresponding to an average of 60 absorbed photons/bit and optimal APD gain of 700.

Davidson, Frederic M.↗

Axial and centrifugal pump meanline performance analysis

A meanline pump flow modeling method has been developed to provide a fast capability for modeling pumps of cryogenic rocket engines. Based on this method, a meanline pump flow code (PUMPA) has been written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The design point rotor efficiency is obtained from empirically derived correlations of loss to rotor specific speed. The rapid input setup and computer run time for the meanline pump flow code makes it an effective analysis and conceptual design tool. The map generation capabilities of the PUMPA code provide the information needed for interfacing with a rocket engine system modeling code.

Veres, Joseph P.↗

HabEx Baseline Telescope: Design & Performance Analysis

HabEx is one of four missions under study for 2020 Astrophysics Decadal Survey. It will directly image and spectroscopically characterize planetary systems in the habitable zone of Sun-like stars. Additionally, HabEx will perform a broad range of general astrophysics science enabled by 115 to 2500 nm spectral range and 3 x 3 arc-minute FOV.

Space Mirror Technology↗

A Performance analysis of the Claridge-Culp-Liu dehumidification process: A novel approach for drying moist air based on membrane separation, vacuum compression and sub-atmospheric condensation

This article covers a basic model for analyzing the performance of the Claridge-Culp-Liu dehumidification process. The fundamental process efficiency limit for dehumidification is close to COP Carnot , but for the eight dehumidification cases examined, the limiting or ideal energy use required is 26% to 56% that of a Carnot condensing system as shown in an earlier paper. The model presented in this paper is used to show the membrane system performance reduction caused by finite membrane area, finite water vapor permeance, non-zero air permeance, non-zero system air pressure drop, non-ideal compressors, vacuum pumps, and condensers. The performance of a “conservative” membrane system based on the use of existing components is computed for eight specific conditions along with that of a “target” system that assumes expected component performance after additional future component development. The “conservative” membrane system would use 36% to 66% as much energy as a system with a COP=7 chiller to produce the same dehumidification for the eight cases examined while the “target” system would use 15% to 40% the energy of a system with a COP=7 chiller. In addition to the significant energy reduction over conventional technology, the membrane system offers the advantages of: 1) no HFC refrigerant use; 2) direct isothermal control over humidity ratio setpoint; 3) maximum capacity occurs at design conditions; and 4) system generates pure water extracted from air as a by-product.

42 ENGINEERING↗

Performance analysis of pulse Doppler digital radars with application to the Shuttle Ku-band system

A pulse Doppler digital radar is one of the primary components of the Ku-band integrated radar and communication equipment on the Space Shuttle. The performance of the Ku-band rendezvous radar to be used on the Space Shuttle is analyzed in four parts. First an overall functional block diagram description is presented to illustrate the signal processing in the detection and the tracking modes. The detection capabilities and limitations of the radar are investigated taking all of the system losses into account. A new unified analysis of digital radar tracking loops is developed which takes into consideration the effects of a scintillating target and receiver front end noise. The behavior of the radar is discussed in the presence of thermal noise, amplitude scintillation, and target glint.

Alem, W. K.↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

Performance of Compressor of XJ-41-V Turbojet Engine V-Performance Analysis of Compressor with Revised Vaned Collector over Range of Compressor Speeds from 3600 to 11,500 RPM

An investigation of the XJ-41-V turbojet-engine compressor with a revised vaned collector was conducted to determine the performance of the compressor and to obtain fundamental information on the aerodynamic problems associated with large centrifugal compressors of this type. The original vaned collector was revised by increasing the flow area at the vaned collector entrance. A maximum adiabatic efficiency of 0.81 was obtained et a corrected weight flow of 36.5 pounds per second and a pressure ratio of 1.90. The peak pressure ratio was 3.93 and occurred at an impeller speed of 11,500 rpm at a corrected weight flow of 65.5 pounds per second. Revision of the vaned collector resulted in an increased airflow capacity over the speed range. The design air-flow capacity of 78 pounds per second was very nearly reached at the engine design speed of 11,500 rpm. The compressor air-flow choking point occurred in the vaned collector passage; however, at speeds above 8300 rpm, the air-flow capacity of the impeller was being approached as indicated by large pressure losses in the impeller at maximum air-flow conditions. An increase in compressor air-flow capacity at the higher speeds can possibly be obtained 5y removal of the flow restriction in the impeller, which would result in an increased air density at the vaned collector entrance.

Ginsburg, Ambrose↗

Composition-Nanoarchitecture-Performance Analysis of High Energy Density Electrodeposited Silicon for Lithium-Ion Battery Anodes

Electrodeposition of silicon (Si) was previously demonstrated as a promising method for fabricating 3D-structured lithium-ion battery anodes. However, the relationship between the electrochemical performance and chemical composition of the relatively impure electrodeposited silicon is not well understood. Here, we report the electrodeposition of a Si-dominant active material (EDEP-Si) onto 3D-structured nickel (Ni) scaffolds and systematically compare the electrochemical properties, elemental composition, atomistic Si coordination, and molecular structure of EDEP-Si with high-purity amorphous Si grown via static chemical vapor deposition. Despite the considerable amount of carbon (9–11 at %) and oxygen (42–44 at %) present in EDEP-Si, the cycling stability and high reversible specific capacity are remarkably similar to those of CVD-Si on a silicon basis (~2400 mA h/g-Si after 100 cycles). The primary difference is that EDEP-Si exhibits reduced cycling efficiency over the first 10–20 cycles. Reactions between carbon and, more importantly, oxygen in EDEP-Si with lithium are likely responsible for the reduced early cycle performance and lower capacity of the total deposit. Finally, our observations suggest ultrapure Si is not necessary for high electrochemical access to reversible charge storage, although limiting the presence of incorporated impurity species would improve energy density and first cycle efficiency.

25 ENERGY STORAGE↗

Human Performance Analysis Depending on Operator Expertise (Student vs. Operator) and Simulator Complexity (Rancor Microworld vs. Compact Nuclear Simulator)

Human reliability analysis (HRA) evaluates human errors and provides human error probabilities (HEPs) for application in probabilistic safety assessment (PSA), which is a comprehensive safety assessment method for nuclear power plants (NPPs). Generally, HRA methods estimate HEPs based on human reliability data collected from actual historical measurement, simulator experiments, or expert judgement. Most recent HRA data collection studies focus on collecting data via full-scope main control room (MCR) simulators with actual licensed reactor operators. Contrary to this, Idaho National Laboratory (INL) has adopted a different approach, which attempts to collect HRA data based on experiment using simplified simulators and student participants by following the Simplified Human Error Experimental Program (SHEEP). This approach has a couple of advantages compared to full-scope data collection. Representatively, it has relatively low entry point for collecting HRA data, and secures large sample sizes with reasonable cost and labor. In the previous studies, we developed the SHEEP framework, then verified whether the data collected through the framework could support a representative full-scope data collection study, i.e., the Human Reliability Data Extraction (HuREX) study. Also, we analyzed human performance measurements depending on participant type (i.e., student vs. operator). In this paper, we analyze human performance data collected from an experiment comparing operator expertise and simulator complexity when using the more simplified simulator developed by INL, i.e., Rancor Microworld and the less simplified simulator, i.e., Compact Nuclear Simulator (CNS) developed by Korea Atomic Energy Research Institute (KAERI). Analysis of variance (ANOVA) tests and correlation analysis are used for analyzing the experimental data.

99 GENERAL AND MISCELLANEOUS↗

Fuel performance analysis of Cr-coated Zircaloy-4 cladding during a prototypical LOCA event using BISON

Here, deformation and failure of chromium (Cr) coated Zircaloy-4 (Zry-4) were studied in loss-of-coolant accident (LOCA) conditions using the BISON fuel performance code. The BISON validation model simulating Halden research reactor experiments was extended to include Cr coatings and higher rod internal pressures to simulate high-burnup fuel. The transient simulations show Cr coatings help relieve stress in the Zry-4 substrate during the transient, delaying the onset of high-temperature creep, which leads to ballooning and bursting of the cladding. A nominal Cr coating thickness of 30 µm delays clad failure by 26 seconds and increases the clad burst temperature by 40 K. A parametric study showed that time to failure and burst temperature both increase with coating thickness, and Cr-coated cladding offers burst resistance under a wide range of rod internal pressures simulating high-burnup fuel. Results indicate that a thin Cr coating provides resistance against ballooning and bursting of cladding during LOCA events.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗