Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Measuring Pressure Has a New Standard

The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.

Source record↗

A densely spaced array of sea level monitors for the detection of vertical crustal deformation in the Shumagin seismic gap, Alaska

A network of sea level gauges has been installed with about 40 km spacing in the Shumagin Islands in order to detect relative vertical motion, in particular, possible crustal motion precursory to an expected major earthquake. This required the development and deployment of a pressure sensor sea level gauge suitable for installation on remote and harsh coastlines. Data are collected in near-real-time via satellite, both in order to exploit fully any precursors that may be observed and to provide continuous information on the status of the instruments. Using Wiener filtering techniques, it has been determined conservatively that no relative vertical crustal motion greater than 0.1 m between stations has occurred during 1981-1985. This is consistent with independent geodetic leveling and trilateration data, though evidence exists for more rapid deformation during 1978-1980. The sea level data collected so far have an rms noise level of about 0.04 m after processing; this is limited in part by the pressure sensor and associated electronics. Improved prressure gauges with better long-term stability have recently been installed. A short-baseline tiltmeter operating in a tunnel has demonstrated that suitably designed and located land-based tiltmeters have a lower noise level, and hence better precursor detection characteristics than the sea level gauges, at monthly and shorter periods.

Beavan, John↗

Space Suit Portable Life Support System Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure control for the crew member during prebreathe, Extra-Vehicular Activity (EVA), post EVA airlock operations, and Decompression Sickness (DCS) treatment. It has been over four decades since a new spacesuit oxygen regulator has been designed. The regulator and EMU that is presently used on the International Space Station (ISS) was developed for the space shuttle program without any significant changes made throughout its service life. The xEMU spacesuit oxygen regulator is based on the previous EMU Secondary Oxygen Pack (SOP). The new design integrates numerous improvements and changes including an innovative approach to regulator architecture, a more robust first stage pressure sensing mechanism, digital actuation control, and electronic pressure sensing. These upgrades replace manual control linkages, physical gauges, and enable infinitely variable pressure set points. The new setpoints can decrease prebreathe time and make in suit DCS treatment possible. Throughout its four iterations design concerns have been addressed, safety features have been added, and the envelope of the regulator designed to fit inside the xEMU PLSS package. This paper will review the history, design, testing, and lessons learned during the development of the xEMU PLSS Oxygen Regulator.

Ryan Eric Ogilvie↗

Space Suit Portable Life Support System (PLSS) Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure control for the crew member during prebreathe, Extra-Vehicular Activity (EVA), post EVA airlock operations, and Decompression Sickness (DCS) treatment. It has been over four decades since a new spacesuit oxygen regulator has been designed. The regulator and EMU that is presently used on the International Space Station (ISS) was developed for the space shuttle program without any significant changes made throughout its service life. The xEMU spacesuit oxygen regulator is based on the previous EMU Secondary Oxygen Pack (SOP). The new design integrates numerous improvements and changes including an innovative approach to regulator architecture, a more robust first stage pressure sensing mechanism, digital actuation control, and electronic pressure sensing. These upgrades replace manual control linkages, physical gauges, and enable infinitely variable pressure set points. The new setpoints can decrease prebreathe time and make in suit DCS treatment possible. Throughout its four iterations design concerns have been addressed, safety features have been added, and the envelope of the regulator designed to fit inside the xEMU PLSS package. This paper will review the history, design, testing, and lessons learned during the development of the xEMU PLSS Oxygen Regulator.

Ryan Ogilvie↗

Carbon Nanotube Vacuum Gauges Utilizing Long, Dissipative Tubes

CNT Vacuum Gauges: a) have a broad range of pressure response from 760 - 10(exp -6) Torr. b) have current changes approx. 100's nA in high vacuum regime (10(exp -6) Torr) and sensitivity increases with power and substrate removal. c) have a negative dR/dT (TCR negative) where a thermal hopping energy E(sub a) was determined to be approx. 40 meV. d) have compatible fabrication requirements for their integration with micromachined structures. e) can be operated at low power (nW - micro-W). f) have an active device region footprint of < 10 sq microns. g) are non-intrusive due to small size and passive operation.

nanotube sensors↗

Graphite ionization vacuum gauge

Triode gauge with electron source, electron collector, and positive ion collector made from either graphite or carbon material extends low-pressure ranges of existing gauges by changing only materials used in construction. Advantages of graphite gauge stem from physical properties of graphite (or carbon).

Beitel, G. A.↗

Additively Manufactured, Net Shape Powder Metallurgy Cans for Valves Used in Energy Production

Additive manufacturing (AM) has the potential to enable a paradigm shift in fabricating complex net shape components with yields over 90%, significantly increasing productivity, decreasing energy consumption during manufacturing and improving downstream energy efficiency. ORNL has developed a technology for producing large-scale additively manufactured polymer matrix composite components at deposition rates on the order of 100 lbs. per hour. This project utilized tools, dies and molds made from this technology to enable the net shape forming of cans for the powder metallurgy (PM) manufacturing of valves used in energy production plants. This approach has the potential to develop affordable valves with superior performance to castings. It will also lead to increased strength values, decreased wall thickness size, and the potential for higher yields (less machining). This project is critical for evaluating new methodologies for the fabrication of additively manufactured tooling, molds and dies that could be used across multiple industries. In the first phase of this project, a new methodology of creating a Powder Metallurgy and Hot Isostatic Pressing (PM-HIP) container by hydroforming sheet metal over additively manufactured (AM) dies was evaluated. The goal in this stage of development was to evaluate some of the new polymer matrix composite materials designed for deposition on large scale additive manufacturing systems as candidates for hydroforming steel and aluminum sheet to make thin gauge net shape components. In order to meet this objective, most research was performed on subscale tools in order to evaluate the processing pressures, material options, and gauge thicknesses most relevant to this approach. In addition, full scale AM tools (30% over final component geometry) were produced to demonstrate scalability, but were not used in testing. The first phase of this project has proven this concept has merit, but future studies are required to address minor tool failures that occurred in phase one due to geometry, cost of the process over other techniques, and demonstration of a full-scale tool that could then be used in (HIP). Lastly, this project provides the PM community a new approach in using hydroforming for the manufacturing of cans, a process that was not highly utilized for this purpose previously.

42 ENGINEERING↗

MMS Observatory TV Results Contamination Summary

The Magnetospheric Multiscale (MMS) mission is a constellation of 4 observatories designed to investigate the fundamental plasma physics of reconnection in the Earth's magnetosphere. The various instrument suites measure electric and magnetic fields, energetic particles, and plasma composition. Each spacecraft has undergone extensive environmental testing to prepare it for its minimum 2 year mission. In this paper, we report on the extensive thermal vacuum testing campaign. The testing was performed at the Naval Research Laboratory utilizing the "Big Blue" vacuum chamber. A total of ten thermal vacuum tests were performed, including two chamber certifications, three dry runs, and five tests of the individual MMS observatories. During the test, the observatories were enclosed in a thermal enclosure known as the "hamster cage". The enclosure allowed for a detailed thermal control of various observatory zone, but at the same time, imposed additional contamination and system performance requirements. The environment inside the enclosure and the vacuum chamber was actively monitored by several QCMs, RGA, and up to 18 ion gauges. Each spacecraft underwent a bakeout phase, which was followed by 4 thermal cycles. Unique aspects of the TV campaign included slow pump downs with a partial represses, thruster firings, Helium identification, and monitoring pressure spikes with ion gauges. Selected data from these TV tests is presented along with lessons learned.

Pressure↗

Precise method of compensating radiation-induced errors in a hot-cathode-ionization gauge with correcting electrode

To compensate pressure-measurement errors caused by a synchrotron radiation environment, a precise method using a hot-cathode-ionization-gauge head with correcting electrode, was developed and tested in a simulation experiment with excess electrons in the SPring-8 storage ring. This precise method to improve the measurement accuracy, can correctly reduce the pressure-measurement errors caused by electrons originating from the external environment, and originating from the primary gauge filament influenced by spatial conditions of the installed vacuum-gauge head. As the result of the simulation experiment to confirm the performance reducing the errors caused by the external environment, the pressure-measurement error using this method was approximately less than several percent in the pressure range from 10{sup −5} Pa to 10{sup −8} Pa. After the experiment, to confirm the performance reducing the error caused by spatial conditions, an additional experiment was carried out using a sleeve and showed that the improved function was available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately-known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is on the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream pressure. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Development Plan for Ultrasonic Pressure Sensors [Slides]

Current light water reactors (LWRs) utilize differential pressure cells, based on strain gauges, which are remotely located from the reactor vessel via impulse lines. These pressure sensors are used to measure liquid level within the vessel and to give a general indication of system health with regard to leaks and flow system fouling. The advanced reactor types currently under development generally operate at higher temperatures than light-water reactors and utilize coolants that may be highly corrosive (i.e., liquid metals). They will use pressure measurements for varied measurands, such as level and flow rate, as well as indications of accident conditions or off-normal operating conditions. More robust pressure sensors are needed to address these more challenging conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Computational Analysis of Boundary Layer Instability over the BOLT Configuration

The complex boundary layer flow over the BOLT flight configuration is known to exhibit multiple and potentially interacting instability mechanisms. This paper represents a continuation of our numerical investigation of the flow instabilities over the main test surface of the BOLT configuration by using state-of-the-art tools in multidimensional instability analysis. Specifically, the paper extends our previous computations by considering the separate effects of a nonzero angle of attack and a nonzero yaw on the modal instability characteristics of the boundary layer streaks adjacent to the minor-axis symmetry plane, specifically near both ends of the azimuthal region of a thick boundary layer in the middle, where this region rapidly changes to a thinner boundary layer on either side. At the t = 28.8767 s condition from the ascent part of the anticipated flight trajectory with a flight Mach number of M ∞ = 5.53 and unit Reynolds number of 4.25 x 10 6 /m, either type of departure from the design condition is shown to have a considerable impact on the structure of the basic state rollup within the region of interest and, hence, also on the amplification characteristics of instability waves within the resulting streaks. Yet, for a yaw angle of β = 4 degrees, the computations indicate only a slight reduction with respect to the peak N-factor of nearly 11 at the design condition of zero degrees yaw and zero degrees angle of attack. In contrast, an angle of attack equal to α = 4 degrees, the peak N-factor decreases to nearly 6 on the leeward side and increases above 16 on the windward side, making the onset of transition highly likely on the windward side. Computations also highlight the role of streak instabilities that originate as Mack mode disturbances and also demonstrate the potential pitfalls in using surface pressure sensors alone to gauge the magnitude of instability amplification.

Boundary layer transition↗

Minimizing manganin/system noise for potential use in small geometry experiments

Manganin gauges are piezo resistive devices often used for pressure measurements on larger, planer impact experiments. These gauges function in this capacity as a result of their ability to change resistance in a consistent fashion relative to the pressure exerted against them. Pressures to 400 kbar have been reliably recorded (H.C. Vantine et al.[1]). Because the mini-manganin is significantly physically smaller than other types, there has been interest in the ability to place these gauges on small geometry (detonator) type experiments. Of primary concern is that the detonator shock front has significant curvature associated with it--especially at small geometries--and that this curvature will cause unknown distortion (stretching) of the manganin gauge and therefore may indicate erroneous data. A problem encountered while configuring this experiment was noise as a result of the proximity and high current levels of the fireset to the manganin gauge. Initial results indicate noise on the order of 130 mV peak-to-peak (p-p) and running as long as the CVR signal from the ringdown charge voltage of 775 V. These noise problems significantly worsened while discharging the full charge voltage of 1500 V on the fireset through the chip slapper.

42 ENGINEERING↗

Flutter of High-Speed Civil Transport Flexible Semispan Model: Time-Frequency Analysis

Time/frequency analysis of fluctuations measured by pressure taps and strain gauges in the experimental studies of the flexible semispan model of a high-speed civil transport wing configuration is performed. The interest is in determining the coupling between the aerodynamic loads and structural motions that led to the hard flutter conditions and loss of the model. The results show that, away from the hard flutter point, the aerodynamic loads at all pressure taps near the wing tip and the structural motions contained the same frequency components. On the other hand, in the flow conditions leading to the hard flutter, the frequency content of the pressure fluctuations near the leading and trailing edges varied significantly. This led to contribution to the structural motions over two frequency ranges. The ratio of these ranges was near 2:1, which suggests the possibility of nonlinear structural coupling.

Chabalko, Christopher C.↗

An Overview of NASA's In-Space Cryogenic Propellant Management Technologies

Future mission planning within NASA continues to include cryogenic propellants for in space transportation, with mission durations ranging from days to years. Between 1995 and the present, NASA has pursued a diversified program of ground-based testing to prepare the various technologies associated with in-space cryogenic fluid management (CFM) for implementation. CFM technology areas being addressed include passive insulation, zero gravity pressure control, zero gravity mass gauging, capillary liquid acquisition devices, and zero boiloff storage. NASA CFM technologies are planned, coordinated, and implemented through the Cryogenic Technology Working Group which is comprised of representatives from the various NASA Centers as well as the National Institute of Standards and Technologies (NIST) and, on selected occasions, the Air Force. An overview of the NASA program and Marshall Space Flight Center (MSFC) roles, accomplishments, and near-term activities are presented herein. Basic CFM technology areas being addressed include passive insulation, zero gravity pressure control, zero gravity mass gauging, capillary liquid acquisition devices, and zero boiloff storage. Recent MSFC accomplishments include: the large scale demonstration of a high performance variable density multilayer insulation (MLI) that reduced the boiloff by about half that of standard MLI; utilization of a foam substrate under MLI to eliminate the need for a helium purge bag system; demonstrations of both spray-bar and axial-jet mixer concepts for zero gravity pressure control; and sub-scale testing that verified an optical sensor concept for measuring liquid hydrogen mass in zero gravity. In response to missions requiring cryogenic propellant storage durations on the order of years, a cooperative effort by NASA's Ames Research Center, Glenn Research Center, and MSFC has been implemented to develop and demonstrate zero boiloff concepts for in-space storage of cryogenic propellants. An MSFC contribution to this cooperative effort is a large-scale demonstration of the integrated operation of passive insulation, destratification/pressure control, and cryocooler (commercial unit) subsystems to achieve zero boiloff storage of liquid hydrogen. Testing is expected during the Summer of 2001.

Tucker, Stephen↗

Wind tunnel test of the 0.015-scale Rockwell International space shuttle vehicle orbiter in the Ames 6 by 6 foot supersonic wind tunnel

Experimental investigations were performed in a 6- by 6-Foot Supersonic wind tunnel on a 0.015-scale model of the Rockwell International space shuttle vehicle (SSV) 2A orbiter. The purpose of the test was to investigate the longitudinal and lateral-directional characteristics of the vehicle. In addition, hinge moments were measured on the rudder and elevons. Buffet onset was investigated using wing trailing edge pressures and a strain gauge instrumented panel mounted in the wing. The model was tested through a Mach range from 0.6 to 2.0 at a constant unit Reynolds number of 2.5 million. Pitch runs were made at angles of attack from minus 2 deg to +26 deg with beta = 0 deg and 5 deg; yaw runs were made in the range from minus 5 deg to 10 deg of sideslip at angles of attack of 0 deg and 10 deg. Static pressures were measured at the fuselage base and the trailing edges of the wing and rudder. Boundary layer transition was fixed for some runs using distributed roughness strips.

Milam, M. D.↗