The use of the electronic system of the feu-34 photo-multiplier as an amplifier of weak ion currents
Use of electronic system of photomultiplier as amplifier of weak ion current in mass spectrometer instruments
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Use of electronic system of photomultiplier as amplifier of weak ion current in mass spectrometer instruments
Heat bending of light pipes for coupling thin organic scintillators to photomultipliers with minimum light loss
Luciferin and luciferase preparation and adenosine triphosphate bioluminescence detection by photomultiplier system for life detection
Spectral transmittance of monochromator determined by repeated runs of photomultiplier tube
Dark current and dark count density correlation for FW-130 photomultiplier tubes
High time resolution polarimeter for laser analysis, beam intensity after passing through analyzers measured by photomultipliers
Scintillation counters with photomultiplier for observing microvariation in cosmic ray intensity
Photomultipliers in DC output mode for extreme UV
Multi-input photomultiplier pulse height photographic recording system using dual beam oscilloscope for cosmic ray experiments
Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.
Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.
Additive manufacturing of polymers is a widely used and growing technology throughout the DOE complex. Composite filaments for Fused Deposition Modeling (FDM) printers are commonly used to enhance material properties such as mechanical strength, operating temperature and chemical resistance. Radio luminescent properties were added to 3D filaments by impregnating clear poly(ethylene terephthalate)-glycol (PETG) with X-ray scintillator powder. X-ray scintillators have unique, narrow emission spectra which can be imaged with low light DSLR cameras, photomultiplier tubes, or spectrometers. Filament Production: 1. Pellets are loaded into the hopper. 2. Temperature and extrusion speed are set on extruder. 3. Extruder turned on and filament is pulled from nozzle along air path to cool. 4. Spooler drive speeds set. 5. Filament is inserted through Filameasure then guided along drive wheels and into traverse. 6. Parameters adjusted to obtain 1.75 mm diameter 7. Filament is inserted into spooler wheel. Traverse speed set and slip nut adjusted to make tight and even roll. From Raw Materials to Printed Part: Clear PETG pellets were dipped in ZnS:Cu scintillator powder to coat pellets. Coated and uncoated pellets were mixed together before inserting into hopper. Filament showed trace amounts of powder and luminesced under UV light. Powder distribution is random and not reproducible thus providing a unique identification marker potentially useful for national security applications. Multiple X-ray scintillators can be arranged in a panel to discriminate incident X-ray photon energies. Variable panel arrangement: pixelated, layered, solid from homogenous filament. Ratio of emission intensities. Response varies with incident photon energy. Spectrally separate scintillators. Scintillators: Yttrium Oxide Europium Doped - Red, Gadolinium Oxysulfide Terbium Doped - Green, Barium Magnesium Aluminate Europium Doped - Blue, Zinc Sulfide Copper Doped - Green. Powder concentrations will need to be increased in the filament for use in the energy discriminating panel. Homogeneity in the filament will be a challenge that can be solved by turning the pellets into a powder and mixing it with scintillator powder prior to extrusion. The panels will be tested using x-ray booths and button sources such as Am-241, Cs-137, and Co-60.
Photocathodes were at the heart of quantum physics development in the early twentieth century and are still used in high technologies devices like night-vision goggles, photomultiplier tubes and particle accelerators. The simplest form of photocathode is a metallic surface,negatively biased,from which electrons are extracted by energetic photons. After a brief description of the photocathode preparation, this chapter will present the latest developments and limitations of metallic and semiconductor photocathodes.
The Schwarzschild-Couder Telescope (SCT) is a telescope concept proposed for the Cherenkov Telescope Array. It employs a dual-mirror optical design to remove comatic aberrations over an 8° field of view, and a high-density silicon photomultiplier camera (with a pixel resolution of 4 arcmin) to record Cherenkov emission from cosmic ray and gamma-ray initiated particle cascades in the atmosphere. Additionally, the prototype SCT (pSCT), comprising a 9.7 m diameter primary mirror and a partially instrumented camera with 1536 pixels, has been constructed at the Fred Lawrence Whipple Observatory. The telescope was inaugurated in January 2019, with commissioning continuing throughout 2019. We describe the first campaign of observations with the pSCT, conducted in January and February of 2020, and demonstrate the detection of gamma-ray emission from the Crab Nebula with a statistical significance of 8.6σ.
A more congested space environment due to increasing space activities introduces new threats to spacecraft operators. Among these threats include hypervelocity impacts from microparticles (< 1 µg) in the form of meteoroids and space debris. These microparticles travel at speeds between 11.2 and 72.8 km/s with respect to the Earth and can impact spacecraft forming a small (~1 µm) and dense (~ 10 26 m -3 ) plasma. This plasma can generate a strong optical emission (impact flash) and a radio frequency (RF) emission. These emissions can lead to spacecraft electrical anomalies when the impacted spacecraft surface (target) carries high electrical potential due to various space weather effects. To understand the microparticle hypervelocity impact plasma and its associated threat to spacecraft electronics, we studied the hypervelocity impact flash expansion geometry under various spacecraft surface electrical conditions. Three high-speed broadband photomultiplier tubes (PMT) are used to capture the temporal evolution of the impact flash and the temporal evolution of the angular distribution of the impact flash expansion geometry in a 3 MV electrostatic dust accelerator during a ground-based experiment. Overall, results indicate that the impact surface electrical condition has a statistically significant influence on the impact flash geometry, and a strong similarity between the impact plasma and flash expansion geometry. Thus, this paper provides new experimental support for the impact flash origin from and connection with the impact plasma, and serves as the first impact flash expansion geometry characterization under various impact surface electrical conditions in a collisionless environment (< 10 -5 Torr).
The Event Plane Detector (EPD) is an upgrade detector to the STAR experiment at RHIC, designed to measure the pattern of forward-going charged particles emitted in a high-energy collision between heavy nuclei. It consists of two highly-segmented disks of 1.2-cm-thick scintillator embedded with wavelength-shifting fiber, coupled to silicon photomultipliers and custom electronics. Finally, we describe the general design of the device, its construction, and performance on the bench and in the experiment.
In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.
In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.