Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Rapid PD-L1 detection in tumors with PET using a highly specific peptide

Molecular imaging can report on the status of the tumor immune microenvironment and guide immunotherapeutic strategies to enhance the efficacy of immune modulation therapies. Imaging agents that can rapidly report on targets of immunomodulatory therapies are few. The programmed death ligand 1 (PD-L1) is an immune checkpoint protein over-expressed in several cancers and contributes to tumor immune suppression. Tumor PD-L1 expression is indicative of tumor response to PD-1 and PD-L1 targeted therapies. Herein, we report a highly specific peptide-based positron emission tomography (PET) imaging agent for PD-L1. We assessed the binding modes of the peptide WL12 to PD-L1 by docking studies, developed a copper-64 labeled WL12 ([{sup 64}Cu]WL12), and performed its evaluation in vitro, and in vivo by PET imaging, biodistribution and blocking studies. Our results show that [{sup 64}Cu]WL12 can be used to detect tumor PD-L1 expression specifically and soon after injection of the radiotracer, to fit within the standard clinical workflow of imaging within 60 min of administration. - Highlights: • A highly specific PD-L1 binding peptide, WL12, was developed as a PET imaging agent. • [{sup 64}Cu]WL12 demonstrates specific binding to PD-L1 in vitro and in vivo. • [{sup 64}Cu]WL12-PET allows PD-L1 detection in cancers within 60 min of administration. • WL12 binding interactions with PD-L1 overlaps with that of PD-1.

60 APPLIED LIFE SCIENCES↗

Microwave-assisted depolymerization of PET over heterogeneous catalysts

The accumulation of plastic waste in the environment is rising and poses a significant environmental and health threat. Polyethylene terephthalate (PET), used mainly in single-use plastic bottles, accounts for a substantial fraction of this waste. The currently employed recycling strategies are inadequate to deal with the global plastic waste problem. PET glycolysis is a promising depolymerization method but has mainly been conducted using homogeneous catalysts; developing active and sustainable catalysts, and more energy-efficient processes remain challenges. Here, in this work, we implement microwave heating in PET glycolysis and identify ZnO as an excellent heterogeneous catalyst. We demonstrate the influence of ZnO's particle size and facet and hydrogen bonding on its activity. Finally, we demonstrate excellent performance for real-world post-consumer PET waste deconstruction with rapid depolymerization into bis(2-hydroxyethyl) terephthalate (BHET), achieving > 95% yields in less than 10 min. Cradle-to-gate life cycle assessment also indicates that BHET produced by ZnO-catalyzed glycolysis has lower global warming potential than the petrochemical-based production and homogeneously-catalyzed glycolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous {sup 68}Ga-DOTATOC-PET/MRI for IMRT Treatment Planning for Meningioma: First Experience

Purpose: To evaluate intensity-modulated radiotherapy (IMRT) treatment planning based on simultaneous positron-emission tomography and magnetic resonance imaging (PET/MRI) of meningioma. Methods and Materials: A meningioma patient was examined prior to radiotherapy with dedicated planning computed tomography (CT), MRI, PET/CT with gallium-68-labeled DOTATOC ({sup 68}Ga-DOTATOC), and simultaneous {sup 68}Ga-DOTATOC-PET/MRI. The first gross target volume (GTV) was defined based on a combination of separate MR and {sup 68}Ga-DOTATOC-PET/CT imaging (GTV{sub PET/CT+MR}). Then, the simultaneous PET/MR images were used to delineate a second GTV (GTV{sub PET/MR}) by following exactly the same delineation strategy. After an isotropic expansion of those volumes by a 4-mm safety margin, the resulting planning target volumes (PTVs) were compared by calculating the intersection volume and the relative complements. A cross-evaluation of IMRT plans was performed, where the treatment plan created for the PTV{sub PET/CT+MR} was applied to the PET/MR-based PTV{sub PET/MR}. Results: Generally, target volumes for IMRT treatment planning did not differ between MRI plus {sup 68}Ga-DOTATOC-PET/CT and simultaneous PET/MR imaging. Only in certain regions of the GTV were differences observed. The overall volume of the PET/MR-based PTV was approximately the same as that obtained from PET/CT data. A small region of infiltrative tumor growth next to the main tumor mass was better visualized with combined PET/MR due to smaller PET voxel sizes and improved recovery. An IMRT treatment plan was optimized for the PTV{sub PET/CT+MR}. The evaluation of this plan with respect to the PTV{sub PET/MR} showed parts of the target volume that would not have received the full radiation dose after delineation of the tumor, based on simultaneous PET/MR. Conclusion: This case showed that differences in target volumes delineated on the basis of separate MR and PET/CT and simultaneous PET/MR may be observed that can have significant consequences for an effectively applied radiotherapy treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Pretreatment FDG-PET SUV Parameters in Head-and-Neck Cancer: Tumor SUV{sub mean} Has Superior Prognostic Value

Purpose: To evaluate the prognostic significance of different descriptive parameters in head-and-neck cancer patients undergoing pretreatment [F-18] fluoro-D-glucose-positron emission tomography (FDG-PET) imaging. Patients and Methods: Head-and-neck cancer patients who underwent FDG-PET before a course of curative intent radiotherapy were retrospectively analyzed. FDG-PET imaging parameters included maximum (SUV{sub max}), and mean (SUV{sub mean}) standard uptake values, and total lesion glycolysis (TLG). Tumors and lymph nodes were defined on co-registered axial computed tomography (CT) slices. SUV{sub max} and SUV{sub mean} were measured within these anatomic regions. The relationships between pretreatment SUV{sub max}, SUV{sub mean}, and TLG for the primary site and lymph nodes were assessed using a univariate analysis for disease-free survival (DFS), locoregional control (LRC), and distant metastasis-free survival (DMFS). Kaplan-Meier survival curves were generated and compared via the log-rank method. SUV data were analyzed as continuous variables. Results: A total of 88 patients was assessed. Two-year OS, LRC, DMFS, and DFS for the entire cohort were 85%, 78%, 81%, and 70%, respectively. Median SUV{sub max} for the primary tumor and lymph nodes was 15.4 and 12.2, respectively. Median SUV{sub mean} for the primary tumor and lymph nodes was 7 and 5.2, respectively. Median TLG was 770. Increasing pretreatment SUV{sub mean} of the primary tumor was associated with decreased disease-free survival (p = 0.01). Neither SUV{sub max} in the primary tumor or lymph nodes nor TLG was prognostic for any of the clinical endpoints. Patients with pretreatment tumor SUV{sub mean} that exceeded the median value (7) of the cohort demonstrated inferior 2-year DFS relative to patients with SUV{sub mean} {<=} the median value of the cohort, 58% vs. 82%, respectively, p = 0.03. Conclusion: Increasing SUV{sub mean} in the primary tumor was associated with inferior DFS. Although not routinely reported, pretreatment SUV{sub mean} may be a useful prognostic FDG-PET parameter and should be further evaluated prospectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Utility of 4D FDG-PET/CT Scans in Radiation Treatment Planning

Purpose: The potential role of four-dimensional (4D) positron emission tomography (PET)/computed tomography (CT) in radiation treatment planning, relative to standard three-dimensional (3D) PET/CT, was examined. Methods and Materials: Ten patients with non-small-cell lung cancer had sequential 3D and 4D [{sup 18}F]fluorodeoxyglucose PET/CT scans in the treatment position prior to radiation therapy. The gross tumor volume and involved lymph nodes were contoured on the PET scan by use of three different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; a technique with a constant threshold of standardized uptake value (SUV) greater than 2.5; and an automatic segmentation technique. For each technique, the tumor volume was defined on the 3D scan (VOL3D) and on the 4D scan (VOL4D) by combining the volume defined on each of the five breathing phases individually. The range of tumor motion and the location of each lesion were also recorded, and their influence on the differences observed between VOL3D and VOL4D was investigated. Results: We identified and analyzed 22 distinct lesions, including 9 primary tumors and 13 mediastinal lymph nodes. Mean VOL4D was larger than mean VOL3D with all three techniques, and the difference was statistically significant (p < 0.01). The range of tumor motion and the location of the tumor affected the magnitude of the difference. For one case, all three tumor definition techniques identified volume of moderate uptake of approximately 1 mL in the hilar region on the 4D scan (SUV maximum, 3.3) but not on the 3D scan (SUV maximum, 2.3). Conclusions: In comparison to 3D PET, 4D PET may better define the full physiologic extent of moving tumors and improve radiation treatment planning for lung tumors. In addition, reduction of blurring from free-breathing images may reveal additional information regarding regional disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metabolic Response on Post-therapy FDG-PET Predicts Patterns of Failure After Radiotherapy for Cervical Cancer

Purpose: To determine the patterns of failure in patients with cervical cancer treated with definitive radiotherapy and evaluated for metabolic response with early posttherapy {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET). Methods and Materials: The records of 238 patients with cervical cancer were reviewed. All patients were treated with a combination of external radiotherapy and intracavitary brachytherapy. Two hundred and nineteen patients (92%) received concurrent chemotherapy. All patients underwent pretreatment FDG-PET, and posttherapy FDG-PET was performed within 8-16 weeks of the completion of radiotherapy. Posttherapy FDG-PET results were categorized as complete metabolic response (CMR), partial metabolic response (PMR), and progressive disease (PD). Failure patterns were categorized as none, isolated local failure (central pelvis {+-} pelvic lymph nodes), distant failure, or combined local plus distant failure. Results: Of the 91 patients (38%) who had a recurrence, 22 had isolated local failures, and 69 had distant failures (49 distant failures and 20 combined local plus distant failures). Of the 173 patients with a CMR, 40 (23%) experienced treatment failure. All 25 patients with PD experienced treatment failure, which was distant in 24 patients (96%). Among the 40 patients with PMR, no failure has been observed for 14 patients (35%). Of the 26 failures within the PMR group, 15 (58%) were limited to the pelvis. Differences in the patterns of failure between the three groups (CMR, PMR, PD) were statistically significant (chi-square test; p < 0.0001). Conclusions: The majority of failures after definitive radiotherapy for cervical cancer include distant failures, even in the setting of concurrent chemotherapy. PMR within the cervix or lymph nodes is more commonly associated with isolated local recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual {sup 18}F-FDG-PET Uptake 12 Weeks After Stereotactic Ablative Radiotherapy for Stage I Non-Small-Cell Lung Cancer Predicts Local Control

Purpose: To investigate the prognostic value of [{sup 18}F]fluorodeoxyglucose positron emission tomography (FDG-PET) uptake at 12 weeks after stereotactic ablative radiotherapy (SABR) for stage I non-small-cell lung cancer (NSCLC). Methods and Materials: From November 2006 to February 2010, 132 medically inoperable patients with proven Stage I NSCLC or FDG-PET-positive primary lung tumors were analyzed retrospectively. SABR consisted of 60 Gy delivered in 3 to 8 fractions. Maximum standardized uptake value (SUV{sub max}) of the treated lesion was assessed 12 weeks after SABR, using FDG-PET. Patients were subsequently followed at regular intervals using computed tomography (CT) scans. Association between post-SABR SUV{sub max} and local control (LC), mediastinal failure, distant failure, overall survival (OS), and disease-specific survival (DSS) was examined. Results: Median follow-up time was 17 months (range, 3-40 months). Median lesion size was 25 mm (range, 9-70 mm). There were 6 local failures: 15 mediastinal failures, 15 distant failures, 13 disease-related deaths, and 16 deaths from intercurrent diseases. Glucose corrected post-SABR median SUV{sub max} was 3.0 (range, 0.55-14.50). Using SUV{sub max} 5.0 as a cutoff, the 2-year LC was 80% versus 97.7% for high versus low SUV{sub max}, yielding an adjusted subhazard ratio (SHR) for high post-SABR SUV{sub max} of 7.3 (95% confidence interval [CI], 1.4-38.5; p = 0.019). Two-year DSS rates were 74% versus 91%, respectively, for high and low SUV{sub max} values (SHR, 2.2; 95% CI, 0.8-6.3; p = 0.113). Two-year OS was 62% versus 81% (hazard ratio [HR], 1.6; 95% CI, 0.7-3.7; p = 0.268). Conclusions: Residual FDG uptake (SUV{sub max} {>=}5.0) 12 weeks after SABR signifies increased risk of local failure. A single FDG-PET scan at 12 weeks could be used to tailor further follow-up according to the risk of failure, especially in patients potentially eligible for salvage surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distribution Atlas of Proliferating Bone Marrow in Non-Small Cell Lung Cancer Patients Measured by FLT-PET/CT Imaging, With Potential Applicability in Radiation Therapy Planning

Purpose: Proliferating bone marrow is exquisitely sensitive to ionizing radiation. Knowledge of its distribution could improve radiation therapy planning to minimize unnecessary marrow exposure and avoid consequential prolonged myelosuppression. [18F]-Fluoro-3-deoxy-3-L-fluorothymidine (FLT)–positron emission tomography (PET) is a novel imaging modality that provides detailed quantitative images of proliferating tissues, including bone marrow. We used FLT-PET imaging in cancer patients to produce an atlas of marrow distribution with potential clinical utility. Methods and Materials: The FLT-PET and fused CT scans of eligible patients with non-small cell lung cancer (no distant metastases, no prior cytotoxic exposure, no hematologic disorders) were reviewed. The proportions of skeletal FLT activity in 10 predefined bony regions were determined and compared according to age, sex, and recent smoking status. Results: Fifty-one patients were studied: 67% male; median age 68 (range, 31-87) years; 8% never smokers; 70% no smoking in the preceding 3 months. Significant differences in marrow distribution occurred between sex and age groups. No effect was detected from smoking in the preceding 3 months. Using the mean percentages of FLT uptake per body region, we created an atlas of the distribution of functional bone marrow in 4 subgroups defined by sex and age. Conclusions: This atlas has potential utility for estimating the distribution of active marrow in adult cancer patients to guide radiation therapy planning. However, because of interindividual variation it should be used with caution when radiation therapy risks ablating large proportions of active marrow; in such cases, individual FLT-PET scans may be required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cohesive and adhesive degradation in PET-based photovoltaic backsheets subjected to ultraviolet accelerated weathering

Delamination between layers in photovoltaic (PV) backsheets is often reported in the literature, causing voids that can collect moisture, diminish module backside heat dissipation, and reduce the backsheet’s effectiveness as a physical barrier. While backsheets with weathering-resistant fluoropolymer outer layers have traditionally been used in modules, more recent backsheets using non-fluoropolymer outer layers, such as polyethylene terephthalate (PET), have been developed. These backsheets have shown signs of premature degradation, and their adhesion degradation, in particular, has not been widely studied. In the present work, the single cantilever beam (SCB) adhesion test was used to quantify the adhesion energy in two commercially available PET-based backsheets. To study the effect of minor changes in formulation, the backsheets were obtained from same manufacturer and product line but during different years. To study the effect of environmental variables on adhesion degradation, the backsheets were subjected to artificial weathering at controlled temperature, humidity, and ultraviolet (UV) radiation in an indoor weathering chamber, and the adhesion energy was quantified at several intervals of exposure time. Layering structure, composition, and adhesion failure mode were compared between the backsheets, using Raman and infrared spectroscopy and thermogravimetric analysis. The results show a large difference in initial (unexposed) adhesion energy between the backsheets, despite very similar structures and compositions. Following exposure, adhesion energy dropped significantly, primarily due to thermo-hydrolytic degradation of the polyurethane (PU)-based adhesive layers. Significant UV-induced adhesion degradation of the PET outer layer surface was also observed. The study represents an important step in understanding adhesion degradation in PET-based backsheets, suggesting ways in which adhesion integrity – and, correspondingly, module service life – can be improved.

14 SOLAR ENERGY↗

Environmental and socio-economic Pareto-front trade-off analysis of U.S. PET packaging material in a circular economy

Various recycling technologies are emerging to implement circular economy in plasticssupply chain systems. However, the environmental and socio-economic trade-offs of in circular economy are not well understood at a systems level. Particularly, quantifying these trade-offs as a function of end-of-life (EOL) management decisions, including transition of recycling technologies, systems level metrics such as circularity, recycled content, and the need for fossil-derived plastics are not well understood. Here, the present study addressed these research gaps by applying a systems analysis modeling approach that utilizes material flow analysis, life cycle assessment, socioeconomic data, and system optimization techniques for polyethylene terephthalate (PET) packaging supply chains in the United States. Pareto-front trade-offs between conflicting environmental and socio-economic impacts as well as those between socioeconomic impacts and circularity were explored using the epsilon constraint method. The Pareto-front trade-off analysis revealed the transition of EOL management strategies for PET packaging systems, including changes in selection of recycling technologies, to aid decision making process by quantifying studied system metrics. Transitioning from environmentally optimal to socio-economically optimal systems led to increased employment (by 17%), wages (by 26%), and revenues (by 6%) but also led to increased global warming potential (GWP; by 65%), energy consumption (by 59%), and reliance on fossil PET in the system (by 78%). Finally, the results show that there is not a unique set of recycling technologies to achieve a sustainable circular economy of PET packaging system, instead it depends on the decision maker’s objectives and targeted metrics of the system.

54 - ENVIRONMENTAL SCIENCES/GLOBAL CLIMATE CHANGE ↗

Factors affecting degradation of polyethylene terephthalate (PET) during pre-flotation conditioning

In general, plastics are exposed to different degrading agents in every procedure involved in their recovery from waste mixture and from subsequent recycling. In this study, two methods of pre-flotation conditioning were used to determine how these methods affect the general properties of the pre-conditioned PET particles to be recovered from the PET-PVC mixture. The first method comprised the conditioning of PET samples using an alkaline solution of nonionic surfactant (Triton X-100) based on the patent by the Goodyear Tire and Rubber Company. The second method, developed in this study, was a conditioning process which used an alkali-less solution of the same nonionic surfactant (Triton X-100) used in the first method. The following analytical methods were used to characterize properties of the pre-conditioned PET samples that were correlated to relative degradation of the samples: differential scanning calorimetry (DSC), for thermal behavior of the samples; FT-IR spectroscopy, for functional groups present in the samples; and, Pohl's method, for carboxyl end-group concentration count. Results show that in addition to water the presence of NaOH in the conditioning solution contributes to the further degradation of the polymer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pilot Study of 64 Cu(I) for PET Imaging of Melanoma

Currently, 64 Cu(II) labeled tracers including 64 CuCl 2 have been widely applied in the research of molecular imaging and therapy. Human copper transporter 1 (hCTR1) is the major high affinity copper influx transporter in mammalian cells, and specially responsible for the transportation of Cu(I) not Cu(II). Thus, we investigated the feasible application of 64 Cu(I) for PET imaging. 64 Cu(II) was reduced to 64 Cu(I) with the existence of sodium L-ascorbate, DL-Dithiothreitol or cysteine. Cell uptake and efflux assay was investigated using B16F10 and A375 cell lines, respectively. Small animal PET and biodistribution studies were performed in both B16F10 and A375 tumor-bearing mice. Compared with 64 Cu(II), 64 Cu(I) exhibited higher cellular uptake by melanoma, which testified CTR1 specially influx of Cu(I). But, due to oxidation reaction in vivo, no significant difference between 64 Cu(I) and 64Cu(II) was observed through PET images and biodistribution. In addition, radiation absorbed doses for major tissues of human were calculated based on the mouse biodistribution. Radiodosimetry calculations for 64/67 Cu(I) and 64/67Cu(II) were similar, which suggested that although melanoma were with high radiation absorbed doses, high radioactivity accumulation by liver and kidney should be noticed for the further application. Thus, 64 Cu(I) should be further studied to evaluate it as a PET imaging radiotracer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recent advances in enzyme engineering for improved deconstruction of poly(ethylene terephthalate) (PET) plastics

In the last ~20 years, a multitude of natural enzymes have been discovered that can catalyze the breakdown of the common plastic poly(ethylene terephthalate) (PET). While enzymatic PET recycling is an attractive alternative end-of-life route for this waste plastic, the enzymes are not yet optimized for efficient and economical industrial use. Here, we discuss recent advances in engineering these PET-degrading enzymes, which include PET, bis(2-hydroxyethyl) terephthalate (BHET), and 2-hydroxyethyl terephthalic acid (MHET) hydrolases, toward industrially-relevant engineering goals. We place emphasis on trends from past efforts in rational and semi-rational design and emerging areas in directed evolution/high throughput screening and computational design for engineering these enzymes.

54 ENVIRONMENTAL SCIENCES↗

Effect of 200 keV Ar{sup +} implantation on optical and electrical properties of polyethyleneterepthalate (PET)

In the present paper we have discussed the effect of 200 keV Ar{sup +} ions on the electrical and optical properties of PET samples. PET samples were implanted with 200 keV Ar{sup +} ions to various doses ranging from 1×10{sup 15} to 1×10{sup 17} Ar{sup +} cm{sup 2}. The changes in the electrical and optical properties of pristine and implanted PET specimens have been studied by using Keithley electrometer and UV-Visible absorption spectroscopy. The electrical conductivity has found to be increased with increasing ion dose. The optical studies have revealed the drastic alterations in optical band gap from 3.63 eV to 1.48 eV and also increase in number of carbon atoms per cluster from 215 to 537. Further, the change in the electrical conductivity and optical band gap has also been correlated with the formation of conductive islands in the implanted layers of PET.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental analysis of the material degradation of PET on a co-rotating twin-screw extruder for varying vacuum pressures

Plastics, starting from inexpensive mass-produced articles to technical high-end applications, are being used in ever more areas of life. The main drivers are their flexible product properties and the resultant broad application possibilities. To be able to offer plastic products inexpensively and conserve the environment at the same time, more and more attention is being paid to plastics recycling. Polyethylene terephthalate – in short PET – is of particular significance here because of its frequent application in the film and packaging industry and its special material properties. The recycling of PET, however, can only be carried out a limited number of times because it’s processing necessarily results in both thermal and mechanical stresses on the material. This is the basis for the reactions at molecular level, which result in a shortening of the molecule chains (material degradation) and exert a negative effect on the product properties. The aim of this study is to identify the factors that influence the material degradation of PET in twin-screw extrusion. To do this, various screw configurations and different speed and throughput conditions are examined in a series of experiments. Furthermore, material specimens are removed along the length of the screw in order to evaluate the influence of individual screw sections. By determining the intrinsic viscosity of the specimens, it is possible to measure the mean molecular weight and thus the material damage. Based on the test results, guidelines are drawn up for the compounding of PET so as to ensure as little damage as possible to the material.

36 MATERIALS SCIENCE↗

PhytoPET: Design and initial results of modular PET for plant biology

We have developed a positron emission tomography (PET) system designed specifically for plant imaging in Phytotron at Duke University. Initial evaluation of a PhytoPET system to image the biodistribution of the positron emitting tracer {sup 11}C in live plants is presented. The mechanical arrangement of the detectors is designed to accommodate the unpredictable and random distribution in space of the plant parts such as stems, leaves, and roots. Prototyping such a system requires a completely new PET system design strategy different from preclinical and clinical applications. This PhytoPET design allows flexible arrangements of PET detectors based on individual standalone detector modules built from single 5 cm × 5 cm Hamamatsu H8500 position sensitive photomultiplier tubes. Each H8500 is coupled to a L YSO:Ce scintillator array composed of 48 × 48 elements that are 10 mm thick with a 1 mm pitch. Initial results provide planar PET images from two different arrangements (1 × 4 or 2 × 2) for flexible imaging capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the spline reconstruction technique for PET

Purpose: The spline reconstruction technique (SRT), based on the analytic formula for the inverse Radon transform, has been presented earlier in the literature. In this study, the authors present an improved formulation and numerical implementation of this algorithm and evaluate it in comparison to filtered backprojection (FBP). Methods: The SRT is based on the numerical evaluation of the Hilbert transform of the sinogram via an approximation in terms of “custom made” cubic splines. By restricting reconstruction only within object pixels and by utilizing certain mathematical symmetries, the authors achieve a reconstruction time comparable to that of FBP. The authors have implemented SRT in STIR and have evaluated this technique using simulated data from a clinical positron emission tomography (PET) system, as well as real data obtained from clinical and preclinical PET scanners. For the simulation studies, the authors have simulated sinograms of a point-source and three digital phantoms. Using these sinograms, the authors have created realizations of Poisson noise at five noise levels. In addition to visual comparisons of the reconstructed images, the authors have determined contrast and bias for different regions of the phantoms as a function of noise level. For the real-data studies, sinograms of an{sup 18}F-FDG injected mouse, a NEMA NU 4-2008 image quality phantom, and a Derenzo phantom have been acquired from a commercial PET system. The authors have determined: (a) coefficient of variations (COV) and contrast from the NEMA phantom, (b) contrast for the various sections of the Derenzo phantom, and (c) line profiles for the Derenzo phantom. Furthermore, the authors have acquired sinograms from a whole-body PET scan of an {sup 18}F-FDG injected cancer patient, using the GE Discovery ST PET/CT system. SRT and FBP reconstructions of the thorax have been visually evaluated. Results: The results indicate an improvement in FWHM and FWTM in both simulated and real point-source studies. In all simulated phantoms, the SRT exhibits higher contrast and lower bias than FBP at all noise levels, by increasing the COV in the reconstructed images. Finally, in real studies, whereas the contrast of the cold chambers are similar for both algorithms, the SRT reconstructed images of the NEMA phantom exhibit slightly higher COV values than those of FBP. In the Derenzo phantom, SRT resolves the 2-mm separated holes slightly better than FBP. The small-animal and human reconstructions via SRT exhibit slightly higher resolution and contrast than the FBP reconstructions. Conclusions: The SRT provides images of higher resolution, higher contrast, and lower bias than FBP, by increasing slightly the noise in the reconstructed images. Furthermore, it eliminates streak artifacts outside the object boundary. Unlike other analytic algorithms, the reconstruction time of SRT is comparable with that of FBP. The source code for SRT will become available in a future release of STIR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-9A-03: Simultaneous Deconvolution and Segmentation for PET Tumor Delineation Using a Variational Method

Purpose: To implement a new method that integrates deconvolution with segmentation under the variational framework for PET tumor delineation. Methods: Deconvolution and segmentation are both challenging problems in image processing. The partial volume effect (PVE) makes tumor boundaries in PET image blurred which affects the accuracy of tumor segmentation. Deconvolution aims to obtain a PVE-free image, which can help to improve the segmentation accuracy. Conversely, a correct localization of the object boundaries is helpful to estimate the blur kernel, and thus assist in the deconvolution. In this study, we proposed to solve the two problems simultaneously using a variational method so that they can benefit each other. The energy functional consists of a fidelity term and a regularization term, and the blur kernel was limited to be the isotropic Gaussian kernel. We minimized the energy functional by solving the associated Euler-Lagrange equations and taking the derivative with respect to the parameters of the kernel function. An alternate minimization method was used to iterate between segmentation, deconvolution and blur-kernel recovery. The performance of the proposed method was tested on clinic PET images of patients with non-Hodgkin's lymphoma, and compared with seven other segmentation methods using the dice similarity index (DSI) and volume error (VE). Results: Among all segmentation methods, the proposed one (DSI=0.81, VE=0.05) has the highest accuracy, followed by the active contours without edges (DSI=0.81, VE=0.25), while other methods including the Graph Cut and the Mumford-Shah (MS) method have lower accuracy. A visual inspection shows that the proposed method localizes the real tumor contour very well. Conclusion: The result showed that deconvolution and segmentation can contribute to each other. The proposed variational method solve the two problems simultaneously, and leads to a high performance for tumor segmentation in PET. This work was supported in part by National Natural Science Foundation of China (NNSFC), under Grant Nos. 60971112 and 61375018, and Fundamental Research Funds for the Central Universities, under Grant No. 2012QN086. Wei Lu was supported in part by the National Institutes of Health (NIH) Grant No. R01 CA172638.

62 RADIOLOGY AND NUCLEAR MEDICINE↗