Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARALLEL PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Measurement and Analysis of Buildup Region Dose for Open Field Photon Beams (Cobalt-60 through 24 MV)

The central axis depth dose in the build-up region (surface to d{sub max}) of single open field photon beams (cobalt-60 through 24 MV) has been measured utilizing parallel plate and extrapolation chamber methodology. These data were used to derive, for a prescription dose of 100 cGy, values of surface dose, the maximum value of dose along the central axis (D{sub max}) and the depth (nearest the surface) at which 90% of the prescription dose occurs (d{sub 90}). For both single and parallel opposed pair (POP) open field configurations, data are presented at field sizes of 5 × 5, 15 × 15 and 25 × 25 cm{sup 2} for prescription depths of 10, 15 and 20 cm (midplane for POP). For the treatment machines, field sizes, and prescription depths studied, it is possible to conclude that: for single open field irradiation, surface dose values (as a percentage of the prescription dose) can be either low (<10%) or comparable to the prescription dose itself; for POP open fields, surface dose values are relatively independent of photon energy and midplane depth, and range between 30% and 70% of prescription dose, being principally dependent on field size; the depth of the initial 90 cGy point for a prescription dose of 100 cGy, d{sub 90}, was larger for POP fields. For either single or POP open field treatments, d{sub 90} was always less than 22 mm, while for 6 MV or less, values of d{sub 90} were less than 4 mm; D{sub max} values can be very large (e.g., above 300 cGy) for certain treatment situations and are reduced significantly for POP treatments; for open field POP treatments, the percent reduction in D{sub max} with each increment in beam energy above 10 MV is reduced over that seen at 10 MV or less and, possibly, this further reduction may be clinically insignificant; for open field POP treatments, changes in surface dose, d{sub 90} and D{sub max} with beam energy above 10 MV do not suggest, with regard to these specific build-up curve parameters, any obvious advantage for treatment with beam energies greater than 10 MV for the specific machines and situations studied.

61 RADIATION PROTECTION AND DOSIMETRY↗

Wakefield computations for a corrugated pipe as a beam dechirper for FEL applications

A beam “dechirper” based on a corrugated, metallic vacuum chamber has been proposed recently to cancel residual energy chirp in a beam before it enters the undulator in a linac-based X-ray FEL. Rather than the round geometry that was originally proposed, we consider a pipe composed of two parallel plates with corrugations. The advantage is that the strength of the wake effect can be tuned by adjusting the separation of the plates. The separation of the plates is on the order of millimeters, and the corrugations are fractions of a millimeter in size. The dechirper needs to be meters long in order to provide sufficient longitudinal wakefield to cancel the beam chirp. Considerable computation resources are required to determine accurately the wakefield for such a long structure with small corrugation gaps. Combining the moving window technique and parallel computing using multiple processors, the time domain module in the parallel finite-element electromagnetic suite ACE3P allows efficient determination of the wakefield through convergence studies. In this paper, we will calculate the longitudinal, dipole and quadrupole wakefields for the dechirper and compare the results with those of analytical and field matching approaches.

43 PARTICLE ACCELERATORS↗

Energetic ion, atom, and molecule reactions and excitation in low-current H{sub 2} discharges: H{sub a}lpha Doppler profiles

Absolute spectral emissivities for Doppler broadened H{sub a}lpha profiles are measured and compared with predictions of energetic hydrogen ion, atom, and molecule behavior in low-current electrical discharges in H{sub 2} at very high electric field E to gas density N ratios E/N and low values of Nd, where d is the parallel-plate electrode separation. These observations reflect the energy and angular distributions for the excited atoms and quantitatively test features of multiple-scattering kinetic models in weakly ionized hydrogen in the presence of an electric field that are not tested by the spatial distributions of H{sub a}lpha emission. Absolute spectral intensities agree well with predictions. Asymmetries in Doppler profiles observed parallel to the electric field at 4<=E/N<=20 kTd result primarily from excitation by fast H atoms directed toward the cathode and diffusely reflected from the cathode. (1 Td=10{sup -21} V m{sup 2}) The effects of reflection of hydrogen particles and of changes with cathode material are modeled accurately without adjustable parameters. Maximum measured wavelength shifts result from acceleration of H{sup +} ions and charge transfer to fast H atoms. The Doppler profiles are consistent with models of reactions among H{sup +}, H{sub 2}{sup +}, H{sub 3}{sup +}, H, and H{sub 2} leading to fast H atoms and then fast excited H(n=3) atoms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Poisson-Boltzmann theory for two parallel uniformly charged plates

We solve the nonlinear Poisson-Boltzmann equation for two parallel and like-charged plates both inside a symmetric electrolyte, and inside a 2:1 asymmetric electrolyte, in terms of Weierstrass elliptic functions. From these solutions we derive the functional relation between the surface charge density, the plate separation, and the pressure between plates. For the one plate problem, we obtain exact expressions for the electrostatic potential and for the renormalized surface charge density, both in symmetric and in asymmetric electrolytes. For the two plate problems, we obtain new exact asymptotic results in various regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inter-digital capacitive sensor for evaluating cable jacket and insulation aging

An inter-digital capacitive (TDC) sensor has previously been used to measure dielectric properties of cable insulation polymer material when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket. The dielectric properties of many cable jacket and insulation polymers are known to change due to thermal and radiation exposure-related damage. These dielectric properties frequently track with other measures of cable aging, such as tensile elongation-at-break and indenter modulus that have been broadly established as cable insulation polymer assessment methods. The external jacket of a cable is likely to have a different permittivity from the underlying insulation, and frequently the jacket material exhibits more severe damage than the insulation material due to environmental exposure. Because the jacket serves primarily to guard the cable during installation, as long as the underlying insulation condition is acceptable, the jacket condition is relatively unimportant in service. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, a set of tools has been developed including (1) a parallel-plate sensor to directly measure the permittivity spectrum of flat sheet material and (2) an TDC and fixture to measure the effect of cable polymer dielectric property change on the sensor response. The TDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. The electrodes are printed on one side of a flexible substrate that can be conformed to the surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad-frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. By finite element modeling (FEM) and experimentation, this study investigates the effect of tine spacing and other design parameters associated with the TDC on the voltage (potential) distribution and electric field depth of penetration. The TDC measurement of an unshielded ethylene-propylene rubber (EPR)-insulated cable is shown to track with the degree of aging and quantities obtained by established methods. For jacketed cable systems, the TDC response is dominated by the jacket but, by analyzing measurements from TDC sensors with different depths-of-field penetration into the cable under test, the influence of the chlorinated polyethylene (CPE) cable jacket material degradation can be separated from an assessment of the cable insulation thereby enabling assessment of the insulation beneath/through the jacket.

Cable NDE, Interdigital Capacitance, Cable test↗

Experimental verification of gain drop due to general ion recombination for a carbon-ion pencil beam

Purpose: Accurate dose measurement in radiotherapy is critically dependent on correction for gain drop, which is the difference of the measured current from the ideal saturation current due to general ion recombination. Although a correction method based on the Boag theory has been employed, the theory assumes that ionized charge density in an ionization chamber (IC) is spatially uniform throughout the irradiation volume. For particle pencil beam scanning, however, the charge density is not uniform, because the fluence distribution of a pencil beam is not uniform. The aim of this study was to verify the effect of the nonuniformity of ionized charge density on the gain drop due to general ion recombination. Methods: The authors measured the saturation curve, namely, the applied voltage versus measured current, using a large plane-parallel IC and 24-channel parallel-plate IC with concentric electrodes. To verify the effect of the nonuniform ionized charge density on the measured saturation curve, the authors calculated the saturation curve using a method which takes into account the nonuniform ionized charge density and compared it with the measured saturation curves. Results: Measurement values of the different saturation curves in the different channels of the concentric electrodes differed and were consistent with the calculated values. The saturation curves measured by the large plane-parallel IC were also consistent with the calculation results, including the estimation error of beam size and of setup misalignment. Although the impact of the nonuniform ionized charge density on the gain drop was clinically negligible with the conventional beam intensity, it was expected that the impact would increase with higher ionized charge density. Conclusions: For pencil beam scanning, the assumption of the conventional Boag theory is not valid. Furthermore, the nonuniform ionized charge density affects the prediction accuracy of gain drop when the ionized charge density is increased by a higher dose rate and/or lower beam size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Two-dimensional expansion of finite-size barium photoplasma in an electrostatic field

Two-dimensional evolution of finite-size barium photoplasma, produced using multistep-resonant ionization is experimentally investigated in an externally applied electrostatic field. Several processes like bulk motion, ambipolar diffusion, Coulomb repulsion, Child-Langmuir flux, bounded diffusion, etc. that contribute to its expansion, have been identified. They are quantified with the help of signals recorded by Faraday cups, electrodes and plates and by two-dimensional particle-in-cell simulation. These processes are superimposed and their relative magnitudes decide the evolution of the photoions. When external field is dominant, a significant fraction of ions reach the cathode with negligible vertical spread and the plasma motion can be considered as one-dimensional. However, when plasma collective effects are dominant, then the different mechanisms become comparable and the photoplasma expands in two dimensions. The spread of photoions at different locations in parallel plate geometry is determined as a function of plasma density and compared with simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-J-146: Experimental Validation of 6 MV Photon PDD in Parallel Magnetic Field Calculated by EGSnrc

Purpose: Integrated linac-MR systems are uniquely suited for real time tumor tracking during radiation treatment. Understanding the magnetic field dose effects and incorporating them in treatment planning is paramount for linac-MR clinical implementation. We experimentally validated the EGSnrc dose calculations in the presence of a magnetic field parallel to the radiation beam travel. Methods: Two cylindrical bore electromagnets produced a 0.21 T magnetic field parallel to the central axis of a 6 MV photon beam. A parallel plate ion chamber was used to measure the PDD in a polystyrene phantom, placed inside the bore in two setups: phantom top surface coinciding with the magnet bore center (183 cm SSD), and with the magnet bore’s top surface (170 cm SSD). We measured the field of the magnet at several points and included the exact dimensions of the coils to generate a 3D magnetic field map in a finite element model. BEAMnrc and DOSXYZnrc simulated the PDD experiments in parallel magnetic field (i.e. 3D magnetic field included) and with no magnetic field. Results: With the phantom surface at the top of the electromagnet, the surface dose increased by 10% (compared to no-magnetic field), due to electrons being focused by the smaller fringe fields of the electromagnet. With the phantom surface at the bore center, the surface dose increased by 30% since extra 13 cm of air column was in relatively higher magnetic field (>0.13T) in the magnet bore. EGSnrc Monte Carlo code correctly calculated the radiation dose with and without the magnetic field, and all points passed the 2%, 2 mm Gamma criterion when the ion chamber’s entrance window and air cavity were included in the simulated phantom. Conclusion: A parallel magnetic field increases the surface and buildup dose during irradiation. The EGSnrc package can model these magnetic field dose effects accurately. Dr. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

X-ray scattering in the vorticity direction and rheometry from confined fluids

An X-ray flexure-based microgap rheometer (X-FMR) has been designed for combining rheology and in situ small-angle X-ray scattering from the vorticity plane. The gap distance can be varied continuously from 500 μm down to several μm, which provides the unique possibility to generate a strong confinement for many complex fluids. A singular advantage of this setup is the possibility to directly probe the vorticity direction of the flow field with a microfocus X-ray beam and to probe the structural response of the fluid to combined shear and confinement in the vorticity plane. The sliding-plate setup operates over a wide range of shear rates of γ{sup .} = 10{sup −3}–10{sup 3} s{sup −1} and strains in the range of 10{sup −4}–10{sup 2}. The flexure-based bearing maintains the plate parallelism within 10{sup −5} rad. The X-FMR requires very small sample volumes on the order of 10 μl. The applicability of the device is demonstrated here with limited examples of a nematic suspension of fd virus (rods), and a crystalline suspension containing sterically stabilized polystyrene-butylacrylate latex particles.

42 ENGINEERING↗

ZBLAN Viscosity Instrumentation

The past year's contribution from Dr. Kaukler's experimental effort consists of these 5 parts: a) Construction and proof-of-concept testing of a novel shearing plate viscometer designed to produce small shear rates and operate at elevated temperatures; b) Preparing nonlinear polymeric materials to serve as standards of nonlinear Theological behavior; c) Measurements and evaluation of above materials for nonlinear rheometric behavior at room temperature using commercial spinning cone and plate viscometers available in the lab; d) Preparing specimens from various forms of pitch for quantitative comparative testing in a Dynamic Mechanical Analyzer, Thermal Mechanical Analyzer; and Archeological Analyzer; e) Arranging to have sets of pitch specimens tested using the various instruments listed above, from different manufacturers, to form a baseline of the viscosity variation with temperature using the different test modes offered by these instruments by compiling the data collected from the various test results. Our focus in this project is the shear thinning behavior of ZBLAN glass over a wide range of temperature. Experimentally, there are no standard techniques to perform such measurements on glasses, particularly at elevated temperatures. Literature reviews to date have shown that shear thinning in certain glasses appears to occur, but no data is available for ZBLAN glass. The best techniques to find shear thinning behavior require the application of very low rates of shear. In addition, because the onset of the thinning behavior occurs at an unknown elevated temperature, the instruments used in this study must provide controlled low rates of shear and do so for temperatures approaching 600 C. In this regard, a novel shearing parallel plate viscometer was designed and a prototype built and tested.

Kaukler, William↗

Formation of Imploding Plasma Liners for HEDP and MIF Application

Plasma jets with high density and velocity have a number of important applications in fusion energy and elsewhere, including plasma refueling, disruption mitigation in tokamaks, magnetized target fusion, injection of momentum into centrifugally confined mirrors, plasma thrusters, and high energy density plasmas (HEDP). In Magneto-Inertial Fusion (MIF), for example, an imploding material liner is used to compress a magnetized plasma to fusion conditions and to confine the resulting burning plasma inertially to obtain the necessary energy gain. The imploding shell may be solid, liquid, gaseous, or a combination of these states. The presence of the magnetic field in the target plasma suppresses thermal transport to the plasma shell, thus lowering the imploding power needed to compress the target to fusion conditions. This allows the required imploding momentum flux to be generated electromagnetically using off-the-shelf pulsed power technology. Practical schemes for standoff delivery of the imploding momentum flux are required and are open topics for research. One approach for accomplishing this, called plasma jet driven magneto-inertial fusion (PJMIF), uses a spherical array of pulsed plasma guns to create a spherically imploding shell of very high velocity, high momentum flux plasma. This approach requires development of plasma jet accelerators capable of achieving velocities of 50-200 km/s with very precise timing and density profiles, and with high total mass and density. Low-Z plasma jets would require the higher velocities, whereas very dense high-Z plasma shells could achieve the goal at velocities of only 50-100 km/s. In this report, we describe our work to develop the pulsed plasma gun technology needed for an experimental scientific exploration of the PJMIF concept, and also for the other applications mentioned earlier. The initial goal of a few hundred of hydrogen at 200 km/s was eventually replaced with accelerating 8000 μg of argon or xenon to 50 km/s for the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). Initial work used existing computational and analytical tools to develop and refine a specific plasma gun concept having a novel tapered coaxial electromagnetic accelerator contour with an array of symmetric ablative plasma injectors. The profile is designed to suppress the main barrier to success in coaxial guns, namely the blow-by instability in which the arc slips past and outruns the bulk of the plasma mass. Efforts to begin developing a set of annular non-ablative plasma injectors for the coaxial gun, in order to accelerate pure gases, resulted in development of linear parallel-plate MiniRailguns that turned out to work well as plasma guns in their own right and we subsequently chose them for an initial plasma liner experiment on the PLX facility at LANL. This choice was mainly driven by cost and schedule for that particular experiment, while longer term goals still projected use of coaxial guns for reactor-relevant applications for reasons of better symmetry, lower impurities, more compact plasma jet formation, and higher gun efficiency. Our efforts have focused mainly on 1) developing various plasma injection systems for both coax and linear railguns and ensuring they work reliably with the accelerator section, 2) developing a suite of plasma and gun diagnostics, 3) performing computational modeling to design and refine the plasma guns, 4) establishing a research facility dedicated to plasma gun development, and finally, 5) developing plasma guns and associated pulse power systems capable of achieving these goals and installing and testing the first two gun sets on the PLX facility at LANL. During the second funding cycle for this program, HyperV joined in a collaborative effort with LANL, the University of Alabama at Huntsville, and the University of New Mexico to perform a plasma liner experiment (PLX) to investigate the physics and technology of forming spherically imploding plasma liners. HyperV’s tasks focused on developing the plasma guns and associated pulse power systems required for the 30 gun experiment at LANL. Unfortunately, funding for the entire PLX collaborative project was terminated after only two years of the four year project due to program funding realignments which necessitated recompeting the project in midstream. Despite the loss of funding, HyperV installed two Mark1 guns and pulsed power systems on PLX, and jet characterization and merging experiments were subsequently successfully performed at LANL by the PLX Team. In parallel with those PLX experiments, HyperV continued its efforts to develop a plasma gun capable of meeting the PLX goal of 8 mg of argon at 50 km/s. HyperV was ultimately successful in this effort, demonstrating 10.8 mg at 52.8 km/s and 7.5 mg at 62.4 km/s with the Mark2 MiniRailgun.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Substrate-Wide Confined Shear Alignment of Carbon Nanotubes for Thin Film Transistors

To exploit their charge transport properties in transistors, semiconducting carbon nanotubes must be assembled into aligned arrays comprised of individualized nanotubes at optimal packing densities. However, achieving this control on the wafer-scale is challenging. Here, solution-based shear in substrate-wide, confined channels is investigated to deposit continuous films of well-aligned, individualized, semiconducting nanotubes. Polymer-wrapped nanotubes in organic ink are forced through sub-mm tall channels, generating shear up to 10 000 s -1 uniformly aligning nanotubes across substrates. The ink volume and concentration, channel height, and shear rate dependencies are elucidated. Optimized conditions enable alignment within a ±32° window, at 50 nanotubes µm-1, on 10 × 10 cm 2 substrates. Transistors (channel length of 1–5 µm) are fabricated parallel and perpendicular to the alignment. The parallel transistors perform with 7× faster charge carrier mobility (101 and 49 cm 2 V -1 s -1 assuming array and parallel-plate capacitances, respectively) with high on/off ratio of 105. The spatial uniformity varies ±10% in density, ±2° in alignment, and ±7% in mobility. Deposition occurs within seconds per wafer, and further substrate scaling is viable. Compared to random networks, aligned nanotube films promise to be a superior platform for applications including sensors, flexible/stretchable electronics, and light emitting and harvesting devices.

36 MATERIALS SCIENCE↗

Proximity Ferroelectricity in Compositionally Graded Structures

Proximity ferroelectricity is a novel paradigm for inducing ferroelectricity in a non-ferroelectric polar material, such as AlN or ZnO that are typically unswitchable with an external field below their dielectric breakdown field. When placed in direct contact with a thin switchable ferroelectric layer (such as Al 1-x Sc x N or Zn 1-x Mg x O), they become a practically switchable ferroelectric. Using the thermodynamic Landau-Ginzburg-Devonshire theory, in this work, we perform the finite element modeling of the polarization switching in the compositionally graded AlN-Al 1-x Sc x N, ZnO-Zn 1-x Mg x O, and MgO-Zn 1-x Mg x O structures sandwiched in both a parallel-plate capacitor geometry as well as in a sharp probe-planar electrode geometry. We reveal that the compositionally graded structure allows the simultaneous switching of spontaneous polarization in the whole system by a coercive field significantly lower than the electric breakdown field of unswitchable polar materials. The physical mechanism is the depolarization electric field determined by the gradient of chemical composition “x”. The field lowers the steepness of the switching barrier in the otherwise unswitchable parts of the compositionally graded AlN-Al 1-x Sc x N and ZnO-Zn 1-x Mg x O structures. In the MgO-like regions of the compositionally graded MgO-Zn 1-x Mg x O structure, a shallow double-well free energy potential emerges. Proximity ferroelectric switching of the compositionally graded structures placed in the probe-electrode geometry occurs due to nanodomain formation under the tip. We predict that a gradient of chemical composition “x” significantly lowers effective coercive fields of the compositionally graded AlN-Al 1-x Sc x N and ZnO-Zn 1-x Mg x O structures compared to the coercive fields of the corresponding multilayers with a uniform chemical composition in each layer. A tip-induced switching further lowers the coercive field, enabling control of ferroelectric domains in otherwise unswitchable compositionally graded structures, which can provide nanoscale domain control for memory, actuation, sensing, and optical applications.

36 MATERIALS SCIENCE↗

Process Variability Effects on Tensile Response in Injection Molded, Fluorinated Thermoplastics

The mechanical properties of fluorinated thermoplastics (i.e., tensile strength and elongation) can vary with changes in injection molding processing parameters. Four fluoropolymers are examined: poly(vinylidene fluoride) (PVDF) and random poly(vinylidene fluoride-co-chlorotrifluoroethylene) (PVDF-CTFE) with three CTFE concentrations. Dog bones were manufactured with various cylinder dwell times and mold cooling times to assess the manufacturing sensitivity to the tensile response. Dwell and cooling times increasingly impact mechanical performance as CTFE concentration increases. Specimens exhibit higher tensile strength as a function of injection order. The first injected specimen exhibits the lowest tensile strength and highest elongation in all copolymers. This trend becomes more pronounced among fluoropolymers with higher CTFE concentration and lower weight-averaged molecular weight. Parallel plate rheology was used to obtain the zero-shear viscosity as a function of material type, process, and injection order. We found that in the copolymers, the first injected sample exhibited a lower zero-shear viscosity than the next, which indicates a lower molecular weight in the first injected specimen. This phenomenon was not presented for the PVDF homopolymer. Copolymer mechanical uncertainties are hypothesized to result from the shorter molecular weight chains extruding out of the specimens' sides as a flash due to higher mobility with CTFE segments.

36 MATERIALS SCIENCE↗

Modeling electrokinetics in ionic liquids: General

Using direct numerical simulations we provide a thorough study on the electrokinetics of ionic liquids. In particular, the modfied Poisson-Nernst-Planck (MPNP) equations are solved to capture the crowding and overscreening effects that are the characteristics of an ionic liquid. For modeling electrokinetic flows in an ionic liquid, the MPNP equations are coupled with the Navier-Stokes equations to study the coupling of ion transport, hydrodynamics, and electrostatic forces. Specifically, we consider the ion transport between two parallel plates, charging dynamics in a 2D straight-walled pore, electro-osmotic ow in a nano-channel, electroconvective instability on a plane ion-selective surface, and electroconvective ow on a curved ion-selective surface. We discuss how the crowding and overscreening effects and their interplay affect the electrokinetic behaviors of ionic liquids in these application problems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hierarchical Phased-Array Antennas Coupled to Al KIDs: A Scalable Architecture for Multi-band Millimeter/Submillimeter Focal Planes

We present the optical characterization of two-scale hierarchical phased-array antenna kinetic inductance detectors (KIDs) for millimeter/submillimeter wavelengths. Our KIDs have a lumped-element architecture with parallel plate capacitors and aluminum inductors. The incoming light is received with a hierarchical phased array of slot dipole antennas, split into 4 frequency bands (between 125 GHz and 365 GHz) with on-chip lumped-element band-pass filters, and routed to different KIDs using microstriplines. Individual pixels detect light for the 3 higher-frequency bands (190–365 GHz), and the signals from four individual pixels are coherently summed to create a larger pixel detecting light for the lowest frequency band (125–175 GHz). The spectral response of the band-pass filters was measured using Fourier transform spectroscopy (FTS), the far-field beam pattern of the phased-array antennas was obtained using an infrared source mounted on a 2-axis translating stage, and the optical efficiency of the KIDs was characterized by observing loads at 294 K and 77 K. We report on the results of these three measurements.

47 OTHER INSTRUMENTATION↗

Surface Current Approximation in Certain Problems of the Classical Theory of Superconductivity

The problems of the behavior of superconducting infinite plane-parallel plate and cylinder in an external magnetic field are solved in the approximation of the model of surface currents. The latter, in contrast to the conventional notation, enter as the currents of superconducting electrons into the boundary conditions for the magnetic induction. Surface currents are understood as the volumetric current flowing in the thickness of the near-surface layer, which is associated with the thickness of the London penetration depth of the field and currents into the thickness of the superconductor. It is shown that in this case, a jump in the magnetic quantities occurs at this thickness. The calculated average magnetization of the magnet is reduced to the strength of the external field. The proportionality coefficient, which is reasonable to call the mean magnetic susceptibility, turns out to be not exactly equal to –1, but has a slightly less value, because the field does not weaken immediately. The possibilities of experimental verification of the obtained effect are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Channel Flow of a Concentrated Suspension

A theory for creeping flow of concentrated suspensions is described that takes into account the fluctuations of particles about their mean motion. The intensity of the velocity fluctuations is characterized by an internal field analogous to the temperature in classical kinetic theories, and governed by a balance law for the fluctuation energy. Explicit forms are posed for the constitutive models relating the viscosity, conductivity, dissipation, and pressure to the temperature and mean interparticle separation. Flow between parallel plates is considered; exact and approximate solutions are found for the temperature and separation fields. The mean velocity is given in terms of a simple integral involving the temperature. The solution exhibits qualitative behavior comparable to experimental observations: particle fluctuations and the mean shearing are confined to a region near the channel wall, while a plug-like region prevails in the center.

42 ENGINEERING↗