A Novel Triple Inverter Design for CMOS Clocks and Oscillators.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Machine condition monitoring has been proven to reduce machine downtime and increase productivity. The state-of-the-art research uses vibration monitoring for tasks such as maintenance and tool wear prediction. A less explored aspect is how vibration monitoring might be used to monitor equipment sensitive to vibration. In a manufacturing environment, one example of where this might be needed is in monitoring the vibration of optical linear encoders used in high-precision machine tools and coordinate measuring machines. Monitoring the vibration of sensitive equipment presents a unique case for vibration monitoring because an accurate calculation of the maximum sustained vibration is needed, as opposed to extracting trends from the data. To do this, techniques for determining sustained peaks in vibration signals are needed. Here, this work fills this gap by formalizing and testing methods for determining sustained vibration amplitudes. The methods are tested on simulated signals based on experimental data. Results show that processing the signal directly with the novel Expire Timer method produces the smallest amounts of error on average under various test conditions. Additionally, this method can operate in real-time on streaming vibration data.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
No abstract provided
Abstract not provided.
A ladder oscillator composed of capacitive and inductive impedances connected together to form a ladder network which has a chosen number N oscillation modes at N different frequencies. Each oscillation mode is characterized by a unique standing wave voltage pattern along the nodes of the ladder oscillator, with the mode in which the ladder oscillator is oscillating being determinable from the amplitudes or phase of the oscillations at the nodes. A logic circuit may be connected to the nodes of the oscillator to compare the phases of selected nodes and thereby determine which mode the oscillator is oscillating in. A ladder oscillator composed of passive capacitive and inductive impedances can be utilized as a frequency recognition device, since the passive ladder oscillator will display the characteristic standing wave patterns if an input signal impressed upon the ladder oscillator is close to one of the mode frequencies of the oscillator. A CL ladder oscillator having series capacitive impedances and shunt inductive impedances can exhibit sustained and autonomous oscillations if active nonlinear devices are connected in parallel with the shunt inductive impedances. The active CL ladder oscillator can be synchronized to input frequencies impressed upon the oscillator, and will continue to oscillate after the input signal has been removed at a mode frequency which is, in general, nearest to the input signal frequency. Autonomous oscillations may also be obtained as desired from the active CL ladder oscillator at the mode frequencies.
The results of the research conducted under this grant are presented in detail in three Master theses, by Heinrich, Balow, and Broeren. Additional analysis of the experimental data can be found in two AIAA Journal articles and two conference papers. Citations for all of the studies' publications can be found in the bibliography which is attached. The objective of Heinrich's study was to document the low-frequency flow oscillation on the LRN-1007 airfoil, which had been previously observed at low Reynolds number, to determine its origin, and explore the phenomenon at higher Reynolds number. Heinrich performed detailed flow visualization on the airfoil using surface fluorescent oil and laser-sheet off-body visualization. A large leading-edge separation bubble and trailing-edge separation was identified on the airfoil just prior to the onset of the unsteady stall flow oscillation. From the laser-sheet data, the unsteady flow appeared as a massive boundary-layer separation followed by flow reattachment. Hot-wire data were taken in the wake to identify the presence of the flow oscillation and the dominant frequency. The oscillation was found in the flow from a Reynolds number of 0.3 to 1.3 x 10 exp 6. The Strouhal number based on airfoil projected height was nominally 0.02 and increased slightly with increasing Reynolds number and significantly with increasing airfoil angle of attack. Balow focused his research on the leading-edge separation bubble which was hypothesized to be the origin of the low-frequency oscillation. Initially, experimental measurements in the bubble at the onset of the low-frequency oscillation were attempted to study the characteristics of the bubble and explain possible relationships to the shear-layer-flapping phenomena. Unfortunately, the bubble proved to be extremely sensitive to the probe interference and it drastically reduced the size of the bubble. These detailed measurements were then abandoned by Balow. However, this led to a series of tests where the leading-edge bubble and trailing-edge separation were altered and the affect on the flow-oscillation studied. Balow found that by tripping the airfoil boundary-layer with "zigzag" tape ahead of bubble separation, the bubble was effectively eliminated mid the oscillation suppressed. Wake survey drag measurements showed a drastic reduction in airfoil drag when the bubble and oscillation were eliminated. Using the "zigzag" tape, the trailing-edge separation was moved downstream approximately 5 percent chord. This was found to reduce the amplitude of the oscillation, particularly in the onset stage at low angle of attack (around 14 degrees). Through detailed analysis of the wake behind the airfoil during the unsteady flow oscillation, Balow provided a better understanding of the wake flowfield. Broeren studied the oscillating flowfield in detail at Reynolds number equal 3 x 10 exp 5 and an angle of attack of 15 degrees using laser Doppler velocimetry (LDV). Two-dimensional LDV data were acquired at 687 grid points above the model upper surface while hot-wire data were taken simultaneously in the wake. Using the hot-wire signal, the LDV data were phase averaged into 24 bins to represent a single ensemble average of one oscillation cycle. The velocity data showed a flowfield oscillation that could be divided into three flow regimes. In the first regime, the flow over the airfoil was completely separated initially, the flowfield reattached from the leading edge and the reattachment point moved downstream with increasing time or phase. Broeren referred to this as the reattachment regime. The bubble development regime followed, where a leading-edge separation bubble formed at the leading edge and grew with increasing time. During the initial part of this regime the trailing-edge separation continued to move downstream. However, during the last 30 degrees of phase the trailing-edge separation moved rapidly forward and appeared to merge with the leading-edge bubble. During the third regime, the separation regime, the flow was segmented from the airfoil leading edge and did not reattach to the airfoil surface. The reverse flow was seen to grow in vertical extent up from the model surface as the phase increased. Next reattachment began again at the leading edge signaling the start of the reattachment regime, and so the cycle continued. From Broeren's work, the details of the unsteady flowfield over the airfoil were seen for the first time. From this research a great deal has been learned about the low-frequency flow oscillation which naturally occurs on the LRN-1007 airfoil near stall. The oscillation was seen to persist at higher Reynolds number, the dependence of the Strouhal number on angle of attack and Reynolds number were discovered, the critical role played by the laminar bubble was shown and the entire upper surface flowfield during a flow oscillation cycle was measured and analyzed. What still eludes understanding is the scaling of the flow oscillation and why certain airfoils, such as the LRN, have a very strong low-frequency mode and other airfoils exhibit no organized low-frequency oscillation at all.
Quasi-optical oscillators were proposed a little more than ten years ago as a means of developing the power levels needed for applications at millimeter frequencies using large numbers of individual semiconductor devices each of which produces only a modest amount of power [J.W. Mink, IEEE Trans. MTT., vol. 34, p. 273, 19861. An operating system was demonstrated soon after [Z.B. Popovic et. al, Int. J. Infrared and Millimeter Waves, v. 9, p. 647, 1988] in the form of a so-called grid oscillator. This device constituted a rectangular array of oscillating devices that are mutually coupled so that they oscillator coherently. The interconnecting lines in one direction serve as radiators so that the oscillators radiate directly, and the radiated fields add. Subsequently, coupled oscillators using resonant transmission line lengths was demonstrated by Mortazawi and Itoh [IEEE Trans. MTT., vol. 38, p. 86,1990). In recent work, coupled-oscillator power combiners have received less attention, with amplifier/combiners receiving more attention. Specific weaknesses of spatial-combining oscillators have motivated this transition. Namely, the oscillators employ low-Q resonators (resulting in low signal quality) and no clear means of modulation has been identified until recently. In this presentation, we review coupled-oscillator combiners in broad terms, indicating the features that make particular systems viable. We indicate how these features can be reconciled to functional requirements for system applications. Comparisons are drawn between two approaches to obtain mutual coupling: One employs low-Q oscillator circuits at each site, with concomitantly high propensity for the oscillators to couple. The other approach employs moderate-Q oscillators at each site with the concomitant requirement to tune the oscillators so that they share a range of frequencies over which they can couple and lock. In either case, precise frequency control and modulation can be achieved through locking to an external frequency source that ensures high quality signals. A recent development in coupled-oscillator arrays provides a means for beam-steering the radiation field of coupled oscillators through de-tuning of the edge elements in the array. This detuning introduces a progressive phase shift across the oscillator array. This 0 suggests architectures that can replace the functionality of a phased array without the cost 0 incurred by phase shifters. A comprehensive theory of the phase interactions among devices in such arrays is under development [e.g., Pogorzelski, York, and Maccarini, 1998 AP-S International Symposium, Atlanta, GA. June, 19981.
The oscillation behavior of laminar lifted flames under the influence of low-frequency AC has been investigated experimentally in coflow jets. Various oscillation modes were existed depending on jet velocity and the voltage and frequency of AC, especially when the AC frequency was typically smaller than 30 Hz. Three different oscillation modes were observed: (1) large-scale oscillation with the oscillation frequency of about 0.1 Hz, which was independent of the applied AC frequency, (2) small-scale oscillation synchronized to the applied AC frequency, and (3) doubly-periodic oscillation with small-scale oscillation embedded in large-scale oscillation. As the AC frequency decreased from 30 Hz, the oscillation modes were in the order of the large-scale oscillation, doubly-periodic oscillation, and small-scale oscillation. The onset of the oscillation for the AC frequency smaller than 30 Hz was in close agreement with the delay time scale for the ionic wind effect to occur, that is, the collision response time. Frequency-doubling behavior for the small-scale oscillation has also been observed. Possible mechanisms for the large-scale oscillation and the frequency-doubling behavior have been discussed, although the detailed understanding of the underlying mechanisms will be a future study. (author)
A differential SiGe oscillator circuit uses a resonant ring-oscillator topology in order to electronically tune the oscillator over multi-octave bandwidths. The oscillator s tuning is extremely linear, because the oscillator s frequency depends on the magnetic tuning of a YIG sphere, whose resonant frequency is equal to a fundamental constant times the DC magnetic field. This extremely simple circuit topology uses two coupling loops connecting a differential pair of SiGe bipolar transistors into a feedback configuration using a YIG tuned filter creating a closed-loop ring oscillator. SiGe device technology is used for this oscillator in order to keep the transistor s 1/f noise to an absolute minimum in order to achieve minimum RF phase noise. The single-end resonant ring oscillator currently has an advantage in fewer parts, but when the oscillation frequency is greater than 16 GHz, the package s parasitic behavior couples energy to the sphere and causes holes and poor phase noise performance. This is because the coupling to the YIG is extremely low, so that the oscillator operates at near the unloaded Q. With the differential resonant ring oscillator, the oscillation currents are just in the YIG coupling mechanisms. The phase noise is even better, and the physical size can be reduced to permit monolithic microwave integrated circuit oscillators. This invention is a YIG tuned oscillator circuit making use of a differential topology to simultaneously achieve an extremely broadband electronic tuning range and ultra-low phase noise. As a natural result of its differential circuit topology, all reactive elements, such as tuning stubs, which limit tuning bandwidth by contributing excessive open loop phase shift, have been eliminated. The differential oscillator s open-loop phase shift is associated with completely non-dispersive circuit elements such as the physical angle of the coupling loops, a differential loop crossover, and the high-frequency phase shift of the n-p-n transistors. At the input of the oscillator s feedback loop is a pair of differentially connected n-p-n SiGe transistors that provides extremely high gain, and because they are bulk-effect devices, extremely low 1/f noise (leading to ultralow RF phase noise). The 1/f corner frequency for n-p-n SiGe transistors is approximately 500 Hz. The RF energy from the transistor s collector output is connected directly to the top-coupling loop (the excitation loop) of a single-sphere YIG tuned filter. A uniform magnetic field to bias the YIG must be at a right angle to any vector associated with an RF current in a coupling loop in order for the precession to interact with the RF currents.
Highlights: • Spontaneous CBF oscillation was found in ciliated mouse nasal epithelial cells. • The CBF oscillation was caused by the [Ca{sup 2+}]i oscillation. • The [Ca{sup 2+}]i oscillations were generated by the periodic Ca{sup 2+} release from internal stores via interactions between IP{sub 3} and IP{sub 3} receptor. • The CBF oscillation may play a crucial role for maintaining an efficient mucociliary clearance in nasal epithelia. Ciliary beating frequency (CBF) was investigated in ciliated nasal epithelial cells (cMNECs) isolated from mice using video microscopy equipped with a high-speed camera. In cMNECs, a spontaneous CBF oscillation was observed. The CBF oscillation was abolished by BAPTA-AM but not by Ca{sup 2+}-free solution. The addition of thapsigargin, which depletes Ca{sup 2+} from internal stores, also abolished CBF oscillation. Moreover, the intracellular Ca{sup 2+} concentration [Ca{sup 2+}]{sub i}, spontaneously oscillated even with the Ca{sup 2+}-free solution. Moreover, 2APB (an inhibitor of the IP{sub 3} receptor) abolished CBF oscillation in cMNECs. Overall, these findings suggest that the CBF oscillation in cMNECs is triggered by the release of Ca{sup 2+} from the IP{sub 3}-sensitive internal stores. Moreover, IBMX, an inhibitor of phosphodiesterase, did not affect CBF oscillation in cMNECs, although it slightly increased CBF. These results suggest that CBF oscillations were induced by [Ca{sup 2+}]{sub i} oscillation controlled via the release of Ca{sup 2+} from IP{sub 3}-sensitive stores, rather than via cAMP accumulation. CBF oscillation possibly plays a crucial role in maintaining an efficient mucociliary clearance in the nasal epithelia.
This dissertation presents the analysis of the last two years of data from the MINOS+ long-baseline neutrino oscillation experiment. The analysis explores the data above the first oscillation maximum for neutrinos in the standard three-flavor neutrino oscillation model, adding significantly more neutrino events and constraining the model with increased precision. The analysis of the high-energy region of the MINOS+ data set, where previously there has been limited study, can help constrain alternative models or possibly show evidence of new phenomena. The predecessor to MINOS+, the MINOS experiment, measured $\nu_\mu$ disappearance and $\nu_{e}$ appearance using Fermilab's NuMI $\nu_\mu$ beam from 2005 to 2012. During this period the neutrino beam's energy spectrum was focused to peak near the first oscillation maximum. In addition to measuring accelerator beam neutrinos, the MINOS Far Detector collected a sample of atmospheric neutrinos from 2003 to 2011. With the se two samples, MINOS measured the atmospheric mass splitting, $\Delta{m}^2_{32}$, at the 5\% level and the value of $\sin^2\theta_{23}$ at the 15\% level. The data also constrained the CP violating parameter $\delta_{\rm CP}$. The MINOS+ experiment exposed the MINOS detectors to a neutrino beam peaked at energies above the oscillation maximum from 2013 to 2016. With this higher energy neutrino beam, MINOS+ measures the shape of the $\nu_\mu$ survival probability away from the oscillation maximum with unprecedented precision. Measuring the shape of the oscillation probability as a function of neutrino energy is an essential test of the three-flavor oscillation model. At these higher energies where the standard oscillation probability decreases, the neutrino energy spectrum is sensitive to potential perturbations from mixing with additional sterile neutrinos or non-standard neutrino interactions. This analysis of the complete data set from MINOS+ finds no significant deviatio ns from the three-flavor oscillation probability in the ener! gy region of 4 to 10\,GeV covered by the neutrino beam. This provides increased confidence in the three-flavor model in this region and provides new constraints of the atmospheric oscillation parameters, $\Delta{m}^2_{32}$ and $\sin^2\theta_{23}$, by combining the MINOS and MINOS+ data sets. The hierarchy of the neutrino masses is related to the sign of $\Delta{m}^2_{32}$. When $\Delta{m}^2_{32} > 0$, the mass hierarchy is classified as normal. When $\Delta{m}^2_{32} < 0$, the mass hierarchy is classified as inverted. This analysis cannot rule out either of the mass hierarchies. For the normal mass hierarchy, the combined analysis measures $\lvert{\Delta{m}^2_{32}}\rvert = 2.41\pm 0.09 \times 10^{-3}\,{\mathrm{eV}^2}$ at 68\% C.L. and $\sin^2\theta_{23} = 0.42_{-0.06}^{+0.23}$ at 90\% C.L. For the inverted mass hierarchy, this analysis measures $\lvert{\Delta{m}^2_{32}}\rvert = 2.47_{-0.10}^{+0.08} \times 10^{-3}\,{\mathrm{eV}^2}$ at 68\% C.L. and $\sin^2\theta_{23} = 0.42_{ -0.06}^{+0.23}$ at 90\% C.L. In addition to the analysis and measurement of the atmospheric oscillation parameters using MINOS+, this work updates the constraint on $\delta_{\rm CP}$ from MINOS and performs an exploratory combination using $\nu_\mu$ disappearance data from the NOvA experiment. The NOvA experiment uses the NuMI beam in an off-axis strategy that results in a narrow flux of muon neutrinos at the first oscillation maximum and allows precision measurements of the three-flavor parameters. Since NOvA and MINOS+ shared the same neutrino beam, their data can be combined taking advantage of common beam related uncertainties. Combined, the data from the MINOS, MINOS+, and NOvA experiments precisely map $\nu_\mu$ oscillation probabilities using the same neutrino beam in a way that could not be attempted before.
A few years ago York and colleagues suggested that injection locking of voltage controlled oscillators could be used to implement beam steering in a phased array [I]. The scheme makes use of the fact that when an oscillator is injection locked to an external signal, the phase difference between the output of the oscillator and the injection signal is governed by the difference between the injection frequency and the free running frequency of the oscillator (the frequency to which the oscillator is tuned). Thus, if voltage controlled oscillators (VCOs) are used, this phase difference is controlled by an applied voltage. Now, if a set of such oscillators are coupled to nearest neighbors, they can be made to mutually injection lock and oscillate as an ensemble. If they are all tuned to the same frequency, they will all oscillate in phase. Thus, if the outputs are connected to radiating elements forming a linear array, the antenna will radiate normal to the line of elements. Scanning is accomplished by antisymmetrically detuning the end oscillators in the array by application of a pair of appropriate voltages to their tuning ports. This results in a linear phase progression across the array which is just the phasing required to scan the beam. The scan angle is determined by the degree of detuning. We have constructed a seven element one dimensional agile beam array at S-band based on the above principle. Although, a few such arrays have been built in the past, this array possesses two unique features. First, the VCO MMICs have buffer amplifiers which isolate the output from the tuning circuit, and second, the oscillators are weakly coupled to each other at their resonant circuits rather than their outputs. This results in a convenient isolation between the oscillator array design and the radiating aperture design. An important parameter in the design is the so called coupling phase which determines the phase shift of the signals passing from one oscillator to its neighbors. Using this array, we have been able to verify the theoretical predictions concerning the effect of this phase on both the locking range and ensemble frequency of the array. However, the scan range achieved fell somewhat short of the theoretical value because of the amplitude variation of the oscillator outputs with tuning.
Small signal stability problems are one of the major threats to grid stability and reliability in California and the western U.S. power grid. An unstable oscillatory mode can cause large-amplitude oscillations and may result in system breakup and large-scale blackouts. There have been several incidents of system-wide oscillations. Of them, the most notable is the August 10, 1996 western system breakup produced as a result of undamped system-wide oscillations. There is a great need for real-time monitoring of small-signal oscillations in the system. In power systems, a small-signal oscillation is the result of poor electromechanical damping. Considerable understanding and literature have been developed on the small-signal stability problem over the past 50+ years. These studies have been mainly based on a linearized system model and eigenvalue analysis of its characteristic matrix. However, its practical feasibility is greatly limited as power system models have been found inadequate in describing real-time operating conditions. Significant efforts have been devoted to monitoring system oscillatory behaviors from real-time measurements in the past 20 years. The deployment of phasor measurement units (PMU) provides high-precision time-synchronized data needed for estimating oscillation modes. Measurement-based modal analysis, also known as ModeMeter, uses real-time phasor measure-ments to estimate system oscillation modes and their damping. Low damping indicates potential system stability issues. Oscillation alarms can be issued when the power system is lightly damped. A good oscillation alarm tool can provide time for operators to take remedial reaction and reduce the probability of a system breakup as a result of a light damping condition. Real-time oscillation monitoring requires ModeMeter algorithms to have the capability to work with various kinds of measurements: disturbance data (ringdown signals), noise probing data, and ambient data. Several measurement-based modal analysis algorithms have been developed. They include Prony analysis, Regularized Ro-bust Recursive Least Square (R3LS) algorithm, Yule-Walker algorithm, Yule-Walker Spectrum algorithm, and the N4SID algo-rithm. Each has been shown to be effective for certain situations, but not as effective for some other situations. For example, the traditional Prony analysis works well for disturbance data but not for ambient data, while Yule-Walker is designed for ambient data only. Even in an algorithm that works for both disturbance data and ambient data, such as R3LS, latency results from the time window used in the algorithm is an issue in timely estimation of oscillation modes. For ambient data, the time window needs to be longer to accumulate information for a reasonably accurate estimation; while for disturbance data, the time window can be significantly shorter so the latency in estimation can be much less. In addition, adding a known input signal such as noise probing signals can increase the knowledge of system oscillatory properties and thus improve the quality of mode estimation. System situations change over time. Disturbances can occur at any time, and probing signals can be added for a certain time period and then removed. All these observations point to the need to add intelligence to ModeMeter applications. That is, a ModeMeter needs to adaptively select different algorithms and adjust parameters for various situations. This project aims to develop systematic approaches for algorithm selection and parameter adjustment. The very first step is to detect occurrence of oscillations so the algorithm and parameters can be changed accordingly. The proposed oscillation detection approach is based on the signal-noise ratio of measurements.
The Solar Optical Telescope on board Hinode observed a sunspot (AR 11836) with two light bridges (LBs) on 2013 August 31. We analyzed a two-hour Ca II H emission intensity data set and detected strong five-minute oscillation power on both LBs and in the inner penumbra. The time-distance plot reveals that the five-minute oscillation phase does not vary significantly along the thin bridge, indicating that the oscillations are likely to originate from underneath it. The slit taken along the central axis of the wide LB exhibits a standing wave feature. However, at the center of the wide bridge, the five-minute oscillation power is found to be stronger than at its sides. Moreover, the time-distance plot across the wide bridge exhibits a herringbone pattern that indicates a counter-stream of two running waves, which originated at the bridge's sides. Thus, the five-minute oscillations on the wide bridge also resemble the properties of running penumbral waves. The five-minute oscillations are suppressed in the umbra, while the three-minute oscillations occupy all three cores of the sunspot's umbra, separated by the LBs. The three-minute oscillations were found to be in phase at both sides of the LBs. This may indicate that either LBs do not affect umbral oscillations, or that umbral oscillations at different umbral cores share the same source. It also indicates that LBs are rather shallow objects situated in the upper part of the umbra. We found that umbral flashes (UFs) follow the life cycles of umbral oscillations with much larger amplitudes. They cannot propagate across LBs. UFs dominate the three-minute oscillation power within each core; however, they do not disrupt the phase of umbral oscillation.