Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron generators.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

McStas Analysis of Monoenergetic Thermal Neutron Beam Generation for Total Cross Section Measurements

The thermal neutron scattering law (TSL) of a given material represents data that is essential for assessing the criticality safety of a neutronic system in which this material is utilized. Traditionally, the TSL is developed through elaborate calculations that combine input and models based on condensed matter physics and scattering theory. Nonetheless, measurements of key parameters (e.g., the total cross section at low energies) can help in benchmarking and validating TSL libraries such as those used in the ENDF/B database. In this work, the setup of experiments, at the PULSTAR reactor of North Carolina State University (NCSU), for creating monoenergetic thermal neutron beams in support of total scattering cross section measurements in the thermal energy range is explored using McStas simulations and experimental verification. A McStas model has been established of the NPD facility at the NCSU PULSTAR reactor to explore the production of monoenergetic thermal neutron beams in support of various applications including total cross section measurements. The McStas results clearly demonstrate the viability of six monochromatic thermal neutron beams with substantial intensities that allow future applications at the NPD facility. The experimental results reasonably support the computational model predictions. Based on these results, transmission thermal neutron experiments can be conducted for data validation studies. Furthermore, the model also allows the evaluation of design changes to expand the portfolio of available monoenergetic thermal neutron beams. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Container inspection in the port container terminal by using 14 MeV neutrons

A proposal for an autonomous and flexible ship container inspection system is presented. This could be accomplished by the incorporation of inspection system on the container transportation devices (straddle carriers, yard gentry cranes automated guided vehicles, trailers). This configuration is terminal specific and it will be decided by container terminal operator. In such a way no part of port operational area will be used for inspection. The inspection scenario will include container transfer from ship to transportation device with inspection unit mounted on it, inspection during container movement to the container location. A neutron generator without associated alpha particle detection will be used. This will allow the use of higher neutron intensity (5x10{sup 9} - 10{sup 10} n/s in 4π). The inspected container will be stationary in the 'inspection position' on the transportation device while the 'inspection unit' will move along its side. Following analytical methods will be used simultaneously: neutron radiography, X-ray radiography, neutron activation analysis, (n,γ) and (n,n'γ) reactions, neutron absorption, and scattering, X-ray backscattering, Neutron techniques will take the advantage of using 'smart collimators' for neutrons and gammas, both emitted and detected. The inspected voxel will be defined by intersections/union of neutron generator and detectors solid angles. The container inspection protocol will be based on identification of discrepancies between its cargo manifest and its elemental 'fingerprint' and radiography profiles. In addition, the information on container weight will be obtained during the container transport and foreseen screening from the measurement of density of material in the container. (authors)

42 ENGINEERING↗

Evaluation of LLNL's Nuclear Accident Dosimeters at the CALIBAN Reactor September 2010

The Lawrence Livermore National Laboratory uses neutron activation elements in a Panasonic TLD holder as a personnel nuclear accident dosimeter (PNAD). The LLNL PNAD has periodically been tested using a Cf-252 neutron source, however until 2009, it was more than 25 years since the PNAD has been tested against a source of neutrons that arise from a reactor generated neutron spectrum that simulates a criticality. In October 2009, LLNL participated in an intercomparison of nuclear accident dosimeters at the CEA Valduc Silene reactor (Hickman, et.al. 2010). In September 2010, LLNL participated in a second intercomparison of nuclear accident dosimeters at CEA Valduc. The reactor generated neutron irradiations for the 2010 exercise were performed at the Caliban reactor. The Caliban results are described in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of ZnO-Based Polycrystalline Ceramic Scintillators for Use as ?-Particle Detectors

ZnO-based scintillators are particularly well-suited for use as the associated particle detector in a deuterium-tritium (D-T) neutron generator. Application requirements include the exclusion of organic materials, outstanding timing resolution, and high radiation resistance. ZnO, ZnO:Ga, ZnO:In, ZnO:In,Li, and ZnO:Er,Li have demonstrated fast (sub-nanosecond) decay times with relatively low light yields. ZnO:Ga has been used in a powder form as the associated particle detector for a D-T neutron generator. Unfortunately, detectors using powders are difficult to assemble and the light yield from powders is less than satisfactory. Single crystal ZnO of sufficient size has only recently become available. New applications for D-T neutron generators require better timing resolution and higher count rates than are currently available with associated particle detectors using YAP:Ce as the scintillator. Recent work suggests that ZnO-based scintillators can provide alpha-particle-excited light yields comparable to YAP:Ce scintillators. ZnO-based polycrystalline ceramic scintillators offer the advantages of high light yield, ease of fabrication, low cost, and robust mechanical properties. Precursor powders used in these studies include ZnO and ZnO:Ga powders synthesized using solution phase, urea precipitation, and combustion synthesis techniques as well as ZnO powder from a commercial vendor. Precursor powders have been sintered using uniaxial hot pressing and spark plasma sintering techniques. Photoluminescence measurements have confirmed that, for most samples, the emissions from these sintered bodies consist primarily of slow, visible emissions rather than the desired, sub-nanosecond near-band-edge emissions. Subsequent hydrogen treatments have shown significant improvements in the luminescence characteristics of some ceramic bodies while other samples have shown no change in luminescence.

08 HYDROGEN↗

Fission signal detection using helium-4 gas fast neutron scintillation detectors

We demonstrate the unambiguous detection of the fission neutron signal produced in natural uranium during active neutron interrogation using a deuterium-deuterium fusion neutron generator and a high pressure {sup 4}He gas fast neutron scintillation detector. The energy deposition by individual neutrons is quantified, and energy discrimination is used to differentiate the induced fission neutrons from the mono-energetic interrogation neutrons. The detector can discriminate between different incident neutron energies using pulse height discrimination of the slow scintillation component of the elastic scattering interaction between a neutron and the {sup 4}He atom. Energy histograms resulting from this data show the buildup of a detected fission neutron signal at higher energies. The detector is shown here to detect a unique fission neutron signal from a natural uranium sample during active interrogation with a (d, d) neutron generator. This signal path has a direct application to the detection of shielded nuclear material in cargo and air containers. It allows for continuous interrogation and detection while greatly minimizing the potential for false alarms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Diffraction Studies of Intercritically Austempered Ductile Irons

Neutron diffraction is a powerful tool that can be used to identify the phases present and to measure the spacing of the atomic planes in a material. Thus, the residual stresses can be determined within a component and/or the phases present. New intercritically austempered irons rely on the unique properties of the austenite phase present in their microstructures. If these materials are to see widespread use, methods to verify the quality (behavior consistency) of these materials and to provide guidance for further optimization will be needed. Neutron diffraction studies were performed at the second generation neutron residual stress facility (NRSF2) at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory on a variety of intercritically austempered irons. For similar materials, such as TRIP steels, the strengthening mechanism involves the transformation of metastable austenite to martensite during deformation. For the intercritically austempered ductile irons two different deformation/strengthening mechanisms, phase transformation and slip, dependent upon the iron chemistry, were observed. Lattice strain and phase fraction data as a function of applied stress are presented.

Druschitz, Alan↗

Development of pulsed neutron uranium logging instrument

This article introduces a development of pulsed neutron uranium logging instrument. By analyzing the temporal distribution of epithermal neutrons generated from the thermal fission of {sup 235}U, we propose a new method with a uranium-bearing index to calculate the uranium content in the formation. An instrument employing a D-T neutron generator and two epithermal neutron detectors has been developed. The logging response is studied using Monte Carlo simulation and experiments in calibration wells. The simulation and experimental results show that the uranium-bearing index is linearly correlated with the uranium content, and the porosity and thermal neutron lifetime of the formation can be acquired simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid response sensor for analyzing Special Nuclear Material

Rapid in-situ analytical techniques are attractive for characterizing Special Nuclear Material (SNM). Present techniques are time consuming, and require sample dissolution. Proof-of-principal studies are performed to demonstrate the utility of employing low energy neutrons from a portable pulsed neutron generator for non-destructive isotopic analysis of nuclear material. In particular, time-sequenced data acquisition, operating synchronously with the pulsing of a neutron generator, partitions the characteristic elemental prompt gamma-rays according to the type of the reaction; inelastic neutron scattering reactions during the ON state and thermal neutron capture reactions during the OFF state of the generator. Thus, the key challenge is isolating these signature gamma- rays from the prompt fission and β-delayed gamma-rays that are also produced during the neutron interrogation. A commercial digital multi-channel analyzer has been specially customized to enable time-resolved gamma-ray spectral data to be acquired in multiple user-defined time bins within each of the ON/OFF gate periods of the neutron generator. Preliminary results on new signatures from depleted uranium as well as modeling and benchmarking of the concept are presented, however this approach should should be applicable for virtually all forms of SNM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of an Energy Tuning Assembly for High Explosives Detection

The Portable Isotopic Neutron Spectroscopy (PINS) system, employs neutron-induced gamma-ray spectroscopy and provides a nondestructive method for high explosives detection. In standard operation it uses Californium-252 as a neutron source. Operating PINS with a deuterium-tritium (DT) neutron generator has some advantages over Cf-252, including lifetime and ability to produce high-energy inelastic scattering gamma rays. However, current systems using DT neutron generators suffer from a high environmental background and reduced ability to induce neutron capture, reducing spectral quality and limiting nitrogen sensitivity. Here, this study presents the development of an energy-tuning assembly (ETA) designed to optimize the DT neutron energy spectrum to increase nitrogen reaction rates in a target, thereby improving high explosive detection capabilities. A metaheuristic optimization framework, MultiGNOWEE, coupled with MCNP, was employed to generate two ETA configurations: a single-objective ETA, which maximizes nitrogen capture reactions, and a multi-objective ETA, which balances neutron capture and inelastic scattering. Simulations demonstrated the optimized configurations achieved up to a 10-fold improvement in nitrogen capture rates compared to the bare configuration. Experimental validation was conducted using a DT neutron generator and a high-purity germanium (HPGe) detector. Two prototype ETAs were constructed and assessed on a melamine simulant. Measurements demonstrated improved nitrogen detection for both prototype ETA configurations when compared to the standard system.

97 MATHEMATICS AND COMPUTING↗

A Comparison of Neutron-Based Non-Destructive Assessment Methods for Chemical Warfare Materiel and High Explosives

Prompt Gamma Neutron Activation Analysis (PGNAA) systems employ neutrons as a probe to interrogate items, e.g. chemical warfare materiel-filled munitions. The choice of a neutron source in field-portable systems is determined by its ability to excite nuclei of interest, operational concerns such as radiological safety and ease-of-use, and cost. Idaho National Laboratory’s PINS Chemical Assay System has traditionally used a Cf-252 isotopic neutron source, but recently a Deuterium-Tritium (DT) Electronic Neutron Generator (ENG) has been tested as an alternate neutron source. This paper presents the results of using both of these neutron sources to interrogate chemical warfare materiel (CWM) and high explosive (HE) filled munitions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Monte Carlo Simulations of the Response of Shielded SNM to a Pulsed Neutron Source

Active interrogation (AI) has been used as a technique for the detection and identification of Special Nuclear Material (SNM) for both proposed and field-tested systems. Idaho National Laboratory (INL) has been studying this technique for systems ranging from small systems employing portable electronic neutron generators (ENGs) 1 to larger systems employing linear accelerators as high-energy photon sources for assessment of vehicles and cargo2. In order to assess the feasibility of new systems, INL has undertaken a campaign of Monte Carlo simulations of the response of a variety of masses of SNM in multiple shielding configurations to a pulsed neutron source using the MCNPX3 code, with emphasis on the neutron and photon response of the system as a function of time after the initial neutron pulse. We present here some preliminary results from these calculations. 1. D.L. Chichester and E.H. Seabury, “ Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Nuclear Material,” IEEE Transactions on Nuclear Science 56 (2009) pp 441-447. 2. J.L. Jones et al., “Photonuclear-based, nuclear material detection system for cargo containers,” Nuclear Instruments and Methods in Physics Research B 241 (2005) pp 770-776. 3. D.B. Pelowitz, “MCNPXTM User’s Manual version 2.6.0,” Los Alamos National Laboratory Report LA-CP-07-1473 (2008).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of SEM and Optical Analysis of DT Neutron Tracks in CR-39 Detectors

CR-39 detectors were exposed to DT neutrons generated by a Thermo Fisher model A290 neutron generator. Afterwards, the etched tracks were examined both optically and by SEM. The purpose of the analysis was to compare the two techniques and to determine whether additional information on track geometry could be obtained by SEM analysis. The use of these techniques to examine triple tracks, diagnostic of ≥9.6 MeV neutrons, observed in CR-39 used in Pd/D codeposition experiments will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of 14 MeV neutrons in high temperature environment up to 500 deg. C using 4H-SiC based diode detector

In reactor technology and industrial applications detection of fast and thermal neutrons plays a crucial role in getting relevant information about the reactor environment and neutron yield. The inevitable elevated temperatures make neutron yield measurements problematic. Out of the currently available semiconductors 4H-SiC seems to be the most suitable neutron detector material under extreme conditions due to its high heat and radiation resistance, large band-gap and lower cost of production than in case of competing diamond detectors. In the framework of the European I-Smart project, optimal {sup 4}H-SiC diode geometries were developed for high temperature neutron detection and have been tested with 14 MeV fast neutrons supplied by a deuterium-tritium neutron generator with an average neutron flux of 10{sup 10}-10{sup 11} n/(s*cm{sup 2}) at Neutron Laboratory of the Technical University of Dresden in Germany from room temperatures up to several hundred degrees Celsius. Based on the results of the diode measurements, detector geometries appear to play a crucial role for high temperature measurements up to 500 deg. C. Experimental set-ups using SiC detectors were constructed to simulate operation in the harsh environmental conditions found in the tritium breeding blanket of the ITER fusion reactor, which is planned to be the location of neutron flux characterization measurements in the near future. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synergistic effects of Al, Ga, and In doping on ZnO nanorod arrays grown via citrate-assisted hydrothermal technique for highly efficient and fast scintillator screens

To be used as efficient alpha particle scintillator in the fields of nuclear security, nuclear nonproliferation and high-energy physics, scintillator screens must have high light output and fast decay properties. While there has been a great deal of progress in scintillation efficiency, achieving fast decay time properties are still a challenge. In this work, the near band edge (NBE) UV luminescence and alpha particle induced scintillation properties of vertically aligned densely packed ZnO nanorods (NRs) doped with Al, Ga, and In have been thoroughly investigated. The high crystalline hexagonal wurtzite structure with a strong orientation through the c -axis plane (002) and aspect ratios in the range 13–22 have been observed for all ZnO NRs. Electron paramagnetic resonance (EPR) analysis exhibited paramagnetic signals at g ≈ 1.96 for all ZnO NRs. A cost effective green hydrothermal synthesis technique was employed to grow well-aligned NRs. Using citrate as an additive acting as a strong reducing agent in the solution during the crystal growth, defects on the surface are significantly suppressed, thereby enhancing the NBE UV emission. Significantly higher NBE UV emission was observed from the top surface of ZnO NRs in cathodoluminescence (CL) microscopy. Results show that citrate assisted donor doping of ZnO NRs not only reduces the defect emission and NBE self-absorption, but also induces fast decay time (~ 600–700 ps), which makes ZnO NRs a good candidate for fast alpha particle scintillator screens used in associated particle imaging for time and direction tagging of individual neutrons generated in D–T and D–D neutron generators.

36 MATERIALS SCIENCE↗

Performance Study of an aSi Flat Panel Detector for Fast Neutron Imaging of Nuclear Waste

Radioactive waste must be characterized to check its conformance for intermediate storage and final disposal according to national regulations. For the determination of radio-toxic and chemo-toxic contents of radioactive waste packages non-destructive analytical techniques are preferentially used. Fast neutron imaging is a promising technique to assay large and dense items providing, in complementarity to photon imaging, additional information on the presence of structures in radioactive waste packages. Therefore the feasibility of a compact Neutron Imaging System for Radioactive waste Analysis (NISRA) using 14 MeV neutrons is studied in a cooperation framework of Forschungszentrum Juelich GmbH, RWTH Aachen University and Siemens AG. However due to the low neutron emission of neutron generators in comparison to research reactors the challenging task resides in the development of an imaging detector with a high efficiency, a low sensitivity to gamma radiation and a resolution sufficient for the purpose. The setup is composed of a commercial D-T neutron generator (Genie16GT, Sodern) with a surrounding shielding made of polyethylene, which acts as a collimator and an amorphous silicon flat panel detector (aSi, 40 x 40 cm{sup 2}, XRD-1642, Perkin Elmer). Neutron detection is achieved using a general propose plastic scintillator (EJ-260, Eljen Technology) linked to the detector. The thermal noise of the photodiodes is reduced by employing an entrance window made of aluminium. Optimal gain and integration time for data acquisition are set by measuring the response of the detector to the radiation of a 500 MBq {sup 241}Am-source. Detector performance was studied by recording neutron radiography images of materials with various, but well known, chemical compositions, densities and dimensions (Al, C, Fe, Pb, W, concrete, polyethylene, 5 x 8 x 10 cm{sup 3}). To simulate gamma-ray emitting waste radiographs in presence of a gamma-ray sources ({sup 60}Co, {sup 137}Cs, {sup 241}Am) were performed. A homemade algorithm was developed to determine a value which is related to the neutron absorption of the sample with the analysis of the raw detector data. The detector was placed 42 cm away from the neutron source. Distance between detector and the samples was 0.5 cm. At the sample position the fast neutron flux was estimated to 9x10{sup 3} n cm{sup -2} s{sup -1} for a neutron emission of 10{sup 8} n s{sup -1}. The acquisition time was 15 minutes. First neutron radiographs were successfully recorded despite the low detector efficiency and low neutron emission. Analysis of the data shows a correlation between the measured signal and determined neutron absorption. Thus discrimination between different materials of same thicknesses may be achieved. The measurements and results will be presented and discussed in details.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Irradiation of electronic components and circuits at the Portuguese Research Reactor: Lessons learned

The behavior of electronic components and circuits under radiation is a concern shared by the nuclear industry, the space community and the high-energy physics community. Standard commercial components are used as much as possible instead of radiation hard components, since they are easier to obtain and allow a significant reduction of costs. However, these standard components need to be tested in order to determine their radiation tolerance. The Portuguese Research Reactor (RPI) is a 1 MW pool-type reactor, operating since 1961. The irradiation of electronic components and circuits is one area where a 1 MW reactor can be competitive, since the fast neutron fluences required for testing are in most cases well below 10{sup 16} n/cm{sup 2}. A program was started in 1999 to test electronics components and circuits for the LHC facility at CERN, initially using a dedicated in-pool irradiation device and later a beam line with tailored neutron and gamma filters. Neutron filters are essential to reduce the intensity of the thermal neutron flux, which does not produce significant defects in electronic components but produces unwanted radiation from activation of contacts and packages of integrated circuits and also of the printed circuit boards. In irradiations performed within the line-of-sight of the core of a fission reactor there is simultaneous gamma radiation which complicates testing in some cases. Filters can be used to reduce its importance and separate testing with a pure gamma radiation source can contribute to clarify some irradiation results. Practice has shown the need to introduce several improvements to the procedures and facilities over the years. We will review improvements done in the following areas: - Optimization of neutron and gamma filters; - Dosimetry procedures in mixed neutron / gamma fields; - Determination of hardness parameter and 1 MeV-equivalent neutron fluence; - Temperature measurement and control during irradiation; - Follow-up of reactor power operational fluctuations; - Study of gamma radiation effects only. The fission neutron spectrum can be limitative for some of the tests, as most neutrons are in the 1-2 MeV energy range. Significant progress has been made lately in compact neutron generators using D-D and D-T fusion reactions, achieving higher neutron fluxes and longer lifetime than previously available. The advantages of using compact neutron generators for testing of electronic components and circuits will be also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Neutron Die-Way-Time Studies for P and DGNAA of Radioactive Waste Drums at the MEDINA Facility

In Germany, radioactive waste with negligible heat production has to pass through a process of quality checking in order to check its conformance with national regulations prior to its transport, intermediate storage and final disposal. Additionally to its radioactive components, the waste may contain non-radioactive chemically toxic substances that can adversely affect human health and pollute the environment, especially the ground water. After an adequate decay time, the waste radioactivity will become harmless but the non-radioactive substances will persist over time. In principle, these hazardous substances may be quantified from traceability and quality controls performed during the production of the waste packages. As a consequence, a research and development program was initiated in 2007 with the aim to develop a nondestructive analytical technique for radioactive waste packages based on prompt and delayed gamma neutron activation analysis (P and DGNAA) employing a DT-neutron generator in pulsed mode. In a preliminary study it was experimentally demonstrated that P and DGNAA is suitable to determine the chemical composition of large samples. In 2010 a facility called MEDINA (Multi Element Detection based on Instrumental Neutron Activation) was developed for the qualitative and quantitative determination of nonradioactive, toxic elements and substances in 200-l steel drums. The determination of hazardous substances and elements is generally achieved measuring the prompt gamma-rays induced by thermal neutrons. Additional information about the composition of the waste matrix could be derived measuring the delayed gamma-rays from short life activation products. However a sensitive detection of these delayed gamma-rays requires that thermal neutrons have almost vanished. Therefore, the thermal neutron die-away-time has to be known in order to achieve an optimal discrimination between prompt and delayed gamma-ray spectra acquisition. Measurements Thermal neutron die-away times have been determined for the following cases: a) the empty chamber, b ) an empty 200-l steel drum, for a 200-l steel drum filled c) with concrete d) with polyethylene and e) with a mixture of polyethylene and concrete by measuring the prompt-gamma ray count rate of relevant isotopes like of {sup 1}H, {sup 10}B, {sup 12}C, {sup 28}Si, {sup 35}Cl, {sup 40}Ca and {sup 56}Fe which are emitted from different parts of the facility and the sample. Additionally, the average die-away-time was determined from the total detector count rate. The neutron generator was operated with a neutron emission of 8x10{sup 7} n.s{sup -1}, a neutron pulse with a length of 250 μs and a repetition time of 5 ms. The spectra were acquired between the neutron pulses over t{sub c}=500 μs after a pre-defined waiting time t{sub D} (multiple of 500 μs). The thermal neutron die-away time was ranging between 0.9 ms and 5 ms according to the sample composition. As an example the measured thermal neutron die-away-time Λ [μs] of a drum filled with concrete is presented. Detailed results of this study will be presented and discussed. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗