Measurement of EJ-228 plastic scintillator proton light output using a coincident neutron scatter technique
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The proton light yield of organic scintillators has been measured extensively in recent years using fast waveform digitizers and large discrepancies exist in the values reported by different authors. In this letter, we address principles of digital signal processing that must be considered when conducting scintillator light yield measurements. Digitized waveform pulse height values are only proportional to the amount of scintillation light if the temporal shape of the scintillation pulse is independent of the amount of energy deposited. Finally, this is not the case for scintillation pulses resulting from fast neutron interactions in organic scintillators. Authors measuring proton light yield should therefore report pulse integral values and ensure that the integration length is long enough to capture most of the scintillation light.
The response of LaBr 3 (Ce) and LaCl 3 (Ce) scintillators to fast neutrons is investigated. Neutron-induced charged-particle reactions are observed in both materials when exposed to the fast neutrons produced by an AmBe source, with pulse-shape discrimination used to separate channels. LaBr 3 (Ce) is found to have the best separation between reaction channels, while LaCl 3 (Ce) has a significantly higher efficiency.
In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.
A feasibility of preparing bulk photopolymerized plastics scintillators that contain vinyltoluene with multifunctional monomers, pentaerythritol tetraacrylate is shown. This formulation offers a simple and fast way to prepare polyvinyltoluene-based plastics with efficient fast neutron/gamma pulse shape discrimination (PSD) within minutes. 30 wt% of 2,5-diphenyloxazole (PPO) was added in the mixtures of vinyltoluene and pentaerythritol tetraacrylate with different secondary dyes to understand the effect of dyes on the scintillation. Prepared resins were photopolymerized under different conditions, and the scintillation performance was compared to a commercially available standard, EJ-276. Additional functionality for thermal neutron sensitivity was introduced by the incorporation of 6 Li and 6 B nuclei. With optimized conditions, prepared plastics showed light output up to 90% relative to the same size of EJ-276. Here, the best plastic scintillators had PSD figures of merit (FoMs) up to 2.77 compared to 3.25 of EJ-276. The 3D-printability of the tested formulations was demonstrated.
Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.
Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.
The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.
Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.
nertial confinement fusion (ICF) experiments at the National Ignition Facility (NIF) suffer from asymmetries in thex-ray drive that degrade capsule performance compared to expectations for a symmetric one-dimensional implosion.Mode 1, or pole-to-pole, drive asymmetry can reduce confinement and implosion efficiency, driving a bulk motion ofthe hot spot that is detectable with neutron diagnostics. Understanding and removing sources of mode 1 asymmetry inICF implosions is important for improving performance, and the three-dimensional nature of the problem makes high-resolution radiation-hydrodynamic modeling extremely computationally expensive. This work describes a reducedorder view factor model that calculates the drive asymmetry induced by beam-to-beam variations in laser delivery andhohlraum diagnostic windows along the equator. Capsule response is estimated by coupling to a Green’s function thatrelates final hot spot velocity to the applied time-varying mode 1 asymmetry. The model makes several predictionsabout the impact of mode 1 drivers such as laser delivery and target misalignment, and achieves good agreementin both magnitude and vector direction for several shots in three families of high-performance platforms. However,notable discrepancies suggest other potential sources of mode 1 asymmetry not captured by the model are also at play
Background: We present that K 40 plays a significant role in the radiogenic heating of Earth-like exoplanets, which can affect the development of a habitable environment on their surfaces. The initial amount of K 40 in the interior of these planets depends on the composition of the interstellar clouds from which they formed. Within this context, nuclear reactions that regulate the production of K 40 during stellar evolution can play a critical role. Purpose: In this study, we constrain for the first time the astrophysical reaction rate of K 40 ( n , p ) Ar 40 , which is responsible for the destruction of K 40 during stellar nucleosynthesis. We provide to the nuclear physics community high-resolution data on the cross section and angular distribution of the Ar 40 ( p , n ) K 40 reaction. These are important to various applications involving Ar 40 . The associated reaction rate of the Ar 40 ( p , n ) K 40 process addresses a reaction rate gap in the Joint Institute for Nuclear Astrophysics REACLIB database in the region of intermediate-mass isotopes. Methods: We performed differential cross-section measurements on the Ar 40 ( p , n ) K 40 reaction, for six energies in the center-of-mass system between 3.2 and 4.0 MeV and various angles between 0 ° and 135 ° . The experiment took place at the Edwards Accelerator Laboratory at Ohio University using the beam swinger target location and a standard neutron time-of-flight technique. We extracted total and partial cross sections by integrating the double differential cross sections we measured. Results: The total and partial cross sections varied with energy due to the contribution from isobaric analog states and Ericson type fluctuations. The energy-averaged neutron angular distributions were symmetrical relative to 90 ° . Based on the experimental data, local transmission coefficients were extracted and were used to calculate the astrophysical reaction rates of Ar 40 ( p , n ) K 40 and K 40 ( n , p ) Ar 40 reactions. The new rates were found to vary significantly from the theoretical rates in the REACLIB library. We implemented the new rates in network calculations to study nucleosynthesis via the slow neutron capture process, and we found that the produced abundance of K 40 is reduced by up to 10% compared to calculations with the library rates. At the same time, the above result removes a significant portion of the previous theoretical uncertainty on the K 40 yields from stellar evolution calculations. Conclusions: Our results support a destruction rate of K 40 in massive stars via the K 40 ( n , p ) Ar 40 reaction that is larger compared to previous estimates. The rate of K 40 destruction via the K 40 ( n , p ) Ar 40 reaction now has a dramatically reduced uncertainty based on our measurement. Lastly, this result directly affects the predicted stellar yields of K 40 from nucleosynthesis, which is a critical input parameter for the galactic chemical evolution models that are currently employed for the study of significant properties of exoplanets.
The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024
Radioactivity induced by cosmic muon spallation is a dominant source of backgrounds for 𝒪(10 MeV) neutrino interactions in water Cherenkov detectors. In particular, it is crucial to reduce backgrounds to measure the solar neutrino spectrum and find neutrino interactions from distant supernovae. In this paper we introduce new techniques to locate muon-induced hadronic showers and efficiently reject spallation backgrounds. Applying these techniques to the solar neutrino analysis with an exposure of 2790 × 22.5 kton · day increases the signal efficiency by 12.6%, approximately corresponding to an additional year of detector running. Furthermore, we present the first spallation simulation at Super-Kamiokande, where we model hadronic interactions using fluka. The agreement between the isotope yields and shower pattern in this simulation and in the data gives confidence in the accuracy of this simulation, and thus opens the door to use it to optimize muon spallation removal in new data with gadolinium-enhanced neutron capture detection.
The first complete measurement of the $β$-decay strength distribution of $_{17}^{45}$Cl 28 was performed at the Facility for Rare Isotope Beams (FRIB) with the FRIB Decay Station Initiator during the second FRIB experiment. The measurement involved the detection of neutrons and $γ$ rays in two focal planes of the FRIB Decay Station Initiator in a single experiment for the first time. This enabled an analytical consistency in extracting the $β$-decay strength distribution over the large range of excitation energies, including neutron unbound states. Here, we observe a rapid increase in the $β$-decay strength distribution above the neutron separation energy in $_{18}^{45}$Ar 27 . This was interpreted to be caused by the transitioning of neutrons into protons excited across the Z = 20 shell gap. The SDPF-MU interaction with reduced shell gap best reproduced the data. The measurement demonstrates a new approach that is sensitive to the proton shell gap in neutron rich nuclei according to SDPF-MU calculations.
To estimate reactivity changes as a function of time from the signal of detectors count rates, one usually uses point kinetic equations. However, when detectors are located inside the core, it is often necessary to compute a correction factor to account for the flux-shape deformation (i.e. the change of detector efficiency that may have been induced by neutron absorbers movements). Various simulation methods have been developed depending on transients observed. They range from the resolution of static equations up to full-time-dependent neutron transport in 3D. However, those methods require high computational-cost calculations of local reaction rates that rely on nuclear data evaluations. Therefore, a 'measured' reactivity is never determined through pure measurements. Taking advantage of the known oscillation movement of a small sample at the center of the MINERVE reactor, the innovative algorithm presented in this paper derives the correction factor needed to get no time drift on reactivity steps. Derived correction factors are in good agreement with those obtained independently with TRIPOLI-4 through sensitivity analysis. Low sensitivity to the sample composition and moderate sensitivity to the detectors position reinforce the reliability of those results. This application paves the way to almost pure nuclear data reactivity measurements. (authors)
When UF 6 is located on the bottom of a cylindrical container lying flat, the Hage-Cifarelli formalism can be used to reconstruct the multiplication of the UF 6 and the strength of the 234 U (a,n) source, from which the 235 U can be inferred. However, when the UF 6 sticks to the ends or to the sides of the container, the reconstruction is no longer predictive in terms of source strength. The same conclusions were reached, whether one uses 3 He tubes or scintillators to detect the neutrons. Feynman’s point theory underlying the reconstruction would need to be improved to address the differences in source strenghts observed.
Element6 has come out of a two year production pause (pre-COVID) with material that lacks their previous QC – some is excellent, but screening is needed. Applied Diamond can now make usable polycrystalline material, for applications not requiring absolute flux calibration. A large area possible (1cm 2 ). Great Lakes Crystal Technology has made great progress in two years, but still needs development to become a trusted supplier of single crystal material. LANL staff (Dongsung Kim) has developed proficient lithography and bonding expertise at CINT to make devices from vendor supplied material. LANL staff has continued and expanded capabilities for device testing at NSLS-II.