Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Network monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Time Analyzer for Time Synchronization and Monitor of the Deep Space Network

A software package has been developed to measure, monitor, and archive the performance of timing signals distributed in the NASA Deep Space Network. Timing signals are generated from a central master clock and distributed to over 100 users at distances up to 30 kilometers. The time offset due to internal distribution delays and time jitter with respect to the central master clock are critical for successful spacecraft navigation, radio science, and very long baseline interferometry (VLBI) applications. The instrument controller and operator interface software is written in LabView and runs on the Linux operating system. The software controls a commercial multiplexer to switch 120 separate timing signals to measure offset and jitter with a time-interval counter referenced to the master clock. The offset of each channel is displayed in histogram form, and "out of specification" alarms are sent to a central complex monitor and control system. At any time, the measurement cycle of 120 signals can be interrupted for diagnostic tests on an individual channel. The instrument also routinely monitors and archives the long-term stability of all frequency standards or any other 1-pps source compared against the master clock. All data is stored and made available for

Cole, Steven↗

Ambient Aerosol Is Physically Larger on Cloudy Days in Bondville, Illinois

Particle chemical composition affects aerosol optical and physical properties in ways important for the fate, transport, and impact of atmospheric particulate matter. For example, hygroscopic constituents take up water to increase the physical size of a particle, which can alter the extinction properties and atmospheric lifetime. At the collocated AERosol RObotic NETwork (AERONET) and Interagency Monitoring of PROtected Visual Environments (IMPROVE) network monitoring stations in rural Bondville, Illinois, we employ a novel cloudiness determination method to compare measured aerosol physicochemical properties on predominantly cloudy and clear sky days from 2010 to 2019. On cloudy days, aerosol optical depth (AOD) is significantly higher than on clear sky days in all seasons. Measured angstrom ngstro''m exponents are significantly smaller on cloudy days, indicating physically larger average particle size for the sampled populations in all seasons except winter. Mass concentrations of fine particulate matter that include estimates of aerosol liquid water (ALW) are higher on cloudy days in all seasons but winter. More ALW on cloudy days is consistent with larger particle sizes inferred from angstrom ngstro''m exponent measurements. Aerosol chemical composition that affects hygroscopicity plays a determining impact on cloudy versus clear sky differences in AOD, angstrom ngstro''m exponents, and ALW. This work highlights the need for simultaneous collocated, high-time-resolution measurements of both aerosol chemical and physical properties, in particular at cloudy times when quantitative understanding of tropospheric composition is most uncertain.

54 ENVIRONMENTAL SCIENCES↗

Wilson Corners Solid Waste Management Unit (SWMU) 001: 2021 Annual Long-Term Monitoring Report, Kennedy Space Center, Florida

This report presents a summary of the long-term monitoring (LTM) activities that occurred in 2021 at Wilson Corners, Solid Waste Management Unit (SWMU) 001, at Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action Program. Adaptive site management is being utilized through ongoing assessment, design, and interim measures (IM). Annual LTM of the groundwater is also being conducted at the site. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code (F.A.C.). The goal of LTM at this site is threefold: to determine groundwater flow characteristics, monitor the downgradient concentration trends, and monitor select locations internal to the groundwater plume. Every 5 years, upgradient and side-gradient monitoring wells are sampled to verify delineation. The last time this was performed was in 2015. The sampling of these wells in 2020 was replaced with the direct push technology (DPT) investigations completed in October 2020 and April 2021. This DPT groundwater data was presented in an Advance Data Package (ADP) in September 2021 and discussed in the Implementation Work Plan (IWP) dated November 2021 for installation of an air sparge (AS) system. Based on results from groundwater sampling activities performed during the previous reporting period, including the 2020 and 2021 DPT groundwater sampling, it was determined that the LTM sampling plan was no longer meeting the goal of LTM because delineation was not verified. The 2021 LTM sampling plan was modified to include the sampling of monitoring wells located around the perimeter of the low concentration plume (LCP); the area with concentrations of contaminants of concern [COCs] greater than Groundwater Cleanup Target Levels [GCTLs]), and sampling of 10 monitoring wells proposed for installation (April 2021 KSC Remediation Team (KSCRT) Meeting, Decision 2104-D32). The modified LTM plan received team consensus at the September 2021 KSCRT Meeting (Decision Number 2109-D03), and sampling of the existing monitoring wells was completed in December 2021. The proposed monitoring wells are planned for installation in late 2022, concurrent with ongoing IM construction activities. December 2021 LTM data was presented at the May 2022 KSCRT Meeting, and activities are summarized in this report. The activities presented in this report include the December 2021 groundwater gauging of 42 monitoring wells and sampling of 44 monitoring wells. During the December 2021 event, the low flow sampling method was used, and samples were analyzed for a select list of volatile organic compounds (VOCs), including 1,1,2-trichloro-1,2,2-trifluoroethane (Freon 113). The following conclusions can be made based on the 2021 LTM results: - In December 2021, groundwater flow for the site was generally to the west at all intervals. This is generally consistent with historical observations at the site, with the exception of a southwest and southeast flow component observed at 34 to 48 feet below land surface (bls). - The vertical extent of VOCs was historically delineated by monitoring wells screened greater than 48 feet bls. The results from the two vertical extent monitoring wells, WILC-MW0078 (screened 65 to 70 feet bls) and WILC-MW0130 (screened 56 to 66 feet bls) that were sampled during the 2021 LTM indicate that groundwater vinyl chloride (VC) concentrations in both wells were greater than the GCTL. The Remediation Team has previously agreed to delay deeper DPT investigations in this area to prevent the creation of additional pathways for vertical migration. - The LCP continues to extend both horizontally, predominantly to the west, and vertically beyond the current monitoring well network, with some retraction observed to the southeast. Evaluation of this data combined with data from the 2020 and 2021 DPT sampling event indicate that the LCP encompasses an estimated 20.7 acres based on an expanded sampling area, as compared to the 2020 LCP footprint of 17.0 acres. - Freon 113 was not detected above GCTLs during the 2021 LTM event. Based on groundwater sampling activities performed in 2021, including April 2021 DPT groundwater sampling, the following recommendations are provided: - Perform the next LTM sampling event, targeted to occur in 2023, concurrently with the IM baseline sampling prior to AS system installation; - Include sampling from nine monitoring wells that are planned to be installed in late 2022, concurrent with upcoming IM construction activities. Installation of one deep vertical well, screened 70 to 80 feet bls, will be delayed to prevent the creation of an additional pathway for vertical migration; - Continue to sample under the modified annual LTM plan as presented in Table 4-1 concurrently with IM baseline sampling; and - Once the AS system install and start-up is complete, select monitoring wells from the LTM program will transition into the performance monitoring plan, and LTM will be temporarily discontinued. Performance monitoring will be performed quarterly, and the monitoring well network will be evaluated following the first performance monitoring sampling event.

long-term monitoring (LTM)↗

Brillouin Sensing with PCA, and PCA-Based Neural Networks for Efficient Temperature Monitoring

This work explores peak estimation techniques in Brillouin Optical Time Domain Analysis (BOTDA), emphasizing both accuracy and efficiency. Euclidean distance measurement method is applied to principal components derived from Brillouin Gain Spectrum data. It offers a major speed advantage being 180 170 times faster than traditional curve fitting methods such as Lorentzian curve fitting, while maintaining similar accuracy. Additionally, a PCA- based neural network model shows significant reduction of peak estimation time compared to Lorentzian fitting. Results show Brillouin frequency shift errors lie under 0.75 MHz in both Euclidean distance-based and neural network-based methods, both of which utilize PCA components. For large data sets and long length fibers, PCA- assisted neural network for peak estimation would be an efficient solution.

Distributed optical fiber sensing↗

Network resiliency through memory health monitoring and proactive management

A method for managing a network queue memory includes receiving sensor information about the network queue memory, predicting a memory failure in the network queue memory based on the sensor information, and outputting a notification through a plurality of nodes forming a network and using the network queue memory, the notification configuring communications between the nodes.

Andrade Costa, Carlos H.↗

Ubiquitous condition monitoring - Key to networked-subsystem space propulsion systems

Various highlights of NASA's recently held space transportation propulsion and avionics symposia and the participation in this symposia by industry, the university community, and government organizations are discussed. The potential contributions of the integrated control and health monitoring (ICHM) field are considered. The goals of advanced ICHM technologies are reliability, operability, performance, and affordability. It is proposed that conventional liquid rocket engine configurations, characterized as noninteracting, stand-alone, compactly packaged and usually gimballed sets of hardware, can profit through embracing advanced ICHM capabilities.

Escher, William J. D.↗

Considerations for AMI-Based Operations for Distribution Feeders

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamics of argon metastables in Ar–CH 4 radio frequency capacitively-coupled plasma: real-time monitoring with neural network-augmented broadband optical emission spectroscopy

In moderate-pressure radio frequency (RF) capacitively coupled plasmas generated in argon–methane mixtures, the density of argon metastable atoms (Ar 1 s 5 ) exhibits a non-monotonic dependence on methane (CH 4 ) concentration. Laser-induced fluorescence (LIF) was used to measure and compare local Ar 1 s 5 densities in Ar and Ar–CH 4 plasmas at 2.6 Torr and RF powers of 17–117 W. The addition of 1% CH 4 increases the metastable density, and 2% CH 4 triggers a strong depletion by an order of magnitude, compared to 1% CH 4 case. This non-monotonic behavior demonstrates the sensitivity of metastable populations to small gas admixtures, which is critical for processes where metastables drive precursor dissociation. For real-time monitoring of metastable population, broadband optical emission spectroscopy (OES) is augmented with a feedforward neural network (NN) to predict Ar s1 5 densities from spectral features. When trained on LIF data, the NN replicates the absolute densities and the dynamic trends of Ar 1 s 5 density variation. The NN-augmented broadband OES approach can be used as a simple and cost-effective tool for tracking Ar metastables in Ar-rich plasmas, facilitating industrial-scale optimization.

Yatom, Shurik [Princeton Plasma Physics Laboratory↗

Probabilistic Voltage Sensitivity based Preemptive Voltage Monitoring in Unbalanced Distribution Networks

With increasing penetration of renewable energy and active consumers, control and management of power distribution networks has become challenging. Renewable energy sources can cause random voltage fluctuations as their output power depends on weather conditions. Conventional voltage control schemes such as tap changers and capacitor banks lack the foresight required to quickly alleviate voltage violations. Thus, there is an urgent need for effective approaches for predicting and mitigating voltage violations as a result of random fluctuations in power injections. This work proposes a novel voltage monitoring approach based on low-complexity, data-driven probabilistic voltage sensitivity analysis. The usefulness of this work is not only in predicting voltage violations in unbalanced distribution grids, but also in opening up the door for optimal voltage control. Using system data and forecasts, the proposed approach predicts the distribution of system node voltages which is then used to to identify nodes that may violate the nominal operational limits with high probability. The method is tested on the IEEE 37 node distribution system considering integrated distributed solar energy sources. The method is validated against the classic load flow based method and offers over 95% accuracy in predicting voltage violations.

Abujubbeh, Mohammad↗

Web-Based Interface for Command and Control of Network Sensors

This software allows for the visualization and control of a network of sensors through a Web browser interface. It is currently being deployed for a network of sensors monitoring Mt. Saint Helen s volcano; however, this innovation is generic enough that it can be deployed for any type of sensor Web. From this interface, the user is able to fully control and monitor the sensor Web. This includes, but is not limited to, sending "test" commands to individual sensors in the network, monitoring for real-world events, and reacting to those events

Wallick, Michael N.↗

A machine learning approach to water quality forecasts and sensor network expansion: Case study in the Wabash River Basin, United States

Abstract Midwestern cities require forecasts of surface nitrate loads to bring additional treatment processes online or activate alternative water supplies. Concurrently, networks of nitrate monitoring stations are being deployed in river basins, co‐locating water quality observations with established stream gauges. However, tools to evaluate the future value of expanded networks to improve water quality forecasts remains challenging. Here, we construct a synthetic data set of stream discharge and nitrate for the Wabash River Basin—one of the United States’ most nutrient polluted basins—using the established Agro‐IBIS and THMB models. Synthetic data enables rapid, unbiased and low‐cost assessment of potential sensor placements to support management objectives, such as near‐term forecasting. Using the synthetic data, we established baseline 1‐day forecasts for surface water nitrate at 12 cities in the basin using support vector machine regression (SVMR; RMSE 0.48–3.3 ppm). Next, we used the SVMRs to evaluate the improvement in forecast performance associated with deployment of additional nitrate sensors. We identified the optimal sensor placement to improve forecasts at each city, and the relative value of sensors at each candidate location. Finally, we assessed the co‐benefit realized by other cities when a sensor is deployed to optimize a forecast at one city, finding significant positive externalities in all cases. Ultimately, our study explores the potential for machine learning to make near‐term predictions and critically evaluate the improvement realized by expanding a monitoring network. While we use nitrate pollution in the Wabash River Basin as a case study, this approach could be readily applied to any problem where the future value of sensors and network design are being evaluated.

54 ENVIRONMENTAL SCIENCES↗

Using the Global GPS Network and Other Satellite Data to Monitor Ionospheric Total Electron Content

A globally distributed network of dual-frequency global positioning system (GPS) receivers is the primary source of data used to measure ionospheric total electron content (TEC) on global scales. Maps of TEC useful for calibrating propagation delays, or monitoring the solar-terrestrial environment, can be produced using this continuously operating network. The maps can also form the basis of a TEC calibration service for users around the world. Potential users may include single-frequency satellite altimetry missions, satellite tracking stations, and astronomical observatories.

satellite altimetry↗