At least 253 records · Page 14

Microgrid Tiered Circuits Effects for a Planned Housing Community in Puerto Rico

Puerto Rico faced a double strike from hurricanes Irma and Maria in 2017. The resulting damage required a comprehensive rebuild of electric infrastructure. There are plans and pilot projects to rebuild with microgrids to increase resilience. This paper provides a techno-economic analysis technique and case study of a potential future community in Puerto Rico that combines probabilistic microgrid design analysis with tiered circuits in building energy modeling. Tiered circuits in buildings allow electric load reduction via remote disconnection of non-critical circuits during an emergency. When coupled to a microgrid, tiered circuitry can reduce the chances of a microgrid's storage and generation resources being depleted. The analysis technique is applied to show 1) Approximate cost savings due to a tiered circuit structure and 2) Approximate cost savings gained by simultaneously considering resilience and sustainability constraints in the microgrid optimization. The analysis technique uses a resistive capacitive thermal model with load profiles for four tiers (tier 1-3 and non-critical loads). Three analyses were conducted using: 1) open-source software called Tiered Energy in Buildings and 2) the Microgrid Design Toolkit. For a fossil fuel based microgrid 30% of the total microgrid costs of 1.18 million USD were calculated where the non-tiered case keeps all loads 99.9% available and the tiered case keeps tier 1 at 99.9%, tier 2 at 95%, tier 3 at 80% availability, with no requirement on non-critical loads. The same comparison for a sustainable microgrid showed 8% cost savings on a 5.10 million USD microgrid due to tiered circuits. The results also showed 6-7% cost savings when our analysis technique optimizes sustainability and resilience simultaneously in comparison to doing microgrid resilience analysis and renewables net present value analysis independently. Though highly specific to our case study, similar assessments using our analysis technique can elucidate value of tiered circuits and simultaneous consideration of sustainability and resilience in other locations.

building energy modeling↗

Valuing Residential Energy Efficiency: Analysis for a Prototypical Southeastern Utility [Slides]

The increasing amount of variable renewable energy resources and shifts towards more end-use and vehicle electrification suggests profound changes to power system planning and operation. Specifically, renewable energy is expected to shift net peak demand from late afternoon to early evening and end-use electrification may significantly increase winter peak demand. Residential energy efficiency is likely to align well with these shifts as it tends to produce savings in the early evening (e.g., from lighting measures) and coincident with heating loads (e.g., from envelope and space conditioning measures). Despite the opportunity to decrease system costs and emissions, residential energy efficiency is often limited by static valuation methods and its economic potential is considerably less than its technical potential. Using hourly residential energy efficiency characterizations, utility program cost data, and a capacity expansion model, we estimate the benefits of residential energy efficiency for a prototypical, summer-peaking utility in the Southeastern region. We first establish the cost-effective residential energy efficiency portfolio through “competition” with supply-side resources in a forward-looking capacity expansion model. Importantly, we then evaluate several scenarios intended to drive an increasing amount of cost-effective residential energy efficiency through measure cost reductions, increased customer adoption, policy goals (e.g., carbon price), and delivery of an integrated package of measures. The results quantify total system cost and emissions reductions, fossil-fuel plant retirements, and peak demand reductions. Results suggest the design and prioritization of policies and programs to access the untapped amount of cost-effective residential energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Conceptual design of HTS magnets for fusion nuclear science facility

Second-generation high temperature superconductors (HTS) are available for producing >20 T at the magnet bore compared to 13–16 T for lower temperature superconducting (LTS) toroidal field magnets proposed in recent fusion energy systems studies (FESS) of Fusion Nuclear Science Facility (FNSF). HTS may enable higher fusion power density and smaller device size. High current density cables of multi-layered REBCO tapes have achieved >10 kA at 4–20 K operation in short sample tests for fusion. High current density cables are required for engineering design of FNSF to allow space for interior plasma components. High current density HTS magnets are particularly attractive in reducing the size of a fusion device, beneficial for compact tokamaks, due to their space constraints. Successful HTS magnet development may enable the design of smaller and cheaper fusion pilot plants with a mission of demonstrating net electricity. It may also offer significant cost and performance advantages in non-fusion applicants such as nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Furthermore, we developed HTS magnet design concepts for a compact FNSF radial build in order to define the coil size, winding pack mechanical loading and engineering requirements. Partnering with vendors in the US, PPPL is also testing high current cable prototypes aiming at enabling low cost cable technology toward 100 A/mm 2 engineering current density over the winding pack desired in high field model coil development for compact fusion pilot plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular Alignment of a Meta-Aramid on Carbon Nanotubes by In Situ Interfacial Polymerization

Molecularly organized nanocomposites of polymers and carbon nanotubes (CNTs) have great promise as high-performance materials; in particular, conformal deposition of polymers can control interfacial properties for mechanical load transfer, electrical or thermal transport, or electro/chemical transduction. However, controllability of polymer-CNT interaction remains a challenge with common processing methods that combine CNTs and polymers in melt or in solution, often leading to nonuniform polymer distribution and CNT aggregation. In this work, we demonstrate CNTs within net-shape sheets can be controllably coated with a conformal coating of meta-aramid by simultaneous capillary infiltration and interfacial polymerization. We determine that π-interaction between the polymer and CNTs results in chain alignment parallel to the CNT outer wall. Subsequent nucleation and growth of the precipitated aramid forms a smooth continuous layered sheath around the CNTs. These findings motivate future investigation of mechanical properties of the resulting composites, and adaptation of the in situ polymerization method to other substrates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Future of Zero Energy Buildings: Produce, Respond, Regenerate: Preprint

The zero energy buildings concept is more than 20 years old, and the paradigm shift from buildings as energy consumers to buildings as energy producers is underway. Buildings also consume land and material resources, however, with attendant environmental impacts. Another paradigm is emerging: a built environment that produces energy and is environmentally responsive and regenerative. This paper investigates an updated framework for thinking about zero energy buildings that includes discussions of prioritizing renewables; determining on-site versus off-site generation; exploring how and when buildings should use energy; and balancing renewables, storage, and energy efficiency. Buildings are typically connected to the utility grid and the utility grid develops largely in response to the built environment. If more buildings’ real time electricity use aligned with renewable generation, more renewables would be added to the grid. Ultimately, the goal for zero energy buildings will be to use 100% renewables, 100% of the time, matching loads with energy storage and renewable generation at each discrete timestep over a year. This target is beyond the current zero energy definitions, which focus on an annual balance of renewable supply and energy demand and use the grid to “store” excess production to make up for hours without sufficient on-site renewable generation. This paper expands this upgraded concept and outlines simple metrics to evaluate the alignment of renewable sources and storage with building loads. This process can provide insights on building design considerations, including the use of flexible loads and optimal resource management.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Fully integrated multi-phase buck converter with coupled air core inductors

A multi-phase buck switching converter having grouped pairs of phases, each phase using two magnetically coupled air-core inductors. For each group, a first driver circuit controlling switching of a first power transistor switching circuit coupled to a first air-core inductor output for driving an output load at the first phase. A second driver circuit controlling switching of a second power transistor switching circuit coupled to a second air-core inductor output for driving said output load at the second phase. The first and second phases are spaced 180° apart. The coupled air-core inductors per group of such orientation, separation distance and mutual inductance polarity relative to each other such that magnetic coupling between the two or more inductors at each phase results in a net increase in effective inductance per unit volume. Each air-core inductor is a metal slab of defined length, height and thickness formed using back-end-of-line semiconductor manufacturing process.

Zhang, Xin↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

The U.S. Department of Energy (DOE) has launched a Connected Communities program that supports projects that expand DOE's network of grid-interactive, efficient building communities nationwide. As an early pilot of Connected Communities, the National Renewable Energy Laboratory (NREL) and its partners have developed and demonstrated a community-scale, hierarchical control solution to address the potential grid issues arising from high penetration of solar photovoltaics (PV) as well as to improve grid reliability and resilience in this residential community. A field pilot study has been performed at an affordable housing development called the Basalt Vista Community, which was built for school teachers and other professionals in the local workforce and represents an autonomous energy grid with all-electric, energy-efficient homes. With no natural gas line in the community, this is the first all-electric net-zero community in rural Colorado. In the field pilot study, NREL has validated the performance of the hierarchical control solution, which consists of NREL's foresee home energy management systems (HEMS) and community aggregators, in increasing demand flexibility and self-consuming PV, reducing potential over-voltages, and supporting critical loads during emergency events. In this presentation, we will present the methodology, simulation and field pilot results, and lessons learned from the project.

all-electric community↗

Estimating the impact of tariff-driven behind-the-meter storage operation on distribution grid investments

Increasing growth of distributed solar photovoltaics (PV) and electric vehicles (EV) can strain local distribution networks and require costly upgrades. Distributed battery storage, often deployed alongside PV, can be used to mitigate those costs, depending on how batteries are operated. This study evaluates the potential deferral value of distributed battery storage across a range of tariff structures, focusing on the rate structures most commonly available to residential customers today and related variants. Deferrals are evaluated with a least-cost distribution grid expansion optimization model to identify requirements on line reconductoring, transformer upgrades, and voltage regulator installations under each tariff. Results show that TOU rates and net billing tariffs can yield meaningful deferral value, depending on specific tariff structure features. Under the best performing tariff structure tested, storage produced a median annualized deferral value of $7.18 per kW of storage capacity ( kW S ) across all feeders in the sample, though deferral values were considerably larger for feeders with peak loads that coincide with utility system peak, i.e., timing of TOU peak period. In contrast, under an unrestricted TOU design with no restrictions on grid charging or discharging, the median deferral value was $0/ kW S illustrating the critical importance of tariff structure details.

Rodriguez-Garcia, Luis↗

Design and Operation of Energy Systems with Large Amounts of Variable Generation: IEA Wind TCP Task 25 (Final Summary Report)

This report summarizes findings on wind integration from the 17 countries or sponsors participating in the International Energy Agency Wind Technology Collaboration Program (IEA Wind TCP) Task 25 from 2006-2020. Both real experience and studies are reported. Many wind integration studies incorporate solar energy, and most of the results discussed here are valid for other variable renewables in addition to wind. The national case studies address several impacts of wind power on electric power systems. In this report, they are grouped under long-term planning issues and short-term operational impacts. Long-term planning issues include grid planning and capacity adequacy. Short-term operational impacts include reliability, stability, reserves, and maximizing the value of wind in operational timescales (balancing related issues). The first section presents the variability and uncertainty of power system-wide wind power, and the last section presents recent studies toward 100% shares of renewables. The appendix provides a summary of ongoing research in the national projects contributing to Task 25 for 2021-2024. The design and operation of power and energy systems is an evolving field. As ambitious targets toward net-zero carbon energy systems are announced globally, many scenarios are being made regarding how to reach these future decarbonized energy systems, most of them involving large amounts of variable renewables, mainly wind and solar energy. The secure operation of power systems is increasingly challenging, and the impacts of variable renewables, new electrification loads together with increased distribution system resources will lead to somewhat different challenges for different systems. Tools and methods to study future power and energy systems also need to evolve, and both short-term operational aspects (such as power system stability) and long-term aspects (such as resource adequacy) will probably see new paradigms of operation and design. The experience of operating and planning systems with large amounts of variable generation is accumulating, and research to tackle the challenges of inverter-based, nonsynchronous generation is on the way. Energy transition and digitalization also bring new flexibility opportunities, both short and long term.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Charging for Electric Ride-Hailing Vehicles using Renewables: A San Francisco Case Study

Charging large fleets of electric ride-hailing vehicles (ERVs) is a complex matter that could serve different objectives: lower carbon dioxide emissions, lower monetary expenditures, or maximize solar photovoltaics (PV) energy consumption. Currently, it is unclear how each of those objectives could impact the business and performance of a ride-hailing fleet. In order to fill this gap, this article employs a dynamic transportation model: a smart charging simulation that combines agent-based, discrete-event, and system dynamic modelling by comparing the above-mentioned objectives in separate scenarios. The results show that each scenario successfully manages to shift between 34% and 87% of all load to hours of the day when the objectives of those scenarios are met. Therefore, in comparison to the baseline, smart charging can save between 5% and 26% of monthly emissions and between 4% and 57% of monthly expenditures. The solar PV scenario, however, results in the highest savings, while ensuring profitable economics via net metering in the short- as well as long term. Finally, the sensitivity analysis points to important trade-offs between several fleet performance metrics. The article concludes by giving business and policy recommendations for maximising the economic, energy and environmental efficiency of large ERV fleets.

ADVANCED PROPULSION SYSTEMS,SOLAR ENERGY↗

Fracture Sustainability in Enhanced Geothermal Systems: Experimental and Modeling Constraints

Enhanced geothermal systems (EGS) offer the potential for a much larger energy source than conventional hydrothermal systems. Hot, low-permeability rocks are prevalent at depth around the world, but the challenge of extracting thermal energy depends on the ability to create and sustain open fracture networks. Laboratory experiments were conducted using a suite of selected rock cores (granite, metasediment, rhyolite ash-flow tuff, and silicified rhyolitic tuff) at relevant pressures (uniaxial loading up to 20.7 MPa and fluid pressures up to 10.3 MPa) and temperatures (150–250 °C) to evaluate the potential impacts of circulating fluids through fractured rock by monitoring changes in fracture aperture, mineralogy, permeability, and fluid chemistry. Because a fluid in disequilibrium with the rocks (deionized water) was used for these experiments, there was net dissolution of the rock sample: this increased with increasing temperature and experiment duration. Thermal-hydrological-mechanical-chemical (THMC) modeling simulations were performed for the rhyolite ash-flow tuff experiment to test the ability to predict the observed changes. These simulations were performed in two steps: a thermal-hydrological-mechanical (THM) simulation to evaluate the effects of compression of the fracture, and a thermal-hydrological-chemical (THC) simulation to evaluate the effects of hydrothermal reactions on the fracture mineralogy, porosity, and permeability. Furthermore, these experiments and simulations point out how differences in rock mineralogy, fluid chemistry, and geomechanical properties influence how long asperity-propped fracture apertures may be sustained. Such core-scale experiments and simulations can be used to predict EGS reservoir behavior on the field scale.

15 GEOTHERMAL ENERGY↗

Experimental study of airpath electrification in an opposed-piston two stroke (OP2S) engine architecture

The opposed-piston two stroke (OP2S) engine shows potential as an alternative engine architecture to the conventional four stroke engine due to its high-power density, thermal efficiency, and versatile airpath management system. Since the pistons of a two-stroke engine do not pump the air into and out of the cylinder like in a four-stroke engine, the selection of the air induction devices and airpath actuators becomes critical to optimize engine performance. Both the pumping losses and the in-cylinder combustion process can be affected by the scavenging process in a two-stroke engine. Therefore, this study compares two different airpath configurations for the same family of OP2S engines and investigates performance metrics like scavenging control, pumping work, net indicated and brake efficiencies, and engine-out emissions associated with each airpath. Data was collected on a 3.2 L, two-cylinder OP2S engine with an electrically assisted turbocharger (EAT) and a 4.9 L displacement, three-cylinder engine with a variable geometry turbocharger (VGT) and a supercharger. The experiments consisted of speed and load sweeps for both engines at the same operating conditions to compare scavenge control in both architectures. For the three-cylinder layout, the SE sweep range was much higher, and the intake pressure could be independently varied with air flowrate, thus providing more flexibility for scavenging control. The supercharger and the VGT usage was optimized based on its efficiency map and thus, this layout had lower pumping losses compared to the EAT. The two-cylinder engine had a higher overall SE as compared to the three-cylinder engine, but the intake pressure and air flowrate could not be decoupled, leading to over scavenging and increased short circuiting of fresh charge into the exhaust.

Bhatt, Ankur [Clemson University, Clemson, SC, USA↗

Fundamental study of gas species transport in the oxygen electrode of solid oxide fuel and electrolysis cells

A fundamental analysis of multicomponent gas transport models was performed in application to the oxygen electrodes of solid oxide cells. It is common practice to neglect the effect of pressure gradients within oxygen electrodes, even though a net molar flux at the electrolyte surface implies that a pressure gradient must exist. The influence of both Darcy velocity and Knudsen flux are considered in the context of ordinary (Fickian) diffusion, the dusty gas model, and the binary friction model. Comparisons between the models and different sets of assumptions are made via parametric studies on operating load, oxygen partial pressure, microstructural properties, and electrode thickness. Results show that the pressure gradient will have a significant impact on the oxygen concentration distribution and therefore the concentration overpotential. In electrolysis mode, pressure increases up to 1 atm are predicted, indicating that pressure at the electrode/electrolyte interface could contribute to electrode delamination. Additionally, it is found that Darcy's law is insufficient for calculating the pressure distribution without accounting for the flux due to Knudsen diffusion. Additionally, it is found that for the range of properties typical of oxygen electrodes, there is a negligibly small difference between the dusty gas model and binary friction model from a practical standpoint.

08 HYDROGEN↗

LH CO 2 MENT Colorado Project (Final Report)

The objective of Electricore’s pre-FEED project “LH CO 2 MENT COLORADO PROJECT” is to accelerate the implementation of a 1.5 million tonnes per year (TPY), and first-of-a-kind (FOAK) at world scale, Svante VeloxoTherm™ carbon capture plant. This project represents a quantum leap to a large-scale facility that will launch Svante’s carbon capture technology into the next era of accomplishments and market acceptance. By completing the Front-End Loading (FEL) Feasibility Study Report (FEL-2) for a fit-for-purpose design at the HOLCIM cement plant, located near Florence Colorado, USA, this technology can be proven as the future of large-scale deployment for carbon capture and storage. This carbon capture plant was designed with the goal of reaching a target of near Net Zero Emissions by capturing 90% of the carbon dioxide (CO 2 ) emissions from the HOLCIM cement plant and from the boiler which produces steam required to regenerate the adsorbent. Additionally, this project will be leveraging a renewable Power Purchase Agreement (PPA) using solar energy to acquire power at the target price of 0.04 $/kWh or less. In its current configuration CO 2 emissions from the HOLCIM cement plant is around 700 – 800 kg/ton of clinker produced. The proposed new carbon capture plant will allow a reduction of CO 2 emissions to about 100 kg/ton of clinker produced. The scope of work consists of the process design and capital & operating cost estimation (Class IV) for a total plant capacity of 4,750 TPD of pipeline grade CO 2 . The Svante VeloxoTherm™ technology is comprised of a Rotary Adsorption Machine (RAM) for intensified Thermal Swing Adsorption (TSA) using Structured Adsorbent Beds (SABs) and related Balance of Plant (BOP), including CO 2 compression. A business case (financial analysis) evaluation has been undertaken for the Owner’s management review. Recommendations on how best to proceed to the next stage of the project have been conveyed and are documented within this report. This analysis has relied on a detailed and comprehensive Project Financial Model, evaluating the Total Project IRR (after tax, unlevered, and including all forecast 45Q PTCs and 100% tax efficiency) – the project financial analysis (as opposed to standard TEA analysis) only considered a 12 year plant economic lifetime as a result of 45Q being the sole driver considered at this stage. The Total Project IRR was evaluated across a large number of potential scenarios. The evaluation demonstrated that if the 45Q PTD is increased to $85/MT for sequestration, there are a large number of feasible scenarios which demonstrate economic returns.

01 COAL, LIGNITE, AND PEAT↗

Magnetic Field Amplification by a Plasma Cavitation Instability in Relativistic Shock Precursors

Abstract Plasma streaming instabilities play an important role in magnetic field amplification and particle acceleration in relativistic shocks and their environments. However, in the far shock precursor region where accelerated particles constitute a highly relativistic and dilute beam, streaming instabilities typically become inefficient and operate at very small scales when compared to the gyroradii of the beam particles. We report on a plasma cavitation instability that is driven by dilute relativistic beams and can increase both the magnetic field strength and coherence scale by orders of magnitude to reach near-equipartition values with the beam energy density. This instability grows after the development of the Weibel instability and is associated with the asymmetric response of background leptons and ions to the beam current. The resulting net inductive electric field drives a strong energy asymmetry between positively and negatively charged beam species. Large-scale particle-in-cell simulations are used to verify analytical predictions for the growth and saturation level of the instability and indicate that it is robust over a wide range of conditions, including those associated with pair-loaded plasmas. These results can have important implications for the magnetization and structure of shocks in gamma-ray bursts, and more generally for magnetic field amplification and asymmetric scattering of relativistic charged particles in plasma astrophysical environments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Environmental Impact of Deep Energy Retrofits in Residential Construction

Almost two thirds of the residential homes in the U.S. were constructed before the Department of Energy implemented energy conservation measures that were later formalized in the building codes. To reduce energy consumption and carbon emissions from the built environment, improvement to the existing housing stock is a prerequisite. However, improvements that lower energy consumption address carbon emissions related to heating, cooling and plug loads but not the embodied carbon of the building materials that also contribute to global carbon emissions. As the enclosure is made more efficient a larger portion of total carbon emissions is embodied carbon from the building materials. To mitigate carbon emissions, a holistic approach is required so that any improvement to the home results in a net reduction in carbon emissions. To understand the overall environmental impact of building enclosure improvements, the embodied and operational carbon emissions are calculated in this investigation and compared to the overall energy savings associated with enclosure improvements. The energy savings together with a reduction in operational carbon emissions are calculated using a novel building envelope metric. The net carbon emissions are then determined before and after the energy improvement measures. This approach allows or enables architects and builders to select designs that result in maximizing the overall reduction in energy and carbon emissions.

Aldykiewicz Jr, Antonio↗

A simple vortex model applied to an idealized rotor in sheared inflow

A simple analytical vortex model is presented and used to study an idealized wind turbine rotor in uniform and sheared inflow, respectively. Our model predicts that 1D momentum theory should be applied locally when modelling a non-uniformly loaded rotor in a sheared inflow. Hence the maximum local power coefficient (expressed with respect to the local, upstream velocity) of an ideal rotor is not affected by the presence of shear. We study the interaction between the wake vorticity generated by the rotor and the wind shear vorticity and find that their mutual interaction results in no net generation of axial vorticity: the wake effects and the shear effects exactly cancel each other out. This means that there are no resulting cross-shear-induced velocities and therefore also no cross-shear deflection of the wake in this model.

17 WIND ENERGY↗