Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Net Zero Energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Grid-Forming Inverter-Based Resource Research Landscape: Understanding the Key Assets for Renewable-Rich Power Systems

The shift to net zero energy systems has changed the face of our power grid. Traditional large-scale synchronous generators found inside coal and natural gas plants are being replaced with inverter-based resource (IBR) technologies. This transition to an IBR-dominant power grid introduces new characteristics, altering how our grid operates. Therefore, the role of IBRs has expanded, requiring them to provide a range of essential services to keep our grid reliable, resilient, and secure.

energy management↗

Development of a Low-Lift Chiller Controller and Simplified Precooling Control Algorithm. Final Report

KGS Buildings LLC (KGS) and Pacific Northwest National Laboratory (PNNL) have developed a simplified control algorithm and prototype low-lift chiller controller suitable for model-predictive control in a demonstration project of low-lift cooling. Low-lift cooling is a highly efficient cooling strategy conceived to enable low or net-zero energy buildings. A low-lift cooling system consists of a high efficiency low-lift chiller, radiant cooling, thermal storage, and model-predictive control to pre-cool thermal storage overnight on an optimal cooling rate trajectory. We call the properly integrated and controlled combination of these elements a low-lift cooling system (LLCS). This document is the final report for that project.

25 ENERGY STORAGE↗

Building Operator Certification (BOC®) for Building Technicians

The work completed under this grant expanded the capacity of the Building Operator Certification (BOC®) program to better serve the skill enhancement needs of the commercial building technician workforce to achieve DOE’s goal of net-zero energy commercial buildings. The project created five significant product performance and delivery enhancements which have been fully integrated into the national BOC program and are being actively used in well over 25 states across the country to train and certify building technicians.

None, None↗

STI/DOE Solar decathlon- Final Report

Team Orange successfully designed and constructed a house driven by new design concepts and technical innovations that harmonize with Southern California’s lifestyle and respect its cultural heritage. The basic elements of our 2015 proposal can be summarized as follows: Increased emphasis on the passive solar design concept, with a visually stimulating design that enhances the Southern California lifestyle; Use of design and construction techniques to create a market-ready home for an efficient and affordable lifestyle; Integrated use of new technology to create a behavior-adaptive smart home; A zero net energy house complying with the Living Building philosophy; and compliance with all DOE Solar Decathlon requirements.

14 SOLAR ENERGY↗

Multifamily Heat Pump Water Heater Evaluation

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifamily Heat Pump Water Heater Evaluation

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifamily Heat Pump Water Heater Evaluation

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct Current as an Integrating Platform for ZNE Buildings with EVs and Storage: DC Direct Systems – A Bridge to a Low Carbon Future?

Cost effective zero net energy (ZNE) schemes exist for many types of residential and commercial buildings. Yet, today’s alternating current (AC) based ZNE designs may be as much as 10% to 20% less efficient, more costly, and more complicated than a design based on direct current (DC) technologies. An increasing number of research organizations and manufacturers are just starting the process of developing products and conducting research and development (R&D) efforts. These early R&D efforts indicate that the use of DC technologies may deliver many energy and non-energy benefits relative to AC-based typologies. DC ZNE schemes may provide for an ideal integrating platform for natively DC-based onsite generation, storage, electric vehicle (EV) charging and end-use loads. Emerging empirical data suggest that DC end-use appliances are more efficient, simpler, more durable, and lower cost. DC technologies appear to provide ratepayers a lower cost pathway to achieve resilient ZNE buildings, and simultaneously yield a plethora of benefits. This paper draws from the current research effort entitled "Direct Current as an Integrating and Enabling Platform," co-led by the Lawrence Berkeley National Laboratory (LBNL), the California Institute for Energy and the Environment (CIEE), the Electric Power Research Institute (EPRI) and funded under the California Energy Commission’s Energy Program Investment Charge (CEC EPIC). The first phase of this EPIC research is focused on assembling and summarizing known global performance information on DC and DC-AC hybrid end-use appliances and power systems. This paper summarizes the information and insights gained from this research effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrification of buildings and industry in the United States: Drivers, barriers, prospects, and policy approaches

The report offers several use cases and case studies of electrification in buildings and industry: air source heat pumps for space heating, zero net energy buildings, electric water heaters and demand response, electric arc furnaces, and electric boilers. Finally, the report suggests several areas for further research to better understand and advance beneficial electrification.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Natural Gas Community of the Future (Final Report)

Nicor Gas, a subsidiary of Southern Company Gas and its parent company Southern Company, is developing the concept of the Carbon-neutral, Affordable, Resilient, and Equitable Community ("CARE Community") to address the challenges of accessibility and affordability of grid-interactive efficient buildings in historically disadvantaged communities. The CARE Community is a new construction net-zero energy and carbon neutral residential neighborhood consisting of 50 homes with electricity and natural gas services in South Suburban Chicago, built as low-income affordable housing. The National Renewable Energy Laboratory (NREL) is assisting Southern Company to explore how energy efficiency, renewable technologies, and the reliability and resilience of natural gas can be combined and optimized in an islandable energy system as part of a broader effort to understand the role natural gas plays in future communities integrated with renewable energy and improved energy efficiency. The CARE Community will demonstrate how energy efficiency, distributed energy resources (DERs), and advanced controls can be combined with existing natural gas infrastructure to serve historically disadvantaged communities in a cold climate with low energy cost for affordable housing programs and enhanced resilience to withstand extreme weather. Homes will be a part of an islandable energy system, integrating multiple DER technologies such as solar panels, natural gas fuel cells, reciprocating natural gas engines, and battery storage. The CARE Community will provide a replicable template that affordable housing developers and energy companies can adopt throughout the United States. In this report, we present the design and modeling of the community and potential approaches for integrating DERs. We analyze and discuss annual simulations under normal operating conditions and week-long simulations under electric power grid outage conditions.

03 NATURAL GAS↗

COMFEN 3.0 - Evolution of an Early Design Tool for Commercial Facades and Fenestration Systems

Achieving a net-zero energy building cannot be done solely by improving the efficiency of the engineering systems. It also requires consideration of the essential nature of the building including factors such as architectural form, massing, orientation and enclosure. Making informed decisions about the fundamental character of a building requires assessment of the effects of the complex interaction of these factors on the resulting performance of the building. The complexity of these interactions necessitates the use of modeling and simulation tools to dynamically analyze the effects of the relationships, yet decisions about the building fundamentals are often made in the earliest stages of design, before a `building? exists to model. To address these issues, Lawrence Berkeley National Laboratory (LBNL) has developed an early-design energy modeling tool (COMFEN) specifically to help make informed decisions about building facade fundamentals by considering the design of the building envelope, orientation and massing on building performance. COMFEN focuses on the concept of a ?space? or ?room? and uses the EnergyPlus, and RadianceTM engines and a simple, graphic user interface to allow the user to explore the effects of changing key early-design input variables on energy consumption, peak energy demand, and thermal and visual comfort. Comparative results are rapidly presented in a variety of graphic and tabular formats to help users move toward optimal facade and fenestration design choices.While COMFEN 1.0 utilized an ExcelTM-based user interface, COMFEN 3.0 has been reworked to include a simple, more intuitive, yet powerful Graphic User Interface (GUI), a broader range of libraries for associated system and component choices and deliver a wider range of graphic outputs and options. This paper (and presentation) outlines the objectives in developing and further refining COMFEN, the mechanics of the program, and plans for future development.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Best Practices Case Study: John Wesley Miller Companies - Armory Park Del Sol, Tucson, AZ

Case study of John Wesley Miller Companies, who built two net zero energy homes plus 97 other solar homes in Tucson, AZ. Masonry block walls with rigid foam exterior sheathing, rigid foam over the roof deck plus R-38 in the attic, ducts in conditioned space, 4.2 kW and 5.7 kW photovoltaics and solar water heating yielded HERS scores of 0 on the two homes.

Building America↗

Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

30 DIRECT ENERGY CONVERSION↗

Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

ARBI↗

Strategies Workshop for RetrofitNY Awardees

NREL led a technical workshop for the first six awardees of NYSERDA's RetrofitNY program, which provides funding to teams of forward-thinking retrofit-designers, contractors, and building owners to implement net-zero energy all-electric retrofits on affordable multifamily buildings across NY state.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moving Zero Energy Office Buildings to the Mainstream: Establishing Design Guidelines and Energy Targets: Preprint

Office buildings represent a significant portion of the commercial sector and are ideal candidates to lead the market towards achieving zero energy or zero energy ready buildings. The variety of sizes and uses for office buildings make them challenging to determine set design guidance that can be deployed across the market. A project committee for ASHRAE’s Zero Energy - Advanced Energy Design Guide (ZE-AEDG) for small and medium office buildings , comprised of members from five major national associations with market-pull in commercial buildings, created design guidance for achieving zero energy office buildings for new construction and major retrofit. This design guidance focuses on the process, providing a pathway for both office owners and design teams to achieve zero energy status. Energy use intensity targets range from 16 kBtu/ft²·yr to 36 kBtu/ft²·yr for the different climate zones were established such that office buildings can be “zero-ready,” that is, having low energy consumption that can easily be offset with renewables, preferably on-site. The design guidance was rooted in extensive energy modeling, as well as case studies of actual office buildings that have achieved high levels of energy performance and met zero energy or zero energy ready status. A unique aspect of the zero-energy guide is that it is not compared against a baseline but focuses on achieving an absolute target. The paper presents process of creating the targets, the selection of strategies to achieve the targets, and sample case studies that show how the cost-sensitive solutions are achievable for the design community. It also presents outreach strategies to deploy market achievable zero energy measures.

buildings↗