Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Simulation motion effect on single axis compensatory tracking

An experiment that examined how changes in a motion platform drive filter affect pilot-vehicle performance and opinion was conducted on the NASA Ames Vertical Motion Simulator. Pilots controlled a simplified helicopter model in the vertical or the directional axis and tracked a randomly moving target aircraft in the presence of a random disturbance. With both tasks, variations from full motion to fixed-base conditions were made in the high-pass drive filter gain and natural frequency. The results indicate that vertical motion did not affect the open-loop pilot-vehicle target-tracking crossover frequency, but target-tracking phase margins improved with increased filter gain or decreased natural frequency. Vertical disturbance-rejection crossover frequency increased with decreasing filter natural frequency, while disturbance rejection phase margins improved with increasing filter gain. Vertical tracking errors increased significantly when all vertical motion was removed. No significant differences were measured among the directional configurations, which indicates that pure yaw motion cues may not be as important as previously thought in flight simulation.

Schroeder, Jeffery A.↗

Tracking the protein conformational motions driving HIV-1 membrane fusion

HIV-1 Env (trimeric gp120/gp41) is the surface protein responsible for membrane fusion. The Env binds to the receptor proteins, which induces gp120 shedding leading to conformational changes of gp41 from the pre-fusion to post-fusion state, allowing its fusion peptide to embed in the host cell membrane and bringing the viral and host cell membranes together. The gp41 refolding is a target of several peptide inhibitors. Yet, the molecular mechanism of this dynamic process is still not well understood. In this study, we successfully simulate the conformational change of gp41 from pre-fusion to post-fusion state in atomistic resolution using all-atom structure-based models. We reveal that maintaining the directionality of protomer interactions in both pre-fusion and post-fusion states is crucial for gp41 refolding. Additionally, we find that HR1 inherently extends as a three-helical bundle toward the host-cell membrane without any bias. Importantly, we identify native contacts in the pre-fusion state that are critical for the proper refolding of gp41 towards the post-fusion state. Lastly, by incorporating the membrane-fusion inhibitors, T20 and SFT, we identify the most vulnerable stage in the fusion pathway that exhibits the greatest sensitivity to these drugs, which could aid in a better understanding of drug resistance mechanisms.

59 BASIC BIOLOGICAL SCIENCES↗

Atomic-Scale Tracking of Topological Defect Motion and Incommensurate Charge Order Melting

Charge order pervades the phase diagrams of quantum materials where it competes with superconducting and magnetic phases, hosts electronic phase transitions and topological defects, and couples to the lattice generating intricate structural distortions. Incommensurate charge order is readily stabilized in manganese oxides, where it is associated with anomalous electronic and magnetic properties, but its nanoscale structural inhomogeneity complicates precise characterization and understanding of its relationship with competing phases. Leveraging atomic-resolution variable-temperature cryogenic scanning transmission electron microscopy, we characterize the thermal evolution of charge order as it transforms from its ground state in a model manganite system. We find that mobile networks of discommensurations and dislocations generate phase inhomogeneity and induce global incommensurability in an otherwise lattice-locked modulation. Driving the order to melt at high temperatures, the discommensuration density grows, and regions of order locally decouple from the lattice periodicity. Published by the American Physical Society 2025

Schnitzer, Noah (ORCID:0000000210421146)↗

WE-AB-303-05: Breathing Motion of Liver Segments From Fiducial Tracking During Robotic Radiosurgery and Comparison with 4D-CT-Derived Fiducial Motion

Purpose: To quantify respiratory-induced motion of liver segments using the positions of implanted fiducials during robotic radiosurgery. This study also compared fiducial motion derived from four-dimensional computed tomography (4D-CT) maximum intensity projections (MIP) with motion derived from imaging during treatment. Methods: Forty-two consecutive liver patients treated with liver ablative radiotherapy were accrued to an ethics approved retrospective study. The liver segment in which each fiducial resided was identified. Fiducial positions throughout each treatment fraction were determined using orthogonal kilovoltage images. Any data due to patient repositioning or motion was removed. Mean fiducial positions were calculated. Fiducial positions beyond two standard deviations of the mean were discarded and remaining positions were fit to a line segment using least squares minimization (LSM). For eight patients, fiducial motion was derived from 4D-CT MIPs by calculating the CT number weighted mean position of the fiducial on each slice and fitting a line segment to these points using LSM. Treatment derived fiducial trajectories were corrected for patient rotation and compared to MIP derived trajectories. Results: The mean total magnitude of fiducial motion across all liver segments in left-right, anteroposterior, and superoinferior (SI) directions were 3.0 ± 0.2 mm, 9.3 ± 0.4 mm, and 20.5 ± 0.5 mm, respectively. Differences in per-segment mean fiducial motion were found with SI motion ranging from 12.6 ± 0.8 mm to 22.6 ± 0.9 mm for segments 3 and 8, respectively. Large, varied differences between treatment and MIP derived motion at simulation were found with the mean difference for SI motion being 2.6 mm (10.8 mm standard deviation). Conclusion: The magnitude of liver fiducial motion was found to differ by liver segment. MIP derived liver fiducial motion differed from motion observed during treatment, implying that 4D-CTs may not accurately capture the range of liver motion across fractions and during treatment. Author V. Nair was funded by the Cushing estate for a SABR clinical research fellowship.

60 APPLIED LIFE SCIENCES↗

Knowledge-based vision for space station object motion detection, recognition, and tracking

Computer vision, especially color image analysis and understanding, has much to offer in the area of the automation of Space Station tasks such as construction, satellite servicing, rendezvous and proximity operations, inspection, experiment monitoring, data management and training. Knowledge-based techniques improve the performance of vision algorithms for unstructured environments because of their ability to deal with imprecise a priori information or inaccurately estimated feature data and still produce useful results. Conventional techniques using statistical and purely model-based approaches lack flexibility in dealing with the variabilities anticipated in the unstructured viewing environment of space. Algorithms developed under NASA sponsorship for Space Station applications to demonstrate the value of a hypothesized architecture for a Video Image Processor (VIP) are presented. Approaches to the enhancement of the performance of these algorithms with knowledge-based techniques and the potential for deployment of highly-parallel multi-processor systems for these algorithms are discussed.

Symosek, P.↗

Bi-Component Droplet Combustion Experiment Designed

The combustion of liquid fuels is a major source of energy in the world today, and the majority of these fuels are burned in the form of a spray. The research at the NASA Glenn Research Center in droplet combustion has the overall goal of providing a better understanding of spray combustion by studying the smallest element in a spray, the single droplet. The Bi-Component Droplet Combustion Experiment (BCDCE) extends the work at Glenn from pure, or single-component, fuels to an idealized liquid fuel composed of two completely miscible components. The project is a collaborative effort between Glenn and Prof. B.D. Shaw of the University of California, Davis. The BCDCE project is planned to fly onboard the International Space Station in the Multi-User Droplet Combustion Apparatus. The unique feature of this experiment is that it will be the first droplet combustion experiment to perform a detailed characterization of the flow inside a liquid fuel droplet. The experiment will use a relatively new technique called Digital Particle Imaging Velocimetry (DPIV) to characterize the liquid flow. In this technique, very small (approx. 5-mm diameter) particles are dispersed throughout a liquid droplet. These particles are illuminated by a thin laser sheet. Images of the particle motion are recorded on a computer, which then tracks the motion of the particles to determine the flow characteristics.

Dietrich, Daniel L.↗

Manual Crew Override of Vehicle Landings Following G-Transitions

BACKGROUND Manual control during exploration spaceflight consists of both planned automated supervisory control and unplanned crew override. This crew override capability is critical to enable overall mission success during landing contingencies. However, the introduction of manual override capabilities must be implemented to enable crews to mitigate risks introduced by human error. Adaptive changes in the sensorimotor system can manifest during g-transitions as spatial disorientation. While training and landing aids enable successful landing through disorientation, these adaptive changes may increase cognitive demand that needs to be accounted for in the manual control strategy. It is important to characterize these effects as soon as possible following the G-transition to develop appropriate countermeasures. METHODS The following study seeks to inform the risk associated with altered sensorimotor and vestibular function impacting critical mission tasks. We aim to characterize the effects of short and long-duration weightlessness on manual control following G-transitions using simulated lunar landing on a six-degree-of-freedom (6DOF) motion base, a fixed base simulation, and a supervisory control tablet task. The primary goal is to understand the impact of spaceflight on crew ability to perform manual crew override and supervisory control. This aim will be assessed by comparing pre- versus postflight simulation performance in crewmembers assigned to either short duration (< 30 day) or long duration (~6- month) missions to the International Space Station (ISS). We hypothesize there will be postflight increases in the percent time that pilots are outside of the acceptable range for recommended vehicle state parameters and the reaction time for secondary cognitive tasks. Ground-based control subjects, who are demographically matched to the crew considering age (± 5 years) and gender, will undergo the same testing schedule as the crew to examine the effects of flight phase independent of microgravity exposure. The second aim is to examine how adaptive changes in vestibular and cognitive function relate to changes in manual crew override proficiency. Crew performance for a sensorimotor perceptual test battery will evaluate motion perception tracking, roll nulling, and/or vection sensitivity using the 6DOF motion base. We hypothesize that a higher severity of vestibular alterations will be associated with increased percent time outside of guidance limits. Motion sickness severity and sleepiness will also be evaluated. To determine the impact of “just-in-time” training, the third aim seeks to compare performance during on-board lunar landing tasks conducted late in-flight to early postflight. We hypothesize that proficiency on the “just-in-time” laptop trainer late in mission will be positively correlated with early postflight proficiency on the same task. The final aim will establish assessments of performance, training protocols, and the learning progression in a ground-control cohort of first-time users. RESULTS The assessment of the learning progression associated with the piloting task on the motion base system with thirty ground subjects will be reported. Learning curves will be established across four distinct sessions and within session considering trial difficulty. The difficulty of the landing task can be modulated with the landing divert distance and cross or downrange difficulty. Results may include changes in performance across multiple trials of a multi-attribute lunar tablet supervisory control task. Preliminary investigations of eighteen subjects who completed vestibular threshold and motion perception tasks offer expected performance ranges for upcoming preflight crew evaluations. The results yielded an average roll threshold of 0.46 ± 0.30 deg/s and an average roll nulling root mean square error performance of 2.52 ± 0.52 deg/s. RELEVANCE This project will deliver an operational demonstration of crew monitoring capability following spaceflight and identify potential deficits that may require remediation. Comparison of individual vestibular and cognitive changes with crew performance will help better characterize the manual control risks associated with sensorimotor alterations. Ground testing will evaluate learning progression, refine training protocols, and serve as a control cohort for comparisons to crew performance. ACKNOWLEDGEMENTS: The authors acknowledge contributions from Draper, the Dynamic Skills Trainer (DST) Lab, and the Software, Robotics, and Simulation Division toward the development of the lunar landing simulation platforms. This project is funded by the Human Health Countermeasures Element.

Hannah M. Weiss↗

Simulator study of the effect of visual-motion time delays on pilot tracking performance with an audio side task

The effect of time delay was determined in the visual and motion cues in a flight simulator on pilot performance in tracking a target aircraft that was oscillating sinusoidally in altitude only. An audio side task was used to assure the subject was fully occupied at all times. The results indicate that, within the test grid employed, about the same acceptable time delay (250 msec) was obtained for a single aircraft (fighter type) by each of two subjects for both fixed-base and motion-base conditions. Acceptable time delay is defined as the largest amount of delay that can be inserted simultaneously into the visual and motion cues before performance degradation occurs. A statistical analysis of the data was made to establish this value of time delay. Audio side task provided quantitative data that documented the subject's work level.

Riley, D. R.↗

Polar motion and earth tides from laser tracking

The paper discusses techniques available for measuring polar motion, earth rotation and earth tides with laser tracking of satellites. In a discussion of future prospects, it is noted that when the Laser Geodynamics Satellite is launched, a network of laser stations is projected to be able to achieve better than 10 cm from each coordinate from less than one day of tracking.

Kolenkiewicz, R.↗

SU-G-JeP1-06: Correlation of Lung Tumor Motion with Tumor Location Using Electromagnetic Tracking

Purpose: It is well known that lung tumors move with respiration. However, most measurements of lung tumor motion have studied long treatment times with intermittent imaging; those populations may not necessarily represent conventional LINAC patients. We summarized the correlation between tumor motion and location in a multi-institutional trial with electromagnetic tracking, and identified the patient cohort that would most benefit from respiratory gating. Methods: Continuous electromagnetic transponder data (Varian Medical, Seattle, WA) of lung tumor motion was collected from 14 patients (214 total fractions) across 3 institutions during external beam radiation therapy in a prospective clinical trial (NCT01396551). External intervention from the clinician, such as couch shifts, instructed breath-holds, and acquisition pauses, were manually removed from the 10 Hz tracking data according to recorded notes. The average three-dimensional displacement from the breathing cycle’s end-expiratory to end-inhalation phases (peak-to-peak distance) of the transponders’ isocenter was calculated for each patient’s treatment. A weighted average of each isocenter was used to assess the effects of location on motion. A total of 14 patients were included in this analysis, grouped by their transponders’ location in the lung: upper, medial, and lower. Results: 8 patients had transponders in the upper lung, and 3 patients each in the medial lobe and lower lung. The weighted average ± standard deviation of all peak-to-peak distances for each group was: 1.04 ± 0.39 cm in the lower lung, 0.56 ± 0.14 cm in the medial lung, and 0.30 ± 0.06 cm in the upper lung. Conclusion: Tumors in the lower lung are most susceptible to excessive motion and daily variation, and would benefit most from continuous motion tracking and gating. Those in the medial lobe might be at moderate risk. The upper lobes have limited motion. These results can guide different motion management strategies between lung tumor locations. This is part of an NIH-funded prospective clinical trial (NCT01396551), using an electromagnetic transponder tracking system and additional funding from Varian Medical (Seattle, WA).

60 APPLIED LIFE SCIENCES↗

Object tracking with stereo vision

A real-time active stereo vision system incorporating gaze control and task directed vision is described. Emphasis is placed on object tracking and object size and shape determination. Techniques include motion-centroid tracking, depth tracking, and contour tracking.

Huber, Eric↗

Automatic tracking of implanted fiducial markers in cone beam CT projection images

Purpose: This paper describes a novel method for simultaneous intrafraction tracking of multiple fiducial markers. Although the proposed method is generic and can be adopted for a number of applications including fluoroscopy based patient position monitoring and gated radiotherapy, the tracking results presented in this paper are specific to tracking fiducial markers in a sequence of cone beam CT projection images. Methods: The proposed method is accurate and robust thanks to utilizing the mean shift and random sampling principles, respectively. The performance of the proposed method was evaluated with qualitative and quantitative methods, using data from two pancreatic and one prostate cancer patients and a moving phantom. The ground truth, for quantitative evaluation, was calculated based on manual tracking preformed by three observers. Results: The average dispersion of marker position error calculated from the tracking results for pancreas data (six markers tracked over 640 frames, 3840 marker identifications) was 0.25 mm (at iscoenter), compared with an average dispersion for the manual ground truth estimated at 0.22 mm. For prostate data (three markers tracked over 366 frames, 1098 marker identifications), the average error was 0.34 mm. The estimated tracking error in the pancreas data was < 1 mm (2 pixels) in 97.6% of cases where nearby image clutter was detected and in 100.0% of cases with no nearby image clutter. Conclusions: The proposed method has accuracy comparable to that of manual tracking and, in combination with the proposed batch postprocessing, superior robustness. Marker tracking in cone beam CT (CBCT) projections is useful for a variety of purposes, such as providing data for assessment of intrafraction motion, target tracking during rotational treatment delivery, motion correction of CBCT, and phase sorting for 4D CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Demonstration of Combined kV/MV Image-Guided Real-Time Dynamic Multileaf-Collimator Target Tracking

Purpose: For intrafraction motion management, a real-time tracking system was developed by combining fiducial marker-based tracking via simultaneous kilovoltage (kV) and megavoltage (MV) imaging and a dynamic multileaf collimator (DMLC) beam-tracking system. Methods and Materials: The integrated tracking system employed a Varian Trilogy system equipped with kV/MV imaging systems and a Millennium 120-leaf MLC. A gold marker in elliptical motion (2-cm superior-inferior, 1-cm left-right, 10 cycles/min) was simultaneously imaged by the kV and MV imagers at 6.7 Hz and segmented in real time. With these two-dimensional projections, the tracking software triangulated the three-dimensional marker position and repositioned the MLC leaves to follow the motion. Phantom studies were performed to evaluate time delay from image acquisition to MLC adjustment, tracking error, and dosimetric impact of target motion with and without tracking. Results: The time delay of the integrated tracking system was {approx}450 ms. The tracking error using a prediction algorithm was 0.9 {+-} 0.5 mm for the elliptical motion. The dose distribution with tracking showed better target coverage and less dose to surrounding region over no tracking. The failure rate of the gamma test (3%/3-mm criteria) was 22.5% without tracking but was reduced to 0.2% with tracking. Conclusion: For the first time, a complete tracking system combining kV/MV image-guided target tracking and DMLC beam tracking was demonstrated. The average geometric error was less than 1 mm, and the dosimetric error was negligible. This system is a promising method for intrafraction motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focused Ultrasound Surgery Control Using Local Harmonic Motion: VX2 Tumor Study

The objective of this study was to develop a real-time method for controlling focused ultrasound surgery using ultrasound imaging. The approach uses measurements of localized harmonic motion (LHM) in order to perform controlled FUS exposures by detecting changes in the elastic properties of tissues during coagulation. Methods: Nine New Zealand rabbits with VX2 tumors implanted in the thigh were used for this study. LHM was generated within the tumors by periodic induction of radiation force using a FUS transducer (80-mm focal length, 100-mm diameter, 20-mm central hole, 1.485-MHz). Tissue motion was tracked by collecting and cross-correlating RF signals during the motion using a separate diagnostic transducer (3-kHz PRF, 5-MHz). After locating the tumor in MR images, a series of sonications were performed to treat the tumors using a reduction in LHM amplitude to control the exposure. Results: LHM was successfully used to control the sonications. A LHM amplitude threshold value was determined at which changes were considered significant and then the exposure was started and stopped when the LHM amplitude dropped below the threshold. The appearance of a lesion was then verified by MRI. The feasibility of LHM measurements to control FUS exposure was validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensors and methods for monitoring flying objects

Described herein are sensing methods, sensor systems, and non-transitory, computer-readable, storage media having programs for long-duration, continuous monitoring of flying objects during the day or the night and regardless of weather conditions. The methods and systems are computationally efficient and can provide compact, three-dimensional representations of motion from the observed object. A 3D track of the flying object can be generated from a point-matched pair of stereo composite motion track images and not directly from the videos, wherein each composite motion track image is based on a composite of a plurality of video frames composited in part according to video frame numbers.

Matzner, Shari↗

SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy

Purpose: To determine whether the Microsoft Kinect Version 2 (Kinect v2), a commercial off-the-shelf (COTS) depth sensors designed for entertainment purposes, were robust to the radiotherapy treatment environment and could be suitable for monitoring of voluntary breath-hold compliance. This could complement current visual monitoring techniques, and be useful for heart sparing left breast radiotherapy. Methods: In-house software to control Kinect v2 sensors, and capture output information, was developed using the free Microsoft software development kit, and the Cinder creative coding C++ library. Each sensor was used with a 12m USB 3.0 active cable. A solid water block was used as the object. The depth accuracy and precision of the sensors was evaluated by comparing Kinect reported distance to the object with a precision laser measurement across a distance range of 0.6m to 2.0 m. The object was positioned on a high-precision programmable motion platform and moved in two programmed motion patterns and Kinect reported distance logged. Robustness to the radiation environment was tested by repeating all measurements with a linear accelerator operating over a range of pulse repetition frequencies (6Hz to 400Hz) and dose rates 50 to 1500 monitor units (MU) per minute. Results: The complex, consistent relationship between true and measured distance was unaffected by the radiation environment, as was the ability to detect motion. Sensor precision was < 1 mm and the accuracy between 1.3 mm and 1.8 mm when a distance correction was applied. Both motion patterns were tracked successfully with a root mean squared error (RMSE) of 1.4 and 1.1 mm respectively. Conclusion: Kinect v2 sensors are capable of tracking pre-programmed motion patterns with an accuracy <2 mm and appear robust to the radiotherapy treatment environment. A clinical trial using Kinect v2 sensor for monitoring voluntary breath hold has ethical approval and is open to recruitment. The authors are supported by a National Institute of Health Research (NIHR) Career Development Fellowship (CDF-2013-06-005). Microsoft Corporation donated three sensors. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health.

60 APPLIED LIFE SCIENCES↗

Smooth Pursuit of a Partially Occluded Object

There has long been qualitative evidence that humans can pursue an object defined only by the motion of its parts. We explored this quantitatively using an occluded diamond stimulus. Four subjects (one naive) tracked a line-figure diamond moving along an elliptical path (0.9 Hz) either clockwise (CW) or counterclockwise (CCW) behind either an X-shaped aperture (CROSS) or two vertical rectangular apertures (BARS), which obscured the corners. Although the stimulus consisted of only four line segments (108 cd/square m) moving within a visible aperture (0.2 cd/square m) behind a foreground (38 cd/square m), it is largely perceived as a coherently moving diamond. The inter-saccadic portions of eye-position traces were fit with sinusoids. All subjects tracked object motion with considerable temporal accuracy. The mean phase lag was 5 deg/6 deg (CROSS/BARS) and the mean relative phase between the horizontal and vertical components was +95 deg/+92 deg (CW) and -85 deg/-75 deg (CCW), which is close to perfect. Furthermore, a chi-square analysis showed that 56% of BARS trials were consistent with tracking the correct elliptical shape (p is less than 0.05), although segment motion was purely vertical. These data disprove the main tenet of most models of pursuit: that it is a system that seeks to minimize retinal image motion through negative feedback. Rather, the main drive must be a visual signal which has already integrated spatiotemporal retinal information into an object-motion signal.

Stone, L. S.↗