Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Models, Anatomic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Mapping the global distribution of C 4 vegetation using observations and optimality theory

Plants with the C 4 photosynthesis pathway typically respond to climate change differently from more common C 3 -type plants, due to their distinct anatomical and biochemical characteristics. These different responses are expected to drive changes in global C 4 and C 3 vegetation distributions. However, current C 4 vegetation distribution models may not predict this response as they do not capture multiple interacting factors and often lack observational constraints. Here, we used global observations of plant photosynthetic pathways, satellite remote sensing, and photosynthetic optimality theory to produce an observation-constrained global map of C 4 vegetation. We find that global C 4 vegetation coverage decreased from 17.7% to 17.1% of the land surface during 2001 to 2019. This was the net result of a reduction in C 4 natural grass cover due to elevated CO 2 favoring C 3 -type photosynthesis, and an increase in C 4 crop cover, mainly from corn (maize) expansion. Using an emergent constraint approach, we estimated that C 4 vegetation contributed 19.5% of global photosynthetic carbon assimilation, a value within the range of previous estimates (18–23%) but higher than the ensemble mean of dynamic global vegetation models (14 ± 13%; mean ± one standard deviation). Our study sheds insight on the critical and underappreciated role of C 4 plants in the contemporary global carbon cycle.

54 ENVIRONMENTAL SCIENCES↗

Unification of multi-species vertebrate anatomy ontologies for comparative biology in Uberon

Background: Elucidating disease and developmental dysfunction requires understanding variation in phenotype. Single-species model organism anatomy ontologies (ssAOs) have been established to represent this variation. Multi-species anatomy ontologies (msAOs; vertebrate skeletal, vertebrate homologous, teleost, amphibian AOs) have been developed to represent ‘natural’ phenotypic variation across species. Our aim has been to integrate ssAOs and msAOs for various purposes, including establishing links between phenotypic variation and candidate genes. Results: Previously, msAOs contained a mixture of unique and overlapping content. This hampered integration and coordination due to the need to maintain cross-references or inter-ontology equivalence axioms to the ssAOs, or to perform large-scale obsolescence and modular import. Here we present the unification of anatomy ontologies into Uberon, a single ontology resource that enables interoperability among disparate data and research groups. As a consequence, independent development of TAO, VSAO, AAO, and vHOG has been discontinued. Conclusions: The newly broadened Uberon ontology is a unified cross-taxon resource for metazoans (animals) that has been substantially expanded to include a broad diversity of vertebrate anatomical structures, permitting reasoning across anatomical variation in extinct and extant taxa. Uberon is a core resource that supports single- and cross-species queries for candidate genes using annotations for phenotypes from the systematics, biodiversity, medical, and model organism communities, while also providing entities for logical definitions in the Cell and Gene Ontologies. The ontology release files associated with the ontology merge described in this manuscript are available at: http://purl.obolibrary.org/obo/uberon/releases/2013-02-21/ Current ontology release files are available always available at: http://purl.obolibrary.org/obo/uberon/releases/

59 BASIC BIOLOGICAL SCIENCES↗

Developing a system for in vivo imaging of maize roots containing iodinated contrast media in soil using synchrotron XCT and XRF

We sought to develop a novel experimental system which enabled application of iodinated contrast media to in vivo plant roots intact in soil and was compatible with time-resolved synchrotron X-ray computed tomography imaging. The system was developed to overcome issues of low contrast to noise within X-ray computed tomography images of plant roots and soil environments, the latter of which can complicate image processing and result in the loss of anatomical information. To demonstrate the efficacy of the system we employ the novel use of both synchrotron X-ray computed tomography and synchrotron X-ray fluorescence mapping to capture the translocation of the contrast media through root vasculature into the leaves. With the application of contrast media we identify fluid flow in root vasculature and visualise anatomical features, which are otherwise often only observable in ex vivo microscopy, including: the xylem, metaxylem, pith, fibres in aerenchyma and leaf venation. We are also able to observe interactions between aerenchyma cross sectional area and solute transport in the root vasculature with depth. Our novel system was capable of successfully delivering sufficient contrast media into root and leaf tissues such that anatomical features could be visualised and internal fluid transport observed. We propose that our system could be used in future to study internal plant transport mechanisms and parameterise models for fluid flow in plants.

59 BASIC BIOLOGICAL SCIENCES↗

Poster - 40: Treatment Verification of a 3D-printed Eye Phantom for Proton Therapy

Purpose: Ocular melanoma is a form of eye cancer which is often treated using proton therapy. The benefit of the steep proton dose gradient can only be leveraged for accurate patient eye alignment. A treatment-planning program was written to plan on a 3D-printed anatomical eye-phantom, which was then irradiated to demonstrate the feasibility of verifying in vivo dosimetry for proton therapy using PET imaging. Methods: A 3D CAD eye model with critical organs was designed and voxelized into the Monte-Carlo transport code FLUKA. Proton dose and PET isotope production were simulated for a treatment plan of a test tumour, generated by a 2D treatment-planning program developed using NumPy and proton range tables. Next, a plastic eye-phantom was 3D-printed from the CAD model, irradiated at the TRIUMF Proton Therapy facility, and imaged using a PET scanner. Results: The treatment-planning program prediction of the range setting and modulator wheel was verified in FLUKA to treat the tumour with at least 90% dose coverage for both tissue and plastic. An axial isotope distribution of the PET isotopes was simulated in FLUKA and converted to PET scan counts. Meanwhile, the 3D-printed eye-phantom successfully yielded a PET signal. Conclusions: The 2D treatment-planning program can predict required parameters to sufficiently treat an eye tumour, which was experimentally verified using commercial 3D-printing hardware to manufacture eye-phantoms. Comparison between the simulated and measured PET isotope distribution could provide a more realistic test of eye alignment, and a variation of the method using radiographic film is being developed.

60 APPLIED LIFE SCIENCES↗

New insights into supradense matter from dissecting scaled stellar structure equations

The strong-field gravity in general relativity (GR) realized in neutron stars (NSs) renders the equation of state (EOS) P(ε) of supradense neutron star matter to be essentially nonlinear and refines the upper bound for Φ ≡ P/ε to be much smaller than the special relativity (SR) requirement with linear EOSs, where P and ε are respectively the pressure and energy density of the system considered. Specifically, a tight bound Φ ≲ 0.374 is obtained by perturbatively anatomizing the intrinsic structures of the scaled Tolman–Oppenheimer–Volkoff (TOV) equations without using any input nuclear EOS. New insights gained from this novel analysis provide EOS-model-independent constraints on the properties (e.g., density profiles of the sound speed squared s 2 = dP/dε and trace anomaly Δ = 1/3 – Φ) of cold supradense matter in NS cores. Using the gravity-matter duality in theories describing NSs, we investigate the impact of gravity on supradense matter EOS in NSs. In particular, we show that the NS mass M NS , radius R, and compactness ξ ≡ M NS /R scale with certain combinations of its central pressure and energy density (encapsulating its central EOS). Thus, observational data on these properties of NSs can straightforwardly constrain NS central EOSs without relying on any specific nuclear EOS model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BETO 2021 Peer Review - FCIC Task 6: High Temperature Conversion

The impacts of feedstock variability on pyrolysis processes are significant but poorly defined. Current engineering designs are based on empirical guidelines, useful only over a narrow range of feedstock properties. The objectives of this project are to (1) Develop science-based knowledge of how feedstock attributes and operational parameters impact pyrolysis process reliability and product quality; and (2) Build an experimental and computational toolset that predicts these outcomes, enabling processes to optimize reliability and product quality. Biomass is a complex feedstock. Controlling for and testing the effects of individual attributes is very challenging. This project couples multiscale experimentation and modeling to accurately capture the fundamental physics and chemistry of biomass flow and conversion behavior in feeding and pyrolysis reactor operations. Our focus is on pine residue attributes – anatomical fraction (bark, needles, wood), particle morphology (size/shape distribution, density, porosity), and chemical composition (extractives, biopolymers, alkali metals) – that impact product quality for downstream catalytic upgrading. Because detailed pyrolysis product characterization is limited, cutting-edge analytical techniques are being developed to reveal impactful product attributes. The tools and knowledge developed here will enable integrated pyrolysis-based processes that are more robust, flexible, and market-responsive with respect to feedstock variability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio↗

Lung deformations and radiation-induced regional lung collapse in patients treated with stereotactic body radiation therapy

Purpose: To differentiate radiation-induced fibrosis from regional lung collapse outside of the high dose region in patients treated with stereotactic body radiation therapy (SBRT) for lung tumors. Methods: Lung deformation maps were computed from pre-treatment and post-treatment computed tomography (CT) scans using a point-to-point translation method. Fifty anatomical landmarks inside the lung (vessel or airway branches) were matched on planning and follow-up scans for the computation process. Two methods using the deformation maps were developed to differentiate regional lung collapse from fibrosis: vector field and Jacobian methods. A total of 40 planning and follow-ups CT scans were analyzed for 20 lung SBRT patients. Results: Regional lung collapse was detected in 15 patients (75%) using the vector field method, in ten patients (50%) using the Jacobian method, and in 12 patients (60%) by radiologists. In terms of sensitivity and specificity the Jacobian method performed better. Only weak correlations were observed between the dose to the proximal airways and the occurrence of regional lung collapse. Conclusions: The authors presented and evaluated two novel methods using anatomical lung deformations to investigate lung collapse and fibrosis caused by SBRT treatment. Differentiation of these distinct physiological mechanisms beyond what is usually labeled “fibrosis” is necessary for accurate modeling of lung SBRT-induced injuries. With the help of better models, it becomes possible to expand the therapeutic benefits of SBRT to a larger population of lung patients with large or centrally located tumors that were previously considered ineligible.

60 APPLIED LIFE SCIENCES↗

SU-C-209-02: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images

Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motion model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.

AI↗

Evaluation of a commercial automatic treatment planning system for prostate cancers

Recent developments in Radiation Oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning. Such solutions include site-specific modules, plan library methods, and algorithm-based methods. In this study, the plan quality for prostate cancer generated by the Auto-Planning module of the Pinnacle{sup 3} radiation therapy treatment planning system (v9.10, Fitchburg, WI) is retrospectively evaluated. The Auto-Planning module of Pinnacle{sup 3} uses a progressive optimization algorithm. Twenty-three prostate cancer cases, which had previously been planned and treated without lymph node irradiation, were replanned using the Auto-Planning module. Dose distributions were statistically compared with those of manual planning by the paired t-test at 5% significance level. Auto-Planning was performed without any manual intervention. Planning target volume (PTV) dose and dose to rectum were comparable between Auto-Planning and manual planning. The former, however, significantly reduced the dose to the bladder and femurs. Regression analysis was performed to examine the correlation between volume overlap between bladder and PTV divided by the total bladder volume and resultant V70. The findings showed that manual planning typically exhibits a logistic way for dose constraint, whereas Auto-Planning shows a more linear tendency. By calculating the Akaike information criterion (AIC) to validate the statistical model, a reduction of interoperator variation in Auto-Planning was shown. We showed that, for prostate cancer, the Auto-Planning module provided plans that are better than or comparable with those of manual planning. By comparing our results with those previously reported for head and neck cancer treatment, we recommend the homogeneous plan quality generated by the Auto-Planning module, which exhibits less dependence on anatomic complexity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Biochemical and physiological flexibility accompanies reduced cellulose biosynthesis in Brachypodium cesa1 S830N

Here, we present a study into the mechanisms of primary cell wall cellulose formation in grasses, using the model cereal grass Brachypodium distachyon. The exon found adjacent to the BdCESA1 glycosyltransferase QXXRW motif was targeted using Targeting Induced Local Lesions in Genomes (TILLING) and sequencing candidate amplicons in multiple parallel reactions (SCAMPRing) leading to the identification of the Bdcesa1 S830N allele. Plants carrying this missense mutation exhibited a significant reduction in crystalline cellulose content in tissues that rely on the primary cell wall for biomechanical support. However, Bdcesa1 S830N plants failed to exhibit the predicted reduction in plant height. In a mechanism unavailable to eudicotyledons, B. distachyon plants homozygous for the Bdcesa1 S830N allele appear to overcome the loss of internode expansion anatomically by increasing the number of nodes along the stem. Stem biomechanics were resultantly compromised in Bdcesa1 S830N . The Bdcesa1 S830N missense mutation did not interfere with BdCESA1 gene expression. However, molecular dynamic simulations of the CELLULOSE SYNTHASE A (CESA) structure with modelled membrane interactions illustrated that Bdcesa1 S830N exhibited structural changes in the translated gene product responsible for reduced cellulose biosynthesis. Molecular dynamic simulations showed that substituting S830N resulted in a stabilizing shift in the flexibility of the class specific region arm of the core catalytic domain of CESA, revealing the importance of this motion to protein function.

59 BASIC BIOLOGICAL SCIENCES↗

High‐Speed Embedded Ink Writing of Anatomic‐Size Organ Constructs

Embedded ink writing (EIW) is an emerging 3D printing technique that fabricates complex 3D structures from various biomaterial inks but is limited to a printing speed of ∼10 mm s −1 due to suboptimal rheological properties of particulate-dominated yield-stress fluids when used as liquid baths. In this work, a particle-hydrogel interactive system to design advanced baths with enhanced yield stress and extended thixotropic response time for realizing high-speed EIW is developed. In this system, the interactions between particle additive and three representative polymeric hydrogels enable the resulting nanocomposites to demonstrate different rheological behaviors. Accordingly, the interaction models for the nanocomposites are established, which are subsequently validated by macroscale rheological measurements and advanced microstructure characterization techniques. Filament formation mechanisms in the particle-hydrogel interactive baths are comprehensively investigated at high printing speeds. To demonstrate the effectiveness of the proposed high-speed EIW method, an anatomic-size human kidney construct is successfully printed at 110 mm s −1 , which only takes ∼4 h. This work breaks the printing speed barrier in current EIW and propels the maximum printing speed by at least 10 times, providing an efficient and promising solution for organ reconstruction in the future.

36 MATERIALS SCIENCE↗

TU-F-17A-03: A 4D Lung Phantom for Coupled Registration/Segmentation Evaluation

Purpose: Coupling the processes of segmentation and registration (regmentation) is a recent development that allows improved efficiency and accuracy for both steps and may improve the clinical feasibility of online adaptive radiotherapy. Presented is a multimodality animal tissue model designed specifically to provide a ground truth to simultaneously evaluate segmentation and registration errors during respiratory motion. Methods: Tumor surrogates were constructed from vacuum sealed hydrated natural sea sponges with catheters used for the injection of PET radiotracer. These contained two compartments allowing for two concentrations of radiotracer mimicking both tumor and background signals. The lungs were inflated to different volumes using an air pump and flow valve and scanned using PET/CT and MRI. Anatomical landmarks were used to evaluate the registration accuracy using an automated bifurcation tracking pipeline for reproducibility. The bifurcation tracking accuracy was assessed using virtual deformations of 2.6 cm, 5.2 cm and 7.8 cm of a CT scan of a corresponding human thorax. Bifurcations were detected in the deformed dataset and compared to known deformation coordinates for 76 points. Results: The bifurcation tracking accuracy was found to have a mean error of −0.94, 0.79 and −0.57 voxels in the left-right, anterior-posterior and inferior-superior axes using a 1×1×5 mm3 resolution after the CT volume was deformed 7.8 cm. The tumor surrogates provided a segmentation ground truth after being registered to the phantom image. Conclusion: A swine lung model in conjunction with vacuum sealed sponges and a bifurcation tracking algorithm is presented that is MRI, PET and CT compatible and anatomically and kinetically realistic. Corresponding software for tracking anatomical landmarks within the phantom shows sub-voxel accuracy. Vacuum sealed sponges provide realistic tumor surrogate with a known boundary. A ground truth with minimal uncertainty is thus realized that can be used for comparing the performance of registration and segmentation algorithms.

60 APPLIED LIFE SCIENCES↗

SU-C-BRA-05: Delineating High-Dose Clinical Target Volumes for Head and Neck Tumors Using Machine Learning Algorithms

Purpose: To develop and test population-based machine learning algorithms for delineating high-dose clinical target volumes (CTVs) in H&N tumors. Automating and standardizing the contouring of CTVs can reduce both physician contouring time and inter-physician variability, which is one of the largest sources of uncertainty in H&N radiotherapy. Methods: Twenty-five node-negative patients treated with definitive radiotherapy were selected (6 right base of tongue, 11 left and 9 right tonsil). All patients had GTV and CTVs manually contoured by an experienced radiation oncologist prior to treatment. This contouring process, which is driven by anatomical, pathological, and patient specific information, typically results in non-uniform margin expansions about the GTV. Therefore, we tested two methods to delineate high-dose CTV given a manually-contoured GTV: (1) regression-support vector machines(SVM) and (2) classification-SVM. These models were trained and tested on each patient group using leave-one-out cross-validation. The volume difference(VD) and Dice similarity coefficient(DSC) between the manual and auto-contoured CTV were calculated to evaluate the results. Distances from GTV-to-CTV were computed about each patient’s GTV and these distances, in addition to distances from GTV to surrounding anatomy in the expansion direction, were utilized in the regression-SVM method. The classification-SVM method used categorical voxel-information (GTV, selected anatomical structures, else) from a 3×3×3cm3 ROI centered about the voxel to classify voxels as CTV. Results: Volumes for the auto-contoured CTVs ranged from 17.1 to 149.1cc and 17.4 to 151.9cc; the average(range) VD between manual and auto-contoured CTV were 0.93 (0.48–1.59) and 1.16(0.48–1.97); while average(range) DSC values were 0.75(0.59–0.88) and 0.74(0.59–0.81) for the regression-SVM and classification-SVM methods, respectively. Conclusion: We developed two novel machine learning methods to delineate high-dose CTV for H&N patients. Both methods showed promising results that hint to a solution to the standardization of the contouring process of clinical target volumes. Varian Medical Systems grant.

60 APPLIED LIFE SCIENCES↗

Adipocytes promote nicotine-induced injury of endothelial cells via the NF-κB pathway

Cigarette smoking is one of the most important risk factors of atherosclerosis, which can induce endothelial injury. Meanwhile, adipocytes are the main cell type of perivascular adipose tissue (PVAT), the largest endocrine and paracrine organ and direct anatomical connection to adventitia, which may play a key role in the injury of endothelial cells. We used nicotine to induce dysfunctional HUVECs and adipocytes. In addition, we used a novel model to co-culture HUVECs and adipocytes in vitro by the transwell co-culture system to determine the effect of adipocytes on endothelial injury. Cell apoptosis was detected by Annexin V-FITC. Genes and proteins involved in the nuclear factor kappa B (NF-κB) signaling pathway were detected by qRT-PCR and western blot analysis, respectively. We also investigated the nuclear translocation of NF-κB p65 using immunofluorescence staining. Our results showed that nicotine dose-dependently induces the apoptosis of HUVECs and adipocytes and is associated with increased IKKβ and NF-κB p65 expression and with IkBα degradation. Meanwhile through the co-culture system, adipocytes promoted the expression of IKKβ and NF-κB p65, as well as the translocation of NF-κB p65, and they accelerated the degradation of IkBα, resulting in increased apoptosis of HUVECs compared with that of the single cultured system. In conclusion, adipocytes could promote endothelial injury via the NF-κB pathway. Moreover, the NF-κB pathway plays pivotal roles in nicotine-induced vascular injury. - Highlights: • Nicotine induces endothelial injury by activating NF-κB pathway. • Nicotine induces adipocytes injury by activating NF-κB pathway. • Adipocytes promote nicotine-induced endothelial injury via NF-κB pathway.

60 APPLIED LIFE SCIENCES↗

Automatic anatomy recognition in whole-body PET/CT images

Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process, to bring performance to the level achieved on diagnostic CT and MR images in body-region-wise approaches. The intermodality approach fosters the use of already existing fuzzy models, previously created from diagnostic CT images, on PET/CT and other derived images, thus truly separating the modality-independent object assembly anatomy from modality-specific tissue property portrayal in the image. Results: Key ways of combining the above three basic ideas lead them to 15 different strategies for recognizing objects in PET/CT images. Utilizing 50 diagnostic CT image data sets from the thoracic and abdominal body regions and 16 whole-body PET/CT image data sets, the authors compare the recognition performance among these 15 strategies on 18 objects from the thorax, abdomen, and pelvis in object localization error and size estimation error. Particularly on texture membership images, object localization is within three voxels on whole-body low-dose CT images and 2 voxels on body-region-wise low-dose images of known true locations. Surprisingly, even on direct body-region-wise PET images, localization error within 3 voxels seems possible. Conclusions: The previous body-region-wise approach can be extended to whole-body torso with similar object localization performance. Combined use of image texture and intensity property yields the best object localization accuracy. In both body-region-wise and whole-body approaches, recognition performance on low-dose CT images reaches levels previously achieved on diagnostic CT images. The best object recognition strategy varies among objects; the proposed framework however allows employing a strategy that is optimal for each object.

61 RADIATION PROTECTION AND DOSIMETRY↗

Anatomizing Exotic Production of the Higgs Boson

We discuss exotic production modes of the Higgs boson and how their phenomenology can be probed in current Higgs analyses. We highlight the importance of differential distributions in disentangling standard production mechanisms from exotic modes. We present two model benchmarks for exotic Higgs production arising from chargino-neutralino production and study their impact on the current Higgs dataset. As a corollary, we emphasize that current Higgs coupling fits do not fully explore the space of new physics deviations possible in Higgs data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗