At least 253 records · Page 14

CY2018 Annual Closure Monitoring Report for Corrective Action Unit 98, Frenchman Flat, Underground Test Area, Nevada National Security Site, Nevada (January 2018–December 2018, Revision 1)

Corrective Action Unit (CAU) 98: Frenchman Flat on the Nevada National Security Site was the location of 10 underground nuclear tests. CAU 98 underwent a series of investigations and actions in accordance with the Federal Facility Agreement and Consent Order to assess contamination of groundwater by radionuclides from the tests. A Closure Report completed that process in 2016 and called for long-term monitoring, use restrictions (URs), and institutional controls to protect the public and environment from potential exposure to contaminated groundwater. Three types of monitoring are performed for CAU 98: water quality, water level, and institutional control. These are monitored to determine whether the URs remain protective of human health and the environment, and to ensure that the regulatory boundary objectives are being met. Monitoring data will be used in the future, once multiple years of data are available, to evaluate consistency with the groundwater flow and contaminant transport models because the contaminant boundaries calculated with the models are the primary basis of the UR boundaries. Six wells were sampled for water-quality monitoring in 2018. Contaminants of concern were detected only in the two source/plume wells already known to contain contamination as a result of a radionuclide migration experiment. Tritium concentrations in both of these wells, RNM-2S and UE-5n, remain above the Safe Drinking Water Act maximum contaminant level of 20,000 picocuries per liter but declined in 2018 as compared to measurements in 2017. All other contaminants of concern are below the minimum detection level plus analytical error. The water-level monitoring network includes 16 wells. Depth to water measured in 2018 is generally consistent with recent measurements for all wells. Many wells continue to exhibit a long-term downward trend in water level, despite small increases in measured water levels in 2018. The sharp 2016 decline in water level in Well ER-5-3-2 remains unexplained, with the lower level persisting through 2018. Rising water-level trends continue to be observed in two relatively deep wells (ER-5-3 deep piezometer and ER-5-4-2), and also in former supply Well WW-5A. The current supply wells exhibit relatively erratic water levels associated with pumping activities. Institutional control monitoring confirmed the URs are recorded in U.S. Department of Energy and U.S. Air Force land management systems, and that no activities within Frenchman Flat basin are occurring that could potentially affect the contaminant boundaries. Survey of groundwater resources in basins surrounding Frenchman Flat similarly identify no current or pending development that would indicate the need to increase monitoring activities or would otherwise cause concern for the closure decision. The URs continue to prevent exposure of the public, workers, and the environment to contaminants of concern by preventing use of potentially contaminated groundwater.

54 ENVIRONMENTAL SCIENCES↗

Investigation of the solar influence on the cosmic muon flux using WILLI detector

A fesibility study to explore the capability of the WILLI detector to observe the solar events/activity by recording the muon intensity at ground level is presented.The WILLI detector, set up in National Institute of Physics and Nuclear Engineering, Bucharest, is a 1 m{sup 2} incident area sampling calorimeter. It can measure simultaneously muon events with the muon energy {>=}0.4 GeV and, if the muons are stopped in the detector, and muon energy between 0.4<E{sub {mu}<}0.6 GeV, if the muons pass the minimum of 2 plates of the detector stack.Taking into account muon events with energy {>=}0.4 GeV, a modulation of the muon intensity as a diurnal variation is observed. Muon events for a smaller energy range (0.4-0.6 GeV) seem to exhibit an aperiodic variation of the muon intensity, which could be correlated with magnetic activity indicated by the planetary K{sub p} index.

79 ASTRONOMY AND ASTROPHYSICS↗

Novel Approaches to Cellular Transplantation from the US Space Program

Research in the treatment of type I diabetes is entering a new era that takes advantage of our knowledge in an ever increasing variety of scientific disciplines. Some may originate from very diverse sources, one of which is the Space Program at National Aeronautics and Space Administration (NASA). The Space Program contributes to diabetes-related research in several treatment modalities. As an ongoing effort for medical monitoring of personnel involved in space exploration activities NASA and the extramural scientific community investigate strategies for noninvasive estimation of blood glucose levels. Part of the effort in the space protein crystal growth program is high-resolution structural analysis insulin as a means to better understand the interaction with its receptor and with host immune components and as a basis for rational design of a "better" insulin molecule. The Space Program is also developing laser technology for potential early cataract detection as well as a noninvasive analyses for addressing preclinical diabetic retinopathy. Finally, NASA developed an exciting cell culture system that affords some unique advantages in the propagation and maintenance of mammalian cells in vitro. The cell culture system was originally designed to maintain cell suspensions with a minimum of hydrodynamic and mechanical sheer while awaiting launch into microgravity. Currently the commercially available NASA bioreactor (Synthecon, Inc., Houston, TX) is used as a research tool in basic and applied cell biology. In recent years there is continued strong interest in cellular transplantation as treatment for type I diabetes. The advantages are the potential for successful long-term amelioration and a minimum risk for morbidity in the event of rejection of the transplanted cells. The pathway to successful application of this strategy is accompanied by several substantial hurdles: (1) isolation and propagation of a suitable uniform donor cell population; (2) management of host immune rejection; (3) protection from the autoimmune component of the disease; and (4) anatomic placement of the engrafted cells that permits timely response to blood sugar levels as well as effective release and deployment of insulin. Bioreactor technology may provide some critical advances for surmounting some of these scientific hurdles. The NASA bioreactor is a horizontally rotating cylinder that is completely filled with culture medium. Gaseous exchange is maintained by a concentric cylinder of permeable silicon. In slow rotation (15-25 rpm) particles of small mass such as cells and tissue aggregates remain suspended in the rotating body of fluid. This novel approach suspends cells without stirring thus, allowing objects of different size mass to colocate and interact in a very low shear environment. In fact, analysis of the forces acting on individual cells in the rotating bioreactor reveals that the cells are continuously falling through the fluid medium. The conditions in the bioreactor permit assembly of cells into aggregates. three-dimensional tissue growth, synthesis of intercellular matrix,10 differentiation, and some sinusoid formations that may serve as a surrogate vasculature for larger tissue segments.

Pellis, Neal R.↗

TURBULENT DIFFUSION IN THE PHOTOSPHERE AS DERIVED FROM PHOTOSPHERIC BRIGHT POINT MOTION

On the basis of observations of solar granulation obtained with the New Solar Telescope of Big Bear Solar Observatory, we explored proper motion of bright points (BPs) in a quiet-sun area, a coronal hole, and an active region plage. We automatically detected and traced BPs and derived their mean-squared displacements as a function of time (starting from the appearance of each BP) for all available time intervals. In all three magnetic environments, we found the presence of a super-diffusion regime, which is the most pronounced inside the time interval of 10-300 s. Super-diffusion, measured via the spectral index, {gamma}, which is the slope of the mean-squared displacement spectrum, increases from the plage area ({gamma} = 1.48) to the quiet-sun area ({gamma} = 1.53) to the coronal hole ({gamma} = 1.67). We also found that the coefficient of turbulent diffusion changes in direct proportion to both temporal and spatial scales. For the minimum spatial scale (22 km) and minimum time scale (10 s), it is 22 and 19 km{sup 2} s{sup -1} for the coronal hole and the quiet-sun area, respectively, whereas for the plage area it is about 12 km{sup 2} s{sup -1} for the minimum time scale of 15 s. We applied our BP tracking code to three-dimensional MHD model data of solar convection and found the super-diffusion with {gamma} = 1.45. An expression for the turbulent diffusion coefficient as a function of scales and {gamma} is obtained.

79 ASTRONOMY AND ASTROPHYSICS↗

Polonium–lead extractions to determine the best method for the quantification of clean lead used in low-background radiation detectors

Very sensitive detectors are used for low-background applications including the detection of environmental radioactivity, double-beta decay, and dark matter. In order to reduce the background noise enough to utilize the sensitivity of these detectors, lead with little or no alpha activity is required to form the shielding. In the past, antiquity lead shielding was used for low-background detectors because lead’s most prominent alpha-emitting isotope, 210Pb, has a short half-life. The microelectronics industry is also greatly affected by alpha activity in lead and solder, and has begun producing “clean” lead for purchase. To quantify how clean the available lead is, 210Pb and, during procedural experiments, a 209Po tracer must be physically or chemically removed from the bulk lead. A reliable procedure for chemical separations that does not use large volumes of ultra-high-purity chemicals has not yet been established. Lead was dissolved and a known amount of 209Po tracer was added. The samples were put through each of two new procedures. The first procedure was based on complete dissolution of the lead followed by a column separation. The second method investigates the utility of a pre-separation step using precipitation of the lead prior to column separation. The resulting solutions were run through strontium resin columns from Eichrom Inc., a United States Transuranium and Uranium Registries (USTUR) electrodeposition procedure, and scheduled to be alpha counted for a minimum of three days. Though neither of the tested procedures had acceptable logistics for large scale implementation, later alpha counting will show which procedure is more promising for further development

Miley, Sarah M↗

FAR-ULTRAVIOLET H{sub 2} EMISSION FROM CIRCUMSTELLAR DISKS

We analyze the far-ultraviolet (FUV) spectra of 33 classical T Tauri stars (CTTS), including 20 new spectra obtained with the Advanced Camera for Surveys Solar Blind Channel (ACS/SBC) on the Hubble Space Telescope. Of the sources, 28 are in the approx1 Myr old Taurus-Auriga complex or Orion Molecular Cloud, 4 in the 8-10 Myr old Orion OB1a complex, and 1, TW Hya, in the 10 Myr old TW Hydrae Association. We also obtained FUV ACS/SBC spectra of 10 non-accreting sources surrounded by debris disks with ages between 10 and 125 Myr. We use a feature in the FUV spectra due mostly to electron impact excitation of H{sub 2} to study the evolution of the gas in the inner disk. We find that the H{sub 2} feature is absent in non-accreting sources, but is detected in the spectra of CTTS and correlates with accretion luminosity. Since all young stars have active chromospheres which produce strong X-ray and UV emission capable of exciting H{sub 2} in the disk, the fact that the non-accreting sources show no H{sub 2} emission implies that the H{sub 2} gas in the inner disk has dissipated in the non-accreting sources, although dust (and possibly gas) remains at larger radii. Using the flux at 1600 A, we estimate that the column density of H{sub 2} left in the inner regions of the debris disks in our sample is less than approx3 x 10{sup -6} g cm{sup -2}, 9 orders of magnitude below the surface density of the minimum mass solar nebula at 1 AU.

79 ASTRONOMY AND ASTROPHYSICS↗

SOLAR CYCLE VARIATION OF THE INTER-NETWORK MAGNETIC FIELD

The solar inter-network magnetic field is the weakest component of solar magnetism, but it contributes most of the solar surface magnetic flux. The study of its origin has been constrained by the inadequate tempospatial resolution and sensitivity of polarization observations. With dramatic advances in spatial resolution and detecting sensitivity, the solar spectropolarimetry provided by the Solar Optical Telescope on board Hinode in an interval from the solar minimum to maximum of cycle 24 opens an unprecedented opportunity to study the cyclic behavior of the solar inter-network magnetic field. More than 1000 Hinode magnetograms observed from 2007 January to 2014 August are selected in the study. It has been found that there is a very slight correlation between sunspot number and magnetic field at the inter-network flux spectrum. From solar minimum to maximum of cycle 24, the flux density of the solar inter-network field is invariant, at 10 ± 1 G. The observations suggest that the inter-network magnetic field does not arise from flux diffusion or flux recycling of solar active regions, thereby indicating the existence of a local small-scale dynamo. Combining the full-disk magnetograms observed by the Solar and Heliospheric Observatory/Michelson Doppler Imager and the Solar Dynamics Observatory/Helioseismic and Magnetic Imager in the same period, we find that the area ratio of the inter-network region to the full disk of the Sun apparently decreases from solar minimum to maximum but always exceeds 60%, even in the phase of solar maximum.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.

60 APPLIED LIFE SCIENCES↗

Electrooptical effect in the plasmon structure glass–In{sub 2}O{sub 3}: Sn–ferroelectric–Al with a subwavelength grating

The spectral features of the electrooptical effect, in which an applied voltage changes the refractive index of a ferroelectric copolymer, are studied. Three nanostructures are investigated: two nanostructures play an auxiliary role, and the basic structure consists of a glass substrate, a transparent ITO (In{sub 2}O{sub 3}: Sn) layer, active copolymer layer, and an Al layer with a nanograting. This grating with a period of 400 nm meets the conditions of excitation of plasmon resonances. The light transmission coefficients of all structures are analyzed in the spectral range 400–900 nm. The transmission spectra have two characteristic plasmon dips, one of which is related to the copolymer–ITO interface and the other, to the copolymer–Al interface. The aluminum and ITO layers play the role of electrodes, which supply voltage pulses (from 0 to 15 V) to the copolymer layer. When studying the electrooptical effect, we detected spectral shifts in plasmon resonance bands when the amplitudes of both positive and negative voltage pulses (quadratic effect) increase. These shifts change the effective refractive indices (n{sub eff}) of the structural elements, reaching the minimum negative increment Δ{sub eff} =–0.06.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-term total solar irradiance variability during sunspot cycle 22

Total solar irradiance measurements from the 1984-1993 Earth Radiation Budget Satellite (ERBS) active cavity radiometer and 1978-1993 Nimbus 7 transfer cavity radiometer spacecraft experiments are analyzed to detect the presence of 11-, 22-, and 80-year irradiance variability components. The analyses confirmed the existence of a significant 11-year irradiance variability component, associated with solar magnetic activity and the sunspot cycle. The analyses also suggest the presence of a 22- or 80-year variability component. The earlier Nimbus 7 and Solar Maximum Mission (SMM) spacecraft irradiance measurements decreased approximately 1.2 and 1.3 W/sq m, respectively, between 1980 and 1986. The Nimbus 7 values increased 1.2 W/sq m between 1986 and 1989. The ERBS irradiance measurements increased 1.3 W/sq m during 1986-1989, and then decreased 0.4 W/sq m (at an annual rate of 0.14 W/sq. m/yr) during 1990-1993. Considering the correlations between ERBS, Nimbus 7, and SMM irradiance trends and solar magnetic activity, the total solar irradiance should decrease to minimum levels by 1997 as solar activity decreases to minimum levels, and then increase to maximum levels by the year 2000 as solar activity rises. The ERBS measurements yielded 165.4 +/- 0.7 W/sq m as the mean irradiance value with measurement accuracies and precisions of 0.2% and 0.02%, respectively. The ERBS mean irradiance value is within 0.2% of the 1367.4, 1365.9, and 1366.9 W/sq m mean values for the SMM, Upper Atmosphere Research Satellite (UARS), and Space Shuttle Atmospheric Laboratory for Applications and Science (ATLAS 1) Solar Constant (SOLCON) active cavity radiometer spacecraft experiments, respectively. The Nimbus 7 measurements yielded 1372.1 W/sq m as the mean value with a measurement accuracy of 0.5%. Empirical irradiance model fits, based upon 10.7 -cm solar radio flux (F10) and photometric sunspot index (PSI), were used to assess the quality of the ERBS, Numbus 7, SMM, and the UARS irradiance data sets and to identify irradiance variability trends which may be caused by drifts or shifts in the spacecraft sensor responses. Comparisons among the fits and measured irradiances indicate that the Nimbus 7 radiometer response shifted by a total of 0.8 W/sq m between September 1989 and April 1990 and that the ERBS and UARS radiometers each drifted approximately 0.5 W/sq m during the first 5 months in orbit.

Lee, Robert B., III↗

The X-ray absorption spectrum of 4U1700-37 and its implications for the stellar wind of the companion HD153919

The first high resolution non-dispersive 2-60 KeV X-ray spectra of 4U1700-37 is presented. The continuum is typical of that found from X-ray pulsars; that is a flat power law between 2 and 10 keV and, beyond 10 keV, an exponential decay of characteristic energy varying between 10 and 20 keV. No X-ray pulsations were detected between 160 ms and 6 min with an amplitude greater than approximately 2%. The absorption measured at binary phases approximately 0.72 is comparable to that expected from the stellar wind of the primary. The gravitational capture of material in the wind is found to be more than enough to power the X-ray source. The increase in the average absorption after phi o approximately 0.5 is confirmed. The minimum level of adsorption is a factor of 2 or 3 lower than that reported by previous observers, which may be related to a factor of approximately 10 decline in the average X-ray luminosity over the same interval. Short term approximately 50% variations in adsorption are seen for the first time which appear to be loosely correlated with approximately 10 min flickering activity in the X-ray flux. These most likely originate from inhomogeneities in the stellar wind of the primary.

White, N. E.↗

The X-ray absorption spectrum of 4U 1700-37 and its implications for the stellar wind of the companion HD 153919

The first high resolution non-dispersive 2-60 keV X-ray spectra at 4U1700-37 is presented. The continuum is typical of that found from X-ray pulsars; that is a flat powr law between 2 and 10 keV and, beyond 10 keV, an exponential decay of characteristic energy varying between 10 and 20 keV. No X-ray pulsations were detected between 160 ms and 6 min with an amplitude greater than approximately 2 percent. The absorption measured at binary phases approximately 0.72 is comparable to that expected from the stellar wind of the primary. The gravitational capture of material in the wind is found to be more than enough to power the X-ray source. The increase in the average absorption after phi of approximately 0.5 is confirmed. The minimum level of adsorption is a factor of 2 or 3 lower than that reported by previous observers, which may be related to a factor of approximately 10 decline in the average X-ray luminosity over the same interval. Short term approximately 50 percent variations in adsorption are seen for the first time which appear to be loosely correlated with approximately 10 min flickering activity in the X-ray flux. These most likely originate from inhomogeneities in the stellar wind of the primary. Previously announced in STAR as N83-14034

White, N. E.↗

STATISTICAL STUDY OF CORONAL MASS EJECTIONS WITH AND WITHOUT DISTINCT LOW CORONAL SIGNATURES

Taking advantage of the two viewpoints of the STEREO spacecraft, we present a statistical study of coronal mass ejections (CMEs) with and without distinct low coronal signatures (LCSs) from 2009 January 1 to August 31. During this period, the lines of sight from STEREO A and B are almost perpendicular and nearly a quarter of the Sun was observed by both. We identified 34 CMEs that originated from around this area and find that (1) about 1 out of 3 CMEs that were studied during 8 months of solar minimum activity are stealth CMEs; a CME is stealth if no distinct LCS (such as coronal dimming, coronal wave, filament eruption, flare, post-eruptive arcade) can be found on the disk. (2) The speeds of the stealth CMEs without LCSs are typically below 300 km s{sup -1}. Comparing with the slow CMEs with LCSs, the stealth CMEs did not show any clear differences in their velocity and acceleration evolution. (3) The source regions of the stealth CMEs are usually located in the quiet Sun rather than active regions. Detailed study indicates that more than half of the stealth CMEs in this paper showed some faint change of the coronal structures (likely parts of flux ropes) when they could be observed over the solar limb before or during the CME evolution. Finally, we note that space weather detection systems based on LCSs totally independent of coronagraph data may fail to detect a significant proportion of CMEs.

79 ASTRONOMY AND ASTROPHYSICS↗

RFI Risk Reduction Activities Using New Goddard Digital Radiometry Capabilities

The Goddard Radio-Frequency Explorer (GREX) is the latest fast-sampling radiometer digital back-end processor that will be used for radiometry and radio-frequency interference (RFI) surveying at Goddard Space Flight Center. The system is compact and deployable, with a mass of about 40 kilograms. It is intended to be flown on aircraft. GREX is compatible with almost any aircraft, including P-3, twin otter, C-23, C-130, G3, and G5 types. At a minimum, the system can function as a clone of the Soil Moisture Active Passive (SMAP) ground-based development unit [1], or can be a completely independent system that is interfaced to any radiometer, provided that frequency shifting to GREX's intermediate frequency is performed prior to sampling. If the radiometer RF is less than 200MHz, then the band can be sampled and acquired directly by the system. A key feature of GREX is its ability to simultaneously sample two polarization channels simultaneously at up to 400MSPS, 14-bit resolution each. The sampled signals can be recorded continuously to a 23 TB solid-state RAID storage array. Data captures can be analyzed offline using the supercomputing facilities at Goddard Space Flight Center. In addition, various Field Programmable Gate Array (FPGA) - amenable radiometer signal processing and RFI detection algorithms can be implemented directly on the GREX system because it includes a high-capacity Xilinx Virtex-5 FPGA prototyping system that is user customizable.

Bradley, Damon↗

TENTATIVE EVIDENCE FOR RELATIVISTIC ELECTRONS GENERATED BY THE JET OF THE YOUNG SUN-LIKE STAR DG Tau

Synchrotron emission has recently been detected in the jet of a massive protostar, providing further evidence that certain jet formation characteristics for young stars are similar to those found for highly relativistic jets from active galactic nuclei. We present data at 325 and 610 MHz taken with the Giant Metrewave Radio Telescope of the young, low-mass star DG Tau, an analog of the Sun soon after its birth. This is the first investigation of a low-mass young stellar object at such low frequencies. We detect emission with a synchrotron spectral index in the proximity of the DG Tau jet and interpret this emission as a prominent bow shock associated with this outflow. This result provides tentative evidence for the acceleration of particles to relativistic energies due to the shock impact of this otherwise very low-power jet against the ambient medium. We calculate the equipartition magnetic field strength B {sub min} ≈ 0.11 mG and particle energy E {sub min} ≈ 4 × 10{sup 40} erg, which are the minimum requirements to account for the synchrotron emission of the DG Tau bow shock. These results suggest the possibility of low energy cosmic rays being generated by young Sun-like stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Earthquake Arrival Association with Backprojection and Graph Theory

The association of seismic-wave arrivals with causative earthquakes becomes progressively more challenging as arrival detection methods become more sensitive, and particularly when earthquake rates are high. For instance, seismic waves arriving across a monitoring network from several sources may overlap in time, false arrivals may be detected, and some arrivals may be of unknown phase (e.g., P or S waves). We propose an automated method to associate arrivals with earthquake sources and obtain source locations applicable to such situations. To do so, we use a pattern detection metric based on the principle of back-projection to reveal candidate sources followed by graph-theory-based clustering and an integer linear optimization routine to associate arrivals with the minimum number of sources necessary to explain the data. We find that this method solves for all sources and phase assignments simultaneously, rather than in a sequential greedy procedure as is common in other association routines. We demonstrate our method on both synthetic and real data from the Integrated Plate Boundary Observatory Chile seismic network of northern Chile. For the synthetic tests, we report results for cases with varying complexity, including rates of 500 earthquakes/day and 500 false arrivals/station/day, for which we measure true positive detection accuracy of >95%. For the real data, we develop a new catalog between 1 January 2010 and 31 December 2017 containing 817,548 earthquakes, with detection rates on average 279 earthquakes/day and a magnitude-of-completion of M~1.8. A subset of detections are identified as sources related to quarry and industrial site activity, and we also detect thousands of foreshocks and aftershocks of the 1 April 2014 Mw 8.2 Iquique earthquake. During the highest rate of aftershock activity, >600 earthquakes/day are detected in the vicinity of the Iquique earthquake rupture zone.

58 GEOSCIENCES↗

A novel approach to criticality accident detection for a legacy facility

For operations on the Sellafield site involving fissile material a Criticality Accident Alarm System (CAAS) has traditionally been installed unless an omission case can be made. An omission case would examine if, in the absence of all controls, a criticality could reasonably be expected or whether the potential dose to an operator would remain below a maximum acceptable dose. It is a UK legal requirement for adequate emergency arrangements to be in place for hazards on a nuclear licensed site. For facilities where criticality is credible there is a regulatory expectation that a -Criticality Warning System- should be in place. A -Criticality Warning System- is not necessarily a full CAAS and alternative means of criticality detection may be part of an adequate emergency plan. The Sellafield site has a Magnox fuel reprocessing facility which has been operated since the 1960's. Evaporation of the Medium Active (MA) liquid waste from this process is undertaken in an associated building. Following extensive review of the plant and process a number of maloperations which can route fissile material to the MA evaporator were identified. Adequate controls to prevent these scenarios were shown to be in place. In the unlikely event of a failure of controls leading to sustained loss of fissile material a criticality incident may occur and hence an emergency plan was determined to be necessary. The novel emergency arrangements which were developed utilized the existing gamma monitor network located across multiple building floors. These gamma monitors are present for radiological safety. This emergency arrangement would require rapid interpretation of the gamma alarms by an operator and the manual triggering of a criticality evacuation alarm. The gamma monitors were demonstrated to be able to detect the minimum incident of concern (10{sup 15} fissions) as well as being able to alarm during the ramp up in power of a large criticality incident (10{sup 18} fissions). It was shown that a criticality accident could readily be distinguished from a radiological event (e.g. loss of containment). To support this work, criticality excursion analysis was used to examine the likely characteristics of a criticality in the MA evaporator. This novel arrangement was justified due to a number of factors including: the limited remaining operational lifetime of this facility (<5 years), the low frequency of maloperation coupled with a failure of controls and the crucial risk reduction provided by the continued reprocessing of Magnox fuel. Furthermore, the time and cost involved with design and installation of a standard CAAS would be substantially greater than a plan based upon existing instrumentation. These arguments were accepted by the UK regulator the Office for Nuclear Regulation (ONR). (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Survey of Technologies to Meet PAG limits for Detection of Cesium-137 in Water

The goal of this report is to evaluate the process of adding a sorbent to the sampling process to preconcentrate Cs-137 and then analyze the sorbent to provide a rapid assessment of results to guide decisions on drinking water sources and the protection of the public. Multiple unit design variables were considered: sample configuration/geometry, sorbent efficiency, sample volume. Model simulations demonstrated through these unit design efficiencies that 10 L of sample volume processed through a sorbent provides nearly two orders of magnitude improvement in sample counting time to provide results to a decision maker than the current process. Over 60 publications and reports concerning Cs-137 and sorbents were evaluated. The key attributes were readiness of sorbent to be deployed in a mobile laboratory environment, and minimum sample preparation and conditioning. Examples of sorbents not considered further included nanomaterials, which have not been evaluated at a commercial scale and are limited in availability. The recommended sorbents for further consideration include: ferrocyanide salts, zeolite, and chemically modified granular activated carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗