A comparison of point defects in Cd 1-x Zn x Te 1-y Se y crystals grown by Bridgman and traveling heater methods
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Building air leaks (both through exterior and interior surfaces) can have a significant impact on energy consumption, indoor air quality, fire safety, and moisture accumulation affecting structural durability. Blower door testing has been used to measure leaks in buildings, but commonly used testing methods do not directly measure interior leaks. In this paper, new testing methods (guarded interior test and zonal multipoint pressure testing method) are presented that directly measure these interior leaks, utilizing common blower door equipment for both single and multi-point testing. Furthermore, these new methods are compared to conventional methods in terms of the information provided, limitations and time/effort needed. In addition, building leak measurement results are analyzed to reveal a) coupling between power law model values (exponent and coefficient) for an ensemble of buildings, b) the error in using single point testing when estimating low pressure leakage, and c) how building power law models vary from low to high pressure ranges.
The measurement of large-scale anisotropies in cosmic ray arrival directions at energies above 10{sup 13} eV is performed through the detection of extensive air showers (EAS) produced by cosmic ray interactions in the atmosphere. The observed anisotropies are small, so accurate measurements require small statistical uncertainties, i.e., large data sets. These can be obtained by employing ground detector arrays with large extensions (from 10{sup 4} to 10{sup 9} m{sup 2}) and long operation time (up to 20 years). The control of such arrays is challenging and spurious variations in the counting rate due to instrumental effects (e.g., data taking interruptions or changes in the acceptance) and atmospheric effects (e.g., air temperature and pressure effects on EAS development) are usually present. These modulations must be corrected very precisely before performing standard anisotropy analyses, i.e., harmonic analysis of the counting rate versus local sidereal time. In this paper we discuss an alternative method to measure large-scale anisotropies, the 'East-West method'. It was originally proposed in the 1940s to study asymmetries in the flux of solar cosmic rays and later applied by Nagashima et al. to EAS at higher energies. It is a differential method, as it is based on the analysis of the difference of the counting rates in the east and west directions. Besides explaining the principle, we present here its mathematical derivation, showing that the method is largely independent of experimental effects, that is, it does not require corrections for acceptance and/or for atmospheric effects. We explain the use of the method to derive the amplitude and phase of the anisotropy and demonstrate its power under different conditions of detector operation.
Linear numerical inversion methods applied to atmospheric remote sounding generally can be categorized in two ways: (1) iterative, and (2) inverse matrix methods. However, these two categories are not unrelated; a duality exists between them. In other words, given an iterative scheme, a corresponding inverse matrix method exists, and conversely. This duality concept is developed for the more familiar linear methods. The iterative duals are compared with the classical linear iterative approaches and their differences analyzed. The importance of the initial profile in all methods is stressed. Calculations using simulated data are made to compare accuracies and to examine the dependence of the solution on the initial profile.
A finite element method is derived for studying the transmission of sound in nonuniform ducts without flow. The method is based on a weighted residuals technique and eight noded isoparametric elements. The method employs two computational schemes: the Helmholtz equation found through conservation equations, and the conservation equations themselves. Solutions are found for transmission and reflection coefficients for both two-dimensional and circular geometries. Numerical solutions are compared with those for a method of weighted residuals in the form of a modified Galerkin method, showing good agreement.
This paper presents a comparison between two numerical methods for the extrapolation of nonlinear force-free magnetic fields, viz the Iterative Method (IM) and the Progressive Extension Method (PEM). The advantages and disadvantages of these two methods are summarized, and the accuracy and numerical instability are discussed. On the basis of this investigation, it is claimed that the two methods do resemble each other qualitatively.
Diastolic dysfunction is an important cause of congestive heart failure; however, the basic mechanisms causing diastolic congestive heart failure are not fully understood, especially the role of the cardiac muscle cell, or cardiocyte, in this process. Before the role of the cardiocyte in this pathophysiology can be defined, methods for measuring cardiocyte constitutive properties must be developed and validated. Thus this study was designed to evaluate a new method to characterize cardiocyte constitutive properties, the gel stretch method. Cardiocytes were isolated enzymatically from normal feline hearts and embedded in a 2% agarose gel containing HEPES-Krebs buffer and laminin. This gel was cast in a shape that allowed it to be placed in a stretching device. The ends of the gel were held between a movable roller and fixed plates that acted as mandibles. Distance between the right and left mandibles was increased using a stepper motor system. The force applied to the gel was measured by a force transducer. The resultant cardiocyte strain was determined by imaging the cells with a microscope, capturing the images with a CCD camera, and measuring cardiocyte and sarcomere length changes. Cardiocyte stress was characterized with a finite-element method. These measurements of cardiocyte stress and strain were used to determine cardiocyte stiffness. Two variables affecting cardiocyte stiffness were measured, the passive elastic spring and viscous damping. The passive spring was assessed by increasing the force on the gel at 1 g/min, modeling the resultant stress vs. strain relationship as an exponential [sigma = A/k(ekepsilon - 1)]. In normal cardiocytes, A = 23.0 kN/m2 and k = 16. Viscous damping was assessed by examining the loop area between the stress vs. strain relationship during 1 g/min increases and decreases in force. Normal cardiocytes had a finite loop area = 1.39 kN/m2, indicating the presence of viscous damping. Thus the gel stretch method provided accurate measurements of cardiocyte constitutive properties. These measurements have allowed the first quantitative assessment of passive elastic spring properties and viscous damping in normal mammalian cardiocytes.
We propose a simplication of the face-averaged nodal-gradient (FANG) method for a cell-centered finite-volume Euler/Navier-Stokes solver on arbitrary grids, and compare it with other gradient methods for trouble-prone grids in two dimensions. The implementation of the FANG method is simplified by adding the face-neighbor cells of the cells around a node to a least-squares gradient stencil. The resulting method is stable for both triangular and quadrilateral grids. Although it increases the residual stencil for triangular grids, it allows the solver to work seamlessly for mixed grids and greatly simplifies the implementation, especially in three dimensions. For comparison, only explicit weighted/unweighted least-squares cell-centered and nodal gradient methods are considered. These gradients are used in both inviscid and viscous schemes, and we investigate their impact on the iterative convergence of an implicit defect-correction solver on difficult grids such as highly-curved-and-thin grids and highly distorted anisotropic grids. Finally, we will also consider a face-stencil-based limiter and compare it with a conventional cell-stencil-based limiter.
A local incident flux response expansion transport method is developed to generate transport solutions for coupling to diffusion theory codes regardless of their solution method (e.g., fine mesh, nodal, response based, finite element, etc.) for reactor core calculations in both two-dimensional (2-D) and three-dimensional (3-D) cylindrical geometries. In this approach, a Monte Carlo method is first used to precompute the local transport solution (i.e., response function library) for each unique transport coarse node, in which diffusion theory is not valid due to strong transport effects. The response function library is then used to iteratively determine the albedo coefficients on the diffusion-transport interfaces, which are then used as the coupling parameters within the diffusion code. This interface coupling technique allows a seamless integration of the transport and diffusion methods. The new method retains the detailed heterogeneity of the transport nodes and naturally constructs any local solution within them by a simple superposition of local responses to all incoming fluxes from the contiguous coarse nodes. A new technique is also developed for coupling to fine-mesh diffusion methods/codes. The local transport method/module is tested in 2-D and 3-D pebble-bed reactor benchmark problems consisting of an inner reflector, an annular fuel region, and a controlled outer reflector. It is found that the results predicted by the transport module agree very well with the reference fluxes calculated directly by MCNP in both benchmark problems.
Heat exchanger assemblies and methods for providing heat exchange as well as methods providing specific energy to predetermined materials within an assembly as well as gas turbine engines as well as methods of powering same are provided. Heating assemblies are provided that can include: a heat-sinking substrate; and a selective emitter layer in thermal communication with the substrate. These assemblies can be provided as part of heat exchanger assemblies. Methods for providing heat to a fluid are also provided that can include heating a layer upon a substrate to provide photons of a predetermined wavelength to a fluid from the layer.Turbine combustion engines are also provided that can include a turbine having at least a portion of the blades in the hot section of the turbine coated with an emissivity layer in thermal communication with the turbine blade. Methods for powering turbine combustion engines are also provided.
The structure of the alkali silicate gel (ASR) collected from the galleries of Furnas Dam in Brazil was determined by a pair distribution function (PDF) analysis of high energy X-ray diffraction data. Since this method is relatively new to concrete structure analysis a detailed introduction on the PDF method is given for glassy SiO{sub 2}. The bulk amorphous structure of the dam material is confirmed as no Bragg peaks are observed in the scattered intensity. The real space results show that the local structure of the amorphous material is similar to kanemite (KHSi{sub 2}O{sub 5}:3H{sub 2}O) however the long range layer structure of the crystal is broken up in the amorphous state, so that ordering only persists of the length scale of a few polyhedra. The silicate layer structure is a much more disordered than predicted by molecular dynamics models. The X-ray results are consistent with the molecular dynamics model of Kirkpatrick et al. (2005) [1] which predicts that most of the water resides in pores within the amorphous network rather than in layers. The total scattering data provide a rigorous basis against which other models may also be tested.
For over 40 years, the Implicit Monte Carlo (IMC) method has been used to solve challenging problems in thermal radiative transfer. These problems typically contain regions that are optically thick and diffusive, as a consequence of the high degree of “pseudo-scattering” introduced to model the absorption and reemission of photons from a tightly-coupled, radiating material. IMC has several well-known features that could be improved: a) it can be prohibitively computationally expensive, b) it introduces statistical noise into the material and radiation temperatures, which may be problematic in multiphysics simulations, and c) under certain conditions, solutions can be nonphysical, in that they violate a maximum principle, where IMC-calculated temperatures can be greater than the maximum temperature used to drive the problem. We have developed a variant of IMC called iterative thermal emission IMC, which is designed to have a reduced parameter space in which the maximum principle is violated. ITE IMC is a more implicit version of IMC in that it uses the information obtained from a series of IMC photon histories to improve the estimate for the end of time step material temperature during a time step. A better estimate of the end of time step material temperature allows for a more implicit estimate of other temperature-dependent quantities: opacity, heat capacity, Fleck factor (probability that a photon absorbed during a time step is not reemitted) and the Planckian emission source. We have verified the ITE IMC method against 0-D and 1-D analytic solutions and problems from the literature. These results are compared with traditional IMC. We perform an infinite medium stability analysis of ITE IMC and show that it is slightly more numerically stable than traditional IMC. We find that significantly larger time steps can be used with ITE IMC without violating the maximum principle, especially in problems with non-linear material properties. The ITE IMC method does however yield solutions with larger variance because each sub-step uses a different Fleck factor (even at equilibrium)
Not Available
In this paper a new approach combining the features of the homotopy concept with variational approach is proposed to find accurate analytical solutions for nonlinear oscillators with and without a fractional power restoring force. Since the first-order approximation leads to very accurate results, comparisons with other results are presented to show the effectiveness of this method. The validity of the method is independent of whether or not there exist small or large parameters in the considered nonlinear equations; the obtained results prove the validity and efficiency of the method, which can be easily extended to other strongly nonlinear problems. At the end we compare our procedure with the optimal homotopy perturbation method.
We present the umbrella sampling (US) technique and show that it can be used to sample extremely low-probability areas of the posterior distribution that may be required in statistical analyses of data. In this approach sampling of the target likelihood is split into sampling of multiple biased likelihoods confined within individual umbrella windows. We show that the US algorithm is efficient and highly parallel and that it can be easily used with other existing Markov Chain Monte Carlo (MCMC) samplers. The method allows the user to capitalize on their intuition and define umbrella windows and increase sampling accuracy along specific directions in the parameter space. Alternatively, one can define umbrella windows using an approach similar to parallel tempering. We provide a public code that implements US as a standalone PYTHON package. We present a number of tests illustrating the power of the US method in sampling low-probability areas of the posterior and show that this ability allows a considerably more robust sampling of multimodal distributions compared to standard sampling methods. We also present an application of the method in a real world example of deriving cosmological constraints using the supernova type Ia data. We show that US can sample the posterior accurately down to the approximate to 15 sigma credible region in the Omega(m) - Omega(Lambda) plane, while for the same computational effort the affine-invariant MCMC sampling implemented in the emcee code samples the posterior reliably only to approximate to 3 sigma.
Purpose: New technology has been developed to treat age-related macular degeneration (AMD) using 100 kVp pencil-beams that enter the patient through the radio-resistant sclera with a depth of interest between 1.6 and 2.6 cm. Measurement of reference and relative dose in a kilovoltage x-ray beam with a 0.42 cm diameter field size and a 15 cm source to axis distance (SAD) is a challenge that is not fully addressed in current guidelines to medical physicists. AAPM's TG-61 gives dosimetry recommendations for low and medium energy x-rays, but not all of them are feasible to follow for this modality. Methods: An investigation was conducted to select appropriate equipment for the application. PTW's Type 34013 Soft X-Ray Chamber (Freiburg, Germany) and CIRS's Plastic Water LR (Norfolk, VA) were found to be the best available options. Attenuation curves were measured with minimal scatter contribution and thus called Low Scatter Tissue Air Ratio (LSTAR). A scatter conversion coefficient (C{sub scat}) was derived through Monte Carlo radiation transport simulation using MCNPX (LANL, Los Alamos, NM) to quantify the difference between a traditional TAR curve and the LSTAR curve. A material conversion coefficient (C{sub mat}) was determined through experimentation to evaluate the difference in attenuation properties between water and Plastic Water LR. Validity of performing direct dosimetry measurements with a source to detector distance other than the treatment distance, and therefore a different field size due to a fixed collimator, was explored. A method—Integrated Tissue Air Ratio (ITAR)—has been developed that isolates each of the three main radiological effects (distance from source, attenuation, and scatter) during measurement, and integrates them to determine the dose rate to the macula during treatment. Results: LSTAR curves were determined to be field size independent within the range explored, indicating that direct dosimetry measurements may be performed with a source to detector distance of 20 cm even though the SAD is 15 cm during treatment. C{sub scat} varied from 1.102 to 1.106 within the range of depths of interest. The experimental variance among repeated measurements of C{sub mat} was larger than depth dependence, so C{sub mat} was estimated as1.019 for all depths of interest. Conclusions: Equipment selection, measurement techniques, and formalism for the determination of dose rate to the macula during stereotaxy for AMD have been determined and are strongly recommended by the authors of this paper to be used by clinical medical physicists.
We develop and analyze a new family of virtual element methods on unstructured polygonal meshes for the diffusion problem in primal form, that use arbitrarily regular discrete spaces V h $\subset$ C α } ϵ $\mathbb{N}$. The degrees of freedom are (a) solution and derivative values of various degree at suitable nodes and (b) solution moments inside polygons. The convergence of the method is proven theoretically and an optimal error estimate is derived. The connection with the Mimetic Finite Difference method is also discussed. Numerical experiments confirm the convergence rate that is expected from the theory.
Evaporation represents a principal form of water loss from water bodies, but quantifying evaporation with transpiring vegetation is challenging, owing to the difficulties in disentangling evaporation from transpiration. As the two processes have different effects on water isotope signatures (i.e., oxygen and hydrogen stable isotope ratios expressed by δ 18 O and δ 2 H), we used both the δ 18 O and δ 2 H values of water samples to calculate their deuterium excess (d) values, which are proportionate to fraction of evaporation loss (E f ) of water being sampled. Comparing with a single isotope method, the d method holds the advantage that it does not require knowledge of the initial isotope ratios of source water. Limitations of the d method, for example, effects of prior-evaporation of water before entering water bodies, can be checked and corrected. The sampling locations throughout our study site differed in vegetation coverage, water depth, and distance to water inflow (or discharge gate of water inflow), which are three important factors in water management. This sampling design offered us a unique opportunity to quantify the influences of the above three factors on E f . We found the following: (1) There was a spatiotemporal pattern in δ 18 O distribution. (2) The E f was negatively related to the vegetation coverage, positively related to distance to the water source inflow but nonsignificantly related to water depth. Therefore, vegetation and distance to the water inflow are two important considerations for the control of evaporative water loss, and evaporation calculated by the d method can lead to more informed water management.