GEANT4 simulations of cosmic muon background in CEMRC BEGe lung detectors and detection sensitivity optimization of trans-uranic radionuclides
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
The study of low dose and low-dose rate exposure is of central importance in understanding the possible range of health effects from prolonged exposures to radiation. The One Million Person Study of Radiation Workers and Veterans (MPS) of low-dose health effects was designed to evaluate radiation risks among healthy American workers and veterans. The MPS is evaluating low-dose and dose-rate effects, intakes of radioactive elements, cancer and non-cancer outcomes, as well as differences in risks between women and men. Medical radiation workers make up a large group of individuals occupationally exposed to low doses of radiation from external x-ray/gamma exposures. For the MPS, about 100 000 United States medical radiation workers have been selected for study. The approach to the complex dosimetry circumstances for such workers over three to four decades of occupation were initially and broadly described in National Council on Radiation Protection and Measurements (NCRP) Report No. 178. NCRP Commentary No. 30 provides more detail and describes an optimum approach for using personal monitoring data to estimate lung and other organ doses applicable to the cohort and provides specific precautions/considerations applicable to the dosimetry of medical radiation worker organ doses for use in epidemiologic studies. The use of protective aprons creates dosimetric complexity. It is recommended that dose values from dosimeters worn over a protective apron be reduced by a factor of 20 for estimating mean organ doses to tissues located in the torso and that 15% of the marrow should be assumed to remain unshielded for exposure scenarios when aprons are worn. Conversion coefficients relating personal dose equivalent, H p (10) in mSv, to mean absorbed doses to organs and tissues, D T in mGy, for females and males for six exposure scenarios have been determined and presented for use in the MPS. This Memorandum summarises several key points in NCRP Commentary No. 30.
Contaminated wounds are a common route of internal deposition of radionuclides for nuclear and radiation workers. They may result in significant doses to radiosensitive organs and tissues in an exposed individual's body. The United States Transuranium and Uranium Registries' whole-body donor (Case 0303) accidentally punctured his finger on equipment contaminated with plutonium nitrate. The wound was surgically excised and medically treated with intravenous injections of Ca-DTPA. A total of 16 g Ca-DTPA was administered in 18 treatments during the 2 months following the accident. Ninety-three urine samples were collected and analysed over 14 years following the accident. An estimated 239 Pu activity of 73.7 Bq was excreted during Ca-DTPA treatment. Post-mortem radiochemical analysis of autopsy tissues indicated that 40 years post-accident 21.6 ± 0.2 Bq of 239 Pu was retained in the skeleton, 12.2 ± 0.3 Bq in the liver, and 3.7 ± 0.1 Bq in other soft tissues; 1.35 ± 0.02 Bq of 239 Pu was measured in tissue samples from the wound site. To estimate the plutonium intake, late urine measurements, which were unaffected by chelation, and post-mortem radiochemical analysis results were evaluated using the IMBA Professional Plus software. The application of the National Council on Radiation Protection and Measurements wound model with an assumption of intake material as a predominantly strongly retained soluble plutonium compound with a small insoluble fraction adequately described the data (p = 0.46). The effective intake was estimated to be 50.2 Bq of plutonium nitrate and 1.5 Bq of the fragment. Here, the prompt medical intervention with contaminated tissue excision and subsequent Ca-DTPA decorporation therapy reduced 239 Pu activity available for uptake and long-term retention in this individual's systemic organs by a factor of 38.
Cells exposed to ionizing radiation have a wide spectrum of DNA lesions that include DNA single-strand breaks, DNA double-strand breaks (DSBs), oxidative base damage and DNA-protein crosslinks. Among them, DSB is the most critical lesion, which when mis-repaired leads to unstable and stable chromosome aberrations. Currently, chromosome aberration analysis is the preferred method for biological monitoring of radiation-exposed humans. Here, stable chromosome aberrations, such as inversions and balanced translocations, persist in the peripheral blood lymphocytes of radiation-exposed humans for several years and, therefore, are potentially useful tools to prognosticate the health risks of radiation exposure, particularly in the hematopoietic system. In this review, we summarize the cytogenetic follow-up studies performed by REAC/TS (Radiation Emergency Assistance Center/Training site, Oak Ridge, USA) on humans exposed to internal and external radiation. In the light of our observations as well as the data existing in the literature, this review attempts to highlight the importance of follow-up studies for predicting the extent of genomic instability and its impact on delayed health risks in radiation-exposed victims.
Abstract Tennessee Eastman Corporation workers were exposed to uranium dust resulting in high-linear energy transfer (LET) irradiation to lung tissue. In this work, radiation lung doses were reconstructed for 26 650 men and women working at the plant between 1942 and 1947. Site air monitoring data of uranium concentrations and payroll records were used to determine the daily inhaled activities and annualized lung doses. Variations in the activity median aerodynamic diameter of the uranium dust, the solubility of particulate matter in the lungs and the sex-specific breathing rate were investigated as part of a sensitivity analysis. Male and female mean lung doses of 18.9 and 32.7 mGy, respectively, from high-LET alpha irradiation, and there was general agreement with evaluations from previously published epidemiological studies. Annual lung dose estimates and sensitivity analysis for the 26 650 workers in the TEC cohort have been archived on the United States Department of Energy Comprehensive Epidemiologic Data Resource.
Abstract In biokinetic modeling systems employed for radiation protection, biological retention and excretion have been modeled as a series of discretized compartments representing the organs and tissues of the human body. Fractional retention and excretion in these organ and tissue systems have been mathematically governed by a series of coupled first-order ordinary differential equations (ODEs). The coupled ODE systems comprising the biokinetic models are usually stiff due to the severe difference between rapid and slow transfers between compartments. In this study, the capabilities of solving a complex coupled system of ODEs for biokinetic modeling were evaluated by comparing different Python programming language solvers and solving methods with the motivation of establishing a framework that enables multi-level analysis. The stability of the solvers was analyzed to select the best performers for solving the biokinetic problems. A Python-based linear algebraic method was also explored to examine how the numerical methods deviated from an analytical or semi-analytical method. Results demonstrated that customized implicit methods resulted in an enhanced stable solution for the inhaled 60 Co (Type M) and 131 I (Type F) exposure scenarios for the inhalation pathway of the International Commission on Radiological Protection (ICRP) Publication 130 Human Respiratory Tract Model (HRTM). The customized implementation of the Python-based implicit solvers resulted in approximately consistent solutions with the Python-based matrix exponential method ( expm ). The differences generally observed between the implicit solvers and expm are attributable to numerical precision and the order of numerical approximation of the numerical solvers. This study provides the first analysis of a list of Python ODE solvers and methods by comparing their usage for solving biokinetic models using the ICRP Publication 130 HRTM and provides a framework for the selection of the most appropriate ODE solvers and methods in Python language to implement for modeling the distribution of internal radioactivity.
Abstract Emerging magnetic resonance (MR) guided radiotherapy affords significantly improved anatomy visualization and, subsequently, more effective personalized treatment. The new therapy paradigm imposes significant demands on radiation dose calculation quality and speed, creating an unmet need for the acceleration of Monte Carlo (MC) dose calculation. Existing deep learning approaches to denoise the final plan MC dose fail to achieve the accuracy and speed requirements of large-scale beamlet dose calculation in the presence of a strong magnetic field for online adaptive radiotherapy planning. Our deep learning dose calculation method, DeepMC, addresses these needs by predicting low-noise dose from extremely noisy (but fast) MC-simulated dose and anatomical inputs, thus enabling significant acceleration. DeepMC simultaneously reduces MC sampling noise and predicts corrupted dose buildup at tissue-air material interfaces resulting from MR-field induced electron return effects. Here we demonstrate our model’s ability to accelerate dose calculation for daily treatment planning by a factor of 38 over traditional low-noise MC simulation with clinically meaningful accuracy in deliverable dose and treatment delivery parameters. As a post-processing approach, DeepMC provides compounded acceleration of large-scale dose calculation when used alongside established MC acceleration techniques in variance reduction and graphics processing unit-based MC simulation.
State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.
Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.
Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.
Objective. Our objective is to formulate the problem of the magnetoencephalographic (MEG) sensor array design as a well-posed engineering problem of accurately measuring the neuronal magnetic fields. This is in contrast to the traditional approach that formulates the sensor array design problem in terms of neurobiological interpretability the sensor array measurements. Approach. We use the vector spherical harmonics (VSH) formalism to define a figure-of-merit for an MEG sensor array. We start with an observation that, under certain reasonable assumptions, any array of m perfectly noiseless sensors will attain exactly the same performance, regardless of the sensors' locations and orientations (with the exception of a negligible set of singularly bad sensor configurations). We proceed to the conclusion that under the aforementioned assumptions, the only difference between different array configurations is the effect of (sensor) noise on their performance. We then propose a figure-of-merit that quantifies, with a single number, how much the sensor array in question amplifies the sensor noise. Main results. We derive a formula for intuitively meaningful, yet mathematically rigorous figure-of-merit that summarizes how desirable a particular sensor array design is. We demonstrate that this figure-of-merit is well-behaved enough to be used as a cost function for a general-purpose nonlinear optimization methods such as simulated annealing. We also show that sensor array configurations obtained by such optimizations exhibit properties that are typically expected of 'high-quality' MEG sensor arrays, e.g. high channel information capacity. Significance. Our work paves the way toward designing better MEG sensor arrays by isolating the engineering problem of measuring the neuromagnetic fields out of the bigger problem of studying brain function through neuromagnetic measurements.
Abstract Objective . To propose a mathematical model for applying ionization detail (ID), the detailed spatial distribution of ionization along a particle track, to proton and ion beam radiotherapy treatment planning (RTP). Approach . Our model provides for selection of preferred ID parameters ( I p ) for RTP, that associate closest to biological effects. Cluster dose is proposed to bridge the large gap between nanoscopic I p and macroscopic RTP. Selection of I p is demonstrated using published cell survival measurements for protons through argon, comparing results for nineteen I p : N k , k = 2, 3, …, 10, the number of ionizations in clusters of k or more per particle, and F k , k = 1, 2, …, 10, the number of clusters of k or more per particle. We then describe application of the model to ID-based RTP and propose a path to clinical translation. Main results . The preferred I p were N 4 and F 5 for aerobic cells, N 5 and F 7 for hypoxic cells. Significant differences were found in cell survival for beams having the same LET or the preferred N k . Conversely, there was no significant difference for F 5 for aerobic cells and F 7 for hypoxic cells, regardless of ion beam atomic number or energy. Further, cells irradiated with the same cluster dose for these I p had the same cell survival. Based on these preliminary results and other compelling results in nanodosimetry, it is reasonable to assert that I p exist that are more closely associated with biological effects than current LET-based approaches and microdosimetric RBE-based models used in particle RTP. However, more biological variables such as cell line and cycle phase, as well as ion beam pulse structure and rate still need investigation. Significance . Our model provides a practical means to select preferred I p from radiobiological data, and to convert I p to the macroscopic cluster dose for particle RTP.
Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.
Not provided.
Abstract Although mammalian fetuses have been suggested to be sensitive to radiation, an increased frequency of translocations was not observed in blood lymphocytes from atomic bomb (A-bomb) survivors who were exposed to the bomb in utero and examined as adults. Since experiments using hematopoietic cells of mice and rats confirmed this finding, it was hypothesized that either irradiated fetal hematopoietic stem cells (f-HSCs) cannot generate exchange-type chromosomal aberrations or cells bearing induced aberrations are eliminated before the animals reach adulthood. In the present study, pregnant mice (12.5–15.5 days post coitum [dpc]) were irradiated with 2 Gy of X-rays and long-term HSCs (LT-HSCs) were isolated 24 h later. Multicolor fluorescence in situ hybridization (mFISH) analysis of LT-HSC clones proliferated in vitro showed that nine out of 43 (21%) clones from fetuses and 21 out of 41 (51%) clones from mothers bore translocations. These results indicate that cells with translocations can arise in mouse f-HSCs but exist at a lower frequency than in the mothers 24 h after X-ray exposure. Thus, it seems likely that translocation-bearing f-HSCs are generated but subsequently disappear, so that the frequency of lymphocyte translocations may decrease and reach the control level by the time the animals reach adulthood.
Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.
Chelation therapy is sometimes used after potential exposures to plutonium to increase urinary excretion of the radionuclide to improve the accuracy of bioassay measurements. The purpose of this report is to describe the enhancement of urinary excretion of plutonium during and after the administration of the trisodium salt of calcium diethylenetriaminepentaacetate (Ca-DTPA) daily for 3 d to a group of male and female plutonium workers from the Mayak Production Association in Ozyorsk, Russia. One-hundred and two cases (18 females and 84 males) were selected where urinary contents of plutonium, prior to chelation, exceeded the detection threshold. Daily urine collections were obtained during the 3 d of Ca-DTPA treatments. In addition, 58 of these cases had urine bioassays at 1–45 d after chelation. The daily enhancement over baseline values excretion of plutonium was found to be 50.4×/1.4 (geometric mean and geometric standard deviation); 58.9×/1.2; 72.9×/1.4 in the first, second and third days of Ca-DTPA administration. The mean enhancement for the 3-d period was 60.1×/1.7. The rate of plutonium excretion from 1 to 45 d after chelation decreased with a half-period of 3.9 d and the chelation enhancement factor (Кenh-i) is described by the function Кenh-i = (0.79 ± 0.24) + (42.9 ± 1.2) × e-(0.18 ± 0.01) × day.