Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Matlab data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery

Purpose:Verification of the mechanical isocenter position is required as part of comprehensive quality assurance programs for stereotactic radiosurgery/radiotherapy (SRS/SRT) treatments. Several techniques have been proposed for this purpose but each of them has certain drawbacks. In this paper, a new efficient and more comprehensive method using cine-EPID images has been introduced for automatic verification of the isocenter with sufficient accuracy for stereotactic applications. Methods: Using a circular collimator fixed to the gantry head to define the field, EPID images of a Winston-Lutz phantom were acquired in cine-imaging mode during 360 deg. gantry rotations. A robust matlab code was developed to analyze the data by finding the center of the field and the center of the ball bearing shadow in each image with sub-pixel accuracy. The distance between these two centers was determined for every image. The method was evaluated by comparison to results of a mechanical pointer and also by detection of a manual shift applied to the phantom position. The repeatability and reproducibility of the method were tested and it was also applied to detect couch and collimator wobble during rotation. Results:The accuracy of the algorithm was 0.03 {+-} 0.02 mm. The repeatability was less than 3 {mu}m and the reproducibility was less than 86 {mu}m. The time elapsed for the analysis of more than 100 cine images of Varian aS1000 and aS500 EPIDs were {approx}65 and 20 s, respectively. Processing of images taken in integrated mode took 0.1 s. The output of the analysis software is printable and shows the isocenter shifts as a function of angle in both in-plane and cross-plane directions. It gives warning messages where the shifts exceed the criteria for SRS/SRT and provides useful data for the necessary adjustments in the system including bearing system and/or room lasers. Conclusions: The comprehensive method introduced in this study uses cine-images, is highly accurate, fast, and independent of the observer. It tests all gantry angles and is suitable for pretreatment QA of the isocenter for stereotactic treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 25: Sensitivity to inhomogeneities for an in-vivo EPID dosimetry method

Introduction: The electronic portal imaging device (EPID) has the potential to be used for in vivo dosimetry during radiotherapy as an additional dose delivery check. We recently proposed a simple method of using the EPID for 2D-IVD based on correlation ratios. In this work we have investigated the sensitivity of our EPID-IVD to inhomogeneities. Methods: We used slab phantoms that simulate water, bone, and lung, arranged in various geometries. To simulate body contours non-orthogonal to the field, we used a water wedge. CT data of these phantoms was imported into MATLAB, in conjunction with EPID images acquired during irradiation, to calculate dose inside the phantom in isocenter plane. Each phantom was irradiated using a linear accelerator while images were acquired with the EPID (cine mode). Comparisons between EPID-calculated and TPS dose maps were: pixel-by-pixel dose difference, and 3%,3mm gamma evaluation. Results: In the homogeneous case, CAX dose difference was <1%, and 3%,3mm gamma analysis yielded 99% of points with gamma<1. For the inhomogeneous phantoms, agreement decreased with increasing inhomogeneity reaching up to 10% CAX dose difference with 10cm of lung. Results from the water wedge phantom suggest that the EPID-calculated dose can account for surface irregularities of approximately ±3cm. Conclusions: The EPID-based IVD investigated has limitations in the presence of large inhomogeneities. Nonetheless, CAX doses never differed by >15% from the TPS. This suggests that this EPID-IVD is capable of detecting gross dose delivery errors even in the presence of inhomogeneities, supporting its utility as an additional patient safety device.

60 APPLIED LIFE SCIENCES↗

SU-D-204-07: Comparison of AAPM TG150 Draft Image Receptor Tests with Vendor Automated QC Tests for Five Mobile DR Units

Purpose: To determine the consistency of digital detector (DR) tests recommended by AAPM TG150 and tests provided by commercially available DirectView Total Quality Tool (TQT). Methods: The DR tests recommended by the TG150 Detector Subgroup[1] were performed on 4 new Carestream DRX-Revolution and one Carestream DRX1C retrofit of a GE AMX-4 that had been in service for three years. After detector calibration, flat-field images plus images of two bar patterns oriented parallel and perpendicular to the A-C axis, were acquired at conditions recommended by TG150. Raw images were harvested and then analyzed using a MATLAB software previously validated[2,3,4]. Data were analyzed using ROIs of two different dimensions: 1) 128 x 128 ROIs matching the detector electronics; and 2) 256 x 256 ROIs, each including 4 adjacent smaller ROIs. TG150 metrics from 128 x 128 ROIs were compared to TQT metrics, which are also obtained from 128 x 128 ROIs[5]. Results: The results show that both TG150 and TQT measurements were consistent among these detectors. Differences between TG150 and TQT values appear systematic. Compared with 128 x 128 ROIs, noise and SNR non-uniformity were lower with 256 x 256 ROIs, although signal non-uniformity was similar, indicating detectors were appropriately calibrated for gain and offset. MTF of the retrofit unit remained essentially the same between 2012 and 2015, but was inferior to the new units. The older generator focal spot is smaller (0.75mm vs. 1.2mm), and the SID for acquisition is 182cm as well, so focal spot dimensions cannot explain the difference. The difference in MTF may be secondary to differences in generator X-ray spectrum or by unannounced changes in detector architecture. Further investigation is needed. Conclusion: The study shows that both TG150 and TQT tests are consistent. The numerical value of some metrics are dependent on ROI size.

60 APPLIED LIFE SCIENCES↗

High fidelity nuclear energy system optimization towards an environmentally benign, sustainable, and secure energy source.

The impact associated with energy generation and utilization is immeasurable due to the immense, widespread, and myriad effects it has on the world and its inhabitants. The polar extremes are demonstrated on the one hand, by the high quality of life enjoyed by individuals with access to abundant reliable energy sources, and on the other hand by the global-scale environmental degradation attributed to the affects of energy production and use. Thus, nations strive to increase their energy generation, but are faced with the challenge of doing so with a minimal impact on the environment and in a manner that is self-reliant. Consequently, a revival of interest in nuclear energy has followed, with much focus placed on technologies for transmuting nuclear spent fuel. The performed research investigates nuclear energy systems that optimize the destruction of nuclear waste. In the context of this effort, nuclear energy system is defined as a configuration of nuclear reactors and corresponding fuel cycle components. The proposed system has unique characteristics that set it apart from other systems. Most notably the dedicated High-Energy External Source Transmuter (HEST), which is envisioned as an advanced incinerator used in combination with thermal reactors. The system is configured for examining environmentally benign fuel cycle options by focusing on minimization or elimination of high level waste inventories. Detailed high-fidelity exact-geometry models were developed for representative reactor configurations. They were used in preliminary calculations with Monte Carlo N-Particle eXtented (MCNPX) and Standardized Computer Analysis for Licensing Evaluation (SCALE) code systems. The reactor models have been benchmarked against existing experimental data and design data. Simulink{reg_sign}, an extension of MATLAB{reg_sign}, is envisioned as the interface environment for constructing the nuclear energy system model by linking the individual reactor and fuel component sub-models for overall analysis of the system. It also provides control over key user input parameters and the ability to effectively consolidate vital output results for uncertainty/sensitivity analysis and optimization procedures. The preliminary analysis has shown promising advanced fuel cycle scenarios that include Pressure Water Reactors Pressurized Water Reactors (PWRs), Very High Temperature Reactors (VHTRs) and dedicated HEST waste incineration facilities. If deployed, these scenarios may substantially reduce nuclear waste inventories approaching environmentally benign nuclear energy system characteristics. Additionally, a spent fuel database of the isotopic compositions for multiple design and control parameters has been created for the VHTR-HEST input fuel streams. Computational approaches, analysis metrics, and benchmark strategies have been established for future detailed studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid Process to Generate Beam Envelopes for Optical System Analysis

The task of evaluating obstructions in the optical throughput of an optical system requires the use of two disciplines, and hence, two models: optical models for the details of optical propagation, and mechanical models for determining the actual structure that exists in the optical system. Previous analysis methods for creating beam envelopes (or cones of light) for use in this obstruction analysis were found to be cumbersome to calculate and take significant time and resources to complete. A new process was developed that takes less time to complete beam envelope analysis, is more accurate and less dependent upon manual node tracking to create the beam envelopes, and eases the burden on the mechanical CAD (computer-aided design) designers to form the beam solids. This algorithm allows rapid generation of beam envelopes for optical system obstruction analysis. Ray trace information is taken from optical design software and used to generate CAD objects that represent the boundary of the beam envelopes for detailed analysis in mechanical CAD software. Matlab is used to call ray trace data from the optical model for all fields and entrance pupil points of interest. These are chosen to be the edge of each space, so that these rays produce the bounding volume for the beam. The x and y global coordinate data is collected on the surface planes of interest, typically an image of the field and entrance pupil internal of the optical system. This x and y coordinate data is then evaluated using a convex hull algorithm, which removes any internal points, which are unnecessary to produce the bounding volume of interest. At this point, tolerances can be applied to expand the size of either the field or aperture, depending on the allocations. Once this minimum set of coordinates on the pupil and field is obtained, a new set of rays is generated between the field plane and aperture plane (or vice-versa). These rays are then evaluated at planes between the aperture and field, at a desired number of steps perceived necessary to build up the bounding volume or cone shape. At each plane, the ray coordinates are again evaluated using the convex hull algorithm to reduce the data to a minimal set. When all of the coordinates of interest are obtained for every plane of the propagation, the data is formatted into an xyz file suitable for FRED optical analysis software to import and create a STEP file of the data. This results in a spiral-like structure that is easily imported by mechanical CAD users who can then use an automated algorithm to wrap a skin around it and create a solid that represents the beam.

Howard, Joseph↗

Thermochemical Ablation Analysis of the Orion Heatshield

The Orion Multi-Purpose Crew Vehicle will one day carry astronauts to the Moon and beyond, and Orion's heatshield is a critical component in ensuring their safe return to Earth. The Orion heatshield is the structural component responsible for absorbing the intense heating environment caused by re-entry to Earth's atmosphere. The heatshield is primarily composed of Avcoat, an ablative material that is consumed during the re-entry process. Ablation is primarily characterized by two processes: pyrolysis and recession. The decomposition of in-depth virgin material is known as pyrolysis. Recession occurs when the exposed surface of the heatshield reacts with the surrounding flow. The Orion heatshield design was changed from an individually filled Avcoat honeycomb to a molded block Avcoat design. The molded block Avcoat heatshield relies on an adhesive bond to keep it attached to the capsule. In some locations on the heatshield, the integrity of the adhesive bond cannot be verified. For these locations, a mechanical retention device was proposed. Avcoat ablation was modelled in CHAR and the in-depth virgin material temperatures were used in a Thermal Desktop model of the mechanical retention device. The retention device was analyzed and shown to cause a large increase in the maximum bondline temperature. In order to study the impact of individual ablation modelling parameters on the heatshield sizing process, a Monte Carlo simulation of the sizing process was proposed. The simulation will give the sensitivity of the ablation model to each of its input parameters. As part of the Monte Carlo simulation, statistical uncertainties on material properties were required for Avcoat. Several properties were difficult to acquire uncertainties for: the pyrolysis gas enthalpy, non-dimensional mass loss rate (B´c), and Arrhenius equation parameters. Variability in the elemental composition of Avcoat was used as the basis for determining the statistical uncertainty in pyrolysis gas enthalpy and B´c. A MATLAB program was developed to allow for faster, more accurate and automated computation of Arrhenius reaction parameters. These parameters are required for a material model to be used in the CHAR ablation analysis program. This MATLAB program, along with thermogravimetric analysis (TGA) data, was used to generate uncertainties on the Arrhenius parameters for Avcoat. In addition, the TGA fitting program was developed to provide Arrhenius parameters for the ablation model of the gap filler material, RTV silicone.

Sixel, William↗

Testing and characterization of an IR CBIRD FPA

High performance IR cameras are in great demand for a variety of applications, including defense (e.g. night vision, missile detection) and space (e.g. imaging at IR wavelengths). IR focal plane arrays (FPAs) are an essential component of IR cameras. An FPA is a collection of detectors at the focal plane of an imaging device, where each detector can be thought of a pixel in the image it is detecting. The FPA in this study is based on Complimentary Barrier Infrared Detectors (CBIRDs). The CBIRD FPA was tested by imaging flat black body targets at three different temperatures, 20ºC, 25ºC, and 30ºC, with images captured using SEIR software. The important figures of merit for an IR FPA, Noise Equivalent Difference Temperature (NEDT), Noise Equivalent Irradiance (NEI), detectivity (D*), responsivity, and quantum Efficiency (QE), were extracted from the image data for each individual detector using a MATLAB program, as was the array Modulation Transfer Function MTF. The test results show a mean NEDT of 16.98mK and an MTF of about 0.34 at the Nyquist frequency. Overall, the array performs well in the MWIR range and takes quality IR images.

Das, Tanya↗

Proof Testing Aluminum and Titanium Thin-Walled Tubes for Aerospace Applications

Proof testing aerospace components aids in verifying the structural integrity of flight hardware. This process is often an important step in the certification process for critical parts. Though proof testing is a common practice at NASA and in industry, there is often a need to understand better the effectiveness of proof testing pressure systems discovering cracklike flaws or defects. Often proof tests are used in requirements and in practice as technical rationale for screening critical defects in a part in lieu of performing a non-destructive inspection. The intent of this work is to define proof test failure envelopes for thin-walled tubes composed of two materials: aluminum and titanium. Both materials are common in aerospace thin-walled tubing applications which is why these were the materials chosen for this study. The fracture mechanics software NASGRO was used to perform a parametric study on the effect of defects in thin-walled tubes subjected to proof testing. For both materials, the parameters varied in the NASGRO analyses were aspect ratio, proof test pressure, thickness, diameter, and flaw multiplier. With each case defined as a through crack or failure, the results were then pulled into MATLAB in order to parse through the data and produce failure envelope plots. Failure envelopes were created by meshing a surface in between the minimum proof pressure failing data points. As expected, based on material properties, the plots indicated the aluminum material would fail at much lower proof tests than the titanium. The parametric data and failure envelopes may be used as general qualitative insight on the effectiveness of proof testing thin-walled tubes of similar alloys.

Leah B Davis↗

SWinzip v. 1.0

SWinzip is a Matlab and C++ library for scientific lossy data compression and reconstruction using compressed sensing and tree-wavelets transforms. These methods are known for their large compression and usefulness in data analytics such as features extraction. Compressed sensing and wavelets methods rely heavily on sparse and dense linear algebra operations implemented through the Boost codes in our library. SWinzip accommodates data represented on both regular grids (e.g. image data) and point-clouds (e.g. unstructured meshes).

Salloum, Maher↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laser Diode Analysis and Verification (Professional Report)

The goal of this project at Lawrence Livermore National Laboratory (LLNL) was focused on analyzing and verifying laser diodes to ensure that the diodes meet requirements for LLNL mission applications. The different stages of this testing were documented in a process flow map which included location color coding so that each step was clearly defined in scope and location of appropriate testing facility. Data were collected and analyzed and compared to minimum acceptable values to see if requirements were met. The process map documents the initial receipt, inspection, and testing of the laser diodes. Initial inspections started with Keyence Microscope imaging and then moved on to High Potential, Ramp, and Burst Testing. Data from the diode testing were processed through MATLAB and Python codes to verify various metrics such as slope efficiency, threshold current, back irradiance, and beam divergence met requirements. These metrics were then recorded in Excel summary reports. Approximately 95% of the laser diodes passed all tests. Presentations were given to Lawrence Livermore’s internal leadership team, an external partner, and to a Lab-wide audience. The data released for this report was constrained by information protection considerations of LLNL’s national security missions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hawaii Wave Surge Energy Converter (HAWSEC) OSU O.H. Hinsdale Basin

The following information and metadata applies to both the Phase I (Hydrodynamics) and Phase II (Full System Power Take-Off) zip folders which contain testing data from the OSU (Oregon State University) O.H. Hinsdale Wave Research Laboratory, from both OSU and the University of Hawaii at Manoa (UH). See zip folders provided further below in the downloads section. For experimental data of the full system, including PTO, see Phase II dataset. There are two main directories in each Phases's zip folder: "OSU_data" and "UH_data". The "OSU_data" directory contains data collected from their DAQ (data acquisition system), which includes all wave gauge observations, as well as body motions derived from their Qualisys motion tracking system. The organization of the directory follows OSU's convention. Detailed information on the instrument setup can be found under "OSU_data/docs/setup/instm_locations". The experiments conducted are documented in the "OSU_data/docs/daq_logs", which provides the trial number to the corresponding data located under "OSU_data/data" in several formats (e.g., ".mat" and ".txt"). Inside the trial directory, data is provided for each of the instruments defined in "OSU_data/docs/setup/instm_locations". The "UH_data" directory contains data collected from their DAQ. The data is stored in a ".tdms" file format. There are free plug-ins for Microsoft Excel and MathWorks MATLAB to read the ".tdms" format. Below are a few links providing methods to read in the data, but a Google search should identify alternatives sources if these no longer exist (valid as of January 2024): Excel: http://www.ni.com/example/27944/en/ MATLAB: https://www.mathworks.com/matlabcentral/fileexchange/30023-tdms-reader The Excel plugin is recommend to get a quick overview of the data. The UH data is organized by directory name, in which the sub-directories for each experiment contains a directory whose name defines the wave height and period for the experimental data within. For example, a directory name "H02_T0275" corresponds to an experiment with wave height 0.1m and a period of 2.75s. For random wave data, the gamma value is also included in the directory name. For example, a directory name "H02_T0225_G18" corresponds to an experiment with a significant wave height of 0.2m, a peak period of 2.25s, and a gamma value of 1.8, with each spectra being a TMA spectrum. For the free decay experiments, the directory name is defined by the initial angular displacement. For example, a directory name "ang05_run01" corresponds to an experiment with an initial angular displacement of 5 degrees. There is a dataset in the UH data for each corresponding experiment defined in the OSU DAQ logs. The ".tdms" data is output from the DAQ at fixed intervals. Therefore, if multiple files are contained within the folder, the data will need to be stitched together. Within the UH dataset, there are two input channels from the OSU DAQ providing a random square wave signal for time synchronization ("ENV-WHT-0010") and a high/low signal ("ENV-WHT-0012") to identify when the wave maker is active (+5V). The UH data is logged as a collection of channel outputs. Channels not in use for the OSU testing (either Phase I or Phase II) are marked "nan" below. If the sensor is disconnected, it will record noise throughout the experiment. Below are the channel definitions in terms of what they measure: GPS Time = time CYL-POS-0001 = position between flap and fixed reference CYL-LCA-0001 = force between flap and hydraulic cylinder REC-LPT-0001 = nan REC-HPT-0001 = nan REC-HPT-0002 = nan REC-HPT-0003 = nan HHT-HPT-0001 = pressure at exhaust ("head" only) REC-FQC-0001 = nan REC-FQC-0002 = nan HHT-FQC-0001 = flow at exhaust ("head" only) ENV-WHT-0001 = nan ENV-WHT-0002 = nan ENV-WHT-0003 = nan ENV-WHT-0010 = random signal from OSU DAQ ENV-WHT-0012 = high/low signal from OSU DAQ Also included is a calibration curve to convert the string pot data to flap pi...

16 TIDAL AND WAVE POWER↗

Improving Adhesive Bondline Time of Flight Predictions During Autoclave Cure Utilizing Machine Learning

Composite materials are increasingly being used in aerospace applications due to their superior strength-to-weight ratio compared to commonly used metals. A current limitation to widespread adoption is the certification of adhesively bonded joints. One approach to improving adhesive bonding in composites is accurately measuring the thickness of adhesive bondlines in composite laminates. Precise bondline thickness control is essential for aerospace applications where adhesive layer thickness directly affects joint fracture properties and structural performance. This study focused on implementing machine learning techniques to determine the ultrasonic time of flight (directly correlated to thickness) in adhesive bondlines throughout autoclave cure cycles. A high-temperature (use up to 180°C) ultrasonic scanning system was deployed in an autoclave to provide time of flight data through composite panels. Three experiments were conducted on the curing of 305 mm × 305 mm unidirectional composite panels. In the first experiment, a piecewise function was fit for the temperature correction factor to account for changing autoclave temperatures. Due to deficiencies in the first calibration experiment, a second experiment was run, and the results were used to train a machine learning model. The revised experiment, in combination with the machine learning model, significantly increased the accuracy of the bondline time of flight predictions (~14% error reduced to <1%). Data was processed using the Regression Learner Application in MATLAB®, with a Support Vector Machine selected for the model. The result was a machine learning algorithm capable of reliably quantifying ultrasonic time of flight through adhesive bondlines. The third experiment provided independent test data for the machine learning model, demonstrating that the model produces accurate predictions from data beyond its training set.

Machine Learning↗

SU-E-T-206: Improving Radiotherapy Toxicity Based On Artificial Neural Network (ANN) for Head and Neck Cancer Patients

Purpose/Objective(s): The aim of this study is to build the estimator of toxicity using artificial neural network (ANN) for head and neck cancer patients Materials/Methods: An ANN can combine variables into a predictive model during training and considered all possible correlations of variables. We constructed an ANN based on the data from 73 patients with advanced H and N cancer treated with external beam radiotherapy and/or chemotherapy at our institution. For the toxicity estimator we defined input data including age, sex, site, stage, pathology, status of chemo, technique of external beam radiation therapy (EBRT), length of treatment, dose of EBRT, status of post operation, length of follow-up, the status of local recurrences and distant metastasis. These data were digitized based on the significance and fed to the ANN as input nodes. We used 20 hidden nodes (for the 13 input nodes) to take care of the correlations of input nodes. For training ANN, we divided data into three subsets such as training set, validation set and test set. Finally, we built the estimator for the toxicity from ANN output. Results: We used 13 input variables including the status of local recurrences and distant metastasis and 20 hidden nodes for correlations. 59 patients for training set, 7 patients for validation set and 7 patients for test set and fed the inputs to Matlab neural network fitting tool. We trained the data within 15% of errors of outcome. In the end we have the toxicity estimation with 74% of accuracy. Conclusion: We proved in principle that ANN can be a very useful tool for predicting the RT outcomes for high risk H and N patients. Currently we are improving the results using cross validation.

60 APPLIED LIFE SCIENCES↗

Pacific Marine Energy Center Laser Doppler Velocimetry Commissioning

First commissioning data for the new laser doppler velocimetry (LDV) system that will be used at the Tyler Flume at the University of Washington. The LDV system can measure three components of velocity at a point. For this dataset the three components were operated in non-coincident mode and data were acquired at the center of the empty facility. Comparisons of freestream turbulence were made with a Vectrino slightly upstream of the LDV measurement location.

16 TIDAL AND WAVE POWER↗

Identification, Uncertainty Characterization and Robust Control Synthesis Applied to Large Flexible Structures Control

This paper demonstrates an approach to frequency domain identification for the explicit purpose of designing robust H(infinity) controllers. The approach transforms raw experimental data into a plant set estimate directly usable by modern robust control design software(e.g., Matlab Robust Control Toolboxes [11][2]). A key issue in control design from raw data is the question of whether the controller will work when applied to the true system. The main feature fo this approach is that the resulting controller in guaranteed to work as designed(when applied to the true system) to a prescribed statistical confidence. While the overall methodology addresses key theoretical issues, it has at the same time been specifically designed to support practical implementations. A simulation example is included to demonstrate the overall approach.

software↗

TEAMER - AquaHarmonics High Fidelity WEC Sim PTO and Control Model Validation, Test Logs and Results

Collaborative effort between AquaHarmonics, Sandia National Laboratories (SNL), and the National Renewable Energy Laboratory (NREL) to revise and validate Aquaharmonics' full wave to wire model, allowing for reduced uncertainty and increased understanding of design requirements of a utility scale wave energy converter (WEC). SNL and NREL in collaboration with AquaHarmonics, will set up and run WEC Simulator (WEC-Sim) models of the AquaHarmonics WEC, building off past model developments for inclusion of custom PTO (power take-off) dynamics. The intent is to review, update, and verify or validate a new WEC-Sim model against wave tank experimental data. Furthermore, the WEC-Sim model will be coupled to an energy storage system model to better understand the wave-to-wire functionality. This data set is described in the "Test Log" excel file. Please refer to that document for details on each specific test date/time, constraint parameters and model hardware setup details. Sim model can be found in the associated MHKDR link below.

16 TIDAL AND WAVE POWER↗

Assessment of Long Term Creep Using Strain Rate Matching From the Stepped Isostress Method

Creep testing is an ongoing need, particularly with the development of new candidate alloy systems for advanced energy systems. The conventional creep test (CT) is regarded as a proven method to gather creep data however, the test is impractical due to being real-time: lasting up to 105 hours to characterize the service of long-lived turbomachinery components. Accelerated methods to gather the long-term creep properties of materials are needed to reduce the time to qualification of new materials. The time-temperature-stress-superposition principle (TTSSP) and the derivative time-temperature superposition principle (TTSP), time-stress superposition principle (TSSP), stepped isothermal method (SIM), and stepped isostress method (SSM) are accelerated creep tests (ACT) commonly used to predict the long-term creep behaviors of polymers and composites. The TTSP and TSSP tests require multiple specimen tested at various temperatures/stresses whereas the SIM and SSM tests employ a single specimen where temperature/stress are periodically step increased until rupture. The stepped creep deformation curve can then be time and strain shifted to produce a master creep curve. While these ACTs are useful tools to predict long-term creep, the drawback is the lack of mathematical laws to determine the virtual start time and time shift factors, especially for different materials. In this paper, a new self-calibration approach is developed and compared to existing SSM data for Kevlar 49. This new approach focuses on matching the creep strain rates between stress steps and fitting the data to a master curve using a modified theta projection model. This is performed using a MATLAB code consisting of five subroutines. The first subroutine takes the stress, time, and creep strain from SSM/SIM tests, and segregates the data intro arrays corresponding to each stress level. The second subroutine finds the constants for the modified theta projection model for each stress level. The third subroutine performs a time shift adjustment using creep strain rate matching. The fourth subroutine calculates the accelerated time of rupture. The last subroutine generates accelerated creep versus time plots. Kevlar 49 SSM data is gathered from literature and run through the MATLAB code. The master curves generated from the MATLAB are compared to the conventional creep curve of Kevlar 49 as well as the master curve gathered from literature in order to validate the feasibility of this new approach. The goal of this project is to vet if the self-calibration approach can produce results similar to the reference calibration approach.

36 MATERIALS SCIENCE↗