Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Matched filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable bandpass filter channel for signal spectrum analysis and signal discrimination is presented, including performance improvements to stability and precise matching between filter stages. The 8 th -order filter channel achieves an effective Q-factor of 4.5 and dynamic range of 60 dB, has an operational frequency range from 2 kHz to 100 kHz, and consumes 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology is selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2 nd -order filter cells and is fabricated in 130-nm 1.2-V CMOS technology, making it suitable for use in monolithic integrated spectral analysis (MISA) applications.

Long, Gavin↗

Tunable Mid-wave Infrared Fabry-Perot Bandpass Filters Using Phase-Change GeSbTe

Tunable mid-wave infrared (MWIR) filters are highly desirable in a wide variety of imaging and sensing, as the MWIR contains numerous spectral signatures. We fabricated spectrally-tunable Fabry-Perot bandpass filters operating across the MWIR by utilizing the phase-change material GeSbTe (GST) as a tunable cavity medium between distributed Bragg reflectors. The induced refractive index modulation of the GST increases the cavity’s optical path length, tuning the passband. Our filters have 300-nm spectral tunability, 60-75% transmission efficiencies, and 50-65 nm narrowband FWHMs (Q-factor 70-90). We demonstrate multispectral thermal imaging and dynamic gas sensing by matching the filter’s passband (~ 4.25μm) to a CO2 vibrational-absorption mode.

Tunable filter↗

Studies of the marine crustal magnetization at intermediate wavelengths

The data can be filtered at intermediate wavelengths to provde a data set which complements the satellite fields of MAGSAT, TSS and GRM. The filtered marine data set provides a high resolution data set which is closer to the source bodies than satellite survey data. However, the GRM and TSS could provide the necessary resolution to match the filtered sea surface field. The added resolution determines the nature of crustal magnetizations which give rise to the intermediate wavelength field. It is found that remanent magnetization is an important component over the oceans. Crustal deformation and plate motions result in magnetization vectors which differ significantly from the present day field directions. Induced magnetization or GRM are important components over the oceanic plateaus and spreading centers.

Labrecque, J. L.↗

A low noise 230 GHz heterodyne receiver employing .25 sq micron area Nb/AlO(x)/Nb tunnel junctions

Recent results for a full height rectangular waveguide mixer with an integrated IF matching network are reported. Two 0.25 sq micron Nb/AlO(x)/Nb superconducting insulating superconducting (SIS) tunnel junctions with a current density of about 8500 A/sq cm and omega RC of about 2.5 at 230 GHz have been tested. Detailed measurements of the receiver noise have been made from 200-290 GHz for both junctions at 4.2 K. The lowest receiver noise temperatures were recorded at 239 GHz, measuring 48 K DSB at 4.2 K and 40 K DSB at 2.1 K. The 230 GHz receiver incorporates a one octave wide integrated low pass filter and matching network which transforms the pumped IF junction impedance to 50 ohms over a wide range of impedances.

Kooi, Jacob W.↗

The Distribution of Titanium in Lunar Soils on the Basis of Sensor and In Situ Data Fusion

A variety of remote-sensing measurements have been used to map the distribution of elements on the Moon as a means of providing constraints on the processes from which its crust and major terranes originated. Discussed here is Ti, which is incorporated into refractory minerals such as ilmenite during the latter stages of differentiation, and is thus a most useful element for understanding mare basalt petrogenesis. One of the earliest Ti maps showed Ti variations in nearside maria on the basis of groundbased spectral reflectance measurements. A map of Ti derived from gamma-ray measurements on Apollo 15 and 16 was produced at about the same time, and was improved upon considerably by Davis and coworkers, who effectively removed sources of spurious variation from Fe and Al or REE (e.g., Th) interference, and calibrated Ti on the bases of landing-site soil averages. In recent years, spectral reflectance measurements from Clementine have been used by Lucey and coworkers to produce global Ti distribution maps as well. As we indicated previously, the Lucey and Davis maps agree to first order. Meanwhile, we are using the concept of sensor data fusion to combine measurements from the AGR (Apollo gamma-ray) and CSR (Clementine Spectral Reflectance) techniques with ground truth from lunar soils to utilize the differences between the two maps to understand the distribution of Ti within lunar soil components, as we have done with Fe. This technique should be verified and applied on Lunar Prospector gamma-ray measurements of Ti, as the calibrated data become available within the next couple of years. Lunar Ti is found principally in the mineral ilmenite, and is associated with certain components of lunar soil: crystalline Ilmenite mineral fragments and high Ti-bearing glass. All data indicate that Ti is associated with maria and mafic minerals. In AGR and CSR datasets, Ti is highest on the nearside and in the maria, particularly in southern Serenitatis/northern Tranquillitatis and northwestern Procellarum. Unlike CSR-derived values, AGR Ti values show modest increase (up to 0.7%) on the northern farside. Both techniques show a primarily unimodal distribution with a shoulder in the high Ti direction and a primary mode at approximately 0.2% (0.15% for CSR and 0.25% for AGR data), but the AGR Ti data have more structure in the shoulder, including an apparent minor mode at 1.2% Ti, representing non-highland areas. Recalibrating the two datasets on the basis of matching the peaks and range on the histograms would not account for this additional structure in the AGR data. Low Ti areas, which occur predominantly on the farside, are not represented well in the lunar sample collection, although several meteorites thought to be of lunar highland origin show Ti abundances averaging about 0.2%. (Error bars on AGR Ti values are about 0.5%.) Gamma-ray measurements reflect intrinsic Ti surface composition, regardless of the physical or chemical state of Ti. Lucey and coworkers have attempted to produce an equivalent bulk Ti map by normalizing the spectral feature at 415 nm to remove the effects of physical variations from soil to soil. The normalization is based on laboratory measurements of available samples, primarily nearside maria, and is undoubtedly optimized for the proportions in which Ti- components are found in these soils. In particular, mare soils tend to have a much higher proportion of opaque mineral grains, which appears to be well correlated with Ti abundance. The relationship between Ti abundance and proportion of Ti-bearing glass (weighted for Ti abundance) is not as direct. Also shows the relationship between landing site soil average, AGR, and CSR Ti abundances (with CSR filtered to match resolution and field of view of AGR data). AGR Ti values show the best agreement with Ti soil averages, CSR Ti values being somewhat higher in high-Ti soils, and lower in low-Ti soils. These results would tend to support the argument that the technique for deriving Ti from the CSR measurements is optimized for one of the primary Ti-bearing components, most likely opaque mineral grains, and is thus over-compensating and reporting higher Ti values in mare areas, and underreporting Ti in highland areas with much lower proportions of opaque mineral grains. More information is contained in original.

Clark, P. E.↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced acousto-optic signal processors

The basic acousto-optic signal processing architectures (spectrum analyzer, space-integrating, time-integrating, and triple product processor) systems and algorithms such as the chirp-Z transform are reviewed. New acousto-optic data processing systems and applications that utilze these basic architectures and new ones are described. These include a matched spatial filter acousto-optic processor, two new hybrid time and space-integrating systems, a triple product processor, and four new matrix-vector iterative feedback systems.

Casasent, D.↗

Application of optical correlation techniques to particle imaging velocimetry

Pulsed laser sheet velocimetry yields nonintrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usually MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the partical image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.↗

Achromatic optical correlator for white light pattern recognition

An achromatic optical correlator using spatially multiplexed achromatic matched spatial filters (MSFs) for white light optical pattern recognition is presented. The MSF array is synthesizd using a monochromatic laser and its achromaticity is achieved by adjusting the scale and spatial carrier frequency of each MSF to accommodate the wavelength variations in white light correlation detections. Systems analysis and several experimental results showing the correlation peak intensity using white-light illumination are presented.

Chao, Tien-Hsin↗

Achromatical Optical Correlator

Signal-to-noise ratio exceeds that of monochromatic correlator. Achromatical optical correlator uses multiple-pinhole diffraction of dispersed white light to form superposed multiple correlations of input and reference images in output plane. Set of matched spatial filters made by multiple-exposure holographic process, each exposure using suitably-scaled input image and suitable angle of reference beam. Recording-aperture mask translated to appropriate horizontal position for each exposure. Noncoherent illumination suitable for applications involving recognition of color and determination of scale. When fully developed achromatical correlators will be useful for recognition of patterns; for example, in industrial inspection and search for selected features in aerial photographs.

Chao, Tien-Hsin↗

An optical processor for object recognition and tracking

The design and development of a miniaturized optical processor that performs real time image correlation are described. The optical correlator utilizes the Vander Lugt matched spatial filter technique. The correlation output, a focused beam of light, is imaged onto a CMOS photodetector array. In addition to performing target recognition, the device also tracks the target. The hardware, composed of optical and electro-optical components, occupies only 590 cu cm of volume. A complete correlator system would also include an input imaging lens. This optical processing system is compact, rugged, requires only 3.5 watts of operating power, and weighs less than 3 kg. It represents a major achievement in miniaturizing optical processors. When considered as a special-purpose processing unit, it is an attractive alternative to conventional digital image recognition processing. It is conceivable that the combined technology of both optical and ditital processing could result in a very advanced robot vision system.

Sloan, J.↗

Application of optical correlation techniques to particle imaging

Pulsed laser sheet velocimetry yields noninstrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usuallay MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the particle image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.↗

Polyphase-discrete Fourier transform spectrum analysis for the Search for Extraterrestrial Intelligence sky survey

The sensitivity of a matched filter-detection system to a finite-duration continuous wave (CW) tone is compared with the sensitivities of a windowed discrete Fourier transform (DFT) system and an ideal bandpass filter-bank system. These comparisons are made in the context of the NASA Search for Extraterrestrial Intelligence (SETI) microwave observing project (MOP) sky survey. A review of the theory of polyphase-DFT filter banks and its relationship to the well-known windowed-DFT process is presented. The polyphase-DFT system approximates the ideal bandpass filter bank by using as few as eight filter taps per polyphase branch. An improvement in sensitivity of approx. 3 dB over a windowed-DFT system can be obtained by using the polyphase-DFT approach. Sidelobe rejection of the polyphase-DFT system is vastly superior to the windowed-DFT system, thereby improving its performance in the presence of radio frequency interference (RFI).

Zimmerman, G. A.↗

Where have all the sources gone?

In the continuing quest for an understanding of the cosmic x-ray background, the most difficult technical barrier remains the mismatch between the wavelength band in which the discrete source populations are best characterized (0.1 to 3.5 keV), and the band in which the spectrum of the background is well determined and the bulk of the energy density resides (3.5 to 50 keV). A progress report in an attempt to resolve this conundrum using the Einstein Imaging Proportional Counter (IPC) database and analysis system is presented. The IPC data base is described and how it can be used to search both for missing clusters of galaxies and highly obscured active galactic nuclei is addressed. All 4083 imaging proportional counter observations were examined after flat fielding and editing to optimize sensitivity for diffuse emission on various size scales ranging up to 10 feet. A '2 sigma source' catalog which, when filtered by matching with source catalogs from other wavelength regimes, is shown to reveal new source classes which may be significant contributors to the cosmic x-ray background is being constructed. Optimization techniques are described and the source catalogs which result are presented. Limits on the contributions both classes of sources make to resolving the discrepancy with the higher energy observations are set.

Helfand, D. J.↗

Recent advances in superconducting-mixer simulations

Over the last few years, considerable progress have been made in the development of techniques for fabricating high-quality superconducting circuits, and this success, together with major advances in the theoretical understanding of quantum detection and mixing at millimeter and submillimeter wavelengths, has made the development of CAD techniques for superconducting nonlinear circuits an important new enterprise. For example, arrays of quasioptical mixers are now being manufactured, where the antennas, matching networks, filters and superconducting tunnel junctions are all fabricated by depositing niobium and a variety of oxides on a single quartz substrate. There are no adjustable tuning elements on these integrated circuits, and therefore, one must be able to predict their electrical behavior precisely. This requirement, together with a general interest in the generic behavior of devices such as direct detectors and harmonic mixers, has lead us to develop a range of CAD tools for simulating the large-signal, small-signal, and noise behavior of superconducting tunnel junction circuits.

Withington, S.↗

Evaluation of visual acuity with Gen 3 night vision goggles

Using laboratory simulations, visual performance was measured at luminance and night vision imaging system (NVIS) radiance levels typically encountered in the natural nocturnal environment. Comparisons were made between visual performance with unaided vision and that observed with subjects using image intensification. An Amplified Night Vision Imaging System (ANVIS6) binocular image intensifier was used. Light levels available in the experiments (using video display technology and filters) were matched to those of reflecting objects illuminated by representative night-sky conditions (e.g., full moon, starlight). Results show that as expected, the precipitous decline in foveal acuity experienced with decreasing mesopic luminance levels is effectively shifted to much lower light levels by use of an image intensification system. The benefits of intensification are most pronounced foveally, but still observable at 20 deg eccentricity. Binocularity provides a small improvement in visual acuity under both intensified and unintensified conditions.

Bradley, Arthur↗

Laser Image Contrast Enhancement System

An optical image enhancement system provides improved image contrast in imaging of a target in high temperature surroundings such as a furnace. The optical system includes a source of vertically polarized light such as laser and a beam splitter for receiving the light and directing the light toward the target. A retardation plate is affixed to a target-facing surface of the beam splitter and a vertical polarizer is disposed along a common optical path with the beam splitter between the retardation plate and the target. A horizontal polarizer disposed in the common optical path, receives light passing through a surface of the beam splitter opposed to the target-facing surface. An image detector is disposed at one end of the optical path. A band pass filter having a band pass filter characteristic matching the frequency of the vertically polarized light source is disposed in the path between the horizontal polarizer and the image detector. The use of circular polarization, together with cross polarizers, enables the reflected light to be passed to the detector while blocking thermal radiation.

Robert L Kurtz↗