Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNP6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Testing of ENDF71x: A new ACE-formatted neutron data library based on ENDF/B-VII.1

The ENDF71x library [1] is the most thoroughly tested set of ACE-format data tables ever released by the Nuclear Data Team at Los Alamos National Laboratory (LANL). It is based on ENDF/B-VII. 1, the most recently released set of evaluated nuclear data files produced by the US Cross Section Evaluation Working Group (CSEWG). A variety of techniques were used to test and verify the ENDF7 1x library before its public release. These include the use of automated checking codes written by members of the Nuclear Data Team, visual inspections of key neutron data, MCNP6 calculations designed to test data for every included combination of isotope and temperature as comprehensively as possible, and direct comparisons between ENDF71x and previous ACE library releases. Visual inspection of some of the most important neutron data revealed energy balance problems and unphysical discontinuities in the cross sections for some nuclides. Doppler broadening of the total cross sections with increasing temperature was found to be qualitatively correct. Test calculations performed using MCNP prompted two modifications to the MCNP6 source code and also exposed bad secondary neutron yields for {sup 231,233}Pa that are present in both ENDF/B-VII.1 and ENDF/B-VII.0. A comparison of ENDF71x with its predecessor ACE library, ENDF70, showed that dramatic changes have been made in the neutron cross section data for a number of isotopes between ENDF/B-VII.0 and ENDF/B-VII.1. Based on the results of these verification tests and the validation tests performed by Kahler, et al. [2], the ENDF71x library is recommended for use in all Monte Carlo applications. (authors)

97 MATHEMATICS AND COMPUTING↗

K-Eigenvalue sensitivities of secondary distributions of continuous-energy data

MCNP6 has the capability to produce energy-resolved sensitivity profiles for secondary distributions (fission {Chi} and scattering laws). Computing both unconstrained and constrained profiles are possible. Verification is performed with analytic test problems and a comparison to TSUNAMI-3D, and the comparisons show MCNP6 calculates correct or consistent results. Continuous-energy calculations are performed for three fast critical experiments: Jezebel, Flattop, and copper-reflected Zeus. The sensitivities to the secondary distributions (integrated over chosen energy ranges) are of similar magnitude to those of many of the cross sections, demonstrating the possibility that integral experiments are useful for assessing the fidelity of these data as well. (authors)

97 MATHEMATICS AND COMPUTING↗

Analysis of a Loop for Fission Gas Release and Monitoring at the PULSTAR Reactor

Modern nuclear fuel performance analysis tools aim at establishing a predictive approach for examining macroscopic fuel behavior due to fuel gaseous swelling and the associated pellet cladding mechanical interaction (PCMI). In general, the macroscopic behavior is highly sensitive to understanding microscopically driven phenomena, which in this case is the release of fission gas (i.e., Kr and Xe) from the fuel. Previous studies identified the uncertainties associated with the intra-granular fission gas diffusion coefficient as most limiting for the accuracy of fission gas release calculations. In particular, it was concluded that, in order to improve fission gas release as well as gaseous swelling predictions using fuel performance codes, a better characterization of the diffusion coefficient is needed. This work explores the implementation of an on-line fission gas release and measurement loop at the North Carolina State University (NCSU) PULSTAR reactor. A unique characteristic of this loop is the ability to control the temperature of the fuel samples during irradiation to establish a more accurate correlation between the irradiation conditions and an observable such as the intragranular gas diffusion coefficient. Analysis was performed of an 'in-pile' fission gas release experiment that is currently under implementation at the NCSU PULSTAR reactor. Using MCNP6 calculations and COMSOL simulations the fission rate density and temperature distributions in UO{sub 2} microspheres were estimated. To explore the feasibility of detecting fission gas isotopes, estimates of R/B for {sup 138}Xe were obtained using the equivalent sphere model and combined with MCNP6 predicted B estimates to obtain R. Assuming detection in a typical gamma-ray spectrometry HPGe system, it was conclude that reasonable count rates will be achieved to allow extraction of release information. At this stage, accurate assessment is underway of the performance of various loop components to set the final design criteria in support of loop fabrication. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fukushima Containment Dose Assessment

Dose calculations for a BWR Mark I containment are conducted to complement source term research on the meltdowns at Fukushima Daiichi. These efforts are a primary component of Phase II of the OECD/NEA's Benchmark Study on the Accident at Fukushima Daiichi Nuclear Power Station (BSAF). Phase II of BSAF aims to evaluate radionuclide source terms to the containment and to the environment, radionuclide transport behavior, and dose rates inside and near the plant. The radionuclide-focused goals of Phase II make use of thermal-hydraulic and severe accident insights from Phase I of BSAF, which concentrated on severe accident thermal-hydraulics, core degradation and fuel relocation, reactor pressure vessel (RPV) lower head failure, and containment response. The details and assumptions involved in the severe accident progression have first-order impacts on radionuclide transport and consequent dose rates. An MCNP6 model is created to support the BSAF Phase II investigations. The MCNP6 input represents a boiling water reactor (BWR) Mark I containment and pertinent surrounding structures such the reactor building. This paper examines photon dose rates inside and adjacent to the containment. The spatial distribution and energy spectrum of the source, as well as the overall source magnitude, are informed by MELCOR radionuclide transport calculations in conjunction with ORIGEN-S decay calculations. Initial mesh and ring tally calculations are discussed in relation to plant data. Despite the simplified geometry model and uncertainties of the severe accident source, the preliminary calculations yield impressive agreement with the measured data. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Photoneutron Production Using an Electron Linear Accelerator for Applications in Neutron Imaging

Photoneutron production is possible using an electron linear accelerator and a target capable of generating photonuclear reactions. A short pulse neutron source can be useful for neutron imaging dynamic experiments. This study is aimed at the feasibility of photoneutron production using a 20 MeV electron linear accelerator and tungsten and depleted uranium targets of various thicknesses. MCNP6 (Monte Carlo N-Particle) code will be used to develop a computational model to estimate total neutron yield, and this will be verified at the Idaho State University’s Accelerator Center. After verification of the neutron yield and energy spectra, an additional MCNP6 model will be developed to analyze the neutron imaging processes. This study will potentially prove it is possible to conduct multi-mode imaging experiments on the anticipated Scorpius electron linear accelerator at the Nevada National Security Sites.

43 PARTICLE ACCELERATORS↗

Transport model predictions of 225 Ac production cross sections via energetic p, d and α irradiation of 232 Th targets

Monte Carlo transport codes PHITS and MCNP6 were used to calculate the production cross sections of 225,227 Ac, 227,229 Th, 223,225 Ra, and 229,230,231 Pa via the bombardment of a 232 Th target with energetic protons, deuterons, and α-particles. The incident projectile energies ranged between 10 and 800 MeV/nucleon. When possible, the predicted production cross sections were compared with the available experimental data and other predictions. Here, the degree of the codes’ abilities to match the measured data provides a qualitative assessment of the codes’ abilities to predict data from similar, but unmeasured, projectile/target systems. In addition, a comparison between calculated cross sections and data may provide insight into possible improvements in the physics models employed by those transport codes.

223Ra↗

Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy: Simulation of NIST air-kerma rate eBT calibration standard

Purpose: Dosimetry for the model S700 50 kV electronic brachytherapy (eBT) source (Xoft, Inc., a subsidiary of iCAD, San Jose, CA) was simulated using Monte Carlo (MC) methods by Rivard et al. [“Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent x-ray source: An electronic brachytherapy source,” Med. Phys. 33, 4020–4032 (2006)] and recently by Hiatt et al. [“A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model,” Med. Phys. 42, 2764–2776 (2015)] with improved geometric characterization. Additionally, while these studies examined the dose distribution in water, there have not previously been reports of the eBT source calibration methods beyond that recently reported by Seltzer et al. [“New national air-kerma standard for low-energy electronic brachytherapy sources,” J. Res. Natl. Inst. Stand. Technol. 119, 554–574 (2014)]. Therefore, the motivation for the current study was to provide an independent determination of air-kerma rate at 50 cm in air K air (d = 50 cm) using MC methods for the model S700 eBT source. Methods: Using CAD information provided by the vendor and disassembled sources, an MC model was created for the S700 eBT source. Simulations were run using the mcnp6 radiation transport code for the NIST Lamperti air ionization chamber according to specifications by Boutillon et al. [“Comparison of exposure standards in the 10-50 kV x-ray region,” Metrologia 5, 1–11 (1969)], in air without the Lamperti chamber, and in vacuum without the Lamperti chamber. K air (d = 50 cm) was determined using the *F4 tally with NIST values for the mass energy-absorption coefficients for air. Photon spectra were evaluated over 2π azimuthal sampling for polar angles of 0° ≤ θ ≤ 180° every 1°. Volume averaging was averted through tight radial binning. Photon energy spectra were determined over all polar angles in both air and vacuum using the F4 tally with 0.1 keV resolution. A total of 10 11 simulated histories were run for the Lamperti chamber geometry (statistical uncertainty of 0.14%), with 10 10 histories for the in-air and in-vacuum simulations (statistical uncertainty of 0.04%). The total standard uncertainty in the calculated air-kerma rate determination amounted to 6.8%. Results: MC simulations determined the air-kerma rate at 50 cm from the source with the modeled Lamperti chamber to be (1.850 ± 0.126) × 10 -4 Gy/s, which was within the range of K air (d = 50 cm) values (1.67–2.11) × 10 -4 Gy/s measured by NIST. The ratio of the photon spectra in air and in vacuum were in good agreement above 13 keV, and for θ < 150° where the influence of the Kovar sleeve and the Ag epoxy components caused increased scatter in air. Below 13 keV, the ratio of the photon spectra in air to vacuum exhibited a decrease that was attributed to increased attenuation of the photons in air. Across most of the energy range on the source transverse plane, there was good agreement between the authors' simulated spectra and that measured by NIST. Discrepancies were observed above 40 keV where the NIST spectrum had a steeper fall-off towards 50 keV. Conclusions: Through MC simulations of radiation transport, this study provided an independent validation of the measured air-kerma rate at 50 cm in air at NIST for the model S700 eBT source, with mean results in agreement within 3.3%. Lastly, this difference was smaller than the range (i.e., 23%) of the measured values.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of the Monte Carlo Adjoint-Weighted and Differential Operator Perturbation Methods

Two perturbation theory methodologies are implemented for k-eigenvalue calculations in the continuous-energy Monte Carlo code, MCNP6. A comparison of the accuracy of these techniques, the differential operator and adjoint-weighted methods, is performed numerically and analytically. Typically, the adjoint-weighted method shows better performance over a larger range; however, there are exceptions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark Evaluation of one Dimensional Array of HEU Moderated and Reflected by Lucite [Poster]

Two critical experiments with HEU-Lucite were performed using the Planet Universal Critical Assembly Machine at Los Alamos National Laboratory in 2019. HEU foils were interleaved with Lucite in a column stack for moderation and reflection from the square Lucite plates. The evaluation of the experiments is presented. A Monte-Carlo (MCNP6) calculation model was developed for the determination of uncertainties and their effect on the multiplication factor. Experimental uncertainties were found to be low with the overall uncertainty in k eff approximately 240 pcm. The comparison of calculations with experimental data is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LANL Critical Benchmark Comparison Study and Subsequent Revision for Cases Involving LEU and MIX

As part of an international collaboration within the DOE Nuclear Criticality Safety Program (NCSP), LANL is involved in a comparison study to quantify differences in k-effective results from neutron transport simulations of critical benchmark experiments. The DOE NCSP Mission and Vision details the activity in which the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN) leads the study with LANL, ORNL, and LLNL to compare results of various neutron transport codes and nuclear data libraries for ICSBEP benchmarks held in common by the entities. The task statement from the DOE NCSP Five-Year Execution Plan is given as: "The proposal is for IRSN to lead a new intercomparison based on the MORET code with the latest JEFF-3.3 data and ENDF/B-VIII.0 data, when available, using their existing comprehensive selection of 2,714 benchmarks and collate their results together with those from LLNL (COG), LANL (MCNP) and ORNL (SCALE). Due to the large number of benchmarks involved, this effort is envisioned to take three years with an additional year for IRSN to complete a summary report. The benchmark development will be performed independently to minimize modeling errors through discovery and resolution of discrepant results. A summary report will be generated (led by IRSN) to document the results of this study." This report documents results obtained for revisions made to cases involving Intermediate Enriched Uranium (IEU) and a mixture of Pu and Uranium (MIX), with a focus on the changes made to LANL benchmarks modeled with MCNP6 using ENDF/B-VII.1 nuclear data that appeared to have discrepant results when compared with results of other codes. Feedback was used to pinpoint review of particular benchmark input files and to revise them when necessary. This report documents the results of review and revision of specific benchmarks highlighted as possibly discrepant in the comparison study. In addition, there is an effort tied to this work involving collaboration between LANL XCP and NCS Divisions in the development of a shared review/revision procedure and use of a new benchmark repository.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary of LANL Critical Benchmark Comparison Study and Revisions for Cases Involving HEU, LEU, MIX, and Pu

This report documents results obtained for revisions made to cases involving Highly Enriched Uranium (HEU), Intermediate Enriched Uranium (IEU), a mixture of Pu and Uranium (MIX), as well as Pu cases. A previous summary of revisions for HEU an Pu cases was reported and additional investigations into four cases originally presented therein uncovered further revisions which led to better agreement with other transport codes, those cases are updated in this report. The summary of all cases reported in Reference 2 is updated in this report. In addition, a previous summary of revisions for LEU and MIX was reported, a summary of those revisions in reproduced in this report for a comprehensive summary of changes to benchmarks beginning in fiscal year 2020 to current date. The report focuses on the changes made to LANL benchmarks modeled with MCNP6 using ENDF/B-VII.1 nuclear data that appeared to have discrepant results when compared with results of other codes. Feedback was used to pinpoint review of benchmark input files and to revise them when necessary. This report documents the results of review and revision of specific benchmarks highlighted as possibly discrepant in the comparison study. In addition, there is an effort tied to this work involving collaboration between LANL XCP and NCS Divisions in the development of a shared review/revision procedure and use of a new benchmark repository. LANL has a benchmark library of critical experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook modeled for use with MCNP. This collection is now over 1100 benchmarks, referred to as the Whisper-1.1 library because it is used with the sensitivity/uncertainty package, Whisper, which supports nuclear criticality safety validation and is released with MCNP6.2. The collection, originally created several decades ago, is a combination of smaller collections, which has been revised and expanded, by various groups at LANL over the years. The original authors are no longer at the laboratory and little formal documentation of review and revision of these benchmarks exists today. A branch of the benchmark collection was already the subject of a formal review undertaken by the LANL NCS Division and expanded to include XCP Division.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification and Validation of the New MCNP6.3 Criticality Features

The MCNP6® code, version 6.3, has been extensively verified and validated for many applications. The use of the same default capabilities existing in the MCNP6.2 code are also used in the verification and validation (V&V) of the MCNP6.3 code. In this paper, selected new features, code enhancements, and bug fixes in the MCNP6.3 code that impact criticality safety applications are described and investigated. More specifically, the changes within the MCNP6.3 code that are studied in this work include both the new fission matrix and the Doppler broadening resonance correction (DBRC) features. For nuclear criticality safety applications, the V&V benchmark problems within the criticality, extended criticality, and Rossi-α suites are used to study the upgrades within the MCNP6.3 code. Some additional investigations into benchmarks at elevated temperatures are used to showcase the impacts of the temperature-specific capabilities.

97 MATHEMATICS AND COMPUTING↗

Effective dose rate coefficients for exposure to contaminated soil

The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. As a result, the coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measuring key Sm isotope ratios in irradiated UO 2 for use in plutonium discrimination nuclear forensics

As part of an experimental validation of a nuclear forensics methodology for Pu source reactor-type discrimination, destructive analysis has been performed here on two irradiated UO 2 pellets with different irradiation histories. Analysis has focused on measuring key Sm fission product isotope ratios used in a previously published maximum likelihood methodology to determine the most likely irradiation history of the pellets. A total of 21 Sm isotope ratios were measured within the irradiated pellets, and generally agreed within 20% of the irradiations as simulated using the Monte Carlo Radiation Transport and material depletion code, MCNP6. Results indicate the chosen approach can accurately measure the isotope ratios within 5% experimental error.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo fuel burnup analyses of the Accelerator-Driven Subcritical systems

Here, we discuss the Monte Carlo fuel burnup analysis performed for the Argonne National Laboratory (ANL) Accelerator-Driven Subcritical (ADS) conceptual design. The ANL ADS conceptual design was determined to dispose of the 131 tons of Minor Actinides (MA) fuel of the current United States Spent Nuclear Fuel (SNF) inventory. It uses a neutron source from 1 GeV 25MW proton beam with the liquid lead target to drive the subcritical fission assembly. It utilizes the liquid metal slurry fuel concept to load the MAs fuel. The subcritical fission assembly has a neutron multiplication factor of 0.98. The total fission power generated in the system is about 2.67 GW. The system is designed to operate for 35 full power years. Monte Carlo fuel burnup analyses were performed to calculate the amount of MAs consumed by the ANL ADS conceptual design. The MCNP6 computer program was used to simulate the high energy physics of the protons striking the liquid lead target for generating the neutron source. The MCB5 and SERPENT Monte Carlo burnup computer programs were used to simulate the fuel burnup during the ADS operation. In the ANL ADS conceptual configuration, the reactivity loss during the fuel burnup is compensated by adding fresh fuel into the subcritical assembly. In this paper, both batch and continuous fueling modes are examined. The fresh fuel particles are loaded into the slurry fuel carrier at the beginning of each burnup step of the batch-fueling mode and loaded continuously into the slurry fuel carrier during the operation in the continuous fueling mode. Monte Carlo fuel burnup analyses show that one ANL ADS conceptual design can consume about 25.7 tons of MAs fuel during the 35 full power years with the continuous fueling mode. About five units is required to dispose of the 131 tons of MAs

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quasi-differential neutron induced neutron emissions from 235 U, and 239 Pu

Uncertainty in nuclear reaction cross sections, angular distributions, and other nuclear data directly impact how well simulations of nuclear systems represent physical observations. Here, to determine how well the nuclear data in ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0 evaluations describe the physical behaviour of 235 U, and 239 Pu when subjected to a neutron flux, the neutron emission spectrum was measured for carbon, 93.0% 235 U, and 93.9% 239 Pu samples, and compared against detailed MCNP6 simulations. The measurements were performed at the Los Alamos Neutron Science Center using a quasi-differential method previously developed at Rensselaer Polytechnic Institute. The measurement spanned 0.82–20 MeV and 30–150 degrees. The measurements show there are a significant number of discrepancies between library predictions of the neutron yield and physical observation. A few of the main discrepancies found are described in this paper. Based on these results a new evaluation utilizing these results for carbon, 235 U, and 239 Pu is recommended.

235U↗

Characterization of 244 Cm Neutron Sources

There is a need to find a replacement for the 252 Cf sources currently used in Standards-based performance testing of neutron instrumentation. This is a result of its relatively short half-life, concerns about future availability and recent increases in cost. A potential replacement source, 244 Cm is evaluated in this study where two commercially available sources have been acquired and their neutron emission spectra measured using a pair of spectrometers. Both instruments showed the 244 Cm spontaneous neutron spectrum to be fully consistent with a MCNP6®-calculated spectrum using published Watt fission parameters for 244 Cm. In addition, the emission rate of the weaker 244 Cm source was established through a direct count rate comparison against a calibrated and similarly encapsulated 252 Cf source. The 244 Cm source emission rate was found to be in excellent agreement with value stated on the manufacturer's source certificate. It is concluded that 244 Cm would be an ideal replacement for 252 Cf based on its longer half-life (18.1 y) and its essentially identical neutron emission spectrum. In addition, 244 Cm sources are commercially available at reasonable cost.

244Cm↗

Neutron spectroscopy for pulsed beams with frame overlap using a double time-of-flight technique

A new double time-of- ight (dTOF) neutron spectroscopy technique has been developed for pulsed broad spectrum sources with a duty cycle that results in frame overlap, where fast neutrons from a given pulse overtake slower neutrons from previous pulses. Using a tunable beam at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory, neutrons were produced via thick-target breakup of 16 MeV deuterons on a beryllium target in the cyclotron vault. The breakup spectral shape was deduced from a dTOF measurement using an array of EJ-309 organic liquid scintillators. Simulation of the neutron detection efficiency of the scintillator array was performed using both GEANT4 and MCNP6. The efficiency- corrected spectral shape was normalized using a foil activation technique to obtain the energy-dependent flux of the neutron beam at zero degrees with respect to the incoming deuteron beam. The dTOF neutron spectrum was compared to spectra obtained using HEPROW and GRAVEL pulse height spectrum unfolding techniques. While the unfolding and dTOF results exhibit some discrepancies in shape, the integrated flux values agree within two standard deviations. As a result, this method obviates neutron time-of-flight spectroscopy challenges posed by pulsed beams

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗