Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Magnetic design calculation and FRC formation modeling for the field reversed experiment liner

Integrated magnetic modeling and design are important to meet the requirements for (1) formation, (2) translation, and (3) compression of a field reversed configuration (FRC) for magnetized target fusion. Off-the-shelf solutions do not exist for many generic design issues. A predictive capability for time-dependent magnetic diffusion in realistically complicated geometry is essential in designing the experiment. An eddy-current code was developed and used to compute the mutual inductances between driven magnetic coils and passive magnetic shields (flux excluder plates) to calculate the self-consistent axisymmetric magnetic fields during the first two stages. The plasma in the formation stage was modeled as an immobile solid cylinder with selectable constant resistivity and magnetic flux that was free to readjust itself. It was concluded that (1) use of experimentally obtained anomalously large plasma resistivity in magnetic diffusion simulations is sufficient to predict magnetic reconnection and FRC formation, (2) comparison of predicted and experimentally observed timescales for FRC Ohmic decay shows good agreement, and (3) for the typical range of resistivities, the magnetic null radius decay rate scales linearly with resistivity. The last result can be used to predict the rate of change in magnetic flux outside of the separatrix (equal to the back-emf loop voltage), and thus estimate a minimum {theta}-coil loop voltage required to form an FRC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effective shielding to measure beam current from an ion source

To avoid saturation, beam current transformers must be shielded from solenoid, quad, and RFQ high stray fields. Good understanding of field distribution, shielding materials, and techniques is required. Space availability imposes compact shields along the beam pipe. This paper describes compact effective concatenated magnetic shields for IFMIF-EVEDA LIPAc LEBT and MEBT and for FAIR Proton Linac injector. They protect the ACCT Current Transformers beyond 37 mT radial external fields. Measurements made at Saclay on the SILHI source are presented.

43 PARTICLE ACCELERATORS↗

A simplified HTc rf SQUID to analyze the human cardiac magnetic field

We have developed a four-channel high temperature radio-frequency superconducting quantum interference device (HT{sub c} rf SQUID) in a simple magnetically shielded room (MSR) that can be used to analyze the cardiac magnetic field. It is more robust and compact than existing systems. To achieve the high-quality magnetocardiographic signal, we explored new adaptive software gradiometry technology constructed by the first-order axial gradiometer with a baseline of 80mm, which can adjust its performance timely with the surrounding conditions. The magnetic field sensitivity of each channel was less than 100fT/√Hz in the white noise region. Especially, in the analysis of MCG signal data, we proposed the total transient mapping (TTM) technique to visualize current density map (CDM), then we focused to observe the time-varying behavior of excitation propagation and estimated the underlying currents at T wave. According to the clear 3D imaging, isomagnetic field and CDM, the position and distribution of a current source in the heart can be visualized. It is believed that our four-channel HT{sub c} rf SQUID magnetometer based on biomagnetic system is available to detect MCG signals with sufficient signal-to-noise (SNR) ratio. In addition, the CDM showed the macroscopic current activation pattern, in a way, it has established strong underpinnings for researching the cardiac microscopic movement mechanism and opening the way for its use in clinical diagnosis.

36 MATERIALS SCIENCE↗

Study of Permanent Magnet Focusing for Astronomical Camera Tubes

A design is developed of a permanent magnet assembly (PMA) useful as the magnetic focusing unit for the 35 and 70 mm (diagonal) format SEC tubes. Detailed PMA designs for both tubes are given, and all data on their magnetic configuration, size, weight, and structure of magnetic shields adequate to screen the camera tube from the earth's magnetic field are presented. A digital computer is used for the PMA design simulations, and the expected operational performance of the PMA is ascertained through the calculation of a series of photoelectron trajectories. A large volume where the magnetic field uniformity is greater than 0.5% appears obtainable, and the point spread function (PSF) and modulation transfer function(MTF) indicate nearly ideal performance. The MTF at 20 cycles per mm exceeds 90%. The weight and volume appear tractable for the large space telescope and ground based application.

Long, D. C.↗

Space applications of superconductivity - Low frequency superconducting sensors

Although this paper deals with several low-frequency instruments and devices, most of the discussion relates to SQUID (Superconducting QUantum Interference Device) magnetometers and gradiometers, since these are perceived as the instruments with the greatest potential for space applications. The discussion covers SQUID for magnetic field measurements; present state of the art of SQUID technology; ultimate potential performance; applications to magnetic measurements in space; SQUID galvanometers, voltage and current sensors, and wide-band amplifiers; magnetic shielding, and superconducting dc transformer. SQUIDS are superior to all other magnetic sensors in sensitivity, frequency response, range, and linearity. It is suggested that SQUID instruments, both magnetometers and gradiometers, would be valuable in studies of the dynamics of interplanetary and planetary fields. SQUID gradiometers are useful for detection and mapping of magnetic anomalies at short to moderate ranges.

Zimmerman, J. E.↗

Extended linear ion trap frequency standard apparatus

A linear ion trap for frequency standard applications is provided with a plurality of trapping rods equally spaced and applied quadruple rf voltages for radial confinement of atomic ions and biased level pins at each end for axial confinement of the ions. The trapping rods are divided into two linear ion trap regions by a gap in each rod in a common radial plane to provide dc discontinuity, thus dc isolating one region from the other. A first region for ion-loading and preparation fluorescence is biased with a dc voltage to transport ions into a second region for resonance frequency comparison with a local oscillator derived frequency while the second region is held at zero voltage. The dc bias voltage of the regions is reversed for transporting the ions back into the first region for fluorescence measurement. The dual mode cycle is repeated continuously for comparison and feedback control of the local oscillator derived frequency. Only the second region requires magnetic shielding for the resonance function which is sensitive to any ambient magnetic fields.

Prestage, John D.↗

New Limit on the Permanent Electric Dipole Moment of 129 Xe Using 3 He Comagnetometry and SQUID Detection

We report results of a new technique to measure the electric dipole moment of 129 Xe with 3 He comagnetometry. In this work, both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is d A ( 129 Xe) = 1.4 ± 6.6 stat ± 2.0 syst ) × 10 –28 e cm. This corresponds to an upper limit of |d A ( 129 Xe)| < 1.4 × 10 –27 e cm (95% C.L.), a factor of 5 more sensitive than the limit set in 2001.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetically Attached Multifunction Maintenance Rover

A versatile mobile telerobot, denoted the magnetically attached multifunction maintenance rover (MAGMER), has been proposed for use in the inspection and maintenance of the surfaces of ships, tanks containing petrochemicals, and other large ferromagnetic structures. As its name suggests, this robot would utilize magnetic attraction to adhere to a structure. As it moved along the surface of the structure, the MAGMER would perform tasks that could include close-up visual inspection by use of video cameras, various sensors, and/or removal of paint by water-jet blasting, laser heating, or induction heating. The water-jet nozzles would be mounted coaxially within compressed-air-powered venturi nozzles that would collect the paint debris dislodged by the jets. The MAGMER would be deployed, powered, and controlled from a truck, to which it would be connected by hoses for water, compressed air, and collection of debris and by cables for electric power and communication (see Figure 1). The operation of the MAGMER on a typical large structure would necessitate the use of long cables and hoses, which can be heavy. To reduce the load of the hoses and cables on the MAGMER and thereby ensure its ability to adhere to vertical and overhanging surfaces, the hoses and cables would be paid out through telescopic booms that would be parts of a MAGMER support system. The MAGMER would move by use of four motorized, steerable wheels, each of which would be mounted in an assembly that would include permanent magnets and four pole pieces (see Figure 2). The wheels would protrude from between the pole pieces by only about 3 mm, so that the gap between the pole pieces and the ferromagnetic surface would be just large enough to permit motion along the surface but not so large as to reduce the magnetic attraction excessively. In addition to the wheel assemblies, the MAGMER would include magnetic adherence enhancement fixtures, which would comprise arrays of permanent magnets and pole pieces that could be adjusted to maximize or minimize the overall attractive magnetic force. Even with a paint thickness of 2 mm, a preliminary design provides a safety factor of 5 in the magnetic force in the upside- down, water-jets-operating condition, in which the total load (including the weight of the MAGMER and cables and the water-jet force) would be about 260 lb (the weight of 118 kg). Optionally, the MAGMER could carry magnetic shielding and/or could be equipped with a demagnetizing module to remove residual magnetism from the structure. The MAGMER would carry four charge-coupled-device cameras for visual inspection, monitoring of operation, navigation, and avoidance of collisions with obstacles. The control system of the MAGMER would include navigation and collision-avoidance subsystems that would utilize surface features as landmarks, in addition to direct images of obstacles.

Bar-Cohen, Yoseph↗

HERMeS Thruster Magnetic Field Topology Optimization Study: Plasma Plume Results

NASA’s Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5-kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. The magnetic optimization study aims to explore and investigate alternate magnetic field topologies. Four candidate magnetic field topologies that reduce the effectiveness of the shielding along the discharge channel walls with the intent to also reduce the erosion rates along the front pole covers were designed. Three of the four candidate magnetic field topologies (B1, B2, and B4) have been manufactured and were subjected to an extensive test campaign that included laser induced fluorescence (LIF), performance, stability, wear, and plume characterization. In Phase I, LIF measurements along the discharge chamber centerline found that upstream retraction of the thruster’s peak magnetic field does result in an upstream shift of the acceleration zone, but the magnitude of the shift does not correspond one-to-one to the shift in the location of the peak radial magnetic field magnitude. Phase II test segment results found that at a normalized thruster magnetic field setting of 1, the thruster performance and discharge current oscillations were very similar for configurations B0-B2. Also in Phase II abbreviated wear tests found that average inner front pole cover erosion rates for configuration B1 were approximately 65% of those at B0, and the average erosion rates for configuration B2 were approximately 35% of those at B0. This paper reports on the detailed plasma plume mapping results for configurations B0-B4. Faraday probe results indicate that, at 600 V operation, the plume divergence increased slightly for the B4 configuration when compared to B0-B2. Wien filter spectrometer results found that at 600 V, lower multiply-charged species fractions were attained as the thruster transitioned from configurations B0 to B4. Finally, retarding potential analyzer results found that at 600 V operation and at angles above 60,˚ significantly lower high-energy ion content was found for configurations B2 and B4 when compared to B0 and B1.

Electric propulsion,.Hall thruster, laser diagnost↗

A General Model for the Ductility of Intermetallics Applied to Fe-Co Alloys

The mechanical properties, specifically ductility, of high performing soft magnets such as Fe-Co alloys are a limiting factor to their broader use in a number of systems. The understanding of the mechanical robustness in these materials is currently insufficient to be able to support the growing interest in applications such as magnetic shielding or electric motors. Fe-Co alloys provide the highest commercially available magnetic saturation and high magnetic permeability but have very poor ductility. The addition of vanadium to these alloys has allowed for significant commercialization and some ductility improvements, but the fundamental reasons for the observed improvements are not well understood. In most published work on mechanical properties in these alloys, the precise chemistry of the alloys investigated, often a critical aspect of intermetallics, is not reported or controlled and thermal history is unclear. This work creates a ductility model that is sensitive to changes in chemistry and can predict relative strain to failure as well as brittle fracture mode for intermetallics and is applied to Fe-Co alloys. Through the application of density functional theory (DFT), this model identifies defect stabilities, anti-phase boundary (APB) energies, the energy necessary to cross-slip, and cleavage energies and combines them through energetic competition to determine a relative failure strain. The model correctly predicts ductility improvements with the addition of vanadium as well as the transition from intergranular to transgranular cleavage, though more precise experiments are necessary to appropriately validate the various improvements observed.

36 MATERIALS SCIENCE↗

Superconducting transition temperatures in the electronic and magnetic phase diagrams of Sr 2 VFeAsO 3- δ , a superconductor

We elucidate the magnetic phases and superconducting (SC) transition temperatures (T c) in Sr 2 VFeAsO 3-δ (21113V), an iron-based superconductor with a thick-blocking layer fabricated from a perovskite-related transition metal oxide. At low temperatures (T<37.1 K), 21113V exhibited a SC phase in the range 0.031 ≤ δ ≤ 0.145 and an antiferromagnetic (AFM) iron sublattice in the range 0.267 ≤ δ ≤ 0.664. Mixed-valent vanadium exhibited a dominant AFM phase in 0.031 ≤ δ ≤ 0.088, and a partial ferrimagnetic (Ferri.) phase in the range 0.124 ≤ δ ≤ 0.664. The Ferri. phase was the most dominant at a δ value of 0.267, showing an AFM phase of Fe at T < 20 K. Increasing the spontaneous magnetic moments reduced the magnetic shielding volume fraction due to the SC phase. This result was attributed to the magnetic phase of vanadium, which dominates the superconductivity of Fe in 21113V. The T c–δ curve showed two maxima. Conclusively, the smaller and larger of T c maxima occurred at δ = 0.073 and δ = 0.145, respectively; the latter resides on the phase boundary between AFM and the partial Ferri. phases of vanadium. 21113V is a useful platform for verifing new mechanisms of T c enhancement in iron-based superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DHS Written Report

Recently, a new galactic cosmic-ray (GCR) source option [1] was implemented in the all-energy, all-particle transport code MCNP6 [2]. In this paper, we made use of this feature to calculate surface neutron and photon background fluxes on a terrestrial grid around the earth. These spectra have been incorporated into Release 2 of the 'background.dat' file, which is read and sampled by MCNP6 whenever a user invokes the background source option [2]. Cosmic radiation bombards Earth with various particles, such as protons and {alpha} particles, some of which are deflected by the Earth's shielding magnetic field. Particles that carry sufficient energy can overcome the deflection and penetrate into the atmosphere. The sufficient energy is dependent on the terrestrial coordinates due to the magnetic force's proportionality to the sine of the angle between the velocity vector of the incoming particle and the magnetic field. As the particles propagate through the atmosphere, collisions with atmospheric molecules generate new particles such as neutrons, protons, photons, muons, pions, and other exotic particles. These secondary often have sufficient energy to undergo additional nuclear interactions, and so on, forming what is known as a cascade shower. The tabulation of background particle fluxes on the surface of the earth is important for a variety of reasons, one of which is the design of nuclear material detection systems. The simulations used various models and formulations for the cosmic source spectra, atmosphere, and terrestrial conditions to correctly model the propagation of GCR particles through the atmosphere to surface level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hall Thruster with Magnetic Discharge Chamber and Conductive Coating

Hall thrusters with conductive coatings are disclosed. A Hall thruster comprises magnetic shielding in order to avoid collisions with the inner walls of its discharge chamber. By removing the source of erosion, the walls of the chamber can be removed reducing mass, cost and complexity of the thruster. A conductive coating, such as an aluminum coating, is deposited on inner screens between the discharge chamber and the magnetic poles of the thruster. The magnetic field within the chamber shields the conductive coating deposited on the inner and outer screens of the chamber.

Goebel, Dan Michael↗

Soft-Robotic Rover with Electrodynamic Power Scavenging: NIAC Final Report - Phase 1

The purpose of studying the capabilities of Electrodynamic Tethers (EDT) and Soft Robotics is to ascertain the feasibility of using cross-cutting EDT and soft robotics technologies to achieve future NASA mission objectives with mass and power budgets orders of magnitude lower than conventional spacecraft. In this context, the Phase I study focuses on three technological elements: the design of a soft-robotic rover that can operate in extraterrestrial oceans, demonstrating feasibility of electrodynamic tethers for power scavenging in the Europa environment, and utilizing electrolysis to power biomimetic propulsion.The Phase I results show that a soft robotic, underwater rover has many advantages over a traditional view of autonomous underwater vehicles. Many of these advantages stem from its ability to collapse or expand the body, which carries two key benefits: (i) cost savings in transport and (ii) buoyancy control. Furthermore, this rover's material offers properties that enable it to survive most oceanic conditions, withstand a likely radiation environment, and retard ice formation. The use of these soft robots under water is very attractive because buoyancy enables very large robots without the need for skeletal structures that limit their shape-changing ability. The prime limitation of soft robots for underwater exploration is their nascent state of development, an issue that this study has begun to address and that we hope to continue in Phase II. The theoretical calculations and experimental investigation on electrodynamic tethers discussed in this report show that their use in saltwater environments is feasible. However, magneto hydrodynamic effects require attention, which will be a priority in Phase II. A possible approach involves magnetic shielding of a portion of the EDT array to generate significant current from imposed alternating magnetic fields. The Phase I experiments show that this approach may enable enough power to be generated for a soft robotic rover of the scale contemplated here. This power is in the range of 1mW to 1W and determines the time required to collect and transmit science data.

Soft Robotics↗

TU-H-BRA-07: Design, Construction, and Installation of An Experimental Beam Line for the Development of MRI-Linac Compatible Electron Accelerator

Purpose: MRI guided radiation therapy (MRIgRT) is a rapidly growing field; however, Linac operation in MRI fringe fields represents an ongoing challenge. We have previously shown in-silico that Linacs could be redesigned to function in the in-line orientation with no magnetic shielding by adopting an RF-gun configuration. Other authors have also published insilico studies of Linac operation in magnetic fields; however to date no experimental validation data is published. This work details the design, construction, and installation of an experimental beam line to validate our in-silico results. Methods: An RF-gun comprising 1.5 accelerating cells and capable of generating electron energies up to 3.2MeV is used. The experimental apparatus was designed to monitor both beam current (toroid current monitor), spot size (two phosphor screens with viewports), and generate peak magnetic fields of at least 1000G (three variable current electromagnetic coils). Thermal FEM simulations were developed to ensure coil temperature remained within 100degC. Other design considerations included beam disposal, vacuum maintenance, radiation shielding, earthquake safety, and machine protection interlocks. Results: The beam line has been designed, built, and installed in a radiation shielded bunker. Water cooling, power supplies, thermo-couples, cameras, and radiation shielding have been successfully connected and tested. Interlock testing, vacuum processing, and RF processing have been successfully completed. The first beam on is expected within weeks. The coil heating simulations show that with care, peak fields of up to 1200G (320G at cathode) can be produced using 40A current, which is well within the fields expected for MRI-Linac systems. The maximum coil temperature at this current was 84degC after 6 minutes. Conclusion: An experimental beam line has been constructed and installed at SLAC in order to experimentally characterise RF gun performance in in-line magnetic fields, validate in-silico design work, and provide the first published experimental data relating to accelerator functionality for MRIgRT.

43 PARTICLE ACCELERATORS↗

Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5 m × 2.5 m × 3 m, disturbances of the magnetic field are attenuated by factors of 5–50 at a bandwidth from 10{sup −3} Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the neutron electric dipole moment measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of Local Magnetic Fields in Actinide Tetrafluorides

Fluorine-19 magnetic shielding tensors have been measured in a series of actinide tetrafluorides (AnF4) by solid state nuclear magnetic resonance (NMR) spectroscopy. Tetravalent actinide centers with 0 to 8 valence electrons can form tetrafluorides with the same unit cell, making these compounds an attractive choice for a systematic study of the variation in electronic structure across the 5f row of the Periodic Table. Pronounced deviations from predictions based on localized valence electron models have been detected by these experiments, which suggests that this approach may be used as a quantitative probe of electronic correlations.

Walter, Eric D.↗

Eddy Current Method for Fatigue Testing

Flux-focusing electromagnetic sensor using a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material. A ferrous shield isolates a high-turn pick-up coil from an excitation coil. Use of the magnetic shield produces a null voltage output across the receiving coil in presence of an unflawed sample. Redistribution of the current flow in the sample caused by the presence of flaws. eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. Maximum sensor output is obtained when positioned symmetrically above the crack. By obtaining position of maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. Accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output resulting in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip enabling the search region to be clearly defined. Under low frequency operation, material thinning due to corrosion causes incomplete shielding of the pick-up coil. Low frequency output voltage of the probe is therefore a direct indicator of thickness of the test sample. Fatigue testing a conductive material is accomplished by applying load to the material, applying current to the sensor, scanning the material with the sensor, monitoring the sensor output signal, adjusting material load based on the sensor output signal of the sensor, and adjusting position of the sensor based on its output signal.

Simpson, John W.↗