Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low temperature detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Advanced detectors and signal processing for bubble memories

The feasibility of combining silicon and magnetic bubble technologies is demonstrated. Results of bubble film annealing indicate that a low temperature silicon on garnet technology is the most likely one to succeed commercially. Annealing ambients are also shown to have a major effect on the magnetic properties of bubble films. Functional MOSFETs were fabricated on bubble films coated with thick (approximately 1 micron) SiO2 layers. The two main problems with these silicon on garnet MOSFETs are low electron mobilities and large gate leakage currents. Results indicate that the laser recrystallized silicon and gate oxide (SiO2) layers are contaminated. The data suggest that part of the contaminating ions originate in the sputtered oxide spacer layer and part originates in the bubble film itself. A diffusion barrier, such as silicon nitride, placed between the bubble film and the silicon layer should eliminate the contamination induced problem.

Kryder, M. H.↗

Use of Diffusion Bonded Cu Strap and Integrated MLI for Thermal Control of 100 K IR Detector on L’Ralph Instrument

Passive cooling of cryogenic instruments is one of the most challenging aspects of spaceflight thermal control systems. They are highly sensitive to parasitic heat leaks from their warmer environment, especially the spacecraft components. The L’Ralph instrument on the Lucy mission is an example of such a system, with its LEISA detector requiring passive cooling to temperatures below 112 K. MLI performance can be measured in terms of estar, and analysts apply bias between a high and low estar value. This approach works well for conventional MLI at room temperature, however, it can be dangerous when a mission goes through a wide range of temperatures during its lifetime, with estar values increasing exponentially as temperatures get colder. Various estar correlations are presented as well as how L’Ralph is approaching the MLI problem with the use of IMLI. IMLI uses discrete spacers to isolate each layer, and doesn’t require intermediate layers such as dacron netting. This results in estar performance that can be more precisely estimated, and yields valuesaround 0.004 at the 112K operating temperature. L’Ralph is using IMLI on the backside of the radiator, which permits a more effective use of increased radiator area, by minimizing the area dependent heat leak impact from the instrument backloading. The detector is thermally coupled to the radiator via a diffusion bonded Cu strap. The diffusion bonding process chemically bonds the Cu foil ends in order to maximize heat transfer effectiveness across the multiple foils used. Employing a pressure compensation design via the use of Ti blocks and a clamp at the strap ends ensures that as temperatures go colder, pre-load is maintained in order to minimize resistance at the strap ends. The use of both of these technologies, and how they work together are crucial to the success of the L’Ralph thermal control system.

Thermal↗

Bolometric detection of neutrinos

Elastic neutrino scattering off electrons in crystalline silicon at 1-10 mK results in measurable temperature changes in macroscopic amounts of material, even for low-energy (less than 0.41-MeV) pp neutrinos from the sun. New detectors for bolometric measurement of low-energy neutrino interactions, including coherent nuclear elastic scattering, are proposed. A new and more sensitive search for oscillations of reactor antineutrinos is practical (about 100 kg of Si), and would lay the groundwork for a more ambitious measurement of the spectrum of pp, Be-7, and B-8 solar neutrinos, and of supernovae anywhere in the Galaxy (about 10 tons of Si).

Cabrera, B.↗

Plasma Treatment to Remove Carbon from Indium UV Filters

The sounding rocket experiment FIRE (Far-ultraviolet Imaging Rocket Experiment) will improve the science community fs ability to image a spectral region hitherto unexplored astronomically. The imaging band of FIRE (.900 to 1,100 Angstroms) will help fill the current wavelength imaging observation hole existing from approximately equal to 620 Angstroms to the GALEX band near 1,350 Angstroms. FIRE is a single-optic prime focus telescope with a 1.75-m focal length. The bandpass of 900 to 1100 Angstroms is set by a combination of the mirror coating, the indium filter in front of the detector, and the salt coating on the front of the detector fs microchannel plates. Critical to this is the indium filter that must reduce the flux from Lymanalpha at 1,216 Angstroms by a minimum factor of 10(exp -4). The cost of this Lyman-alpha removal is that the filter is not fully transparent at the desired wavelengths of 900 to 1,100 Angstroms. Recently, in a project to improve the performance of optical and solar blind detectors, JPL developed a plasma process capable of removing carbon contamination from indium metal. In this work, a low-power, low-temperature hydrogen plasma reacts with the carbon contaminants in the indium to form methane, but leaves the indium metal surface undisturbed. This process was recently tested in a proof-of-concept experiment with a filter provided by the University of Colorado. This initial test on a test filter showed improvement in transmission from 7 to 9 percent near 900 with no process optimization applied. Further improvements in this performance were readily achieved to bring the total transmission to 12% with optimization to JPL's existing process.

Greer, Harold F.↗

Excimer laser processing of backside-illuminated CCDS

An excimer laser is used to activate previously implanted dopants on the backside of a backside-illuminated CCD. The controlled ion implantation of the backside and subsequent thin layer heating and recrystallization by the short wavelength pulsed excimer laser simultaneously activates the dopant and anneals out implant damage. This improves the dark current response, repairs defective pixels and improves spectral response. This process heats a very thin layer of the material to high temperatures on a nanosecond time scale while the bulk of the delicate CCD substrate remains at low temperature. Excimer laser processing backside-illuminated CCD's enables salvage and utilization of otherwise nonfunctional components by bringing their dark current response to within an acceptable range. This process is particularly useful for solid state imaging detectors used in commercial, scientific and government applications requiring a wide spectral response and low light level detection.

Russell, S. D.↗

Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The discovery of a new class of ceramic superconductors with transition temperatures above the boiling point of liquid nitrogen has opened the doors for several space applications. One important space application is the fabrication of an electrically conducting and thermally isolating link to replace manganin wires used in connecting IR detectors to data acquisition electronics on remote sensing platforms like SAFIRE and SIRTF. These NASA platforms designed to monitor the earth's atmosphere from space use infrared detectors which operate at liquid helium temperature (4.2K) for optimum performance. The SAFIRE mission employs hybrid dewars which combine both mechanical and cryogenic liquid cooling. The lifetime of such a mission is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). Currently these remoter sensing systems use manganin wires to connect the IR detectors to the data acquisition electronics. This link between a detector operating at 4 K and electronics operating at 80 K must be made of material that has high electrical conductivity and high thermal resistance. The YBCO superconductor with a transition temperature, Tc, of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. The fabrication of an electrically conducting and thermally isolating link that replaces the manganin wires is an important application that will improve thermal isolation of IR detectors and will increase the lifetime of the cryogen. The link is made by screen printing superconducting lines on a low thermal conductivity ceramic substrate. Developing, modeling, and testing this high temperature superconducting link is a collaborative effort among NASA-Langley Research Center, Christopher Newport University (CNU), Clemson University and the industrial companies that have joined the Commercialization of Space Program for the purpose of developing and testing this link. CNU's effort in the development of this superconducting link included the following major efforts: (1) Development of a thermal conductivity measurement system for high temperature superconductors and ceramic materials which are potential candidates for use as substrates in this link. (2) Development of a mathematical model for the superconducting link that studies the effect of materials and geometry on the heat load and life time of missions. (3) Characterization of high Tc materials and assemblies made for space applications. Properties studied include humidity effects and aging effects on high Tc materials. This report summarizes the results of the research studies that were completed. Copies of publications detailing these findings are attached to this report.

Selim, Raouf R.↗

Apparatus for trapping and thermal detection of atomic hydrogen in high magnetic fields at low temperatures

An apparatus is described in which hydrogen atoms were trapped at temperatures down to 1.1 K in the 11 T field of a large volume superconducting magnet. A high sensitivity thermal detector was used to study trapping and recombination of atoms on the detector surface. The apparatus permits the application of extremely high steady state magnetic fields to study the potential effects of electron spin polarization on the stabilization of hydrogen atoms.

Woollam, J. A.↗

Conceptual study of a two-layer silicon pixel detector to tag the passage of muons from cosmic sources through quantum processors

Abstract Recent studies in quantum computing have shown that quantum error correction with large numbers of physical qubits are limited by ionizing radiation from high-energy particles. Depending on the physical setup of the quantum processor, the contribution of muons from cosmic sources can constitute a significant fraction of these interactions. As most of these muons are difficult to stop, we perform a conceptual study of a two-layer silicon pixel detector to tag their hits on a solid-state quantum processor instead. With a typical dilution refrigerator geometry model, we find that efficiencies greater than 50% are most likely to be achieved if at least one of the layers is operated at the deep-cryogenic (<1 K) flanges of the refrigerator. Following this finding, we further propose a novel research program that could allow the development of silicon pixel detectors that are fast enough to provide input to quantum error correction algorithms, can operate at deep-cryogenic temperatures, and have very low power consumption.

Instruments & Instrumentation↗

Gold absorbing film for a composite bolometer

The principles governing the design of metal films are reviewed, with attention also given to the choice of metals. A description is then given of the characteristics of a bolometer with a gold absorbing film. It is demonstrated that gold is effective as an absorbing film for a millimeter bolometer operated at 1.5 K. At 1.5 K, gold is significantly better than bismuth since gold has a lower heat capacity for the absorbing film. At 0.3 K, gold and bismuth are both suitable. It is pointed out that at temperatures below 0.3 K, a superconducting absorbing film can have a heat capacity low enough not to dominate the heat capacity of the detector; for this reason, it may give better performance than a nonsuperconducting absorbing film.

Dragovan, M.↗

A mosaic infrared sensor for space astronomy, phase 3

Short wavelength (1 to 3 micron) HgCdTe mosaic detector arrays for space astronomy purposes were fabricated and studied. Honeywell will test and analyze these arrays at moderate temperatures (300-130K). Low temperature testing will be performed at the University of Hawaii. Short wavelength mosaic arrays were fabricated on three wafers and one array from each wafer was tested and analyzed. The p-type base carrier concentration on these wafers was an order of magnitude lower than typically used so far on this program (10 to the 14/cc as compared to 10 to the 15/cc). Tunneling currents are expected to decrease with this decrease in carrier concentration, resulting in improved performance at very low temperatures. The risk with such a low carrier concentration is that fixed charge in the surface passivating layer must be carefully controlled to prevent surface inversion layers.

Sood, A. K.↗

Image plane detector spectrophotometer - Application to O2 atmospheric band nightglow

A new variety of low resolution spectrometer is described. This device, an image plane detector spectrophotometer, has high sensitivity and modest resolution sufficient to determine the rotational temperature and brightness of molecular band emissions. It uses an interference filter as a dispersive element and a multichannel image plane detector as the photon collecting device. The data analysis technqiue used to recover the temperature of the emitter and the emission brightness is presented. The atmospheric band of molecular oxygen is used to illustrate the use of the device.

Luo, Mingzhao↗

Dual Transition Edge Sensor Bolometer for Enhanced Dynamic Range

Broadband surveys at the millimeter and submillimeter wavelengths will require bolometers that can reach new limits of sensitivity and also operate under high background conditions. To address this need, we present results on a dual transition edge sensor (TES) device with two operating modes: one for low background, ultrasensitive detection and one for high background, enhanced dynamic range detection. The device consists of a detector element with two transition temperatures (T(sub c)) of 0.25 and 0.51 K located on the same micromachined, thermally isolated membrane structure. It can be biased on either transition, and features phonon-limited noise performance at the lower T(sub c). We measure noise performance on the lower transition 7 x 10(exp -18) W/rt(Hz) and the bias power on the upper transition of 12.5 pW, giving a factor of 10 enhancement of the dynamic range for the device. We discuss the biasable range of this type of device and present a design concept to optimize utility of the device.

Chervenak, J. A.↗

Carbon nanotube Schottky diodes using Ti-Schottky and Pt-ohmic contacts for high frequency applications

We have demonstrated Schottky diodes using semiconducting single-walled nanotubes (s-SWNTs) with titanium Schottky and platinum Ohmic contacts for high-frequency applications. The diodes are fabricated using angled evaporation of dissimilar metal contacts over an s-SWNT. The devices demonstrate rectifying behavior with large reverse bias breakdown voltages of greater than 15 V. To decrease the series resistance, multiple SWNTs are grown in parallel in a single device, and the metallic tubes are burnt-out selectively. At low biases these diodes showed ideality factors in the range of 1.5 to 1.9. Modeling of these diodes as direct detectors at room temperature at 2.5 terahertz (THz) frequency indicates noise equivalent powers (NEP) potentially comparable to that of the state-of-the-art gallium arsenide solid-state Schottky diodes, in the range of 10-13 W(square root)xHz.

semiconducting↗

Fabrication of sensitive high Tc bolometers

The rapid change of resistance with temperature of high quality films of high T sub c superconductors can be used to make resistance thermometers with very low temperature noise. Measurements on c-axis yttrium barium copper oxide (YBCO) films have given a spectral intensity of temperature noise less than 4 times 10(exp -8) K/Hz(exp 1/2) at 10 Hz. Consequently, the opportunity exists to make useful bolometric infrared detectors that operate near 90 K which can be cooled with liquid nitrogen. The fabrication and measurement of two bolometer architectures are discussed. The first is a conventional bolometer which consists of a 3000 A thick YBCO film deposited in situ by laser ablation on top of a 500 A thick SrTiO3 thickness and diced into 1x1 mm(exp 2) bolometer chips. Gold black smoke was used as the radiation absorber. The voltage noise was less than the amplifier noise when the film was current biased. Optical measurements gave an NEP of 5 times 10(exp -11) W/Hz(exp 1/2) at 10 Hz. The second architecture is that of an antenna-coupled microbolometer which consists of a small (5x10 cubic microns) YBCO film deposited directly on a bulk substrate with a low thermal conductance (YSZ) and an impedance matched planar lithographed spiral or log-periodic antenna. This structure is produced by standard photolithographic techniques. Measurements gave an electrical NEP of 4.7 times 10(exp -12) W/Hz(exp 1/2) at 10 kHz. Measurements of the optical efficiency are in progress. The measured performance of both bolometers will be compared to other detectors operating at or above liquid nitrogen temperatures so as to identify potential applications.

Nahum, Michael↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

Elemental boron-doped p(+)-SiGe layers grown by molecular beam epitaxy for infrared detector applications

SiGe/Si heterojunction internal photoemission (HIP) detectors have been fabricated utilizing molecular beam epitaxy of p(+)-SiGe layers on p(-)-Si substrates. Elemental boron from a high-temperature effusion cell was used as the dopant source during MBE growth, and high doping concentrations have been achieved. Strong infrared absorption, mainly by free-carrier absorption, was observed for the degenerately doped SiGe layers. The use of elemental boron as the dopant source allows a low MBE growth temperature, resulting in improved crystalline quality and smooth surface morphology of the Si(0.7)Ge(0.3) layers. Nearly ideal thermionic emission dark current characteristics have been obtained. Photoresponse of the HIP detectors in the long-wavelength infrared regime has been demonstrated.

Lin, T. L.↗

Three-dimensional reconstruction of implosion stagnation in laser direct drive on OMEGA

Multidimensional effects on hot-spot formation must be considered to better understand the current limits on the performance of direct-drive inertial confinement fusion experiments on OMEGA with cryogenically layered solid deuterium–tritium targets. A comprehensive reconstruction effort has been established at the Laboratory for Laser Energetics to infer hot-spot and shell conditions at stagnation from a large collection of x-ray, neutron, and particle detectors along multiple lines of sight. Several time-gated and time-integrated x-ray imagers are being used to record the shape of the hot-spot plasma. A 3D hot-spot x-ray emission tomography technique has been developed to infer low-mode drive asymmetries from the hot-spot shape. A suite of neutron diagnostics is used to provide measurements of hot-spot flow velocity, ion temperature, and areal density. Here, the information obtained from the x-ray and neutron detectors will be combined into a coherent model of the shape of the hot spot and shell assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗