Bid-DS-data-model (Demand Side Bidding Data Model) [SWR-22-80]
A model structure to support representation of power system dispatching for optimal power flow that includes bid-in demands for load. Used to support the ARPA-E GO-3 competition.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A model structure to support representation of power system dispatching for optimal power flow that includes bid-in demands for load. Used to support the ARPA-E GO-3 competition.
With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.
The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.
This poster presents a hierarchical control framework for a virtual power plant that leverages behind-the-meter resources for grid services while maintaining customer privacy during setpoint disaggregation. Unlike many existing approaches, the virtual power plant model uses a hierarchical control strategy and an iterative approach to determine the optimal set point dis-aggregation without direct load control while maintaining system-level power flow and voltage constraints. The proposed approach is numerically validated on a synthetic distribution feeder in San Francisco, demonstrating the ability of the framework to provide privacy-preserving virtual power plant services.
A numerical wave tank approach for computational fluid dynamics (CFD) modelling of an extreme irregular seastate is presented. The technique couples a potential flow solution with a CFD solver for more efficient numerical predictions. This method has recently become attractive both for the research community and the industry working with offshore structures. The model is used to determine the response of a submerged pressure differential wave energy converter (WEC) in a fully nonlinear irregular wave condition using the high fidelity CFD code, STAR-CCM+. Potential flow based numerical models are commonly used to predict motions and performance of wave energy converters. Wave kinematics can deviate from potential flow predictions for extreme wave conditions; the excitation loads on an absorber can also be increasingly influenced by viscous effects, not captured in engineering level models. In these extreme conditions, a Reynolds-averaged Navier-Stokes CFD model can better predict motions and loads for a WEC. Long time series with varying random seed numbers can be used to identify singular extreme wave events from a stochastic irregular sea state. This approach simulates a more realistic wave series for a given sea state than a regular wave or a focused wave. However, it is computationally infeasible to run these long time series for three-dimensional (3D) CFD simulations. In this work, two-dimensional (2D) CFD simulations with a long domain allow the full development of an extreme nonlinear wave condition. The results are used to identify extreme events from a 50-year storm condition for the PacWave site off the coast of Oregon. A relatively short time window including this extreme event is then mapped to a 3D simulation using a user defined wave methodology. Convergence studies for domain length, wave forcing lengths, and time before the extreme event were conducted.
Not provided.
This submission contains raw Load Cell data and processing scripts associated with MHKDR submission 394 (UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary, DOI: 10.15473/1973860) from the University of New Hampshire and Atlantic Marine Energy Center (AMEC) turbine deployment platform. The user is directed to the MHKDR submission 394 for relevant context and detail of this deployment; see link below. The 394_READ_ME file here provides the description from that submission for quick reference. The READ_ME file for this specific instrument from the 394 submission is also available here. This submission contains a zipped folder structure containing raw data in its original format and MATLAB (2019a) processing scripts used to process and manipulate the data into its final form. The final data products are submitted in the 394 submission.
We seek to obtain a second-by-second match between the simulated and measured structural loads of a utility-scale wind turbine. To obtain the one-to-one load simulations, we start with the furthest upstream component of the modeling chain: the turbulent inflow. We consider new and existing methods to generate constrained-turbulence flow fields. The new method is based on large-eddy simulations (LES) and machine learning (ML). The existing methods include Kaimal-based TurbSim and the superstatistical wind field model. The inflow measurements used to constrain these simulations are obtained with a nacelle-mounted scanning lidar. We compare the flow fields for the different inflow simulation approaches and validate their associated load predictions against measurements collected in the Rotor Aero-dynamics, Aeroelastics, and Wake (RAAW) field campaign. We find that the rotor-position control developed for this study is key in enabling the time match between measurements and simulations. When this control approach is used, the load simulation performance tracks with the inflow simulation fidelity, with LES+ML yielding errors ≤ 4% for the damage-equivalent loads of flapwise bending moment, and tower fore-aft bending moments.
Changing power system configuration may result in load shed recovery (LSR) because topology change can provide power flow control in meshed network. Some topologies may favor generation redispatch as compared to others and can eliminate line congestion which leads to LSR. One of the known methods for topology change is called transmission switching (TS) and research conducted in the past showed that TS is an effective means of mitigating load shedding. Another method of topology control is intentional islanding (IIS). In this manuscript, we explore IIS as a potential solution for LSR. IIS based on generator coherency has been presented in literature for mitigating cascading failures. However, IIS has not been explored solely as a LSR mechanism. In this paper, we compare the LSR based on IIS with well known LSR algorithm based on TS. The comparison is performed for IEEE 39-bus system and IEEE 118- bus system. The results show that IIS has a potential to perform better than TS in terms of computational efficiency and LSR.
The self-magnetic pinch (SMP) diode is a type of radiographic diode used to generate an intense electron beam for radiographic applications. At Sandia National Laboratories, SMP was the diode load for the six-cavity radiographic integrated test stand inductive voltage adder (IVA) driver operated in a magnetically insulated transmission line (MITL). The MITL contributes a flow current in addition to the current generated within the diode itself. Extensive experiments with a MITL of 40Ω load impedance [T. J. Renk et al., Phys. Plasmas 29, 023105 (2022)] indicate that the additional flow current leads to results similar to what might be expected from a conventional high-voltage interface driver, where flow current is not present. However, when the MITL flow impedance was increased to 80 Ω, qualitatively different diode behavior was observed. This includes large retrapping waves suggestive of an initial coupling to low impedance as well as diode current decreasing with time even as the total current does not. A key observation is that the driver generates total current (flow + diode) consistent with the flow impedance of the MITL used. The case is made in this paper that the 80Ω MITL experiments detailed here can only be understood when the IVA-MITL-SMP diode is considered as a total system. Additionally, the constraint of fixed total current plus the relatively high flow impedance limits the ability of the diode (whether SMP or other type) to act as an independent load. An unexpected new result is that in tracking the behavior of the electron strike angle on the converter as a function of time, we observed that the conventional cIV x “Radiographic” radiation scaling (where x~2.2) begins to break down for voltages above 8 MV, and cubic scaling is required to recover accurate angle tracking.
The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.
Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.
The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.
A high flow differential cleaning system uses a source of pressurized compressed dry gas to pressurize a holding tank. A component to be cleaned is securely loaded and oriented against a blast plate designed specifically for the desired pressure, flow, and volume. A fast-actuated valve system opens to direct high volumes of pressurized gas from a holding tank through and around the component(s) held within the cleaning chamber for the removal of remnant powder and foreign particles from interior cavities as well as exterior component surfaces.
Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.
A triboelectric generator includes a first triboelectric member, which includes a first conductive layer and an insulating triboelectric material layer disposed on the first conductive layer. The triboelectric material layer includes a first material having a first position on a triboelectric series. An elastic member, disposed against the triboelectric material layer of the triboelectric member and includes a second conductive material, has an elasticity that results in the elastic member being deformed when compressed and returning to an original non-deformed shape after being compressed. The second conductive material has a second position on the triboelectric series. A first load is coupled to the first conductive layer and with the second conductive material so that when a force compresses the elastic member charges will flow between the first conductive layer and the second conductive layer through the load.
Wetlands represent some of the most productive ecosystems on the planet and critically influence global environmental health. Specifically, wetlands promote water quality by transforming nutrients and organic compounds and sequestering metals and contaminants. Riparian wetland hyporheic zones, where toxic surface water and anoxic groundwater mix, exhibit dynamic conditions that drive steep redox gradients and promote hotspots of diverse and fluctuating microbial activity. Changes in climate, water quality, and water quantity can disturb hydrologic flow and biogeochemical processing in these environments. Understanding how sulfate loading, impacted by hydrologic flux and anthropogenic inputs, influences iron and carbon cycling in wetlands will be crucial for predicting water quality issues driven by iron mineral precipitation and sorption, such as the release of heavy metals and other toxic elements. We used a fully integrated multi-scale and multi-method approach to develop a mechanistic understanding of how hydrologic flow influences coupled iron and sulfur cycles in riparian wetlands. This entailed hydrological, geochemical, and microbial observations at two locations: an anthropogenic sulfate-impacted riparian wetland in northern Minnesota, and a low-sulfate Fe-rich riparian wetland in Tims Branch at the Savannah River Site (SRS). These sites were characterized by hydrologically dynamic conditions where the stream and wetland systems oscillated between gaining (upward flow) and losing (downward flow) conditions that recharged the system occasionally with oxidants that fueled a variety of biogeochemical reactions. Aqueous geochemical measurements of surface water, groundwater, and porewater samples were made alongside solid-phase geochemical analyses of sediment gravity cores. Bulk X-ray absorption spectroscopy at the Advanced Photon Source (APS; Argonne) interrogated the speciation and distribution of Fe and S mineral phases of the sediments. Interestingly, it was discovered that, despite strongly reducing conditions, Fe(III) compounds and a variety of intermediate valence S compounds were stable in the subsurface. Indeed, compounds like thiosulfate, S(0), and intermediate valence organosulfur compounds were more prevalent than FeS and pyrite. The composition of the sediments did change with changes in hydrologic flow, showing their reactivity in changing redox conditions. The abundance of these intermediate S compounds was likely formed as a result of anaerobic oxidation by aqueous and solid-phase Fe(III) compounds, fueling a cryptic S cycle that is driving the breakdown of organic matter in the hyporheic zone. Microbiome surveys showed a core community that seemed stable across the landscape, but changed with increasing depth into the sediment. The community composition did not seem to change dramatically with changes in season or hydrologic flow, except for some organisms that have the potential to contribute to S cycling. More work is needed to confirm their functional activity. These fine process-scale analyses were placed within a dynamic field context using physical flow parameters from surface water and groundwater level measurements. These data helped shed light on sulfur-driven biogeochemical processes in hydrologically dynamic riparian wetlands, addressing a gap in our understanding about the impacts of pollution and other anthropogenic changes on ecologically sensitive environments.
Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.