Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid interfaces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Water at surfaces and interfaces: From molecules to ice and bulk liquid

The structure and growth of water films on surfaces is reviewed, starting from single molecules to two-dimensional wetting layers, and liquid interfaces. This progression follows the increase in temperature and vapor pressure from a few degrees Kelvin in ultra-high vacuum, where Scanning Tunneling and Atomic Force Microscopies (STM and AFM) provide crystallographic information at the molecular level, to ambient conditions where surface sensitive spectroscopic techniques provide electronic structure information. We show how single molecules bind to metal and non-metal surfaces, their diffusion and aggregation. We examine how water molecules can be manipulated by the STM tip via excitation of vibrational and electronic modes, which trigger molecular diffusion and dissociation. We review also the adsorption and structure of water on non-metal substrates including mica, alkali halides, and others under ambient humid conditions. Finally, we discuss recent progress in the exploration of the molecular level structure of solid-liquid interfaces, which impact our fundamental understanding of corrosion and electrochemical processes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

Diffuse scattering from the liquid-vapor interfaces of dilute Bi:Ga, Tl:Ga, and Pb:Ga alloys

As part of a study of the in-plane wave-vector (q{sub xy}) dependence of the effective Hamiltonian for the liquid-vapor interface, H(q), the wave-vector dependences of diffuse x-ray scattering from the liquid-vapor interfaces of dilute alloys of Bi in Ga, Tl in Ga, and Pb in Ga have been measured. In these dilute alloys the solute component segregates as a monolayer that forms the outermost stratum of the liquid-vapor interfaces, and the density distribution along the normal to the interface is stratified. Over the temperature ranges that the alloy interfaces were studied, the Tl and Pb monolayers exhibit both crystalline and liquid phases while the Bi monolayer is always liquid. The diffuse scattering from the liquid-vapor interfaces of these alloys displays interesting differences with that from the liquid-vapor interface of pure Ga. The presence of a segregated monolayer of solute in the liquid-vapor interface of the alloy appears to slightly suppress the fluctuations in an intermediate wave-vector range in a fashion that preserves the validity of the macroscopic capillary wave model to smaller wavelengths than in pure liquid Ga, and there is an increase in diffuse scattering when the Tl and Pb monolayers melt. The surface intrinsic roughness from fitting the wave-vector dependence of surface tension is 5.0 pm for the Tl:Ga alloy and 1.4 pm for the Bi:Ga alloy. Also, a mode of excitation that contributes to diffuse scattering from the liquid-vapor interface of Pb in Ga, but does not contribute to diffuse scattering from the liquid-vapor interface of Ga, has been identified. It is proposed that this mode corresponds to the separation of the Pb and Ga layers in the regime 1 nm{sup -1} {le} q{sub xy} {le} 10 nm{sup -1}.

36 MATERIALS SCIENCE↗

LIQUID AIR INTERFACE CORROSION TESTING FOR FY2010

An experimental study was undertaken to investigate the corrosivity to carbon steel of the liquid-air interface of dilute simulated radioactive waste solutions. Open-circuit potentials were measured on ASTM A537 carbon steel specimens located slightly above, at, and below the liquid-air interface of simulated waste solutions. The 0.12-inch-diameter specimens used in the study were sized to respond to the assumed distinctive chemical environment of the liquid-air interface, where localized corrosion in poorly inhibited solutions may frequently be observed. The practical inhibition of such localized corrosion in liquid radioactive waste storage tanks is based on empirical testing and a model of a liquid-air interface environment that is made more corrosive than the underlying bulk liquid due to chemical changes brought about by absorbed atmospheric carbon dioxide. The chemical changes were assumed to create a more corrosive open-circuit potential in carbon in contact with the liquid-air interface. Arrays of 4 small specimens spaced about 0.3 in. apart were partially immersed so that one specimen contacted the top of the meniscus of the test solution. Two specimens contacted the bulk liquid below the meniscus and one specimen was positioned in the vapor space above the meniscus. Measurements were carried out for up to 16 hours to ensure steady-state had been obtained. The results showed that there was no significant difference in open-circuit potentials between the meniscus-contact specimens and the bulk-liquid-contact specimens. With the measurement technique employed, no difference was detected between the electrochemical conditions of the meniscus versus the bulk liquid. Stable open-circuit potentials were measured on the specimen located in the vapor space above the meniscus, showing that there existed an electrochemical connection through a thin film of solution extending up from the meniscus. This observation supports the Hobbs-Wallace model of the development of the pitting susceptibility of carbon steel in alkaline solutions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pressurization of a Flightweight, Liquid Hydrogen Tank: Evaporation and Condensation at a Liquid Vapor Interface

Evaporation and condensation at a liquid-vapor interface is important for long-term, in-space cryogenic propellant storage. Yet the current understanding of inter-facial physics does not consistently predict behavior of evaporation or condensation rates. The proposed paper will present a physical model, based on the 1-D Heat equation and Schrage's equation, which demonstrates thin thermal layers at the fluid vapor interface.

cryogenic hydrogen↗

Behavior of ceramic particles at the solid-liquid metal interface in metal matrix composites

Directional solidification results were obtained in order to investigate particle behavior at the solid-liquid interface in Al-2 pct Mg (cellular interface) and Al-6.1 pct Ni (eutectic interface) alloys. It is found that particles can be entrapped in the solid if adequate solidification rates and temperature gradients are used. Model results showed critical velocity values slightly higher than those obtained experimentally.

Stefanescu, D. M.↗

Real-time observation of dynamic structure of liquid-vapor interface at nanometer resolution in electron irradiated sodium chloride crystals

The dynamics and structure of the liquid and vapor interface has remained elusive for decades due to the lack of an effective tool for directly visualization beyond micrometer resolution. Here, we designed a simple liquid-cell for encapsulating the liquid state of sodium for transmission electron microscopic (TEM) observation. The real-time dynamic structure of the liquid-vapor interface was imaged and videoed by TEM on the sample of electron irradiated sodium chloride (NaCl) crystals, a well-studied sample with low melting temperature and quantum super-shells of clusters. The nanometer resolution images exhibit the fine structures of the capillary waves, composed of first-time observed three zones of structures and features, i.e. flexible nanoscale fibers, nanoparticles/clusters, and a low-pressure area that sucks the nanoparticles from the liquid to the interface. Although the phenomenons were observed based on irradiated NaCl crystals, the similarities of the phenomenons to predictions suggest our real-time ovserved dynamic structure might be useful in validating long-debated theoretical models of the liquid-vapor interface, and enhancing our knowledge in understanding the non-equilibrium thermodynamics of the liquid-vapor interface to benefit future engineering designs in microfluidics.

36 MATERIALS SCIENCE↗

Project 18-15263 X-ray Studies of Interfacial Molecular Complexes in ALSEP Back-Extraction (Research Performance Final Report)

The objective of the project was to use synchrotron X-rays to measure the molecular-scale organization of extractants, complexants, buffers, and metal ions at the organic-aqueous (liquid-liquid) interface during solvent back-extraction under conditions relevant to ALSEP (Actinide-Lanthanide Separation Process). The capability of X-ray fluorescence near total reflection (XFNTR) was extended to explore the distribution of Eu(III) between the liquid-liquid interface and bulk organic and aqueous phases which contained extractants HDEHP (bis(2-ethylhexyl) phosphoric acid) and HEHEHP (2-ethylhexyl phosphonic acid mono-2-ethylhexyl ester), the complexant DTPA (diethylene triamine pentaacetic acid), and citric and nitric acids. Although an Am-compatible sample cell was developed, extending x-ray measurements of flat liquid-liquid interfaces to the actinide Am(III) did not prove to be possible within constraints imposed by the Advanced Photon Source. However, preliminary measurements with a drop cell may eventually provide a path forward to investigate Am(III) at a liquid interface. It was also demonstrated that competitive binding that occurs during back-extraction of lanthanide ions to either a phosphoric acid extractant (DHDP, di-hexadecyl phosphate) at the liquid interface or to complexant DTPA in the bulk aqueous phase could be reversibly tuned by X-ray exposure. Separately, X-ray measurements from the liquid-vapor interface explored the role of the aqueous solubility of HDEHP and HEHEHP and their interactions with a range of lanthanides and transition metal ions. Finally, the capability of X-ray absorption spectroscopy (EXAFS) was extended to probe metal ion coordination in lanthanide ion-extractant complexes at the liquid-vapor interface. Complementary to the specific interfacial systems studied during this project, the development of x-ray techniques expands our ability to understand ion ordering at liquid interfaces.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗