Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Light-Emitting Diodes (LED) for Primary Animal Habitat Lighting in Highly Controlled Environments

Significant alterations in Biological Clock responses have been reported following sidereal time changes (e.g., Jet-lag), and exposure to microgravity (e.g., daytime sleepiness). Additionally, light reduces circulating melatonin (spectral specificity greatest between 450-500 nm). It was hypothesized that LEDs can replace the current light sources used in zero gravity and terrestrial research laboratories because of their small size, low mass, low energy consumption and long functional life. This report evaluates the capacity of LEDs to entrain the circadian system of rats as judged by measurement of overt behavioral circadian rhythms (activity, feeding, drinking). These data were collected in highly controlled environments similar to the shuttle Animal Enclosure Modules. Two groups were compared: control - animals exposed to standard cool-white fluorescent lights, and test - animals exposed to LEDs with a spectral power distribution matching the fluorescent lights. Gross locomotor activity, feeding and drinking frequencies were continuously monitored and stored at 10 minute intervals. Animals were exposed to the following photoperiods: 28 days of 12L:12D, 19 days of 24L:0D and 16 days of 12L:12D. Light intensities tested varied between 0.1 to 100 lux. Rats received food and water ad libitum, and temperature and humidity were controlled throughout the study. The general health status of all rats was acceptable for each day of this study. No incidents of aggressive behavior were observed. Growth, locomotor activity, food and water consumption were comparable for all groups of animals, i.e, the circadian characteristics of the animals under these conditions were comparable. These results indicate that LED arrays are as effective in maintaining circadian rhythm stability as the commonly used cool-white fluorescent light sources. LEDs with their flexible spectrum, low energy requirements and minimal heat production have advantages for some chronopharmacology studies and for microgravity animal habitats.

Winget, C. M.↗

Active Wide-Field Sky Simulator Design for the JPL Astrometry Testbed

Exoplanet detection through astrometry will provide mass measurements that are key to our understanding of exoplanet demographics. Astrometric surveys are also critical pre-cursor observations for identifying targets for future direct imaging missions, such as the HabEx and LUVOIR mission concepts. However, Earth-mass planets orbiting Sun-like stars within 10 pc only cause a 0.3 uas astrometric signal, which is about two orders of magnitude smaller than the current state-of-the-art. In order to advance the technologies needed for future astrometry instruments, a testbed capable of simulating and measuring equivalent Earth-like exoplanet astrometric signals was created. The testbed has a stable light source that simulates a field of stars and can introduce a sub-uas astrometric signal onto a central artificial target star. This is done by illuminating an array of pinholes lithographically printed onto a glass substrate and translating, with picometer resolution, a target-star pinhole located on a centrally cut flexure feature. To detect this motion, a diffractive pupil is used to calibrate the limiting optical distortions of an Offner relay. Presented in this paper are the requirements, design, and implementation of the wide-field astrometry testbed’s light source.

Bendek, Eduardo↗

Effects of Cryogenic Temperatures on LEDs and Optical Fiber

Light Emitting Diodes (LEDs) may provide a simple, low powered light source for future space missions. However, the effects of cryogenic temperatures on LEDs and optical fibers are largely unknown. Tests were performed on a selection of commercially-available LEDs, with wavelengths varying from 468 nm to 950 nm, as well as "white" LEDs. Dry ice and liquid nitrogen (LN2) were used to bring the LEDs to the desired temperatures. The optical fibers were tested using a specially-machined brass cylinder that would allow the fibers to be cooled slowly and evenly in an LN2 dewer. An optical fiber coupled to a spectrometer was used to acquired spectra of a calibration light source (wavelength range 253-922 nm) at various temperatures. Examination of the LED spectra has shown several different effects, depending on the LED in question. Those with wavelengths above 590 nm tend to show a "blue shift" in their peak wavelength and an increase in intensity. Other LEDs developed secondary or tertiary peaks, or showed no peak shift at all, although all LEDs did show an increase in observed intensity. The optical fiber showed a slight non-uniform decrease in transmission as the temperature cooled to -195 C.

Pantel, Erica R.↗

Laser Image Contrast Enhancement System

An optical image enhancement system provides improved image contrast in imaging of a target in high temperature surroundings such as a furnace. The optical system includes a source of vertically polarized light such as laser and a beam splitter for receiving the light and directing the light toward the target. A retardation plate is affixed to a target-facing surface of the beam splitter and a vertical polarizer is disposed along a common optical path with the beam splitter between the retardation plate and the target. A horizontal polarizer disposed in the common optical path, receives light passing through a surface of the beam splitter opposed to the target-facing surface. An image detector is disposed at one end of the optical path. A band pass filter having a band pass filter characteristic matching the frequency of the vertically polarized light source is disposed in the path between the horizontal polarizer and the image detector. The use of circular polarization, together with cross polarizers, enables the reflected light to be passed to the detector while blocking thermal radiation.

Robert L Kurtz↗

Constraining Stellar Photospheres as an Essential Step for Transmission Spectroscopy of Small Exoplanets

Transiting exoplanets offer a unique opportunity to study the atmospheres of terrestrial worlds in other systems in the coming decade. By absorbing and scattering starlight, exoplanet atmospheres produce spectroscopic transit depth variations that allow us to probe their physical structures and chemical compositions. These same variations, however, can be introduced by the photospheric heterogeneity of the host star (i.e., the transit light source effect). Recent modeling efforts and increasingly precise observations are revealing that our understanding of transmission1spectra of the smallest transiting exoplanets will likely be limited by our knowledge of host star photospheres. Here we outline promising scientific opportunities for the next decade that can provide useful constraints on stellar photospheres and inform interpretations of transmission spectra of the smallest(R < 4R) exoplanets. We identify and discuss four primary opportunities: (1) refining stellar magnetic active region properties through exoplanet crossing events; (2) spectral decomposition of active exoplanet host stars; (3) joint retrievals of stellar photospheric and planetary atmospheric properties with studies of transmission spectra; and (4) continued visual transmission spectroscopy studies to complement longer-wavelength studies from JWST. In this context, we make four recommendations to the Astro2020 Decadal Survey Committee:(1) identify the transit light source (TLS) effect as a challenge to precise exoplanet transmission spectroscopy and an opportunity ripe for scientific advancement in the coming decade; (2) include characterization of host star photospheric heterogeneity as part of a comprehensive research strategy for studying transiting exoplanets; (3) support the construction of ground-based extremely large telescopes (ELTs); (4) support multi-disciplinary research teams that bring together the heliophysics, stellar physics, and exoplanet communities to further exploit transiting exoplanets as spatial probes of stellar photospheres; and (5) support visual transmission spectroscopy efforts as complements to longer-wavelength observational campaigns with JWST.

Rackham, Benjamin V.↗

Constraining Stellar Photospheres as an Essential Step for Transmission Spectroscopy of Small Exoplanets

Transiting exoplanets offer a unique opportunity to study the atmospheres of terrestrial worlds in other systems in the coming decade. By absorbing and scattering starlight, exoplanet atmospheres produce spectroscopic transit depth variations that allow us to probe their physical structures and chemical compositions. These same variations, however, can be introduced by the photospheric heterogeneity of the host star (i.e., the transit light source effect). Recent modeling efforts and increasingly precise observations are revealing that our understanding of transmission spectra of the smallest transiting exoplanets will likely be limited by our knowledge of host star photospheres. Here we outline promising scientific opportunities for the next decade that can provide useful constraints on stellar photospheres and inform interpretations of transmission spectra of the smallest (R < 4R ) exoplanets. We identify and discuss four primary opportunities: (1) refining stellar magnetic active region properties through exoplanet crossing events; (2) spectral decomposition of active exoplanet host stars; (3) joint retrievals of stellar photospheric and planetary atmospheric properties with studies of transmission spectra; and (4) continued visual transmission spectroscopy studies to complement longer-wavelength studies from JWST. In this context, we make four recommendations to the Astro2020 Decadal Survey Committee: (1) identify the transit light source (TLS) effect as a challenge to precise exoplanet transmission spectroscopy and an opportunity ripe for scientific advancement in the coming decade; (2) include characterization of host star photospheric heterogeneity as part of a comprehensive research strategy for studying transiting exoplanets; (3) support the construction of ground-based extremely large telescopes (ELTs); (4) support multi-disciplinary research teams that bring together the heliophysics, stellar physics, and exoplanet communities to further exploit transiting exoplanets as spatial probes of stellar photospheres; and (5) support visual transmission spectroscopy efforts as complements to longer-wavelength observational campaigns with JWST.

Benjamin V. Rackham↗

Optical crystal temperature gauge with fiber optic connections

An optical temperature gauge uses a semiconductor crystal with a band-edge shift property which is temperature dependent. An external narrow band light source provides optical excitation through a optical fiber and light energy thus passed through the crystal is conveyed by a second optical fiber to a light-to-electric transducers at an external location. The crystal can be located in cryogenic or other systems, to provide remote read-out. The light wavelength is varied (scanned) in a repetitive pattern in source with the instantaneous wavelength passing over the band-edge wavelength during each cycle of the scan. The timing of the crossover is related to the temperature of the crystal by electronic means. Several alternative elements of instrumentation are disclosed. A variation in the basic measurement apparatus is also disclosed, in which the band gap voltage of a light source such as a laser diode is evaluated at the time of band-edge crossover in the crystal and converted to a temperature value.

Sharma, M. M.↗

Photographic method measures particle size and velocity in fluid stream

Method employing a nonframing motion picture camera, a continuous front light source, and a strobe light determines the size and velocity of small particles in nonturbulent fluid streams. This method is used in the study of the motion of solid and liquid particles in research and industrial fluid flow systems.

Dickerson, R. A.↗

Carrier suppression device for a heterodyne gas analyzer

Analyzer operates with broadband light from blackbody infrared source. Light is passed sequentially through two gas-filled chambers to suitable infrared detector while pressures in gas-filled chambers are modulated in sinusoidal manner. Because pressure of infrared-absorbing gases in chambers is modulated, amount of light absorbed by gases is also modulated.

Mcclatchie, E. A.↗

Schlieren with a laser diode source

The use of a laser diode as a light source for a schlieren system designed to study phase objects such as a wind-tunnel flow is explored. A laser diode schlieren photograph and a white light schlieren photograph (zirconium arc source) are presented for comparison. The laser diode has increased sensitivity, compared with light schlieren, without appreciable image degradiation, and is an acceptable source for schlieren flow visualization.

Burner, A. W.↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

Laser with optically driven Q-switch

An optically driven interactive Q-switch, i.e., a Q-switch that responds to a short pulse of light, for example, from external light-emitting diodes (LEDs) or diode lasers, is provided for producing an output laser pulse from electronic energy stored in a laser medium. Q-switching is thus achieved on demand by electrically pulsing the light source to produce a pulse of light directed onto a Q-switch medium in the laser cavity. Electronic control of the light pulse from the external source will thus provide not only efficient Q-switching frequency but also independent control of output laser pulse width with a fast rise time for each output laser pulse.

Hemmati, Hamid↗

Laser with optically driven Q-switch

An optically driven interactive Q-switch, i.e., a Q-switch that responds to a short pulse of light, for example, from external light-emitting diodes (LED's) or diode lasers, is provided for producing an output laser pulse from electronic energy stored in a laser medium. Q-switching is thus achieved on demand by electrically pulsing the light source to produce a pulse of light directed onto a Q-switch medium in the laser cavity. Electronic control of the light pulse from the external source will thus provide not only efficient Q-switching frequency but also independent control of output laser pulse width with a fast rise time for each output laser pulse.

Hemmati, Hamid↗

The Light of the Night Sky in EUSO: Duty Cycle and Background

The EUSO detector, which will be installed on the International Space Station, will detect the light produced by the EAS generated by the UHECR when entering the Earth's atmosphere. The EUSO telescope will operate only during dark night. The light background in the EUSO detector is of outmost importance. To determine the detector duty cycle, it is necessary to know the periods in which it will be in the obscurity, taking into account both sun and moon precise ephemerides and the ISS trajectory. For signal to background determination and trigger efficiency study, the photon background has to be evaluated, taking into account the various UV light sources at night: natural sources as airglow, stars and diffuse light of the night sky, and artificial sources.

Adams, J.↗

Direction indicator system does not require complicated optics

Direction indicator which aligns a system relative to a light source uses two photocells as light sensors to form a set. Each set indicates one direction. This indicator has no moving parts and provides very fine vernier acquisition.

Mildice, J. W.↗

Pulse transducer with artifact signal attenuator

An artifact signal attenuator for a pulse rate sensor is described. The circuit for attenuating background noise signals is connected with a pulse rate transducer which has a light source and a detector for light reflected from blood vessels of a living body. The heart signal provided consists of a modulated dc signal voltage indicative of pulse rate. The artifact signal resulting from light reflected from the skin of the body comprises both a constant dc signal voltage and a modulated dc signal voltage. The amplitude of the artifact signal is greater and the frequency less than that of the heart signal. The signal attenuator circuit includes an operational amplifier for canceling the artifact signal from the output signal of the transducer and has the capability of meeting packaging requirements for wrist-watch-size packages.