Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LiF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Optics and materials considerations for a laser-propelled lightsail

The principles of a laser-propelled lightsail for an interstellar probe are discussed. The feasibility of a laser-propelled-lightsail round-trip interstellar mission proposed by Forward (1984) is examined, with special attention given to the issues of optics and materials. It is shown that the large lens and a high lens/target distance required by such a mission result in optical difficulties, requiring positioning tolerance for the 1000-km-diam lens of only 3 m, which is unlikely to be achievable. Techniques and sail materials that would reduce this problem are suggested, including the use of LiF and CaF2 quarter-wave dielectric films and the use of many intermediate lenses spaced between the probe and the source. It is pointed out that, as sail materials, the quarter-wavelength dielectric films have significant advantages over metals.

Landis, Geoffrey A.↗

The electrochemical generation of useful chemical species from lunar materials

Electrochemical cells have been fabricated for the simultaneous generation of oxygen and lithium from a Li2O-containing molten salt (Li2O-LiCl-LiF). The cell utilizes an oxygen vacancy conducting solid electrolyte, yttria-stabilized zirconia (YSZ), to effect separation between oxygen evolving and lithium reduction half-cell reactions. The cell, which operates at 700-850 C, possesses rapid electrode kinetics at the lithium-alloy electrode with exchange current density values being greater than 60 mA/sq cm. When used in the electrolytic mode, lithium produced at the negative electrode would be continuously removed from the cell for later use (under lunar conditions) as an easily storable reducing agent for the chemical refining of lunar ores. Because of the high reversibility of this electrochemical system, it has also formed the basis for the lithium-oxygen secondary battery system which possesses the highest theoretical energy density yet investigated.

Tsai, Kan J.↗

Single pulse vibrational Raman scattering by a broadband KrF excimer laser in a hydrogen-air flame

Spontaneous vibrational Raman scattering (VRS) is produced by a broadband excimer laser at 248 nm (KrF) in a H2-air flame, and VRS spectra are recorded for lean, stoichiometric, and rich flames. Except at very lean flame conditions, laser-induced fluorescence (LIF) processes interfere with VRS Stokes lines from H2, H2O, and O2. No interference is found for the N2 Stokes and N2 anti-Stokes lines. In a stoichiometric H2/air flame, single-pulse measurements of N2 concentration and temperature (by the VRS Stokes to anti-Stokes ratio) have a relative standard deviation of 7.7 and 10 percent, respectively. These single pulse measurement errors compare well with photon statistics calculations using measured Raman cross sections.

Pitz, Robert W.↗

The cavity heat pipe Stirling receiver for space solar dynamics

The receiver/storage unit for the low-earth-orbiting Stirling system is discussed. The design, referred to as the cavity heat pipe (CHP), has been optimized for minimum specific mass and volume width. A specific version of this design at the 7-kWe level has been compared to the space station Brayton solar dynamic design. The space station design utilizes a eutectic mixture of LiF and CaF2. Using the same phase change material, the CHP has been shown to have a specific mass of 40 percent and a volume of 5 percent of that of the space station Brayton at the same power level. Additionally, it complements the free-piston Stirling engine in that it also maintains a relatively flat specific mass down to at least 1 kWe. The technical requirements, tradeoff studies, critical issues, and critical technology experiments are discussed.

Kesseli, James B.↗

Velocity mapping in the plume of a 30-kW ammonia arcjet

The flow velocity of atomic hydrogen in the plume of an ammonia-propelled arcjet was measured using LIF. The velocity was obtained by the Doppler shift of the absorption peak of the Balmer alpha spectral line. Measurements were made at the nozzle exit, varying the distance from the plume centerline. Results are presented for arcjet operating conditions 13, 20 and 27 kW with a mass flow of 0.31 g/s. The on-axis H flow velocity varies from 14 km/s to 28 km/s over this range of input power. The axial velocity as a function of the distance from the axis is sharply peaked, dropping to almost zero at a radius of less than 5 mm.

Pham-Van-diep, Gerald C.↗

An intercomparison of airborne nitrogen dioxide instruments

Results on NO2 instruments are reported from the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) program in summer 1986. The instruments tested were (1) a two-photon LIF system using a laser for NO2-NO photolysis, (2) a chemiluminescence (CL) detector using FeSO4 for NO2-NO conversion, (3) a CL detector using an arc lamp for NO2-NO photolysis, and (4) a tunable-laser-diode multipath-absorption system. The procedures for the CITE 2 ground-based and flight tests are described in detail, and the results are presented in extensive graphs. Instrument (2) was eliminated because the FeSO4 converted atmospheric PAN to NO, resulting in spuriously high NO2 values. The remaining instruments gave readings in 30-40-percent agreement at NO2 mixing ratios of 100-200 parts per trillion by volume (pptv). At ratios below 50 pptv, the correlation among the measurements was very poor, with a tendency for system (4) to give higher values than (1) or (3).

Gregory, G. L.↗

An intercomparison of airborne nitric oxide measurements - A second opportunity

Results are reported from a comparison of three tropospheric NO measurement instruments during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) in summer 1986. The instruments tested were those used in CITE 1 (Hoell et al., 1987): a two-photon LIF system and two chemiluminescence systems. It is found that the mixing ratios obtained with the three systems agreed to within 15-20 parts per trillion volume (pptv) for sampling perods of 1-6 min at mixing ratios less than 20 pptv; the average difference between pairs of measurements was 5-7 pptv, which is considered to be the uncertainty in state-of-the-art ambient NO measurements.

Gregory, Gerald L.↗

Measurements of the nitric acid to NO(x) ratio in the troposphere

Nitric acid concentrations, measured by both teflon/nylon filter packs (FP) and the tungstic oxide denuder (DEN), are compared with the average NO(x) concentrations from LIF and chemiluminescent methods. The HNO3/NO(x) ratio based on FPs ranged from 0.8 to 10.4, with a mean of 3.4. The DEN nitric acid concentrations produced ratios ranging from less than 0.3 to 9.8, with a mean of 2.6. Average marine ratios were larger than those from continental regions, in part due to continental anthropogenic sources of NO(x).

Huebert, B. J.↗

VUV-visible measurements on different samples of amorphous carbon

Among various candidate materials for interstellar dust, amorphous carbon (AC) is playing an increasingly important role (Greenstein, 1981; Hecht et al., 1984; Jura, 1983, 1986). Furthermore, recent in situ measurements have clearly shown the presence of carbonaceous grains in the coma of comet Halley (Kissel et al., 1986). Laboratory investigations on AC grains may be very useful to better interpret observations and to support theoretical elaborations. Recently, the authors started an international research program which also includes UV extinction analyses on AC samples, by using synchrotron light. Preliminary results obtained in a first shift of measurements, last June, are given. At the present stage of the data analysis, the authors can only draw some preliminary considerations. A wide band falling at around 240 nm is detected in all the analyzed samples. It intensity seems to decrease with increasing the dust collecting distance. A peak at 150 nm decreases in intensity with increasing the collecting distance. The band seems absent in the samples characterized by a larger amount of dust. A feature at about 200 nm is detected in some samples. At the moment the authors tend to attribute it to the transmission properties of the LiF substrates at the wavelength and/or to some problems in the experimental setup. It is unclear if a hump at 120 nm is real or due to instrumental effects. The profile of the spectra does not show substantial changes when the samples are cooled down to about 100 K. The present results appear to be in general agreement with previous findings, but their analysis is in progress and the interpretation is still on the way.

Blanco, A.↗

Development of a two photon/laser induced fluorescence technique for the detection of atmospheric OH radicals

The development of a new mid-IR laser source was the primary goal. Backward propagating stimulated D2 Raman frequency down conversion of a commercially available 1.06 micron Nd:YAG laser was shown to generate an efficient source of 1.56 micron radiation with near diffraction limited beam quality. The efficient generation of a 2.9 micron laser source was also achieved using backward propagating CH4 Raman frequency down conversion of the 1.56 micron pump. Slightly higher efficiencies were obtained for frequency down conversion of the 1.06 micron Nd:YAG using the H2 Raman shift yielding a near diffraction limited source in the 200 mJ range at 1.9 micron. Similar conversion efficiencies are anticipated as a result of extending the wavelength coverage of recently available Ti:sapphire pulse laser to not only cover the 740 to 860 nm fundamental wavelength range but also the .95 to 1.15 and 1.06 to 1.33 micron range using D2 and H2, respectively. The anticipated sensitivity of a TP-LIF OH sensor using this mid-IR source would give signal limited detection of 1.4 x 10(exp 5) OH/cu cm under boundary layer conditions and 5.5 x 10(exp 4) OH/cu cm under free troposphere sampling conditions for a five minute signal integration period. This level of performance coupled with the techniques non-perturbing nature and freedom from both interferences and background would allow reliable tropospheric OH measurement to be obtained under virtually any ambient condition of current interest, including interstitial and sampling.

Bradshaw, John↗

Multi-dimensional modeling of a thermal energy storage canister

The Solar Dynamic Power Module being developed for Space Station Freedom uses a eutectic mixture of LiF-CaF2 phase change material (PCM) contained in toroidal canisters for thermal energy storage. Presented are the results from heat transfer analyses of a PCM containment canister. One and two dimensional finite difference computer models are developed to analyze heat transfer in the canister walls, PCM, void, and heat engine working fluid coolant. The modes of heat transfer considered include conduction in canister walls and solid PCM, conduction and pseudo-free convection in liquid PCM, conduction and radiation across PCM vapor filled void regions, and forced convection in the heat engine working fluid. Void shape, location, growth or shrinkage (due to density difference between the solid and liquid PCM phases) are prescribed based on engineering judgment. The PCM phase change process is analyzed using the enthalpy method. The discussion of the results focuses on how canister thermal performance is affected by free convection in the liquid PCM and void heat transfer. Characterizing these effects is important for interpreting the relationship between ground-based canister performance (in 1-g) and expected on-orbit performance (in micro-g). Void regions accentuate canister hot spots and temperature gradients due to their large thermal resistance. Free convection reduces the extent of PCM superheating and lowers canister temperatures during a portion of the PCM thermal charge period. Surprisingly small differences in canister thermal performance result from operation on the ground and operation on-orbit. This lack of a strong gravity dependency is attributed to the large contribution of container walls in overall canister energy redistribution by conduction.

Kerslake, Thomas W.↗

Thermoluminescent dosimeter measurements and analysis for LDEF experiment M0006

Glow curve measurements are reported up to 600 C of (Thermoluminescent Dosimeter Measurement) TLD-100 (LiF) samples deployed on Long Duration Exposure Facility (LDEF) and retained as ground control. Lab exposure simulations are also reported with Co-60 radiation, low energy light ions and high energy protons in an effort to replicate the glow curves, especially the high temperature peaks observed in the LDEF TLD specimens. The evidence to date clearly shows the effect of inflight anneal on the low temperature part of the glow curve. It also shows that the high temperature part of the glow curve appears due to ion dose deposition. Initial correlations between high temperature glow peaks and effective LET of the registered dose is given.

Stauber, Michael C.↗

Radiation exposure of LDEF: Initial results

Initial results from Long Duration Exposure Facility (LDEF) include radiation detector measurements from four experiments; P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also at the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose dependence of a factor of approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly (SAA). On the trailing edge of the orbiter, a range of doses from 664 to 291 rad were measured under nominal shielding of 0.42 to 8.45 g/sq cm. A second set of detectors near this locations results are also given. On the leading edge, doses of 258 to 210 rad were found under shielding of 1.25 to 2.48 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses, and dose equivalents, for LET in H2O greater than or = 5 keV/micron, were measured with plastic nuclear track detectors located in the four experiments. Also, preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

Benton, E. V.↗

Optical diagnostic investigation of low Reynolds number nozzle flows

The objectives are to obtain temperature, density and velocity profile measurements in the expansion region of low Reynolds number nozzles through the use of optical diagnostics. An LIF system will be used to probe the expansion of a microwave-heated expansion in the Center vacuum facility. The experimental measurements made in this program will be compared to numerical predictions obtained by Drs. Charles Merkle and Lyle Long.

Micci, Michael M.↗

Simultaneous, in situ measurements of OH and HO2 in the stratosphere

Stratospheric OH and HO2 radical densities have been measured between 36 and 23 km using a balloon-borne, in situ instrument launched from Palestine, Texas on August 25, 1989. OH is detected using the laser-induced fluorescence technique (LIF) employing a Cu-vapor-laser pumped dye laser coupled with an enclosed-flow detection chamber. HO2 is detected nearly simultaneously by adding NO to the sample flow to convert ambient HO2 to OH. Observed OH and HO2 densities ranged from 8.0 + or - 2.8 x 10 to the 6th and 1.4 + or - 0.5 x 10 to the 7th molec/cu cm, respectively, at 36 km, to 1.4 + or - 0.5 x 10 to the 6th and 3.0 + or - 1.0 x 10 to the 6th at 23 km, where the uncertainty is + or - sigma. The HO2 density exhibits a maximum in the 34-30 km region of 1.7 + or - 0.6 x 10 to the 7th. The data were obtained over a solar zenith angle variation of 51 deg at 36 km to 61 deg at 23 km. O3 and H2O densitites also were measured simultaneously with separate instruments.

Stimpfle, R. M.↗

Laser diagnostics on a hypersonic combustor

NASA-Langley has implemented a laser-based multipoint/multiparameter diagnostics system at its hypersonic direct-connect combustor, in order to measure both temperature and majority species densities in two dimensions, using spatially-scanned CARS; in addition, line-imaged measurements of radical densities are simultaneously generated by LIF at any of several planes downstream of the fuel injector. Initial experimental trials have demonstrated successful detection of one-dimensional images of OH density, as well as CARS N2-temperature measurements, in the turbulent reaction zone of the hypersonic combustor.

Taylor, David J.↗

Two-dimensional model of a Space Station Freedom thermal energy storage canister

The Solar Dynamic Power Module being developed for Space Station Freedom uses a eutectic mixture of LiF-CaF2 phase change salt contained in toroidal canisters for thermal energy storage. Results are presented from heat transfer analyses of the phase-change salt containment canister. A 2-D, axisymmetric finite-difference computer program which models the canister walls, salt, void, and heat engine working fluid coolant was developed. Analyses included effects of conduction in canister walls and solid salt, conduction and free convection in liquid salt, conduction and radiation across salt vapor filled void regions, and forced convection in the heat engine working fluid. Void shape, location, and growth or shrinkage (due to density difference between the solid and liquid salt phases) were prescribed based on engineering judgement. The salt phase change process was modeled using the enthalpy method. Discussion of results focuses on the role of free-convection in the liquid salt on canister heat transfer performance. This role is shown to be important for interpreting the relationship between groundbased canister performance (in 1-g) and expected on-orbit performance (in micro-g). Attention is also focused on the influence of void heat transfer on canister wall temperature distributions. The large thermal resistance of void regions is shown to accentuate canister hot spots and temperature gradients.

Kerslake, Thomas W.↗

Analysis of radiative and phase-change phenomena with application to space-based thermal energy storage

The simplified geometry for the analysis is an infinite, axis symmetric annulus with a specified solar flux at the outer radius. The inner radius is either adiabatic (modeling Flight Experiment conditions), or convective (modeling Solar Dynamic conditions). Liquid LiF either contacts the outer wall (modeling ground based testing), or faces a void gap at the outer wall (modeling possible space based conditions). The analysis is presented in three parts: Part 3 considers and adiabatic inner wall and linearized radiation equations; part 2 adds effects of convection at the inner wall; and part 1 includes the effect of the void gap, as well as previous effects, and develops the radiation model further. The main results are the differences in melting behavior which can occur between ground based 1 g experiments and the microgravity flight experiments. Under 1 gravity, melted PCM will always contact the outer wall having the heat flux source, thus providing conductance from this source to the phase change front. In space based tests where a void gap may likely form during solidification, the situation is reversed; radiation is now the only mode of heat transfer and the majority of melting takes place from the inner wall.

Lund, Kurt O.↗