Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lasers, Optics and optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Optical measurement systems

Some of the areas of research conducted at Lewis on optical measurement techniques are described. Two laser anemometer systems developed at Lewis are used to illustrate the special instrumentation needs encountered in aeropropulsion research. Velocity measurements to be made through small viewing ports, close to surfaces within the propulsion system components, and in turbulent or highly-accelerating flows are some of the significant challenges. The application to research facilities of two advanced optical systems, the rainbow schlieren and the combustor viewing system, is presented. The calibration and verification of commercial optical measuring systems, such as droplet sizing systems, are also discussed. Calibration techniques capable of simulating moving droplets for flight-type sizing systems are being developed at Lewis. The presentation concludes with a brief look at the forces driving future research on optical instrumentation.

Lesco, Daniel J.↗

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

Qualification of a Multi-Channel Infrared Laser Absorption Spectrometer for Monitoring CO, HCl, HCN, HF, and CO2 Aboard Manned Spacecraft

Monitoring of specific combustion products can provide early-warning detection of accidental fires aboard manned spacecraft and also identify the source and severity of combustion events. Furthermore, quantitative in situ measurements are important for gauging levels of exposure to hazardous gases, particularly on long-duration missions where analysis of returned samples becomes impractical. Absorption spectroscopy using tunable laser sources in the 2 to 5 micrometer wavelength range enables accurate, unambiguous detection of CO, HCl, HCN, HF, and CO2, which are produced in varying amounts through the heating of electrical components and packaging materials commonly used aboard spacecraft. Here, we report on calibration and testing of a five-channel laser absorption spectrometer designed to accurately monitor ambient gas-phase concentrations of these five compounds, with low-level detection limits based on the Spacecraft Maximum Allowable Concentrations. The instrument employs a two-pass absorption cell with a total optical pathlength of 50 cm and a dedicated infrared semiconductor laser source for each target gas. We present results from testing the five-channel sensor in the presence of trace concentrations of the target compounds that were introduced using both gas sources and oxidative pyrolysis (non-flaming combustion) of solid material mixtures.

environmental monitoring↗

Stable Isotope Laser Spectrometer for Exploration of Mars

On Earth, measurements of the ratios of stable carbon isotopes have providet much information about geological and biological processes. For example, fractionation of carbon occur in biotic processes and the retention of a distinctive 2-4% contrast in C-13/C-12 between organic carbon and carbonates in rocks as old as 3.8 billion years constitutes some of the firmest evidence for the antiquity of life on the Earth. We have developed a prototype tunable diode laser spectrometer which demonstrates the feasibility of making accurate in situ isotopic ratio measurements on Mars. This miniaturized instrument, with an optical path length of 10 cm should be capable of making accurate C-13/C-12 and N-15/N-14 measurements. Gas samples for measurement are to be produced by pyrolysis using soil samples as small as 50 mg. Measurements of C-13/C-12, O-18/O-16 and N-15/N-14 have been made to a precision of better than 0.1%, and various other isotopes are feasible. This laser technique, which relies on the extremely narrow emission linewidth of tunable diode lasers (less than 0.001/ cm),has favorable features in comparison to mass spectrometry, the standard method of accurate isotopic ratio measurement. The miniature instrument could be ready to deploy c 2003 or other Mars lander missions.

Sauke, Todd B.↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aerodyne Research mobile infrared methane monitor

An improved real-time methane monitor based on infrared absorption of the 3.39 micron line of a HeNe laser is described. Real time in situ measurement of methane has important applications in stratospheric and tropospheric chemistry, especially when high accuracy measurements can be made rapidly, providing fine spatial-scale information. The methane instrument provides 5 ppb resolution in a 1 sec averaging time. A key feature in this instrument is the use of magnetic (Zeeman) broadening to achieve continuous tunability with constant output power over a range of 0.017/cm. The instruments optical absorption path length is 47 m through sampled air held at 50 torr in a multipass cell of the Herriott (off-axis resonator) type. A microprocessor controls laser frequency and amplitude and collects data with minimal operator attention. The instrument recently has been used to measure methane emissions from a variety of natural and artificial terrestrial sources.

Mcmanus, J. B.↗

Limited flight test experience with a laser transit velocimeter

Limited flight testing of a laser transit velocimeter provided insight into the problems associated with the use of such instruments for flight research. Although the device tested was not designed for flight application, it had certain features such as fiber optics and low laser power which are attractive in the airborne environment. During these tests, operation of the velocimeter was limited by insufficient concentrations of light-scattering particles and background light interference. Normal operation was observed when these conditions were corrected by utilizing cloud particles and flying at night. A comparison between the laser flow velocity measurements and corresponding pressure measurements is presented and shows a coarse correlation. Statistical bias due to turbulence in the flow is suspected to have affected the laser measurements.

Curry, R. E.↗

Laboratory Studies of the Photochemistry of Peroxynitric Acid

Observations of odd hydrogen radicals at high SZA in the lower stratosphere have demonstrated that our understanding of the HO(x) chemistry is incomplete [Wennberg et al., 1994a; Salawitch et al., 1994; Wennberg et al., 1999]. In particular, the concentrations of the HO(x) radicals are significantly larger than expected under weak photolytic conditions. Donaldson et al. [1997] have speculated that excitation of overtones of the OH stretching frequency in molecules such as HNO3 and HO2NO2 may be significant sources of HO(x) under these conditions. Although weak, vibrationally mediated photolysis may be important because it occurs in the near IR and visible and can provide energy in excess of the dissociation energy (D(o)): HONO2 + hv yields OH + NO (D(o) approx. 600 nm) and HOONO2 + hv yields OH + NO3 (D(o) approx. 735 nm) HOONO2 + hv yields HO2 + NO2 (D(o) approx. 1250 nm). In this project we developed instrumentation to characterize the photodissociation yields of hydroxyl containing compounds in the visible and near IR. This effort has involved coupling a tunable photolysis optical parametric oscillator (OPO) laser system with precise determination of the hydroxyl radical. The OPO system [Wu et al., 1997] was developed with support from the NSF Major Research Instrumentation Fund in a proposal entitled "Development of Novel, Compact Light Sources for Advanced Spectroscopy in Atmospheric Science and Materials Research" (Geoffrey A. Blake, P.I. California Institute of Technology).

Wennberg, Paul O.↗

Measurement of vortex flow fields

A 3-D laser fluorescence anemometer (LFA) was designed, built, and demonstrated for use in the Langley 16 x 24 inch Water Tunnel. Innovative optical design flexibility combined with compact and portable data acquisition and control systems were incorporated into the instrument. This will allow its use by NASA in other test facilities. A versatile fiber optic system facilities normal and off-axis laser beam alignment, removes mirror losses and improves laser safety. This added optical flexibility will also enable simple adaptation for use in the adjacent jet facility. New proprietary concepts in transmitting color separation, light collection, and novel prism separation of the scattered light was also designed and built into the system. Off-axis beam traverse and alignment complexity led to the requirement for a specialized, programmable transverse controller, and the inclusion of an additional traverse for the off-axis arm. To meet this challenge, an 'in-house' prototype unit was designed and built and traverse control software developed specifically for the water tunnel traverse applications. A specialized data acquisition interface was also required. This was designed and built for the LFA system.

Mcdevitt, T. Kevin↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rangefinder Corrects for Air Density and Moisture

Proposed distance-measuring instrument compensates for variations in both dry atmospheric density and water-vapor content. Instrument would be expected to be more accurate than previous laser-ranging instruments. New rangefinder sends three signal trains to target: Two trains are at optical frequencies, and one is at a microwave frequency. All three signals are phase-locked.

Abshire, J. B.↗

Airborne Laser Polarization Sensor

Instrument measures polarization characteristics of Earth at three wavelengths. Airborne Laser Polarization Sensor (ALPS) measures optical polarization characteristics of land surface. Designed to be flown at altitudes of approximately 300 m to minimize any polarizing or depolarizing effects of intervening atmosphere and to look along nadir to minimize any effects depending on look angle. Data from measurements used in conjunction with data from ground surveys and aircraft-mounted video recorders to refine mathematical models used in interpretation of higher-altitude polarimetric measurements of reflected sunlight.

Kalshoven, James, Jr.↗

Compact spaceflight solution crystal-growth system

A versatile, miniaturized, stand alone, crystal solution growth chamber design is presented which is based on fiber optics, diode lasers, and holographic optical elements in conjunction with knowledge gained from previous Spacelab work. Diagnostics instrumentation is based on a crystal growth monitor, a growth/dissolution monitor with feedback, solution diagnostics, multiple wavelength holography, and single wavelength or color Schlieren with video recording.

Trolinger, James D.↗