Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOW LEVEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Hydraulic Conductivity of Geosynthetic Clay Liners to Low-Level Radioactive Waste Leachate

Hydraulic conductivity was evaluated for eight commercially available geosynthetic clay liners (GCLs) permeated with leachate characteristic of low-level radioactive waste (LLW) disposal facilities operated by the U.S. Department of Energy (DOE). Two of the GCLs (CS and GS) contained conventional sodium bentonite (Na-B). The others contained a bentonite–polymer mixture (CPL, CPH, GPL1, GPL2, and GPH) or bentonite–polymer composite (BPC). All GCLs (except GPL2 and GPH) were permeated directly with two synthetic LLW leachates that are essentially identical, except one has no radionuclides (nonradioactive synthetic leachate, or NSL) and the other has radionuclides (radioactive synthetic leachate, or RSL). Hydraulic conductivities to RSL and NSL were identical. For the CS and GS GCLs, the hydraulic conductivity gradually increased by a factor of 5–25 because divalent cations in the leachate replaced native sodium cations bound to the bentonite. The CPL, GPL1, and GPL2 GCLs with low polymer loading (1.2–3.3%) had hydraulic conductivities similar to the conventional GCLs. In contrast, hydraulic conductivity of the CPH, GPH, and BPC GCLs with high polymer loading (≥5%) to RSL or NSL was comparable to, or lower than, the hydraulic conductivity to deionized water. Permeation with leachate reduced the swell index of the bentonite in all of the GCLs. A conceptual model featuring pore blocking by polymer hydrogel is proposed to explain why the hydraulic conductivity of bentonite–polymer GCLs to LLW leachates remains low even though the leachate inhibits bentonite swelling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examination of Regional Trends in Low Level Cloud Properties Found in the Aqua-MODIS Satellite Record

Clouds have a pronounced influence on the Earth?s climate. Relative to cloud free conditions, they cool the planet by increasing the amount of solar radiation reflected back to space and reducing the amount of sunlight reaching the surface, but they warm the planet by decreasing the amount of thermal infrared radiation escaping to space and increasing the amount reaching the surface (a greenhouse effect). The global mean net cloud radiative effect (CRE) is about -20 W/m2, a cooling effect at both the top-ofatmosphere and surface. Given the magnitude of CRE?s, it is expected that changes in cloud properties could be a significant factor in climate change due to anthropogenic forcing?s, yet cloud feedbacks are not well known and remain one of the largest uncertainties in climate prediction. This paper explores relationships between coincident observations of atmospheric aerosols, clouds and radiation derived from the Moderate Resolution Imaging Spectroradiometer (MODIS) and from the Clouds and the Earth?s Radiant Energy System (CERES) instruments on the Aqua satellite. We investigate several interesting regional trends that have emerged in the nearly 18-year satellite record that suggest correlation between changes in low-level cloud properties and changes in aerosol optical depth that may be associated with changes in pollution emissions and possibly with other factors. MERRA reanalysis of meteorological conditions and aerosol particulate species are investigated to help better understand the potential mechanisms responsible for the observed cloud property trends. Finally, we analyze a new CERES flux by cloud type dataset in order to try and isolate the associated trends in low-level cloud radiative effects. It is anticipated that this study using long-term observations of clouds, aerosols and radiative fluxes combined with model reanalysis data will contribute to an improved understanding of cloud climate feedbacks.

William L Smith Jr.↗

ObstacleSense: Low-Power Neuromorphic Vision for Corridor Obstacle Awareness in Low-Level ADAS

The automotive industry’s pursuit of Level 5 autonomy is constrained by substantial perception-compute power requirements, often reaching 1, 000 + watts in full autonomy stacks. Reducing this energy burden requires rethinking perception not only at the high-end autonomy level, but also at the foundational Advanced Driver Assistance Systems (ADAS) level where low-power, safety-critical sensing can have broad impact. Neuromorphic vision provides a promising starting point: HD Dynamic Vision Sensors (DVS) can operate below 100 mW at the sensor level by reporting only asynchronous brightness changes. However, low-power sensing alone is insufficient if downstream perception reintroduces dense, energy-intensive computation. In particular, many event-driven object-detection pipelines still rely on CNN backbones, while purely spiking alternatives often trade away accuracy or ignore deployment constraints. We introduce ObstacleSense, a highly compact, CNN-free hybrid ANN–SNN framework for Level 0–1 forward-corridor obstacle awareness. Instead of performing full-scene object detection with a convolutional feature backbone, ObstacleSense targets the safety-critical question of whether the ego corridor is occupied and how far the nearest obstacle is. The architecture combines polarity-conditioned event encoding, lightweight temporal spiking dynamics, axial spatial mixing, and coarse-to-fine range estimation within a regular fixed-grid compute pattern. This design avoids the dense CNN backbone commonly used in event-based detection while maintaining a small state footprint suitable for eventual small-FPGA deployment. Before hardware mapping, we evaluate the software implementation using a model-side power proxy derived from MACs, weight and activation traffic, and spiking state updates under shared FP16 assumptions. On simulated CARLA event corpora, the deployment-oriented model achieves 0.9464 objectness F1, 0.9978 grid-level mAP, and 0.8987 m distance Mean Absolute Error at an estimated 1.92 mW proxy cost, while maintaining performance on unseen generalization test sequences.

Johnson-Scott, Zac [ORNL]↗

Developments in Very Low Level Waste/Exempt Waste Assay at AWE - 12000

Portable High Resolution Gamma Spectrometry (HRGS) has been developed, for Very Low Level Waste (VLLW) and Exempt Waste (EW) assay at AWE, in order to meet the latest reduced clearance levels of < 1 Bq/g (or Bq/cm{sup 2}) for uranium (U) contaminated wastes and < 0.15 Bq/g (or Bq/cm{sup 2}) for plutonium (Pu) wastes. Studies have focused on a 10 kg bag of low density soft waste monitored either as a rotating cylinder, contained within a shortened plastic drum liner, or as a contained disk monitored on each broad side. Liquid and surface contaminated metal wastes have also been studied. It was established that monitoring the disk gave the best detection levels, but uncertainties rose more sharply, compared to the cylinder, as detector offset was reduced. Exempt detection levels were readily achieved for all U compositions encountered at AWE and for most Pu compositions (via Am-241 measurement). However, performance will need to be enhanced for those Pu compositions with relatively high Pu/Am-241 activity ratios. Recommendations are made for further developments to enhance the performance of this technique so that exempt clearance can be achieved for all Pu compositions encountered. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identification of Low-level Point Radioactive Sources using a sensor network

Identification of a low-level point radioactive source amidst background radiation is achieved by a network of radiation sensors using a two-step approach. Based on measurements from three or more sensors, a geometric difference triangulation method or an N-sensor localization method is used to estimate the location and strength of the source. Then a sequential probability ratio test based on current measurements and estimated parameters is employed to finally decide: (1) the presence of a source with the estimated parameters, or (2) the absence of the source, or (3) the insufficiency of measurements to make a decision. This method achieves specified levels of false alarm and missed detection probabilities, while ensuring a close-to-minimal number of measurements for reaching a decision. This method minimizes the ghost-source problem of current estimation methods, and achieves a lower false alarm rate compared with current detection methods. This method is tested and demonstrated using: (1) simulations, and (2) a test-bed that utilizes the scaling properties of point radioactive sources to emulate high intensity ones that cannot be easily and safely handled in laboratory experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assimilation of Satellite-Derived Soil Moisture for Improved Forecasts of the Great Plains Low-Level Jet

In the context of forecasting societally impactful Great Plains low-level jets (GPLLJs), the potential added value of satellite soil moisture (SM) data assimilation (DA) is high. GPLLJs are both sensitive to regional soil moisture gradients and frequent drivers of severe weather, including mesoscale convective systems. An untested hypothesis is that SM DA is more effective in forecasts of weakly synoptically forced, or uncoupled GPLLJs, than in forecasts of cyclone-induced coupled GPLLJs. Using the NASA Unified Weather Research and Forecasting (NU-WRF) Model, 75 GPLLJs are simulated at 9-km resolution both with and without NASA Soil Moisture Active Passive SM DA. Differences in modeled SM, surface sensible (SH) and latent heat (LH) fluxes, 2-m temperature (T2), 2-m humidity (Q2), PBL height (PBLH), and 850-hPa wind speed (W850) are quantified for individual jets and jet-type event subsets over the south-central Great Plains, as well as separately for each GPLLJ sector (entrance, core, and exit). At the GPLLJ core, DA-related changes of up to 5.4 kg m–2 in SM can result in T2, Q2, LH, SH, PBLH, and W850 differences of 0.68°C, 0.71 g kg –2 , 59.9 W m –2 , 52.4 W m –2 , 240 m, and 4 m s –1 , respectively. W850 differences focus along the jet axis and tend to increase from south to north. Further, jet-type differences are most evident at the GPLLJ exit where DA increases and decreases W850 in uncoupled and coupled GPLLJs, respectively. Data assimilation marginally reduces negative wind speed bias for all jets, but the correction is greater for uncoupled GPLLJs, as hypothesized.

54 ENVIRONMENTAL SCIENCES↗

Method Development for Low Level Potassium Measurement Using the ICP-AES

Customer requirements for analyzing low levels of potassium in plutonium oxide samples prompted method development to lower the existing detection limit for K by a factor of 50. We have two ICP‐AES instruments (JY Ultima 2 and Thermo‐IRIS), but the JY ICP‐AES allows greater control in the adjustments of analytical parameters for individual elements.

Analytical Chemistry↗

The role of upper tropospheric jet streaks and lee-side cyclogenesis in the development of low level jets in the great plains

A review of 15 cases of low level jets (LLJ) which developed in the Great Plains is presented. For 12 out of the 15 cases, a systematic upper level flow pattern was isolated which includes the existence of a trough over the southwest United States and the propagation of upper level jet streaks from the Rocky Mountains toward the Great Plains. This flow pattern is responsible for lee side cyclogenesis or lee side troughing that produces the pressure gradients needed for the development of the LLJ. For the other three cases, a blocking ridge existed over the Great Plains and the upper level flow is relatively weak. It is during these situations that the classic, diurnal oscillating LLJ was observed. A more detailed review of four cases indicates that the subsynoptic scale adjustments associated with the upper level jet streak's forcing of lee side cyclogenesis could be an important factor in the development of LLJ's in the Great Plains.

Uccellini, L. W.↗

Airborne operation of an infrared low-level wind shear prediction system

Airborne testing under simulated and actual low-level wind shear conditions is underway on a NASA-Ames Learjet. An infrared CO2 band radiometer with a forward 'look distance' of 5 to 8 kilometers measures the air temperature weighted to this range ahead of the approach configured aircraft. Shear alerts occur when the difference between the forward temperature and static air temperature at the aircraft exceed a set value or when a perturbation occurs in the normally constant potential temperature. Aircraft approaches into thunderstorm downburst phenomena were simulated by approaches into cool estuarine air adjacent to much warmer air over land and by actual light wind shear conditions at Travis Air Force Base. Conditions were verified by the radiometer system with extensive on-board data acquisition.

Kuhn, P. M.↗

Siting Study for the Remote-Handled Low-Level Waste Disposal Project

The U.S. Department of Energy has identified a mission need for continued disposal capacity for remote-handled low-level waste (LLW) generated at the Idaho National Laboratory (INL). An alternatives analysis that was conducted to evaluate strategies to achieve this mission need identified two broad options for disposal of INL generated remote-handled LLW: (1) offsite disposal and (2) onsite disposal. The purpose of this study is to identify candidate sites or locations within INL boundaries for the alternative of an onsite remote handled LLW disposal facility and recommend the highest-ranked locations for consideration in the National Environmental Policy Act process. The study implements an evaluation based on consideration of five key elements: (1) regulations, (2) key assumptions, (3) conceptual design, (4) facility performance, and (5) previous INL siting study criteria, and uses a five-step process to identify, screen, evaluate, score, and rank 34 separate sites located across INL. The result of the evaluation is identification of two recommended alternative locations for siting an onsite remote-handled LLW disposal facility. The two alternative locations that best meet the evaluation criteria are (1) near the Advanced Test Reactor Complex and (2) west of the Idaho Comprehensive Environmental Response, Compensation, and Liability Act Disposal Facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Air Pathway Modeling of the E-Area Low-Level Waste Facility at the Savannah River Site - 12253

This investigation was initiated to address a concern expressed by the Department of Energy's Low Level Waste Disposal Facility Federal Review Group (LFRG) Review Team during their review of the 2008 E-Area Performance Assessment (PA). The concern was the potential for overlapping of atmospheric plumes, emanating from the soil surface above SRS LLW disposal facilities within the E-Area, to contribute to the dose received by a member of the public during the Institutional Control (IC) period. The implication of this concern was that the dose to the maximally-exposed individual (MEI) located at the SRS boundary might be underestimated during this time interval. To address this concern a re-analysis of the atmospheric pathway releases from E-Area was required. A new atmospheric release model (ARM) capable of addressing the LFRG plume overlap concern was developed. The conceptual approach to assessing the atmospheric dose to a member of the public from E-Area LLW disposal facilities is to perform sub-surface simulations of the release of volatile radionuclides from the waste zones through the overlying engineered barriers to determine a flux rate at the land surface. Then, atmospheric dispersion of the radionuclide flux is simulated in an atmospheric transport model to compute air concentrations in the vicinity of the hypothetically exposed individual. A re-analysis of atmospheric dispersion portion of the atmospheric pathway releases was not undertaken, however the Dose Release Factors (DRF's) previously computed in a atmospheric transport study were retained to convert the new surface emanation fluxes (computed with the ARM) into doses received by the MEI at the appropriate points of compliance (POC). In this way, the dose received by the MEI could be compared to the maximum permissible dose level, defined in DOE Order 435.1 as being 100 uSv/yr (10 mrem/yr). The main conclusion of this study is that for atmospheric releases from the E-Area disposal facilities, plume overlap does not cause the total dose to the MEI at the SRS boundary during IC to exceed the PA performance objective. This conclusion directly addresses the LFRG PA review team issue. Furthermore, even though the LFRG comment did not express concern for such overlap to occur during the post-Closure period, applying the 100% plume overlap strategy to atmospheric releases during this period also demonstrates that the PA performance objective for the MEI will also not be exceeded during that time-frame either. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Baseline Monitoring Data for the Remote-Handled Low-Level Waste Disposal Facility at Idaho National Laboratory

The purpose of this document is to summarize environmental monitoring data collected at the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility during the first four years of facility operations (FY 2019 through FY 2022). This summary provides a “baseline” condition for the facility, which can be used to distinguish contaminant releases from the RHLLW Disposal Facility from pre existing contamination as well as potential future releases from other sources (i.e., upgradient aquifer sources), as specified in the facility monitoring plan. Sufficient data has been collected over the first four years of operation of the RHLLW Disposal Facility to establish baseline conditions for future compliance monitoring of aquifer wells and performance monitoring of vadose zone lysimeters. Except for seven elevated tritium measurements from lysimeter HFEF-South believed to have been impacted by waste disposals, all data was deemed appropriate for establishing baseline concentrations. Monitoring of the aquifer detected indicator analytes gross alpha and gross beta and target analytes tritium and C-14. There were a few C-14 detections prior to an increase in the required detection level (RDL) after the first round of sampling. I-129 and Tc-99 were not detected above RDLs in aquifer samples. Lysimeter samples detected indicator analytes gross alpha and gross beta and target analyte tritium. Target analytes C-14, I-129, and Tc-99 were not detected above RDLs in lysimeter samples. Except for tritium, baseline concentrations of indicator and target analytes measured during the first four years of RHLLW facility operations are expected to represent conditions through the expected 20 year operating period of the facility. Elevated tritium in the aquifer, a result of past discharges of tritium at upgradient facilities, showed a decline over the first four years of operations, and levels are expected to continue to decline with time as a result of dilution and decay. Current tritium levels in lysimeter samples may be elevated due to tritium in the water applied during construction and infiltration testing of the facility. As a result, tritium concentrations in lysimeters may decline with time as a result of dilution and decay. Statistical measures (i.e., mean, standard deviation, and 99% upper confidence level [UCL]) were calculated for all detected analytes using the four years of concentration data. These measures will be used to evaluate future monitoring results and to demonstrate the facility is performing, or not performing, as established in the facility performance assessment (PA). Future monitoring results will also be combined with the baseline data in this report to further establish temporal trends and natural variability in the measurements. Based on the data collected during the baseline period, it is recommended the gross alpha action level for performance monitoring increase from 10 to 20 pCi/L due to several baseline measurements exceeding the preliminary action level of 10. An action level of 20 pCi/L is slightly greater than the 99% UCL, is protective of the aquifer, and would reduce unnecessary sampling. It is also recommended that tritium be added to the lysimeter analyte list for post-baseline period monitoring. Tritium, while not a dose concern, is a good tracer that can provide valuable information on water flow in and around the RHLLW Disposal Facility. Recommendations for a tritium action level are provided if considered necessary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing and Performance Validation of a Shielded Waste Segregation and Clearance Monitor Designed for the Measurement of Low Level Waste-13043

This paper describes the development, testing and validation of a shielded waste segregation and clearance monitor designed for the measurement of low-density low-level waste (LLW). The monitor is made of a measurement chamber surrounded by detectors and a shielded outer frame. The shielded chamber consists of a steel frame, which contains typically 1.5 inches (3.81 cm) of lead and 0.5 inches (1.27 cm) of steel shielding. Inside the shielding are plastic scintillator panels, which serve as gross gamma ray detectors. The detector panels, with embedded photomultipliers, completely surround the internal measurement chamber on all 6 sides. Care has been taken to distribute the plastic scintillator detectors in order to optimise both the efficiency for gamma ray detection and at the same time achieve a volumetric sensitivity, which is as uniform as possible. A common high voltage power supply provides the bias voltage for each of the six photomultipliers. The voltage signals arising from the detectors and photomultipliers are amplified by six sensitive amplifiers. Each amplifier incorporates a single channel analyser with both upper and lower thresholds and the digitised counts from each detector are recorded on six scalars. Operation of the device is by means of a microprocessor from which the scalars are controlled. An internal load cell linked to the microprocessor determines the weight of the waste object, and this information is used to calculate the specific activity of the waste. The monitor makes background measurements when the shielded door is closed and a sample, usually a bag of low-density waste, is not present in the measurement chamber. Measurements of the minimum detectable activity (MDA) of an earlier large volume prototype instrument are reported as part of the development of the Waste Segregation and Clearance Monitor (WSCM) described in the paper. For the optimised WSCM a detection efficiency of greater than 32% was measured using a small Cs-137 source placed in the centre of the measurement chamber. Small sources have also been used to determine the spatial variation of the detection efficiency for various positions within the measurement chamber. The data have been used to establish sentencing limits and different 'fingerprints' for specific waste streams including waste streams containing fission products and others based on other radionuclides including Am-241. Some of the test data that are presented have been used to validate the instrument performance. The monitor is currently in routine use at a nuclear facility for the measurement and sentencing of low-density low activity radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aerosol First Indirect Effects on Non-Precipitating Low-Level Liquid Cloud Properties as Simulated by CAM5 at ARM Sites

We quantitatively examine the aerosol first indirect effects (FIE) for non-precipitating low-level single-layer liquid phase clouds simulated by the Community Atmospheric Model version 5 (CAM5) running in the weather forecast mode at three DOE Atmospheric Radiation Measurement (ARM) sites. The FIE is quantified in terms of a relative change in cloud droplet effective radius for a relative change in aerosol accumulation mode number concentration under conditions of fixed liquid water content (LWC). CAM5 simulates aerosol-cloud interactions reasonably well for this specific cloud type, and the simulated FIE is consistent with the long-term observations at the examined locations. The FIE in CAM5 generally decreases with LWC at coastal ARM sites, and is larger by using cloud condensation nuclei rather than aerosol accumulation mode number concentration as the choice of aerosol amount. However, it has no significant variations with location and has no systematic strong seasonal variations at examined ARM sites.

58 GEOSCIENCES↗

Hazard Classification of the Remote Handled Low-Level Waste Disposal Facility

The Battelle Energy Alliance (BEA) at the Idaho National Laboratory (INL) is constructing a new facility to replace remote-handled low-level radioactive waste disposal capability for INL and Naval Reactors Facility operations. Current disposal capability at the Radioactive Waste Management Complex (RWMC) will continue until the facility is full or closed for remediation (estimated at approximately fiscal year 2015). Development of a new onsite disposal facility is the highest ranked alternative and will provide RH-LLW disposal capability and will ensure continuity of operations that generate RH-LLW for the foreseeable future. As a part of establishing a safety basis for facility operations, the facility will be categorized according to DOE-STD-1027-92. This classification is important in determining the scope of analyses performed in the safety basis and will also dictate operational requirements of the completed facility. This paper discusses the issues affecting hazard classification in this nuclear facility and impacts of the final hazard categorization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗