Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Lab on a Chip Application Development for Exploration

At Marshall Space Flight Center a new capability has been established to aid the advancement of microfluidics for space flight monitoring systems. Lab-On-a-Chip Application Development (LOCAD) team has created a program for advancing Technology Readiness Levels (TRL) of 1 & 2 to TRL 6 and 7, quickly and economically for Lab-On-a-Chip (LOC) applications. Scientists and engineers can utilize LOCAD's process to efficiently learn about microfluidics and determine if microfluidics is applicable to their needs. Once the applicability has been determined, LOCAD can then perform tests to develop the new fluidic protocols which are different from macro-scale chemical reaction protocols. With this information new micro-devices can be created such as the development of a microfluidic system to aid in the search for life, past and present, on Mars. Particular indicators in the Martian soil can contain the direct evidence of life. But to extract the information from the soil and present it to the proper detectors requires multiple fluidic/chemical operations. This is where LOCAD is providing its unique abilities.

Monaco, Lisa↗

Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments

CUORE is a 741 kg array of TeO 2 bolometers for the search of neutrinoless double beta decay of 130 Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV·kg·y) will be reached, in five years of data taking CUORE will have a 1σ half life sensitivity of 10 26 y. CUORE-0 is a smaller experiment constructed to test and demonstrate the performances expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polonium–lead extractions to determine the best method for the quantification of clean lead used in low-background radiation detectors

Very sensitive detectors are used for low-background applications including the detection of environmental radioactivity, double-beta decay, and dark matter. In order to reduce the background noise enough to utilize the sensitivity of these detectors, lead with little or no alpha activity is required to form the shielding. In the past, antiquity lead shielding was used for low-background detectors because lead’s most prominent alpha-emitting isotope, 210Pb, has a short half-life. The microelectronics industry is also greatly affected by alpha activity in lead and solder, and has begun producing “clean” lead for purchase. To quantify how clean the available lead is, 210Pb and, during procedural experiments, a 209Po tracer must be physically or chemically removed from the bulk lead. A reliable procedure for chemical separations that does not use large volumes of ultra-high-purity chemicals has not yet been established. Lead was dissolved and a known amount of 209Po tracer was added. The samples were put through each of two new procedures. The first procedure was based on complete dissolution of the lead followed by a column separation. The second method investigates the utility of a pre-separation step using precipitation of the lead prior to column separation. The resulting solutions were run through strontium resin columns from Eichrom Inc., a United States Transuranium and Uranium Registries (USTUR) electrodeposition procedure, and scheduled to be alpha counted for a minimum of three days. Though neither of the tested procedures had acceptable logistics for large scale implementation, later alpha counting will show which procedure is more promising for further development

Miley, Sarah M↗

Measurements of Neutron Yield from Deuterium Plasmas at JET by Activation Techniques

The paper reports on experiments carried out at JET to test the possibility of using some activating materials (e.g. {sup 89}Y, {sup 167}Er, {sup 204}Pb, {sup 180}Hf, {sup 111}Cd, etc.) to perform multi-foil neutron activation measurements. It is shown that apart from indium other materials can be successfully used in these measurements delivering more exact information about fluxes and also energy spectra of the analysed neutrons. These and other materials have threshold energy in the interesting energy range (0.5-15 MeV) and relatively large cross sections for the nuclear reactions, but have not been used in the activation measurements supposedly because produce daughter nuclides with a relatively short half-life time. We propose then some modification of the JET activation system mainly in order to convey the activation samples faster to the detector.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Radioactive 65 Zn Contamination using 3D Position Sensitive CdZnTe Detectors

SRNL NMG Goal: In collaboration with ORNL, the aim is to identify and explore innovative technology opportunities that accelerate disposition, reduce life cycle costs, minimize worker radiation exposure, and improve worker safety and minimize program risks. • This process will include 3 glovebox systems that require personnel to dilute and package the plutonium for safe storage at WIPP. • For holdup monitoring and verification, gamma ray spectroscopy and imaging are the methods employed to achieve real time analysis of the plutonium waste. 2

Nwadeyi, Valerie E.↗

New results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0\nu\beta\beta$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for $0\nu\beta\beta$ with a TeO$_2$ exposure of 372.5 kg$\cdot$yr and a median exclusion sensitivity to a $^{130}$Te $0\nu\beta\beta$ decay half-life of $1.7\cdot 10^{25}$ yr. We find no evidence for $0\nu\beta\beta$ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of $3.2\cdot 10^{25}$ yr on the $^{130}$Te $0\nu\beta\beta$ decay half-life. In this work, we present the current status of CUORE's search for $0\nu\beta\beta$, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the $^{130}$Te two neutrino double-beta ($2\nu\beta\beta$) decay half-life.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Results of the M AJORANA D EMONSTRATOR ’s Search for Double-Beta Decay of 76 Ge to Excited States of 76 Se

76 Ge can 𝛽⁢𝛽 decay into three possible excited states of 76 Se , with the emission of two or, if the neutrino is Majorana, zero neutrinos. None of these six transitions have yet been observed. The M AJORANA D EMONSTRATOR was designed to study 𝛽⁢𝛽 decay of 76 Ge using a low background array of high purity germanium detectors. With 98.2 kg-y of isotopic exposure, the demonstrator sets the strongest half-life limits to date for all six transition modes. For 2⁢𝜈⁢𝛽⁢𝛽 to the 0$^+_1$ state of 76 Se , this search has begun to probe for the first time half-life values predicted using modern many-body nuclear theory techniques, setting a limit of 𝑇 1/2 > 1.5 × 10 24 y (90% CL).

Majorana neutrinos↗

SU-E-J-51: Dose Response of Common Solid State Detectors in Homogeneous Transverse and Longitudinal Magnetic Fields

Purpose: Solid state radiation detectors are often used for dose profiles and percent depth dose measurements. The dose response of selected solid state detectors is evaluated in varying transverse and longitudinal magnetic fields for eventual use in MR-Linac devices. Methods: A PTW 60003 and IBA PFD detector were modeled in the Monte Carlo code PENELOPE, incorporating a magnetic field which was varied in strength and oriented both transversely and longitudinally with respect to the incident photon beam. The detectors' long axis was in turn oriented either parallel or perpendicular to the photon beam. Dose to the active volume of each detector was scored, and its ratio to dose with zero magnetic field strength (dose response) was determined. Accuracy of the simulations was evaluated by measurements using both chambers taken at low field with a small electromagnet. Simulations were also performed in a water phantom to compare to the in air results. Results: Significant dose response was found in transverse field geometries, nearing 20% at 1.5T. The response is highly dependent on relative orientations to the magnetic field and photon beam, and on detector composition. Low field measurements confirm these results. In the presence of longitudinal magnetic fields, the detectors exhibit little dose response, reaching 0.5–1% at 1.5T regardless of detector orientation. Water tank simulations compared well to the in air simulations when not at the beam periphery, where in transverse magnetic fields only, the water tank simulations differed from the in air results. Conclusion: Transverse magnetic fields can cause large deviations in dose response, and are highly position orientation dependent. Comparatively, longitudinal magnetic fields exhibit little to no dose response in each detector as a function of magnetic field strength. Water tank simulations show longitudinal fields are generally easier to work with, but each detector must be evaluated separately.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the 175 Hf half-life

Hafnium-175 is a useful radioisotope for numerous applications; however, its evaluated half-life (70 ± 2 days) has a large uncertainty. To enable a new measurement of the half-life, 175 Hf was produced via proton irradiation of natural lutetium and chemically purified. The 175 Hf sample was counted approximately once a month with three high-purity germanium detectors for 13 months (~5.5 half-lives). A 133 Ba standard was counted in an identical manner to quantify systematic uncertainties over the measurement period. In conclusion, the measured 175 Hf half-life is 69.90 ± 0.07 days, in agreement with the evaluated value, but with significantly reduced uncertainty.

150 ≤ A ≤ 189↗

Search for two-proton radioactivity of {sup 19}Mg in a tracking experiment

The two-proton radioactivity of the previously unknown {sup 19}Mg ground-state is observed by tracking the decay products in-flight. The trajectories of the 2p-decay products, {sup 17}Ne+p+p, have been measured by using tracking micro-strip detectors which allowed to reconstruct the 2p-decay vertices and fragment correlations. The half-life of {sup 19}Mg deduced from the measured vertex distribution is 4.0(15) ps in the system of {sup 19}Mg. The Q-value of the 2p-decay of the {sup 19}Mg ground-state inferred from the measured p-p-{sup 17}Ne correlations is 0.75(5) MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗

Half-life of {sup 151}Sm remeasured

The half-life of {sup 151}Sm was redetermined and compared with literature values. A {sup 151}Sm{sub 2}O{sub 3} sample was produced by exposing {sup 150}Sm{sub 2}O{sub 3} to the high neutron flux of the heavy water research reactor at the China Institute of Atomic Energy (CIAE). The number of atoms and the activity of {sup 151}Sm in the sample were measured by thermal ionization mass spectrometry (TIMS) and liquid scintillation counting (LSC), respectively. The half-life of {sup 151}Sm determined in this work is 96.6 yr, with a standard uncertainty of 2.4 yr based on a quadratic summation of the uncertainty components from the measurements of the number of atoms and the activity of {sup 151}Sm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High stereographic resolution texture and residual stress evaluation using time-of-flight neutron diffraction

Neutron diffraction texture measurements provide bulk averaged textures with excellent grain orientation statistics, even for large-grained materials, owing to the probed volume being of the order of 1 cm 3 . Furthermore, crystallographic parameters and other valuable microstructure information such as phase fraction, coherent crystallite size, root-mean-square microstrain, macroscopic or intergranular strain and stress, etc. can be derived from neutron diffractograms. A procedure for combined high stereographic resolution texture and residual stress evaluation was established on the pulsed-neutron-source-based engineering materials diffractometer TAKUMI at the Materials and Life Science Experimental Facility of the Japan Proton Accelerator Research Center, through division of the neutron detector panel regions. Pole figure evaluation of a limestone standard sample with a well known texture suggested that the precision obtained for texture measurement is comparable to that of the established neutron beamlines utilized for texture measurement, such as the HIPPO diffractometer at the Los Alamos Neutron Science Center (New Mexico, USA) and the D20 angle-dispersive neutron diffractometer at the Institut Laue–Langevin (Grenoble, France). A high-strength martensite–austenite multilayered steel was employed for further verification of the reliability of simultaneous Rietveld analysis of multiphase textures and macro stress tensors. By using a texture-weighted geometric mean micromechanical (BulkPathGEO) model, a macro stress tensor analysis with a plane stress assumption showed a rolling direction–transverse direction (RD–TD) in-plane compressive stress (about –330 MPa) in the martensite layers and an RD–TD in-plane tensile stress (about 320 MPa) in the austenite layers. The phase stress partitioning was ascribed mainly to the additive effect of the volume expansion during martensite transformation and the linear contraction misfit between austenite layers and newly transformed martensite layers during the water quenching process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poster — Thur Eve — 27: Flattening Filter Free VMAT Quality Assurance: Dose Rate Considerations for Detector Response

Introduction: Radiation detector responses can be affected by dose rate. Due to higher dose per pulse and wider range of mu rates in FFF beams, detector responses should be characterized prior to implementation of QA protocols for FFF beams. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. This study looks at the dose per pulse variation throughout a 3D volume for typical VMAT plans and the response characteristics for a variety of detectors, and makes recommendations on the design of QA protocols for FFF VMAT QA. Materials and Methods: Linac log file data and a simplified dose calculation algorithm are used to calculate dose per pulse for a variety of clinical VMAT plans, on a voxel by voxel basis, as a function of time in a cylindrical phantom. Diode and ion chamber array responses are characterized over the relevant range of dose per pulse and dose rate. Results: Dose per pulse ranges from <0.1 mGy/pulse to 1.5 mGy/pulse in a typical VMAT treatment delivery using the 10XFFF beam. Diode detector arrays demonstrate increased sensitivity to dose (+./− 3%) with increasing dose per pulse over this range. Ion chamber arrays demonstrate decreased sensitivity to dose (+/− 1%) with increasing dose rate over this range. Conclusions: QA protocols should be designed taking into consideration inherent changes in detector sensitivity with dose rate. Neglecting to account for changes in detector response with dose per pulse can lead to skewed QA results.

60 APPLIED LIFE SCIENCES↗

Measurements of the cosmic-ray Be/B ratio and the age of cosmic rays

The ratio Be/B depends on whether the confinement time of cosmic rays in the Galaxy is long or short compared to the radioactive half-life of Be-10. We report observations of this ratio which were obtained with a dE/dx-Cerenkov detector launched into a polar orbit on OGO-6 as part of the Caltech Solar and Galactic Cosmic Ray Experiment. Be/B ratios were determined for various rigidity thresholds up to 15 GV. We find no statistically significant rigidity dependence of the ratio, which is 0.41 plus or minus 0.02 when averaged over all observed cutoffs. Additional calculations suggest that if the present fragmentation parameters are correct, then the lifetime of cosmic rays in the Galaxy is less then 10 m.y.

Brown, J. W.↗

Fire Detection Tradeoffs as a Function of Vehicle Parameters

Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.

microgravity↗

Fire Detection Tradeoffs as a Function of Vehicle Parameters

Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.

microgravity↗

Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches

We report that large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay (0νββ) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas- or liquid-phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomena. The key challenge to extending this technology to detectors well beyond the ton scale is the acquisition of the Xe itself. We describe the motivation for extending Xe time-projection chambers to the kton scale and possible avenues for Xe acquisition that avoid existing supply chains. If acquisition of Xe in the required quantities is successful, kton-scale detectors of this type could enable a new generation of experiments, including searches for 0νββ at half-life sensitivities as long as 10 30 yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗