Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEVEL WIDTHS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A theoretical and experimental study of wood planer noise and its control

A combined analytical and experimental study of wood planer noise is made and the results applied to the development of practical noise control techniques. The dominant mechanisms of sound generation are identified and an analysis is presented which accurately predicts the governing levels of noise emission. Planing operations in which the length of the board is much greater than the width are considered. The dominant source of planer noise is identified as the board being surfaced, which is set into vibration by the impact of cutterhead knives. This is determined from studies made both in the laboratory and in the field concerning the effect of board width on the resulting noise, which indicate a six decibel increase in noise level for each doubling of board width. The theoretical development of a model for board vibration defines the vibrational field set up in the board and serves as a guide for cutterhead redesign.

Stewart, J. S.↗

Resolving charm and bottom quark masses in precision Higgs boson analyses

Masses of the charm and bottom quarks are important inputs to precision calculations of Higgs boson observables, such as its partial widths and branching fractions. They constitute a major source of theory uncertainties that needs to be better understood and reduced in light of future high-precision measurements. Conventionally, Higgs boson observables are calculated in terms of $m_c$ and $m_b$, whose values are obtained by averaging over many extractions from low-energy data. This approach may ultimately be unsatisfactory, since $m_c$ and $m_b$ as single numbers hide various sources of uncertainties involved in their extractions some of which call for more careful estimations, and also hide correlations with additional inputs such as $\alpha_s$. Aiming at a more detailed understanding of the uncertainties from $m_c$ and $m_b$ in precision Higgs boson analyses, we present a calculation of Higgs boson observables in terms of low-energy observables, which reveals concrete sources of uncertainties that challenge sub-percent-level calculations of Higgs boson partial widths.

Petrov, Alexey A.↗

Measurement of the Higgs boson mass and width using the four-lepton final state in proton-proton collisions at $\sqrt{s}$ =13 TeV

A measurement of the Higgs boson mass and width via its decay to two 𝑍 bosons is presented. Proton-proton collision data collected by the CMS experiment, corresponding to an integrated luminosity of 138 fb −1 at a center-of-mass energy of 13 TeV, is used. The invariant mass distribution of four leptons in the on-shell Higgs boson decay is used to measure its mass and constrain its width. This yields the most precise single measurement of the Higgs boson mass to date, 125.04 ± 0.12 GeV, and an upper limit on the width Γ 𝐻 < 330 MeV at 95% confidence level. A combination of the on- and off-shell Higgs boson production decaying to four leptons is used to determine the Higgs boson width, assuming that no new virtual particles affect the production, a premise that is tested by adding new heavy particles in the gluon fusion loop model. This result is combined with a previous CMS analysis of the off-shell Higgs boson production with decay to two leptons and two neutrinos, giving a measured Higgs boson width of 3.0$^{+2.0}_{−1.5}$ MeV, in agreement with the standard model prediction of 4.1 MeV. The strength of the off-shell Higgs boson production is also reported. The scenario of no off-shell Higgs boson production is excluded at a confidence level corresponding to 3.8 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Phase-Disposition PWM Enabled Model Predictive Control for a Nine-Level Inner-Interleaved Hybrid Multilevel Converter

This article brings forward a phase-disposition pulse width modulation enabled model predictive control (PDPWM-MPC) for a nine-level inner-interleaved hybrid multilevel converter (9L-IHMC). Firstly, three layers of virtual space vector diagrams (VSVD) are established based on the sign patterns of the original and virtual reference vectors in the abcframe, respectively, to achieve the phase-disposition pulse width modulation (PD-PWM) in a non-independent three-phase way. Then, three adjacent virtual vectors in the third-layer VSVD, together with their optimized duty cycles, are applied to guarantee the optimal current tracking. Finally, through the use of the duty cycle alternation approach, dc-link and floating capacitors voltages are balanced and circulating currents are mitigated as well. The proposed PDPWM-MPC can not only enable the decoupling of the low-and high-frequency stages in the 9L-IHMC, but also reduce both output current ripples and computational burden. In addition, it can achieve a constant equivalent switching frequency and address the disproportion of power losses associated with the PD-PWM. Here, both simulations and experiments on a silicon carbide device-based prototype substantiate the effectiveness of the proposed control strategy.

42 ENGINEERING↗

Search for resonant $ \mathrm{t}\overline{\mathrm{t}} $ production in lepton+jets events in pp collisions at $ \sqrt{s}=7 $ TeV

A model-independent search for the production of heavy resonances decaying into top-antitop quark pairs is presented. The search is based on events containing one lepton (muon or electron) and at least two jets selected from data samples corresponding to an integrated luminosity of 4.4-5.0 inverse femtobarns collected in pp collisions at sqrt(s) = 7 TeV. Results are presented from the combination of two dedicated searches optimized for boosted production and production at threshold. No excess of events is observed over the expected yield from the standard model processes. Topcolor Z' bosons with narrow (wide) width are excluded at 95% confidence level for masses below 1.49 (2.04) TeV and an upper limit of 0.3 (1.3) pb or lower is set on the production cross section times branching fraction for resonance masses above 1 TeV. Kaluza-Klein excitations of a gluon with masses below 1.82 TeV (at 95% confidence level) in the Randall-Sundrum model are also excluded, and an upper limit of 0.7 pb or lower is set on the production cross section times branching fraction for resonance masses above 1 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy levels, radiative rates, and lifetimes for transitions in W LVIII

Energy levels and radiative rates are reported for transitions in Cl-like W LVIII. Configuration interaction (CI) has been included among 44 configurations (generating 4978 levels) over a wide energy range up to 363 Ryd, and the general-purpose relativistic atomic structure package (GRASP) adopted for the calculations. Since no other results of comparable complexity are available, calculations have also been performed with the flexible atomic code (FAC), which help in assessing the accuracy of our results. Energies are listed for the lowest 400 levels (with energies up to ∼98 Ryd), which mainly belong to the 3s{sup 2}3p{sup 5}, 3s3p{sup 6}, 3s{sup 2}3p{sup 4}3d, 3s{sup 2}3p{sup 3}3d{sup 2}, 3s3p{sup 4}3d{sup 2}, 3s{sup 2}3p{sup 2}3d{sup 3}, and 3p{sup 6}3d configurations, and radiative rates are provided for four types of transitions, i.e. E1, E2, M1, and M2. Our energy levels are assessed to be accurate to better than 0.5%, whereas radiative rates (and lifetimes) should be accurate to better than 20% for a majority of the strong transitions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Alignment of the CLAS12 central hybrid tracker with a Kalman Filter

Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5 T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10 µm, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fano effect dominance over Coulomb blockade in transport properties of parallel coupled quantum dot system

Theoretical study of the Coulomb blockade effect on transport properties (Transmission Probability and I-V characteristics) for varied configuration of coupled quantum dot system has been studied by using Non Equilibrium Green Function(NEGF) formalism and Equation of Motion(EOM) method in the presence of magnetic flux. The self consistent approach and intra-dot Coulomb interaction is being taken into account. As the key parameters of the coupled quantum dot system such as dot-lead coupling, inter-dot tunneling and magnetic flux threading through the system can be tuned, the effect of asymmetry parameter and magnetic flux on this tuning is being explored in Coulomb blockade regime. The presence of the Coulomb blockade due to on-dot Coulomb interaction decreases the width of transmission peak at energy level ε + U and by adjusting the magnetic flux the swapping effect in the Fano peaks in asymmetric and symmetric parallel configuration sustains despite strong Coulomb blockade effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Subwavelength optical spatial solitons and three-dimensional localization in disordered ferroelectrics: Toward metamaterials of nonlinear origin

We predict the existence of a class of multidimensional light localizations in out-of-equilibrium ferroelectric crystals. In two dimensions, the nondiffracting beams form at an arbitrary low-power level and propagate even when their width is well below the optical wavelength. In three dimensions, a subwavelength light bullet is found. The effects emerge when compositionally disordered crystals are brought to their metastable glassy state, and leading to the suppression of evanescent waves, they can have a profound impact on super-resolved imaging and ultradense optical storage, resembling metamaterials in many ways.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental M 1 response of 40 Ar as a benchmark for neutrino-nucleus scattering calculations

The excitation of atomic nuclei via magnetic dipole transitions is closely related to the inelastic neutral-current neutrino-nucleus (NC-νA) scattering process due to the similarity of the transition operators. NC-νA-scattering serves for the detection of supernova neutrinos and poses a significant source of background in modern liquid-argon based high-energy neutrino detection experiments. To enable tests of the reliability of predictions for neutrino-nucleus scattering, the magnetic dipole response of 40 Ar below 7.7 MeV was characterized in a nuclear resonance fluorescence experiment using quasimonoenergetic γ-ray beams. The linear polarization of the beams allowed for assignments of electric or magnetic character to previously known dipole excitations. A total magnetic dipole strength of $0.36$ $^{+0.04}_{–0.05}$ $μ$ $^{2}_{N}$ was identified in the energy range of the present experiment. Combined with data from previous measurements, the full magnetic dipole strength of 40 Ar below the neutron separation threshold was investigated. Due to the low background in the energy range within the bandwidth of the γ-ray beams, the previous sensitivity limit was improved. Furthermore, a large-scale nuclear shell model calculation in the sd–fp space satisfactorily agrees with the data in terms of excitation energies and strengths of the observed 1 + states.

39 ≤ A ≤ 58↗

Single-shot temporal characterization of kilojoule-level, picosecond pulses on OMEGA EP

To achieve a variety of experimental conditions, the OMEGA EP laser provides kilojoule-level pulses over a pulse-width range of 0.6 to 100 ps. Precise knowledge of the pulse width is important for laser system safety and the interpretation of experimental results. This paper describes the development and implementation of a single-shot, ultrashort-pulse measurement diagnostic, which provides an accurate characterization of the output pulse shape. We also present a brief overview of the measurement algorithm; discuss design considerations necessary for implementation in a complex, user-facility environment; and review the results of the diagnostic commissioning shots, which demonstrated excellent agreement with predictions.

36 MATERIALS SCIENCE↗

SU-C-BRB-02: Symmetric and Asymmetric MLC Based Lung Shielding and Dose Optimization During Translating Bed TBI

Purpose: The primary aim was to introduce a dose optimization method for translating bed total body irradiation technique that ensures lung shielding dynamically. Symmetric and asymmetric dynamic MLC apertures were employed for this purpose. Methods: The MLC aperture sizes were defined based on the radiological depth values along the divergent ray lines passing through the individual CT slices. Based on these RD values, asymmetrically shaped MLC apertures were defined every 9 mm of the phantom in superior-inferior direction. Individual MLC files were created with MATLAB™ and were imported into Eclipse™ treatment planning system for dose calculations. Lungs can be shielded to an optimum level by reducing the MLC aperture width over the lungs. The process was repeated with symmetrically shaped apertures. Results: Dose-volume histogram (DVH) analysis shows that the asymmetric MLC based technique provides better dose coverage to the body and optimum shielding of the lungs compared to symmetrically shaped beam apertures. Midline dose homogeneity is within ±3% with asymmetric MLC apertures whereas it remains within ±4.5% with symmetric ones (except head region where it drops down to −7%). The substantial over and under dosage of ±5% at tissue interfaces has been reduced to ±2% with asymmetric MLC technique. Lungs dose can be reduced to any desired limit. In this experiment lungs dose was reduced to 80% of the prescribed dose, as was desired. Conclusion: The novel asymmetric MLC based technique assures optimum shielding of OARs (e.g. lungs) and better 3-D dose homogeneity and body-dose coverage in comparison with the symmetric MLC aperture optimization. The authors acknowledge the financial and infrastructural support provided by Pakistan Institute of Engineering & Applied Sciences (PIEAS), Islamabad and Aga Khan University Hospital (AKUH), Karachi during the course of this research project. Authors have no conflict of interest with any national / international body for the presented work.

60 APPLIED LIFE SCIENCES↗

Setup and Testing of the RS105 Wire Array Pulser

The report covers the RS105 Wire Array Pulser testbed. The setup of the wire array at Reapplication, building 996, is laid out. Setup instructions are provided. Details of the commissioning test are given. Measurement data from the commissioning test shows the field output of the array exceeds 50 kV/m and that tuning the pulser output with a peaking switch can provide a rise time of ~2.3 ns and a pulse width of ~23 ns. The field levels and timeframes shown are within the tolerance conditions of

42 ENGINEERING↗

Parameterization of spectrum

Many radars used for wind sounding generate Doppler power spectra as output. For compact data archiving purposes, as well as for data analysis, several parameters were produced to characterize each spectrum. The parameters chosen were noise level, echo signal strength, velocity, and width. Because the derived parameters may be the only quantities available for future analysis, it was important that they did not contain biases imposed by the derivation techniques. This consideration led to a processing scheme in which the parameters were derived independently for each spectrum.

Riddle, A. C.↗

A C-band scatterometer for remote sensing the air-sea interface

An airborne C-band scatterometer system (C-Scat) has been developed to remotely sense ocean surface winds and improve upon the present understanding of the relationship between normalized radar cross section (NRCS) and ocean surface roughness influences such as wind speed and direction, wave height and slope, and the air-sea temperature difference. The scatterometer utilizes a unique frequency-steered microstrip array antenna that is installed beneath the fuselage of an airplane. The antenna is electronically scanned in elevation, from 20 deg to 50 deg off-nadir, and mechanically spins in azimuth. The system is capable of measuring ocean surface NRCS from altitudes as high as 25,000 ft. The transmitter and receiver operate from 4.98 to 5.7 GHz. System parameters such as transmitter pulse width, pulse repetition frequency, output power level, and receiver bandwidth are programmable. Received signals can be averaged and displayed in real time and are stored on a Winchester disk drive for post-flight analysis. Preliminary flight data that demonstrates the instrument's performance is presented.

Mclaughlin, David J.↗

Simulations and case study of X-59 low-booms propagated through measured atmospheric profiles

NASA's X-59 Quiet Supersonic Technology aircraft will soon be used to collect data to support the development of a dose-response relationship between low-boom level and human perception. The X-59's low-boom level will depend on aircraft conditions and trajectory, which can be controlled, and on atmospheric conditions, which cannot be controlled. To assess variability in low-boom levels produced by realistic atmospheres, NASA's PCBoom code was used to simulate propagation of an X-59 nearfield pressure condition through atmospheric profiles measured during NASA's Quiet Supersonic Flights 2018 (QSF18) test. Despite QSF18 lasting only 11 days, substantial weather variability occurred including snow and record high temperatures. A PL range of about 8.5 dB was predicted due to the QSF18 atmospheric variability. These results demonstrate the necessity for X-59's flight condition to be adjusted based on atmospheric conditions in order to achieve desired loudness levels during community surveys. Undertrack booms' Perceived Levels (PL) were predicted not to exceed 75 dB, X-59's target level in a standard atmosphere. Attenuation rate, ray tube area, path length, and other quantities are presented throughout propagation for the atmospheres that produce the loudest and quietest booms. Humidity differences below 15kft were a primary driver of the PL differences.

X-59↗

SNS LINAC MODULATOR OPERATIONAL HISTORY AND PERFOMANCE

Fourteen High Voltage Converter Modulators (HVCM) were initially installed at the Spallation Neutron Source Linear Accelerator (SNS Linac) at the Oak Ridge National Laboratory in 2005. A fifteenth HVCM was added in 2009. Each modulator provides a pulse of up to 140 kV at a maximum width of 1.35 msec. Peak power level is 11 MW with an 8% duty factor. The HVCM system must be available for neutron production (NP) 24/7 with the exception being two, 6-week maintenance periods per year. HVCM reliability is one of the most important factors to maximize Linac availability and achieve SNS performance goals. During the last few years several modifications have been implemented to improve the overall system reliability. This paper presents operational history of the HVCM systems and examines failure mode statistical data since the modulators began operating at 60 Hz. System enhancements and upgrades aimed at providing long term reliable operation with minimal down time are also discussed in the paper.

43 PARTICLE ACCELERATORS↗

An investigation into factors affecting the precision of CT radiation dose profile width measurements using radiochromic films

Purpose: To investigate the impact of x-ray beam energy, exposure intensity, and flat-bed scanner uniformity and spatial resolution on the precision of computed tomography (CT) beam width measurements using Gafchromic XR-QA2 film and an off-the-shelf document scanner. Methods: Small strips of Gafchromic film were placed at isocenter in a CT scanner and exposed at various x-ray beam energies (80–140 kVp), exposure levels (50–400 mA s), and nominal beam widths (1.25, 5, and 10 mm). The films were scanned in reflection mode on a Ricoh MP3501 flat-bed document scanner using several spatial resolution settings (100 to 400 dpi) and at different locations on the scanner bed. Reflection measurements were captured in digital image files and radiation dose profiles generated by converting the image pixel values to air kerma through film calibration. Beam widths were characterized by full width at half maximum (FWHM) and full width at tenth maximum (FWTM) of dose profiles. Dependences of these parameters on the above factors were quantified in percentage change from the baselines. Results: The uncertainties in both FWHM and FWTM caused by varying beam energy, exposure level, and scanner uniformity were all within 4.5% and 7.6%, respectively. Increasing scanner spatial resolution significantly increased the uncertainty in both FWHM and FWTM, with FWTM affected by almost 8 times more than FWHM (48.7% vs 6.5%). When uncalibrated dose profiles were used, FWHM and FWTM were over-estimated by 11.6% and 7.6%, respectively. Narrower beam width appeared more sensitive to the film calibration than the wider ones (R{sup 2} = 0.68 and 0.85 for FWHM and FWTM, respectively). The global and maximum local background variations of the document scanner were 1.2%. The intrinsic film nonuniformity for an unexposed film was 0.3%. Conclusions: Measurement of CT beam widths using Gafchromic XR-QA2 films is robust against x-ray energy, exposure level, and scanner uniformity. With proper film calibration and scanner resolution setting, it can provide adequate precision for meeting ACR and manufacturer’s tolerances for the measurement of CT dose profiles.

60 APPLIED LIFE SCIENCES↗