Apollo logistics support systems molab studies. digital command system for a lunar mobile laboratory
Digital command system for lunar mobile laboratory /Molab/ - Apollo Logistics Support System
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Digital command system for lunar mobile laboratory /Molab/ - Apollo Logistics Support System
The critical elements of an autonomous video rendezvous and docking system were built and used successfully in a physical laboratory simulation. The laboratory system demonstrated that a small, inexpensive electronic package and a flight computer of modest size can analyze television images to derive guidance information for spacecraft. In the ultimate application, the system would use a docking aid consisting of three flashing lights mounted on a passive target spacecraft. Television imagery of the docking aid would be processed aboard an active chase vehicle to derive relative positions and attitudes of the two spacecraft. The demonstration system used scale models of the target spacecraft with working docking aids. A television camera mounted on a 6 degree of freedom (DOF) simulator provided imagery of the target to simulate observations from the chase vehicle. A hardware video processor extracted statistics from the imagery, from which a computer quickly computed position and attitude. Computer software known as a Kalman filter derived velocity information from position measurements.
In April 1980, a Space Shuttle Extravehicular Mobility Unit (EMU) was destroyed in a flash fire during a functional test in the Johnson Space Center's crew systems laboratory. During this lecture, retired Exploration Portable Life Support System (xPLSS) Operations Manager Joseph T. Nowetner Jr. discussed what happened to cause this failure, what safety message resulted from it, lessons learned from these mistakes, and how to leverage earned knowledge.
The paper describes a small-scale laboratory system, called the Large-Angle Magnetic Suspension Test Fixture (LAMSTF), constructed at NASA Langley Research Center in order to explore and develop technology required for the magnetic suspension of objects over large ranges of orientation. The LAMSTF hardware comprises five electromagnets in a circular arrangement, each driven from a separate bipolar power amplifier. The suspended element is a cylindrical axially magnetized permanent magnet core, within an aluminum tube. The element, which is 'levitated' by repulsive forces, is stabilized in five degrees-of-freedom, with rotation about the cylinder axis not controlled. The controller accommodates the changes in magnetic coupling between the electromagnets and the suspended element by real-time adaptation of a decoupling matrix. The paper presents performance measurements demonstrating that the major design objective of the 360 deg rotation was accomplished.
Pratt & Whitney Rocketdyne has developed a real-time engine/vehicle system integrated health management laboratory, or testbed, for developing and testing health management system concepts. This laboratory simulates components of an integrated system such as the rocket engine, rocket engine controller, vehicle or test controller, as well as a health management computer on separate general purpose computers. These general purpose computers can be replaced with more realistic components such as actual electronic controllers and valve actuators for hardware-in-the-loop simulation. Various engine configurations and propellant combinations are available. Fault or failure insertion capability on-the-fly using direct memory insertion from a user console is used to test system detection and response. The laboratory is currently capable of simulating the flow-path of a single rocket engine but work is underway to include structural and multiengine simulation capability as well as a dedicated data acquisition system. The ultimate goal is to simulate as accurately and realistically as possible the environment in which the health management system will operate including noise, dynamic response of the engine/engine controller, sensor time delays, and asynchronous operation of the various components. The rationale for the laboratory is also discussed including limited alternatives for demonstrating the effectiveness and safety of a flight system.
In the laboratory, hollow cathode-based plasma contactors have been observed to both emit and collect ampere-level electron currents with low impedance. The laboratory behavior of hollow cathode-based plasma contactors and the limited space experience with hollow cathodes suggest that, for many applications, a hollow cathode-based plasma contactor is the ideal device to provide electrical connection with the space plasma. In order to confidently extend the laboratory experience to the low-earth-orbit environment, a series of plasma contactor computer models has been developed. Calculations show that a hollow cathode plasma contactor that collects 0.5 A in the laboratory will only collect 2.4 mA in space. The simplest way to boost the collected current is to increase the gas flow. A mole of gas is enough to collect ampere level currents for 5-1/2 hours.
The performance and design requirements for a Color Graphic Camera System are presented. The system is a functional part of the Earth Observation Department Laboratory System (EODLS) and will be interfaced with Image Analysis Stations. It will convert the output of a raster scan computer color terminal into permanent, high resolution photographic prints and transparencies. Images usually displayed will be remotely sensed LANDSAT imager scenes.
The latest upgrade to the Aerospace Energy Systems Laboratory (AESL) is described. The AESL is a distributed digital system consisting of a central system and battery servicing stations connected by a high-speed serial data bus. The entire system is located in two adjoining rooms; the bus length is approximately 100 ft. Each battery station contains a digital processor, data acquisition, floppy diskette data storage, and operator interfaces. The operator initiates a servicing task and thereafter the battery station monitors the progress of the task and terminates it at the appropriate time. The central system provides data archives, manages the data bus, and provides a timeshare interface for multiple users. The system also hosts software production tools for the battery stations and the central system.
Here, we present an analysis of the diagnostic technologies that were used to identify historical outbreaks of ebola virus disease and consider systematic surveillance strategies that may greatly reduce the peak size of future epidemics. We observe that clinical signs and symptoms alone are often insufficient to recognize index cases of diseases of global concern against the considerable background infectious disease burden that is present throughout the developing world. We propose a simple sampling strategy to enrich in especially dangerous pathogens with a low background for molecular diagnostics by targeting blood borne pathogens in the healthiest age groups. With existing multiplexed diagnostic technologies, such a system could be combined with existing public health screening and reference laboratory systems for malaria, dengue, and common bacteremia or be used to develop such an infrastructure in less-developed locations. Because the needs for valid samples and accurate recording of patient attributes are aligned with needs for global biosurveillance, local public health needs, and improving patient care, co-development of these capabilities appears to be quite natural, flexible, and extensible as capabilities, technologies, and needs evolve over time. Furthermore, implementation of multiplexed diagnostic technologies to enhance fundamental clinical lab capacity will increase public health monitoring and biosurveillance as a natural extension.
The second National Renewable Energy Laboratory (NREL) Wind Energy Systems Engineering Workshop was held in Broomfield, Colorado, from January 29 to February 1, 2013. The event included a day-and-a-half workshop exploring a wide variety of topics related to system modeling and design of wind turbines and plants. Following the workshop, 2 days of tutorials were held at NREL, showcasing software developed at Sandia National Laboratories, the National Aeronautics and Space Administration's Glenn Laboratories, and NREL. This document provides a brief summary of the various workshop activities and includes a review of the content and evaluation results from attendees.
The Hanford Waste Treatment and Immobilization Plant (WTP) will process and stabilize waste that is stored in underground tanks on the Hanford Site. At the WTP, the tank waste will be combined with glass-forming and modifying additives to form an aqueous and solid mixture called melter feed, which will then be vitrified in joule-heated melters. A small-scale melter system, the continuous laboratory-scale melter (CLSM), is designed to operate with a continuous feeding process while periodically pouring glass product and collecting off-gas. Two CLSMs were constructed: one in a non-radioactive environment for processing waste simulants and another in a fume hood capable of handling radioactive material for processing actual Hanford tank waste. The waste sample received for vitrification in the CLSM was from Hanford tank 241-AP-107. Approximately 12 liters of melter-feed slurry was vitrified into 7 kilograms of glass product over the course of 10 hours of charging to the CLSM. The partitioning of technetium-99 in the product streams was used to calculate the technetium-99 recovery and help determine when the vitrification process had reached a steady state. The average single-pass retention of technetium-99 in the glass product was then calculated for the processing of AP-107 waste in the CLSM system. (authors)
In order to characterize the behavior of tunable diode lasers (TDL), the first step in the project involved the redesign of the TDL system here at the University of Tennessee Molecular Systems Laboratory (UTMSL). Having made these changes it was next necessary to optimize the new optical system. This involved the fine adjustments to the optical components, particularly in the monochromator, to minimize the aberrations of coma and astigmatism and to assure that the energy from the beam is focused properly on the detector element. The next step involved the taking of preliminary data. We were then ready for the analysis of the preliminary data. This required the development of computer programs that use mathematical techniques to look for signatures of chaos. Commercial programs were also employed. We discovered some indication of high dimensional chaos, but were hampered by the low sample rate of 200 KSPS (kilosamples/sec) and even more by our sample size of 1024 (1K) data points. These limitations were expected and we added a high speed data acquisition board. We incorporated into the system a computer with a 40 MSPS (million samples/sec) data acquisition board. This board can also capture 64K of data points so that were then able to perform the more accurate tests for chaos. The results were dramatic and compelling, we had demonstrated that the lead salt diode laser had a chaotic frequency output. Having identified the chaotic character in our TDL data, we proceeded to stage two as outlined in our original proposal. This required the use of an Occasional Proportional Feedback (OPF) controller to facilitate the control and stabilization of the TDL system output. The controller was designed and fabricated at GSFC and debugged in our laboratories. After some trial and error efforts, we achieved chaos control of the frequency emissions of the laser. The two publications appended to this introduction detail the entire project and its results.
Secondary organic aerosols (SOA) formed in the atmosphere from the condensation of semivolatile oxidation products are a significant component of airborne particles which have deleterious effects on health, visibility, and climate. In this study, atmospheric solids analysis probe mass spectrometry (ASAP-MS) is applied for the first time to the identification of organics in particles from laboratory systems as well as from ambient air. SOA were generated in the laboratory from the ozonolysis of r-pinene and isoprene, as well as from NO3 oxidation of r-pinene, and ambient air was sampled at forested and suburban sites. Particles were collected by impaction on ZnSe disks, analyzed by Fourier transform-infrared spectroscopy (FT-IR) and then transferred to an ASAP-MS probe for further analysis. ASAP-MS data for the laboratory-generated samples show peaks from wellknown products of these reactions, and higher molecular weight oligomers are present in both laboratory and ambient samples. Oligomeric products are shown to be present in the NO3 reaction products for the first time. A major advantage of this technique is that minimal sample preparation is required, and complementary information from nondestructive techniques such as FT-IR can be obtained on the same samples. In addition, a dedicated instrument is not required for particle analysis. This work establishes that ASAP-MS will be useful for identification of organic components of SOA in a variety of field and laboratory studies.
Designing software systems, like all design activities, is a knowledge-intensive task. Several studies have found that the predominant cause of failures among system designers is lack of knowledge: knowledge about the application domain, knowledge about design schemes, knowledge about design processes, etc. The goal of domain-specific software design systems is to explicitly represent knowledge relevant to a class of applications and use it to partially or completely automate various aspects of the designing systems within that domain. The hope is that this would reduce the intellectual burden on the human designers and lead to more efficient software development. In this paper, we present a domain-specific system built on top of KASE, a knowledge-assisted software engineering environment being developed at the Stanford Knowledge Systems Laboratory. We introduce the main ideas underlying the construction of domain specific systems within KASE, illustrate the application of the idea in the synthesis of a system for tracking aircraft from radar signals, and discuss some of the issues in constructing domain-specific systems.
The Hanford Tank Waste Treatment and Immobilization Plant is being constructed to vitrify the nuclear waste stored in underground tanks on the Hanford Site. Through this conversion process, waste components become partitioned into one of two product streams: glass and off-gas, including condensate. A small-scale melter system is appropriate for analyzing the waste-to-glass process because it does not require the high volumes of input waste or resource commitment of a large-scale melter system while providing dynamic information that can be difficult to determine from batch reactions in a crucible system. A continuous laboratory-scale melter (CLSM) was sized to collect the relevant process and chemical information from obtainable volumes of Hanford tank waste and designed to operate with a continuous feeding process while periodically pouring glass product and collecting off-gas. Two CLSMs were constructed: one in a non-radioactive environment for processing waste simulants and another in a fume hood capable of handling radioactive material for processing actual Hanford tank waste. Multiple waste simulants were first tested in the non-radioactive CLSM to determine the processability and desired operating window for actual tank waste. About 12 liters of real waste from Hanford tank 241-AP-105 were received, filtered, and ion exchanged for removal of Cs-137. This quantity of waste was vitrified into 9.5 kg of glass product over the course of ∼15 hours of feeding to the CLSM. (authors)
Information Systems Laboratories (ISL) has designed a new single, integrated, waste management and control system to administer all aspects of nuclear waste management. The overriding goal of the initiative is to provide federal, state, and local agencies with operational awareness, management, and programmatic support for all functions related to nuclear waste management. Over decades of waste management federal agencies have sponsored or directly paid for the development, operation, and control of multiple systems to track and control its waste - with varied success. Multiple contractors have generated disparate control systems/databases and literally mountains of data. Past approaches have not provided a single, integrated, real time data management system. ISL's analysis of past failed efforts has reveal four common symptoms: - Control/management systems that are not compatible; - Programmatic costs that increase with systems use and re-work; - Systems focused on specific sets of data; - Inaccurate or outdated data sets. An integrated waste management and control system that collects and displays real-time, accurate inventory, waste container certification, transportation certification, emplacement, and shipment related data improve operational awareness and overcomes these limitations. Using its vast knowledge and experience in developing numerous waste tracking and management systems, ISL has leveraged its own in-house knowledge and gathered requests from stakeholders all across the industry to design a system that meets the needs of users at all levels of the nuclear waste management process. Using the highly successful and widely used Waste Data System (WDS) designed for the Waste Isolation Pilot Plant as a core component, ISL has designed a system that greatly expands on the functionality of the WDS to exceed its current focus of management of Transuranic Waste shipments. The new system is designed to provide the ability to track a wide range of waste types from Transuranic, High Level, Low Level, Mixed, and any nuclear related material. The main focus of the system is to provide federal regulators a comprehensive and real-time oversight into the handling of all nuclear waste materials. Oversight activities include, but are not limited to, strategy development, projections, metrics, incentive development, tracking, budget review, government cost estimating, and integrated schedules. The major components of the system are summarized below: - The Centralized Waste Management System (CWMS), which will include assimilating and validating known sources of data into the CWMS. - The programmatic reporting support component, which will handle queries from regulators, track compliance with regulatory requirements, and maintain the dashboard for federal management. - Both the CWMS and the programmatic reporting support component will use a standard set of business rules that govern system operations and allow site and program specific needs and limits for all waste programs and types to be captured and maintained. This presentation will provide details of each component of the system detailing its use, interfaces with other components, and value to stakeholders. (authors)
The Sustainable Forward Operating Base (FOB) Nuclear Power Evaluation was developed by the Idaho National Laboratory Systems Engineering Department to support the Defense Advanced Research Projects Agency (DARPA) in assessing and demonstrating the viability of deploying small-scale reactors in support of military operations in theatre. This document provides a brief explanation of how to access and use the Sustainable FOB Nuclear Power Evaluation utility to view assessment results as input into developing and integrating the program elements needed to create a successful demonstration.
R2R processing is used to manufacture a wide range of products for various applications which span many industrial business sectors. The overall R2R methodology has been in use for decades and this continuous technique traditionally involves deposition of material(s) onto moving webs, carriers or other continuous belt-fed or conveyor-based processes that enable successive steps to build a final version which serves to support the deposited materials. Established methods that typify R2R processing include tape casting, silk-screen printing, reel-to-reel vacuum deposition/coating, and R2R lithography. Products supported by R2R manufacturing include micro-electronics, electro-chromic window films, PVs, fuel cells for energy conversion, battery electrodes for energy storage, and barrier and membrane materials. Due to innovation in materials and process equipment, high-quality yet very low-cost multilayer technologies have the potential to be manufactured on a very cost-competitive basis. To move energy-related products from high-cost niche applications to the commercial sector, the means must be available to enable manufacture of these products in a cost-competitive manner that is affordable. Fortunately, products such as fuel cells, thin- and mid-film PVs, batteries, electrochromic and piezoelectric films, water separation membranes, and other energy saving technologies readily lend themselves to manufacture using R2R approaches. However, more early-stage research is needed to solve the challenge of linking the materials (particles, polymers, solvents, additives) used in ink and slurry formulations and the coating and drying processes to the ultimate performance of the final R2R product, especially for a process that uses multiple layers of deposition to achieve the end product. To solve the problems associated with these challenges, the R2R Collaboration is executing a research program with outcomes that will ultimately link modeling, processing, metrology and defect detection tools, thereby directly relating the properties of constituent particles and processing conditions to the performance of final devices. This collaborative approach was designed to foster identification and development of materials and processes related to R2R for clean-energy materials development. Using computational and experimental capabilities by acknowledged subject matter experts within the supported National Laboratory system, this project leverages the capabilities and expertise at each of five National Laboratories to further the development of multilayer technologies that will enable high-volume, cost-competitive platforms. A typical R2R process has three steps: (1) mixing of particles and various constituents in a slurry, (2) coating of the ink/slurry mixture on a substrate, and (3) drying/curing and processing of the coating. Final performance of devices made via R2R processes is dependent on the active materials (e.g., electrochemical particles in battery or fuel cell electrodes) and the device structure that stems from the governing component interactions within the various steps. However, a fundamental understanding of the underlying mechanisms and phenomena is still lacking, which is why industrial-scale R2R process development and manufacturing is still largely empirical in nature. The FY 2019 through FY 2021 program addresses aspects of the following two targets from the AMO Multi-Year Program Plan: (1) Target 8.1 Develop technologies to reduce the cost per manufactured throughput of continuous R2R manufacturing processes. (A) Increasing throughput of R2R processes by 5 times for batteries (to 50 square feet per minute (50 ft 2 /min)) and capacitors and 10 times for printed electronics and the manufacture of other substrates and MEs used in support of these products. (B) Developing resolution capabilities to enable registration and alignment that will detect, align, and co-deposit multiple layers of coatings and print < 1-micron (1 µm) features using continuous process scalable for commercial production. (C) Developing scalable and reliable R2R processes for solution deposition of ultra-thin (<10 nm) films for active and passive materials. (D) Develop in-line multilayer coating technology on thin films with yields greater than 95%. (2) Target 8.2 Develop in-line instrumentation tools that will evaluate the quality of single and multilayer materials in-process. (A) Developing in-line QC technologies and methodologies for real-time identification of defects and expected product properties “in-use/application” during continuous processing at all size-scales with a focus on the “micro” and “nano” scale traces, lines, and devices, i.e., <1 μm at 300 ft./min for R2R processing in air and <10 nm at 20 ft./min for vacuum (B) Developing technologies to increase the measurement frequency of surface rheology without significant cost increases with a goal of a 10-nanometer in-line profilometry at a production rate of 100,000 square millimeters per minute (100,000 mm 2 /min).