Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Krypton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Chromatographic separation of radioactive noble gases from xenon

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes 85 Kr and 39 Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search exmperiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. Finally, a 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Adsorption and Transport Properties of Zeolite SAPO-34 for Krypton/Xenon Separations

Nuclear power is an economical means of providing carbon-free energy, but requires effective ways to deal with the radioactive waste products. As part of the overall process for recycling used nuclear fuel (UNF), it is necessary to develop technologies to separate the off-gases formed during the fission of uranium and plutonium in nuclear power reactors. The off-gas contains {sup 129}I (radioisotope), NO, NO{sub 2}, CO{sub 2} containing {sup 14}C (radioisotope), {sup 3}H{sub 2}O (radioactive tritium oxide), {sup 85}Kr (radioisotope), and {sup 136}Xe. Separating and capturing each gas is essential to reduce the volume of radioactive waste for storage. Currently there exist economical technologies to separate {sup 129}I and {sup 14}CO{sub 2}. However, Kr and Xe separation is challenging because they are chemically inert and physically very similar. The Kr/Xe mixture is approximately 10/90 by volume and hence the separation of Kr would reduce the volume of radioactive {sup 85}Kr waste by a factor of 10. One way of separating them is by cryogenic distillation wherein they are condensed out as pure streams at very low temperature (Kr boiling point: -153 deg. C, Xe: -108 deg. C). Cryogenic distillation has intensive power requirements and a large system volume, resulting in high capital, operating, and disposal costs. Membrane-based separation using radiation-stable materials such as nanoporous zeolites is an attractive alternative, if membranes with sufficient Kr flux and selectivity can be fabricated. An ideal membrane process would permeate a stream of pure Kr for storage and also produce a retentate of pure Xe which has commercial value (> $8/g at 99+% purity from Airgas{sup R}). Zeolites are nanoporous crystalline aluminosilicate materials with pores that are capable of separating molecules by shape and size. SAPO-34 is a silicoaluminophosphate zeolite with pore size of 0.38 nm. The SAPO-34 is a molecular sieve composed of 3D networks with CHA frame structure containing uniform micropores. Since this pore size is intermediate between the kinetic diameters of krypton (0.36 nm) and xenon (0.396 nm), it was hypothesized that SAPO-34 membranes can separate krypton and xenon by diffusivity differences. Previously we fabricated SAPO-34 membranes and showed that they are capable of separating Kr from Xe. Here we describe a more detailed study of the fundamental adsorption and transport properties of SAPO34. In particular, the permeabilities of Kr and Xe in SAPO-34 are dependent on both their adsorption and diffusion characteristics in the nanoporous zeolite. Typically, nanoporous materials show stronger adsorption of Xe than Kr (due to stronger van der Waals forces) but faster diffusion of Kr (due to smaller kinetic diameter). Therefore the overall membrane selectivity towards Kr will be determined by competition between these two effects. A main objective of this study is to quantify and understand adsorption, diffusion, and permeation in detail and thereby obtain: (1) fundamental parameters useful for design calculations of a Kr/Xe separation membrane process, and (2) an experimental and modeling framework that can provide guidance on the expected limits of performance of SAPO-34 and other zeolite materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a new flat stationary evacuated CPC-collector for process heat applications

For the economical supply of solar process heat at temperatures between 120 and 150 C a new non-tracking, flat, low-concentrating collector has been developed. The new collector is an edge ray collector with a concentration of 1.8 and inert gas filling, existing of parallel mounted absorber-reflector units, aligned in east-west direction. The basic concept is the integration of an absorber tube and reflectors inside a low pressure enclosure. Asymmetrical reflectors below the headers with a concentration of 0.6X provide extra radiation and prevent longitudinal radiation losses. To suppress heat losses due to gas-convection inside, air or inert gas like krypton at a pressure below 10 mbar is used. A prototype, with an aperture area of 2.0 m{sup 2}, was tested in Munich and showed efficiencies of about 50% for krypton at 0.01 bar at a temperature of 150 C with a radiation of 1000 W/m{sup 2} (900 W/m{sup 2} direct, ambient temperature 20 C). (author)

14 SOLAR ENERGY↗

The role of carrier gases in the production of metastable argon atoms in an RF discharge.

We investigate the role of carrier gases in the production of metastable argon atoms in a rf-driven discharge. The effects of different carrier gases (krypton, xenon, neon, and helium), carrier gas pressures, and rf discharge powers are examined. A xenon carrier gas provides the greatest metastable population of argon, yielding an optimal fractional metastable population of argon (Ar*/Ar) of 2 x 10{sup -4} at 0.2 mTorr of xenon gas. The optimal krypton configuration yields 60% of the xenon-supported population at 1.5 times higher pressure. Neon and helium perform considerably worse probably due to their higher ionization potentials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion energy distribution near a plasma meniscus for multielement focused ion beams

The axial ion energy spread near a plasma meniscus for multielement focused ion beams is investigated experimentally in atomic and molecular gaseous plasmas of krypton, argon, and hydrogen by tailoring the magnetic field in the region. In the case of magnetic end plugging, the ion energy spread reduces by approx50% near the meniscus as compared to the bulk plasma, thereby facilitating beam focusing. A quadrupole filter can be used to control the mean energy of the ions. Comparison with standard Maxwellian and Druyvesteyn distributions with the same mean energy indicates that the ion energy distribution in the meniscus is deficient in the population of low and high energy tail ions, resulting in a Gaussian-like profile with a spread of approx4 and approx5 eV for krypton and argon ions, respectively. By carefully tuning the wave power, plasma collisionality, and the magnetic field in the meniscus, the spread can be made lower than that of liquid metal ion sources, for extracting focused ion beams of other elements with adequate current density, for research and applications in nanosystems

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of metastable atoms in the propagation of atmospheric pressure dielectric barrier discharge jets

In the experiment of plasma jets generated in a tube dielectric barrier discharge configuration, three distinguishable modes, namely, laminar, transition, and turbulent jet modes, have been identified. Flows of helium, neon, and argon gases shared the hydrodynamic law when their plasma jets spraying into ambient air of atmospheric pressure and room temperature. Aiming to reveal the basic processes, we propose that plasma jet length is mainly determined by reactions involving metastable atoms. These processes are responsible for the variation in plasma jet length versus gas flow rate and working gas species. To investigate this proposal in detail, we have obtained three significant experimental results, i.e., (1) the plasma jet lengths of helium, neon, and argon are different; (2) the plasma jet length of krypton slightly changes with gas flow rate, with three modes indistinguishable; and (3) there are large differences between optical emission spectra of helium, neon, argon, and krypton flow gases. These observations are in good agreement with our proposal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing the operation of a high resolution vertical Johann spectrometer using a high energy fluorescer x-ray source

This paper describes the operation and testing for a vertical Johann spectrometer (VJS) operating in the 13 keV range. The spectrometer is designed to use thin curved mica crystals or thick germanium crystals. The VJS must have a resolution of E/{Delta}E=3000 or better to measure the Doppler broadening of highly ionized krypton and operate at a small x-ray angle in order to be used as a diagnostic in a laser plasma target chamber. The VJS was aligned, tested, and optimized using a fluorescer type high energy x-ray (HEX) source located at National Security Technologies (NSTec), LLC, in Livermore, CA. The HEX uses a 160 kV x-ray tube to excite fluorescence from various targets. Both rubidium and bismuth fluorescers were used for this effort. This presentation describes the NSTec HEX system and the methods used to optimize and characterize the VJS performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular Dynamics Simulation of Binary Fluid in a Nanochannel

This paper presents the results from a molecular dynamics simulation of binary fluid (mixture of argon and krypton) in the nanochannel flow. The computational software LAMMPS is used for carrying out the molecular dynamics simulations. Binary fluids of argon and krypton with varying concentration of atom species were taken for two densities 0.65 and 0.45. The fluid flow takes place between two parallel plates and is bounded by horizontal walls in one direction and periodic boundary conditions are imposed in the other two directions. To drive the flow, a constant force is applied in one direction. Each fluid atom interacts with other fluid atoms and wall atoms through Week-Chandler-Anderson (WCA) potential. The velocity profile has been looked at for three nanochannel widths i.e for 12{sigma}, 14{sigma} and 16{sigma} and also for the different concentration of two species. The velocity profile of the binary fluid predicted by the simulations agrees with the quadratic shape of the analytical solution of a Poiseuille flow in continuum theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Excitation and emission spectra of rubidium in rare-gas thin-films

To understand the optical properties of atoms in solid state matrices, the absorption, excitation, and emission spectra of rubidium doped thin-films of argon, krypton, and xenon were investigated in detail. A two-dimensional spectral analysis extends earlier reports on the excitation and emission properties of rubidium in rare-gas hosts. We found that the doped crystals of krypton and xenon exhibit a simple absorption-emission relation, whereas rubidium in argon showed more complicated spectral structures. Our sample preparation employed in the present work yielded different results for the Ar crystal, but our peak positions were consistent with the prediction based on the linear extrapolation of Xe and Kr data. We also observed a bleaching behavior in rubidium excitation spectra, which suggests a population transfer from one to another spectral feature due to hole-burning. The observed optical response implies that rubidium in rare-gas thin-films is detectable with extremely high sensitivity, possibly down to a single atom level, in low concentration samples.

36 MATERIALS SCIENCE↗

Kr II laser-induced fluorescence for measuring plasma acceleration

We present the application of laser-induced fluorescence of singly ionized krypton as a diagnostic technique for quantifying the electrostatic acceleration within the discharge of a laboratory cross-field plasma accelerator also known as a Hall effect thruster, which has heritage as spacecraft propulsion. The 728.98 nm Kr II transition from the metastable 5d{sup 4}D{sub 7/2} to the 5p{sup 4}P{sub 5/2}{sup Ring-Operator} state was used for the measurement of laser-induced fluorescence within the plasma discharge. From these measurements, it is possible to measure velocity as krypton ions are accelerated from near rest to approximately 21 km/s (190 eV). Ion temperature and the ion velocity distributions may also be extracted from the fluorescence data since available hyperfine splitting data allow for the Kr II 5d{sup 4}D{sub 7/2}-5p{sup 4}P{sub 5/2}{sup Ring-Operator} transition lineshape to be modeled. From the analysis, the fluorescence lineshape appears to be a reasonable estimate for the relatively broad ion velocity distributions. However, due to an apparent overlap of the ion creation and acceleration regions within the discharge, the distributed velocity distributions increase ion temperature determination uncertainty significantly. Using the most probable ion velocity as a representative, or characteristic, measure of the ion acceleration, overall propellant energy deposition, and effective electric fields may be calculated. With this diagnostic technique, it is possible to nonintrusively characterize the ion acceleration both within the discharge and in the plume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved association in a classical density functional theory for water

We present a modification to our recently published statistical associating fluid theory-based classical density functional theory for water. We have recently developed and tested a functional for the averaged radial distribution function at contact of the hard-sphere fluid that is dramatically more accurate at interfaces than earlier approximations. We now incorporate this improved functional into the association term of our free energy functional for water, improving its description of hydrogen bonding. We examine the effect of this improvement by studying two hard solutes (a hard hydrophobic rod and a hard sphere) and a Lennard-Jones approximation of a krypton atom solute. The improved functional leads to a moderate change in the density profile and a large decrease in the number of hydrogen bonds broken in the vicinity of the hard solutes. We find an improvement of the partial radial distribution for a krypton atom in water when compared with experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two photon absorption laser induced fluorescence measurements of neutral density in a helicon plasma

We have developed a new diagnostic based on two-photon absorption laser induced fluorescence (TALIF). We use a high intensity (5 MW/cm{sup 2}), narrow bandwidth (0.1 cm{sup −1}) laser to probe the ground state of neutral hydrogen, deuterium and krypton with spatial resolution better than 0.2 cm, a time resolution of 10 ns, and a measurement cadence of 20 Hz. Here, we describe proof-of-principle measurements in a helicon plasma source that demonstrate the TALIF diagnostic is capable of measuring neutral densities spanning four orders of magnitude; comparable to the edge neutral gradients predicted in the DIII-D tokamak pedestal. The measurements are performed in hydrogen and deuterium plasmas and absolute calibration is accomplished through TALIF measurements in neutral krypton. The optical configuration employed is confocal, i.e., both light injection and collection are accomplished with a single lens through a single optical port in the vacuum vessel. The wavelength resolution of the diagnostic is sufficient to separate hydrogen and deuterium spectra and we present measurements from mixed hydrogen and deuterium plasmas that demonstrate isotopic abundance measurements are feasible. Time resolved measurements also allow us to explore the evolution of the neutral hydrogen density and temperature and effects of wall recycling. We find that the atomic neutral density grows rapidly at the initiation of the discharge, reaching the steady-state value within 1 ms. Additionally, we find that neutral hydrogen atoms are born with 0.08 eV temperatures, not 2 eV as is typically assumed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ingot niobium as candidate electrode material for Jefferson Lab 200 kV inverted electron photogun

This contribution describes the field emission characterization of niobium electrodes using a DC high voltage field emission test apparatus. A total of six electrodes were evaluated: two large-grain, two single-crystal, and two fine-grain that were chemically polished using a buffered-chemical acid solution. Field emission from niobium electrodes could be significantly reduced and sometimes completely eliminated, by introducing krypton gas into the vacuum chamber while the electrode is biased at high voltage. Of all the electrodes tested, a large-grain niobium electrode performed the best, exhibiting no measurable field emission (<10 pA) at 225 kV with 20 mm cathode/anode gap, corresponding to a field strength of 18.7 MV/m. Motivated by these results, an inverted electron photogun operated at Jefferson Lab injector test facility was equipped with a large-grain niobium cathode electrode and it has been successfully conditioned to 225 kV without field emission. This photogun was used to study strained superlattice GaAs and K{sub 2}CsSb photocathodes at high beam currents.

43 PARTICLE ACCELERATORS↗

THE DUAL ORIGIN OF THE NITROGEN DEFICIENCY IN COMETS: SELECTIVE VOLATILE TRAPPING IN THE NEBULA AND POSTACCRETION RADIOGENIC HEATING

We propose a scenario that explains the apparent nitrogen deficiency in comets in a way that is consistent with the fact that the surfaces of Pluto and Triton are dominated by nitrogen-rich ice. We use a statistical thermodynamic model to investigate the composition of the successive multiple guest clathrates that may have formed during the cooling of the primordial nebula from the most abundant volatiles present in the gas phase. These clathrates agglomerated with the other ices (pure condensates or stoichiometric hydrates) and formed the building blocks of comets. We report that molecular nitrogen is a poor clathrate former, when we consider a plausible gas-phase composition of the primordial nebula. This implies that its trapping into cometesimals requires a low disk temperature ({approx}20 K) in order to allow the formation of its pure condensate. We find that it is possible to explain the lack of molecular nitrogen in comets as a consequence of their postformation internal heating engendered by the decay of short-lived radiogenic nuclides. This scenario is found to be consistent with the presence of nitrogen-rich ice covers on Pluto and Triton. Our model predicts that comets should present xenon-to-water and krypton-to-water ratios close to solar xenon-to-oxygen and krypton-to-oxygen ratios, respectively. In contrast, the argon-to-water ratio is predicted to be depleted by a factor of {approx}300 in comets compared to solar argon-to-oxygen, as a consequence of poor trapping efficiency and radiogenic heating.

74 ATOMIC AND MOLECULAR PHYSICS↗

Coupling between positronium formation and elastic positron-scattering channels in the rare gases

Measurements of elastic-scattering cross sections are presented for positron collisions with helium, neon, argon, krypton, and xenon around the threshold energy for positronium (Ps) formation. The elastic cross section falls slowly with increasing energy above the Ps formation threshold in helium and neon, whereas in argon, krypton, and xenon it exhibits an increase, which appears both more prominent and more sustained as the atomic number of the gas increases. It is proposed that this coupling is a result of an intermediate virtual Ps state that enhances branching into the (atom plus positron) final state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Stark broadening of Kr UV spectral lines

This work reports new data for the Stark parameters of doubly ionized krypton spectral lines. Stark widths and shifts of Kr iii lines belonging to the UV region (245-300 nm) have been measured. A low-pressure pulsed arc, containing a mixture of 8% krypton and 92% helium, was used as a plasma source. Measured electron densities and electron temperatures were in the range (0.7-2.0)x10{sup 23} m{sup -3} and 16 000-20 000 K, respectively. Experimentally obtained data were compared to theoretical results calculated using simplified modified semiempirical formulas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Initial Evaluation of CaSDB MOF Xe and Kr Capacities

Idaho National Laboratory (INL) and Pacific Northwest National Laboratory (PNNL) have been conducting parallel research, as part of the off-Gas Sigma Team, producing and testing sorbents for the selective capture of xenon and krypton from surrogate nuclear fuel reprocessing off-gas streams. Sorbents promising on a laboratory scale are tested further at INL in a system designed to emulate anticipated plant process conditions. This report summarizes INL’s initial testing of CaSDB MOF developed and produced at PNNL. Previous testing of the same base CaSDB MOF material, conducted at INL in 2016, indicated good saturation capacity for xenon, but a low xenon capacity at initial breakthrough. Additionally, the material displayed a propensity to break down into fine powder during use and handling. The current test series looks at the same base material, but with refinements to production and activation techniques. A series of ambient temperature tests were conducted to determine capacities of CaSDB MOF for krypton and xenon at initial breakthrough as well as at saturation. Adsorption tests were run in triplicate at superficial velocities of 21 and 53 cm/min, along with a single test at 373 cm/min. Saturation capacity across all tests was 30 mmol/kg +/- 2, with capacity at initial breakthrough of 8 mmol/kg +/- 1. It should be noted that while the usable portion of the material has a much tighter size distribution than that previously tested, propensity to physically break down into very fine powder with use and handling continues to be problematic. An improved engineered form is recommended prior to further testing

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗