Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “June 2010”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Efficacy and Safety of a Novel Vascular Closure Device (Glubran 2 Seal) After Diagnostic and Interventional Angiography in Patients with Peripheral Arterial Occlusive Disease

To prospectively evaluate safety and efficacy of a novel vascular closure device (Glubran 2 Seal) after peripheral angiography in patients with peripheral arterial occlusive disease (PAOD). From December 2010 to June 2011, all consecutive patients with PAOD undergoing peripheral angiography were prospectively enrolled onto the study after percutaneous antegrade or retrograde puncture of the common femoral artery. After angiography, the Glubran 2 Seal device was used to achieve hemostasis. The following data were registered: technical success and manual compression duration, patients' discomfort (scale 0-5), operators' technical difficulty (scale 0-5), and vascular complications. The site of hemostasis was evaluated by clinical inspection and color-coded Duplex ultrasound performed 1 day and 1 month after the procedure. One hundred seventy-eight patients were enrolled (112 male, mean age 70.8 years) with a total of 206 puncture sites, including 104 (50.5 %) antegrade accesses. The device was successful in 198(96.1 %) of 206 procedures, with 8 cases of manual compression lasting longer than 5 min (maximum 20 min). No major vascular complications were observed, resulting in 100 % procedural success. Minor complications occurred in seven procedures (3.4 %), including two cases of pseudoaneurysms, successfully treated by ultrasound-guided glue injection. The mean {+-} standard deviation score for patients' discomfort was 0.9 {+-} 0.7, whereas the mean score for operators' difficulty was 1.2 {+-} 0.9. In patients with PAOD, the Glubran 2 Seal represents a simple, painless, and efficient vascular closure device, able to achieve hemostasis both in antegrade and retrograde accesses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recanalization and Mortality Rates of Thrombectomy With Stent-Retrievers in Octogenarian Patients with Acute Ischemic Stroke

BackgroundOur objective was to evaluate the effect of treatment with stent-retrievers in octogenarians suffering an acute ischemic stroke.MethodsA total of 150 consecutive patients with acute stroke who were treated with stent-retrievers between April 2010 and June 2012 were retrospectively reviewed. Patients were divided into those <80 years old (n = 116) and those ≥80 (n = 34). Baseline characteristics, procedure data, and endpoints (postprocedural NIHSS, death, and mRS at 3 months) were compared.ResultsHigh blood pressure, atrial fibrillation, and anticoagulation were more frequent in octogenarians (p = 0.01, 0.003, and 0.04 respectively). There were no differences between both groups regarding previous intravenous thrombolysis (32.4 vs. 48.3 %, p = 0.1), preprocedural NIHSS (18.1 vs. 16.8, p = 0.3), procedure time (74.5 (40–114) min vs. 63 (38–92) min, p = 0.2), revascularization time (380.5 (298–526.3) min vs. 350 (296.3–452.8), p = 0.3), TICI ≥ 2B (88.2 vs. 93.9 %, p = 0.1), and symptomatic haemorrhage (5.9 vs. 2.6 %, p = 0.3). Discharge NIHSS was higher in octogenarians (9.7 vs. 6.5, p = 0.03). Death and 3-month mRS ≥3 were more frequent in octogenarians (35.3 vs. 17.2 %, p = 0.02 and 73.5 vs. 37.1 %, p = 0.02). ICA-involvement and prolonged revascularization involved higher mortality (66.7 vs. 27.6 %, p = 0.03) and worse mRS (50 vs. 24.4 %, p = 0.06) in octogenarians.ConclusionsIn our series, treatment with stent-retrievers in octogenarians with acute ischemic stroke achieved good rates of recanalization but with a high mortality rate. ICA involvement and revascularization times beyond 6 hours associated to a worse prognosis. These data might be of value in the design of prospective studies evaluating the clinical efficacy of the endovascular treatments in octogenarians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transhepatic Biliary Metal Stent for Malignant Hilar Obstruction: Results and Predictive Factors for Efficacy in 159 Patients from a Single Center

AimTo investigate and compare the efficacy and safety of percutaneous transhepatic biliary stenting (PTBS) using a one- or two-stage procedure and determine the predictive factors for the efficacious treatment of malignant hilar obstruction (MHO).Methods159 consecutive patients with MHO who underwent PTBS were enrolled between January 2010 and June 2013. Patients were classified into one- or two-stage groups. Independent predictors of therapeutic success were evaluated using a logistic regression model.Results108 patients were treated with one-stage PTBS and 51 patients were treated with two-stage PTBS. The stents were technically successful in all patients. Successful drainage was achieved in 114 patients (71.4 %). A total of 42 early major complications were observed. Re-interventions were attempted in 23 patients during follow-up. The cumulative primary patency rates at 3, 6, and 12 months were 88, 71, and 48 %, respectively. Stent placement using a one- or two-stage procedure did not significantly affect therapeutic success, early major complications, median stent patency, or survival. A stent placed across the duodenal papilla was an independent predictor of therapeutic success (odds ratio = 0.262, 95 % confidence interval [0.107–0.642]). Patients with stents across papilla had a lower rate of cholangitis compared with patients who had a stent above papilla (7.1 vs. 20.3 %, respectively, p = 0.03).ConclusionsThe majority of patients with MHO who underwent one-stage PTBS showed similar efficacy and safety outcomes compared with those who underwent two-stage PTBS. Stent placement across the duodenal papilla was associated with a higher therapeutic success rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual Guidance of Percutaneous Transthoracic Needle Biopsy with C-Arm Cone-Beam CT: Diagnostic Accuracy, Risk Factors and Effective Radiation Dose

Purpose: C-arm cone-beam computed tomography-guided transthoracic lung core needle biopsy (CBCT-CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. The purpose of our study was to evaluate the diagnostic performance, complication rates and effective radiation dose of CBCT-CNB with virtual guidance. Materials and Methods: We retrospectively collected data regarding 375 CBCT-CNBs performed with virtual guidance (XperGuide—Philips Healthcare, Best, The Netherlands) from January 2010 to June 2015 on 355 patients (mean age, 68.1 years ± 11.8; age range, 31–88 years). Patients were divided into groups and compared based on the diagnostic failure and lesion size (15 mm cutoff). Diagnostic performance, complication rate and effective radiation dose were investigated. Variables influencing diagnostic performance and complications were assessed using Student’s T test and Pearson’s χ{sup 2} test. Results: The sensitivity, specificity, positive and negative predictive value and accuracy for patients subjected to CNBs were 96.8%, 100%, 100%, 100% and 97.2%, respectively. Considering risk factors for pneumothorax, no significant differences were found regarding patient and lesion characteristics. Perilesional hemorrhage occurred more frequently in older patients (p = 0.046) and in smaller lesions (p = 0.001). Hemoptysis was significantly more frequent in patients with perilesional hemorrhage (p = 0.01). Mean effective radiation dose in CBCT-CNB was 7.12 ± 8.78 mSv. Conclusions: CBCT-CNB combined with virtual guidance is a reliable and accurate technique that allows exact localization of pulmonary lesions, effective preprocedural planning and real-time fluoroscopy altogether.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delayed Radiation-Induced Vasculitic Leukoencephalopathy

Purpose: Recently, single-fraction, high-dosed focused radiation therapy such as that administered by Gamma Knife radiosurgery has been used increasingly for the treatment of metastatic brain cancer. Radiation therapy to the brain can cause delayed leukoencephalopathy, which carries its own significant morbidity and mortality. While radiosurgery-induced leukoencephalopathy is known to be clinically different from that following fractionated radiation, pathological differences are not well characterized. In this study, we aimed to integrate novel radiographic and histopathologic observations to gain a conceptual understanding of radiosurgery-induced leukoencephalopathy. Methods and Materials: We examined resected tissues of 10 patients treated at Yale New Haven Hospital between January 1, 2009, and June 30, 2010, for brain metastases that had been previously treated with Gamma Knife radiosurgery, who subsequently required surgical management of a symptomatic regrowing lesion. None of the patients showed pathological evidence of tumor recurrence. Clinical and magnetic resonance imaging data for each of the 10 patients were then studied retrospectively. Results: We provide evidence to show that radiosurgery-induced leukoencephalopathy may present as an advancing process that extends beyond the original high-dose radiation field. Neuropathologic examination of the resected tissue revealed traditionally known leukoencephalopathic changes including demyelination, coagulation necrosis, and vascular sclerosis. Unexpectedly, small and medium-sized vessels revealed transmural T-cell infiltration indicative of active vasculitis. Conclusions: We propose that the presence of a vasculitic component in association with radiation-induced leukoencephalopathy may facilitate the progressive nature of the condition. It may also explain the resemblance of delayed leukoencephalopathy with recurring tumor on virtually all imaging modalities used for posttreatment follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plaque Brachytherapy for Uveal Melanoma: A Vision Prognostication Model

Purpose: To generate a vision prognostication model after plaque brachytherapy for uveal melanoma. Methods and Materials: All patients with primary single ciliary body or choroidal melanoma treated with iodine-125 or ruthenium-106 plaque brachytherapy between January 1, 2005, and June 30, 2010, were included. The primary endpoint was loss of visual acuity. Only patients with initial visual acuity better than or equal to 20/50 were used to evaluate visual acuity worse than 20/50 at the end of the study, and only patients with initial visual acuity better than or equal to 20/200 were used to evaluate visual acuity worse than 20/200 at the end of the study. Factors analyzed were sex, age, cataracts, diabetes, tumor size (basal dimension and apical height), tumor location, and radiation dose to the tumor apex, fovea, and optic disc. Univariate and multivariable Cox proportional hazards were used to determine the influence of baseline patient factors on vision loss. Kaplan-Meier curves (log rank analysis) were used to estimate freedom from vision loss. Results: Of 189 patients, 92% (174) were alive as of February 1, 2011. At presentation, visual acuity was better than or equal to 20/50 and better than or equal to 20/200 in 108 and 173 patients, respectively. Of these patients, 44.4% (48) had post-treatment visual acuity of worse than 20/50 and 25.4% (44) had post-treatment visual acuity worse than 20/200. By multivariable analysis, increased age (hazard ratio [HR] of 1.01 [1.00-1.03], P=.05), increase in tumor height (HR of 1.35 [1.22-1.48], P<.001), and a greater total dose to the fovea (HR of 1.01 [1.00-1.01], P<.001) were predictive of vision loss. This information was used to develop a nomogram predictive of vision loss. Conclusions: By providing a means to predict vision loss at 3 years after treatment, our vision prognostication model can be an important tool for patient selection and treatment counseling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Massive Gulf leak ushers in age of tough oil

A recent public opinion poll released on June 24, 2010, concluded that 63 percent of those surveyed support the idea that reducing emissions and increasing alternative energy are worth pursuing even if that means increased costs. The Energy Information Administration's latest Annual Energy Outlook shows that the current financial crisis has reduced U.S. oil imports from their all time peak of 60 percent and projects a gradually declining percentage through 2035 under the reference case, and even lower if oil prices remain high -- reaching $210 per barrel by 2035 in 2008 dollars.

02 PETROLEUM↗

Movement of Lake-Origin Burbot Reared in a Hatchery Environment and Released into a Large River Drainage

Abstract Burbot Lota lota in Kootenay Lake and the Kootenay River of British Columbia, Idaho, and Montana (U.S. spelling: “Kootenai River”) are at risk of demographic extinction. We conducted a pilot study to evaluate poststocking dispersal and movement of hatchery-reared, lake-strain burbot (Moyie Lake, British Columbia) in a riverine environment to determine the potential utility of this hatchery strain for future burbot rehabilitation efforts in this system. We implanted ultrasonic tags into 30 hatchery-reared burbot (ages 2 and 3) and released them into the Goat River, a tributary to the Kootenay River, in October 2009. Dispersal over a distance of 2 km from the Goat River release site to the Kootenay River occurred within 1–9 d after release (mean = 3.1 d; n = 28 active tags). Thereafter, 14 burbot remained in the Kootenay River for the rest of the 144-d study period; nine of these fish were observed moving upstream from the Goat River confluence, and five were observed both upstream and downstream from the confluence. The other 14 burbot were observed in Kootenay Lake; of these fish, eight were detected in the lake for the duration of the study, and six were observed to move regularly between the lake and the river. Dispersal distances (distance between the upstream-most and downstream-most detections per individual) within the Kootenay River ranged from 10 to 138 km (mean = 80 km), and tagged fish were detected over a 236-km reach (from 135 km downstream to 101 km upstream of the Goat River confluence). We also observed burbot in the vicinity of known spawning locations during the February spawning season. The observed dispersal suggests that a limited number of stocking locations may be sufficient to allow burbot to access available habitats within a few months postrelease. Our observations therefore suggest that lake-origin, hatchery-reared burbot may be suitable for stocking in a riverine environment. Received June 11, 2010; accepted December 4, 2010

Neufeld, Matthew D.↗

Survival of Endangered Snake River Sockeye Salmon Smolts from Three Idaho Lakes: Relationships with Parr Size at Release, Parr Growth Rate, Smolt Size, Discharge, and Travel Time

Abstract In 1991, Snake River sockeye salmon Oncorhynchus nerka were listed as endangered. The Sawtooth Valley Project was initiated to conserve and rebuild sockeye salmon populations that historically spawned and reared in five Sawtooth Valley lakes designated as critical habitat in central Idaho. We evaluated smolt survival of sockeye salmon that were stocked as parr into Redfish, Pettit, and Alturas lakes. Smolt travel time, residuals of Salmon River discharge and smolt travel time, and specific growth rate of parr explained 58% of the variation in smolt survival in a multiple-regression model. Smolt survival was inversely related to smolt travel time, and travel time was negatively correlated with mean May discharge in the Salmon River at Salmon, Idaho. We were particularly interested in the relationships between smolt survival and parr size at release, smolt size at migration, and parr growth rate. Smolt survival from nursery lakes to Lower Granite Dam was negatively correlated with mean parr size at release and mean smolt size at emigration. Smaller parr and smolts survived better. Smolt survival to the dam was correlated with parr growth rates in the three lakes combined; the relationship was nonlinear. Smolt survival increased as specific growth rate increased up to 0.06% per day, but further increases in growth rate were associated with reductions in survival. Absolute growth rates of parr were negatively related to parr weight at release. Smaller individuals grew faster than larger individuals, apparently as a result of size-dependent metabolic demand and prey availability. The relationships between smolt survival and parr size, smolt size, and parr growth rate differed among lakes. These data suggest that successful migrants must at least maintain weight during the winter preceding migration and that the stocking of smaller parr with lower metabolic demand may be preferable to stocking larger parr when forage is limited. Received November 18, 2010; accepted June 1, 2011

Griswold, Robert G.↗

AN OPTICAL SURVEY FOR MILLIMETER-SIZED INTERSTELLAR METEOROIDS

We report high-resolution multi-station observations of meteors by the Canadian Automated Meteor Observatory recorded from 2009 June to 2010 August. Our survey has a limiting detection magnitude of +5 mag in R band, equivalent to a limiting meteoroid mass of {approx}2 Multiplication-Sign 10{sup -7} kg. The high metric trajectory accuracy (of the order of 30 m perpendicular to the solution and 200 m along track) allows us to determine velocities with average uncertainty of <1.5% in speed and {approx}0.{sup 0}4 in the radiant direction. A total of 1739 meteors had measured orbits. The data have been searched for meteors in hyperbolic orbits, which are potentially of interstellar origin. We found 22 potential hyperbolic meteors among our sample, with only two of them having a speed at least 3{sigma} above the hyperbolic limit. For our one-year survey we find no clear evidence of interstellar meteoroids at millimeter sizes in a weighted time-area product of {approx}10{sup 4} km{sup 2} hr. Backward integrations performed for these 22 potentially hyperbolic meteors to check for close encounters with planets show no considerable changes in their orbits. Detailed examination leads us to conclude that our few identified events are most likely the result of measurement error. We find an upper limit of f{sub ISP} < 2 Multiplication-Sign 10{sup -4} km{sup -2} hr{sup -1} for the flux of interstellar meteoroids at Earth with a limiting mass of m > 2 Multiplication-Sign 10{sup -7} kg.

79 ASTRONOMY AND ASTROPHYSICS↗

AKARI NEAR-INFRARED SPECTROSCOPIC SURVEY FOR CO{sub 2} IN 18 COMETS

We conducted a spectroscopic survey of cometary volatiles with the Infrared Camera on board the Japanese infrared satellite AKARI in the wavelength range from 2.5 to 5 {mu}m. In our survey, 18 comets, including both the Oort cloud comets and the Jupiter-family comets, were observed in the period from 2008 June to 2010 January, most of which were observed at least twice. The prominent emission bands in the observed spectra are the fundamental vibrational bands of water (H{sub 2}O) at 2.7 {mu}m and carbon dioxide (CO{sub 2}) at 4.3 {mu}m. The fundamental vibrational band of carbon monoxide (CO) around 4.7 {mu}m and the broad emission feature, probably related to carbon-hydrogen-bearing molecules, can also be recognized around the 3.3-3.5-{mu}m region in some of the comets. With respect to H{sub 2}O, gas production rate ratios of CO{sub 2} have been derived in 17 comets, except for the comet 29P/Schwassmann-Wachmann 1. Our data set provides the largest homogeneous database of CO{sub 2}/H{sub 2}O production rate ratios in comets obtained so far. The CO{sub 2}/H{sub 2}O production rate ratios are considered to reflect the composition of cometary ice when a comet is observed at a heliocentric distance within {approx}2.5 AU, since H{sub 2}O ice fully sublimates there. The CO{sub 2}/H{sub 2}O ratio in cometary ice spans from several to {approx}30% among the comets observed at <2.5 AU (13 out of the 17 comets). Alternatively, the ratio of CO/CO{sub 2} in the comets seems to be smaller than unity based on our observations, although we only obtain upper limits for CO in most of the comets.

79 ASTRONOMY AND ASTROPHYSICS↗

A RECOLLIMATION SHOCK 80 mas FROM THE CORE IN THE JET OF THE RADIO GALAXY 3C 120: OBSERVATIONAL EVIDENCE AND MODELING

We present Very Long Baseline Array observations of the radio galaxy 3C 120 at 5, 8, 12, and 15 GHz designed to study a peculiar stationary jet feature (hereafter C80) located {approx}80 mas from the core, which was previously shown to display a brightness temperature {approx}600 times larger than expected at such distances. The high sensitivity of the images-obtained between 2009 December and 2010 June-has revealed that C80 corresponds to the eastern flux density peak of an arc of emission (hereafter A80), downstream of which extends a large ({approx}20 mas in size) bubble-like structure that resembles an inverted bow shock. The linearly polarized emission closely follows that of the total intensity in A80, with the electric vector position angle distributed nearly perpendicular to the arc-shaped structure. Despite the stationary nature of C80/A80, superluminal components with speeds up to 3 {+-} 1 c have been detected downstream from its position, resembling the behavior observed in the HST-1 emission complex in M87. The total and polarized emission of the C80/A80 structure, its lack of motion, and brightness temperature excess are best reproduced by a model based on synchrotron emission from a conical shock with cone opening angle {eta} = 10 Degree-Sign , jet viewing angle {theta} = 16 Degree-Sign , a completely tangled upstream magnetic field, and upstream Lorentz factor {gamma}{sub u} = 8.4. The good agreement between our observations and numerical modeling leads us to conclude that the peculiar feature associated with C80/A80 corresponds to a conical recollimation shock in the jet of 3C 120 located at a de-projected distance of {approx}190 pc downstream from the nucleus.

79 ASTRONOMY AND ASTROPHYSICS↗

Commissioning dose computation models for spot scanning proton beams in water for a commercially available treatment planning system

Purpose: To present our method and experience in commissioning dose models in water for spot scanning proton therapy in a commercial treatment planning system (TPS). Methods: The input data required by the TPS included in-air transverse profiles and integral depth doses (IDDs). All input data were obtained from Monte Carlo (MC) simulations that had been validated by measurements. MC-generated IDDs were converted to units of Gy mm{sup 2}/MU using the measured IDDs at a depth of 2 cm employing the largest commercially available parallel-plate ionization chamber. The sensitive area of the chamber was insufficient to fully encompass the entire lateral dose deposited at depth by a pencil beam (spot). To correct for the detector size, correction factors as a function of proton energy were defined and determined using MC. The fluence of individual spots was initially modeled as a single Gaussian (SG) function and later as a double Gaussian (DG) function. The DG fluence model was introduced to account for the spot fluence due to contributions of large angle scattering from the devices within the scanning nozzle, especially from the spot profile monitor. To validate the DG fluence model, we compared calculations and measurements, including doses at the center of spread out Bragg peaks (SOBPs) as a function of nominal field size, range, and SOBP width, lateral dose profiles, and depth doses for different widths of SOBP. Dose models were validated extensively with patient treatment field-specific measurements. Results: We demonstrated that the DG fluence model is necessary for predicting the field size dependence of dose distributions. With this model, the calculated doses at the center of SOBPs as a function of nominal field size, range, and SOBP width, lateral dose profiles and depth doses for rectangular target volumes agreed well with respective measured values. With the DG fluence model for our scanning proton beam line, we successfully treated more than 500 patients from March 2010 through June 2012 with acceptable agreement between TPS calculated and measured dose distributions. However, the current dose model still has limitations in predicting field size dependence of doses at some intermediate depths of proton beams with high energies. Conclusions: We have commissioned a DG fluence model for clinical use. It is demonstrated that the DG fluence model is significantly more accurate than the SG fluence model. However, some deficiencies in modeling the low-dose envelope in the current dose algorithm still exist. Further improvements to the current dose algorithm are needed. The method presented here should be useful for commissioning pencil beam dose algorithms in new versions of TPS in the future.

60 APPLIED LIFE SCIENCES↗

Review of “Deepwater Horizon Release Estimate of Rate by PIV”

The Plume Calculation Team (PCT) conducted high quality work within a very short period of time, in spite of needing to use less than ideal quality videos provided by British Petroleum (BP), especially those made before the cutoff of the riser above the Blow Out Preventer (BOP) on June 3, 2010. There are at least two valid approaches for estimating the oil discharge coming out from the Deepwater Horizon broken pipeline and its riser, using BP videotapes. One method is to estimate the exit velocity directly with the use of the Particle Image Velocimetry (PIV). The second method is to use a buoyant plume analysis to determine the exit velocity. The PCT used both of these methods.

02 PETROLEUM↗

Full-Scale Testing of a Mercury Oxidation Catalyst Upstream of a Wet FGD System

This document presents and discusses results from Cooperative Agreement DE-FC26-06NT42778, 'Full-scale Testing of a Mercury Oxidation Catalyst Upstream of a Wet FGD System,' which was conducted over the time-period July 24, 2006 through June 30, 2010. The objective of the project was to demonstrate at full scale the use of solid honeycomb catalysts to promote the oxidation of elemental mercury in pulverized-coal-fired flue gas. Oxidized mercury is removed downstream in wet flue gas desulfurization (FGD) absorbers and collected with the byproducts from the FGD system. The project was co-funded by EPRI, the Lower Colorado River Authority (LCRA), who also provided the host site, Great River Energy, Johnson Matthey, Southern Company, Salt River Project (SRP), the Tennessee Valley Authority (TVA), NRG Energy, Ontario Power and Westar. URS Group was the prime contractor and also provided cofunding. The scope of this project included installing and testing a gold-based catalyst upstream of one full-scale wet FGD absorber module (about 200-MW scale) at LCRA's Fayette Power Project (FPP) Unit 3, which fires Powder River Basin coal. Installation of the catalyst involved modifying the ductwork upstream of one of three wet FGD absorbers on Unit 3, Absorber C. The FGD system uses limestone reagent, operates with forced sulfite oxidation, and normally runs with two FGD modules in service and one spare. The full-scale catalyst test was planned for 24 months to provide catalyst life data. Over the test period, data were collected on catalyst pressure drop, elemental mercury oxidation across the catalyst module, and mercury capture by the downstream wet FGD absorber. The demonstration period began on May 6, 2008 with plans for the catalyst to remain in service until May 5, 2010. However, because of continual increases in pressure drop across the catalyst and concerns that further increases would adversely affect Unit 3 operations, LCRA decided to end the demonstration early, during a planned unit outage. On October 2, 2009, Unit 3 was taken out of service for a fall outage and the catalyst upstream of Absorber C was removed. This ended the demonstration after approximately 17 months of the planned 24 months of operation. This report discusses reasons for the pressure drop increase and potential measures to mitigate such problems in any future application of this technology. Mercury oxidation and capture measurements were made on Unit 3 four times during the 17-month demonstration. Measurements were performed across the catalyst and Absorber C and 'baseline' measurements were performed across Absorber A or B, which did not have a catalyst upstream. Results are presented in the report from all four sets of measurements during the demonstration period. These results include elemental mercury oxidation across the catalyst, mercury capture across Absorber C downstream of the catalyst, baseline mercury capture across Absorber A or B, and mercury re-emissions across both absorbers in service. Also presented in the report are estimates of the average mercury control performance of the oxidation catalyst technology over the 17-month demonstration period and the resulting mercury control costs.

01 COAL, LIGNITE, AND PEAT↗

Renewable Energy Opportunities at Fort Sill, Oklahoma

This document provides an overview of renewable resource potential at Fort Sill, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. This effort focuses on grid-connected generation of electricity from renewable energy sources and on ground source heat pumps for heating and cooling buildings. The effort was funded by the U.S. Army Installation Management Command (IMCOM) as follow-on to the 2005 Department of Defense (DoD) Renewables Assessment. The site visit to Fort Sill took place on June 10, 2010.

15 GEOTHERMAL ENERGY↗

Renewable Energy Opportunities at Fort Campbell, Tennessee/Kentucky

This document provides an overview of renewable resource potential at Fort Campbell, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. This effort focuses on grid-connected generation of electricity from renewable energy sources and also on ground source heat pumps for heating and cooling buildings. The effort was funded by the U.S. Army Installation Management Command (IMCOM) as follow-on to the 2005 Department of Defense (DoD) Renewables Assessment. The site visit to Fort Campbell took place on June 10, 2010.

15 GEOTHERMAL ENERGY↗

Addendum to the East Tennessee Technology Park Site-Wide Residual Contamination Remedial Investigation Work Plan Oak Ridge, Tennessee

The East Tennessee Technology Park Site-Wide Residual Contamination Remedial Investigation Work Plan (DOE 2004) describes the planned fieldwork to support the remedial investigation (RI) for residual contamination at the East Tennessee Technology Park (ETTP) not addressed in previous Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) decisions. This Addendum describes activities that will be conducted to gather additional information in Zone 1 of the ETTP for groundwater, surface water, and sediments. This Addendum has been developed from agreements reached in meetings held on June 23, 2010, August 25, 2010, October 13, 2010, November 13, 2010, December 1, 2010, and January 13, 2011, with representatives of the U. S. Department of Energy (DOE), U. S. Environmental Protection Agency (EPA), and Tennessee Department of Environment and Conservation (TDEC). Based on historical to recent groundwater data for ETTP and the previously completed Sitewide Remedial Investigation for the ETTP (DOE 2007a), the following six areas of concern have been identified that exhibit groundwater contamination downgradient of these areas above state of Tennessee and EPA drinking water maximum contaminant levels (MCLs): (1) K-720 Fly Ash Pile, (2) K-770 Scrap Yard, (3) Duct Island, (4) K-1085 Firehouse Burn/J.A. Jones Maintenance Area, (5) Contractor's Spoil Area (CSA), and (6) Former K-1070-A Burial Ground. The paper presents a brief summary of the history of the areas, the general conceptual models for the observed groundwater contamination, and the data gaps identified.

54 ENVIRONMENTAL SCIENCES↗