Colossal switchable photocurrents in topological Janus transition metal dichalcogenides

Nonlinear optical properties, such as bulk photovoltaic effects, possess great potential in energy harvesting, photodetection, rectification, etc. To enable efficient light–current conversion, materials with strong photo-responsivity are highly desirable. In this work, we predict that monolayer Janus transition metal dichalcogenides (JTMDs) in the 1T' phase possess colossal nonlinear photoconductivity owing to their topological band mixing, strong inversion symmetry breaking, and small electronic bandgap. 1T'JTMDs have inverted bandgaps on the order of 10 meV and are exceptionally responsive to light in the terahertz (THz) range. By first-principles calculations, we reveal that 1T' JTMDs possess shift current (SC) conductivity as large as 2300 nm μA V -2 , equivalent to a photo-responsivity of 2800 mA/W. The circular current (CC) conductivity of 1T' JTMDs is as large as ~10 4 nm μA V -2 . These remarkable photo-responsivities indicate that the 1T' JTMDs can serve as efficient photodetectors in the THz range. We also find that external stimuli such as the in-plane strain and out-of-plane electric field can induce topological phase transitions in 1T' JTMDs and that the SC can abruptly flip their directions. The abrupt change of the nonlinear photocurrent can be used to characterize the topological transition and has potential applications in 2D optomechanics and nonlinear optoelectronics.

Chemistry↗

Extreme High and Low Temperature Operation of the Silicon-On-Insulator Type CHT-OPA Operational Amplifier

A new operational amplifier chip based on silicon-on-insulator technology was evaluated for potential use in extreme temperature environments. The CHT-OPA device is a low power, precision operational amplifier with rail-to-rail output swing capability, and it is rated for operation between -55 C and +225 C. A unity gain inverting circuit was constructed utilizing the CHT-OPA chip and a few passive components. The circuit was evaluated in the temperature range from -190 C to +200 C in terms of signal gain and phase shift, and supply current. The investigations were carried out to determine suitability of this device for use in space exploration missions and aeronautic applications under wide temperature incursion. Re-restart capability at extreme temperatures, i.e. power switched on while the device was soaked at extreme temperatures, was also investigated. In addition, the effects of thermal cycling under a wide temperature range on the operation of this high performance amplifier were determined. The results from this work indicate that this silicon-on-insulator amplifier chip maintained very good operation between +200 C and -190 C. The limited thermal cycling had no effect on the performance of the amplifier, and it was able to re-start at both -190 C and +200 C. In addition, no physical degradation or packaging damage was introduced due to either extreme temperature exposure or thermal cycling. The good performance demonstrated by this silicon-on-insulator operational amplifier renders it a potential candidate for use in space exploration missions or other environments under extreme temperatures. Additional and more comprehensive characterization is, however, required to establish the reliability and suitability of such devices for long term use in extreme temperature applications.

Patterson, Richard↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response: Preprint

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believes that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost benefit↗

Wind Energy Costs in Puerto Rico Through 2035

In 2019, Puerto Rico codified into law a 100% renewable electricity by 2050 target. Decision makers there need information about the costs and performance of wind energy technologies to incorporate into planning efforts for the future grid. After consulting with key technical stakeholders and accounting for unique conditions in Puerto Rico like increased hurricane risks, we customize NREL's Renewable Energy Potential model to calculate how capital expenditures, operational expenditures, net annual energy generation, and levelized cost of energy (LCOE) vary in time and space for wind energy projects around Puerto Rico. Wind turbines can add value by providing grid services through grid-forming inverters and complement solar energy generation with evening and nighttime electricity production, especially offshore. By 2035, we expect average costs of land-based and offshore wind energy in Puerto Rico to reach $\$$69/MWh (6.9 cents/kWh) and $\$$100/MWh (10 cents/kWh), respectively. While these projections do not include transmission system upgrade costs, they do suggest that low-cost, clean electricity is possible for Puerto Rico.

17 WIND ENERGY↗

Enhanced Inertial Support: Modeling Fast Frequency Response Controls for Energy Storage System Inverters

Reduction of power system inertia is a growing concern for grid operators given the transition under way from conventional fossil generators to inverter-based resources. One key concern is the rapid and severe dip in power system frequency following a large disturbance which could trigger remedial actions including operation of under frequency load shedding (UFLS) relays. A potential solution is to utilize battery energy storage systems (BESS) to provide fast frequency response(FFR) to mitigate the system frequency impact of low system inertia. In this work, we investigate different control parameters to achieve modeled FFR response from BESS in the simulated US Western Interconnection. First, a very low inertia model is developed from an existing positive sequence model of the Western Interconnection. Afterwards, we tune the BESS dynamic response parameters to eliminate any risks of reaching UFLS relay thresholds following the loss of large generators. Finally, we investigate the relative impact of having large BESS units in comparison of multiple smaller units in the same area. The results of the analyses indicate that 1 GW of transmission-connected BESS can help mitigate the frequency drop caused by large generators outages in the Western Interconnection, and significantly reduce the risk of under frequency load shedding.

power system dynamic performance, Low Inertia, Fas↗

Venus gravity - A high-resolution map

The Doppler data from the radio tracking of the Pioneer Venus Orbiter (PVO) have been used in a two-stage analysis to develop a high-resolution map of the gravitational potential of Venus, represented by a central mass and a surface mass density. The two-stage procedure invokes a Kalman filter-smoother to determine the orbit of the spacecraft, and a stabilized linear inverter to estimate the surface mass density. The resultant gravity map is highly correlated with the topographic map derived from the PVO radar altimeter data. However, the magnitudes of the gravity variations are smaller than would be expected if the topography were uncompensated, indicating that at least partial compensation has taken place.

Reasenberg, R. D.↗

Use of acoustic wave travel-time measurements to probe the near-surface layers of the Sun

The variation of solar p-mode travel times with cyclic frequency nu is shown to provide information on both the radial variation of the acoustic potential and the depth of the effective source of the oscillations. Observed travel-time data for waves with frequency lower than the acoustic cutoff frequency for the solar atmosphere (approximately equals 5.5 mHz) are inverted to yield the local acoustic cutoff frequency nu(sub c) as a function of depth in the outer convection zone and lower atmosphere of the Sun. The data for waves with nu greater than 5.5 mHz are used to show that the source of the p-mode oscillations lies approximately 100 km beneath the base of the photosphere. This depth is deeper than that determined using a standard mixing-length calculation.

Jefferies, S. M.↗

Challenges, Industry Practice, and Research Opportunities for Protection of IBR-Rich Systems

The objective of this technical report is to outline the challenges of protection design for power systems rich in inverter-based resources (IBRs), synthesize current industrial practices, review new approaches from recent literature, and explore future opportunities in protection. IBRs are experiencing widespread adoption across both transmission and distribution systems. When present in significant quantities, IBRs challenge the performance of many traditional protection functions. To address these issues, the industry has developed sophisticated protection schemes that involve advanced relaying techniques in highly engineered pilot projects. However, these schemes are expensive and time-consuming to develop, build, and test. Researchers have proposed a number of new approaches for protection in IBR-rich distribution systems. Despite their potential, these new approaches do not address some major shortcomings of industry approaches stemming from complexity, practical requirements, and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Design of Series-connected PV-powered Grid-forming Converters via Singular Perturbation

We report modular architectures that consist of several series-connected dc-ac converters have been a focal point of recent innovations in transformerless medium-voltage applications. In this paper, we consider an architecture consisting of dc-ac modules containing a quadruple active bridge dc-dc converter, which generates three floating dc links that feed grid-side dc-ac inverters. Practical implementation of such a converter module in PV systems requires a variety of controllers that collectively achieve maximum power point tracking, dc-link regulation, and ac-side power control. Design of such multi-loop systems is generally quite challenging due to the potential for destabilizing interactions among loops. Here we propose a design approach where singular perturbation theory is used to decompose the timescales at which each control loop operates and provides a systematic framework for parametric selection. Our approach also ensures system stability of multiple modules with identical controls connected in series across a grid. The paper concludes with experimental results of three 1000 W series-connected converter modules across a stiff grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extending the Near-Infrared Emission Range of Indium Phosphide Quantum Dots for Multiplexed In Vivo Imaging

This report of the reddest emitting indium phosphide quantum dots (InP QDs) to date demonstrates tunable, near-infrared (NIR) photoluminescence (PL) as well as PL multiplexing in the first optical tissue window while avoiding toxic constituents. This synthesis overcomes the InP “growth bottleneck” and extends the emission peak of InP QDs deeper into the first optical tissue window using an inverted QD heterostructure, specifically ZnSe/InP/ZnS core/shell/shell nanoparticles. The QDs exhibit InP shell thickness-dependent tunable emission with peaks ranging from 515–845 nm. The high absorptivity of InP yields effective photoexcitation of the QDs with UV, visible, and NIR wavelengths. These nanoparticles extend the range of tunable direct-bandgap emission from InP-based nanostructures, effectively overcoming a synthetic barrier that has prevented InPbased QDs from reaching their full potential as NIR imaging agents. Further, multiplexed lymph node imaging in a mouse model demonstrates the potential of the NIR-emitting InP particles for in vivo imaging.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Coaxial Direct Ink Writing of Cholesteric Liquid Crystal Elastomers in 3D Architectures

Abstract Cholesteric liquid crystal elastomers (CLCEs) hold great promise for mechanochromic applications in anti‐counterfeiting, smart textiles, and soft robotics, thanks to the structural color and elasticity. While CLCEs are printed via direct ink writing (DIW) to fabricate free‐standing films, complex 3D structures are not fabricated due to the opposing rheological properties necessary for cholesteric alignment and multilayer stacking. Here, 3D CLCE structures are realized by utilizing coaxial DIW to print a CLC ink within a silicone ink. By tailoring the ink compositions, and thus, the rheological properties, the cholesteric phase rapidly forms without an annealing step, while the silicone shell provides encapsulation and support to the CLCE core, allowing for layer‐by‐layer printing of self‐supported 3D structures. As a demonstration, free‐standing bistable thin‐shell domes are printed. Color changes due to compressive and tensile stresses can be witnessed from the top and bottom of the inverted domes, respectively. When the domes are arranged in an array and inverted, they can snap back to their base state by uniaxial stretching, thereby functioning as mechanical sensors with memory. The additive manufacturing platform enables the rapid fabrication of 3D mechanochromic sensors thereby expanding the realm of potential applications for CLCEs.

36 MATERIALS SCIENCE↗

Stratigraphy‐Induced Localization of Microseismicity During CO 2 Injection in Illinois Basin

Abstract Subsurface fluid injection stimulates complex hydromechanical interaction, necessitating the integration of geomechanical data across spatial and temporal scales to consider the sophisticated behavior. Induced seismic response is usually associated with the complex reservoir architecture and pre‐existing features that are three‐dimensional, such as local stratigraphy, fractures, faults, and other discontinuities. This study encompasses laboratory characterization of the coupled hydromechanical response of cores extracted from rock formations in Illinois Basin: reservoir ‐ Mt. Simon sandstone, basal seal ‐ Argenta sandstone, and crystalline basement ‐ Precambrian rhyolite. High‐resolution numerical modeling allows considering the three‐dimensional complexity of the Illinois Basin Decatur Project with spatial resolution comparable to one of the active seismic surveys. A detailed reconstruction of the evolving state of stress in formations lacking direct stress measurements is achieved by numerical modeling that integrated laboratory‐derived hydromechanical properties, a porosity‐permeability relationship, active seismic data, and an inverted three‐dimensional porosity distribution. It appears that the microseismic clusters, mainly observed in the crystalline basement during the injection, are linked to zones experiencing more critically stressed conditions prior to injection. These zones have a potential for reactivation during the injection and are attributed to the specific local stratigraphy of the injection site, as well as transfer of triggering perturbations during the injection.

Bondarenko, N. [University of Illinois Urbana‐Cham↗

A Scalable Transmission and Distribution Co-simulation Platform for IBR-heavy Power Systems

The integration of Inverter-Based Resources (IBRs) into power systems, including both transmission and distribution networks, poses challenges for studying grid dynamic behaviours under various operating conditions and system events. This paper addresses the urgent need to investigate the influence of IBRs on grid dynamics, and their potential to enhance power system reliability and resilience. We propose a flexible, scalable transmission and distribution co-simulation platform, using opensource tools only for assessing the impact of grid-following (GFL) and grid-forming (GFM) IBRs on dynamic stability at various renewable penetration levels (up to 100%). This platform enables researchers to explore different contingencies at transmission, distribution, or both, providing a comprehensive evaluation of grid status. A series of case studies, including both small and large T&D systems with varying GFL/GFM configurations and contingencies, have been conducted. The results not only robustly validate our co-simulation framework, but also provide invaluable insights for effective IBR management in the power grid.

grid management↗

Evaluation of Adaptive Volt-VAR to Mitigate PV Impacts [Slides]

Distributed generation (DG) sources like photovoltaic (PV) systems with advanced inverters are able to perform grid-support functions, like autonomous Volt-VAR that attempts to mitigate voltage issues by injecting or consuming reactive power. However, the Volt-VAR function operates with VAR priority, meaning real power may be curtailed to provide additional reactive power support. Since some locations on the grid may be more prone to higher voltages than others, PV systems installed at those locations may be forced to curtail more power, adversely impacting the value of that PV system. Adaptive Volt-VAR (AVV) could be implemented as an alternative, whereby the Volt-VAR reference voltage changes over time, but this functionality has not been well-explored in the literature. In this work, the potential benefits and grid impacts of AVV were investigated using yearlong quasi-static time-series (QSTS) simulations. After testing a variety of allowable AVV settings, we found that even with aggressive settings AVV resulted in <0.01% real power curtailment and significantly reduced the reactive power support required from the PV inverter compared to conventional Volt-VAR but did not provide much mitigation for extreme voltage conditions. The reactive power support provided by AVV was injected to oppose large deviations in voltage (in either direction), indicating that it could be useful for other applications like reducing voltage flicker or minimizing interactions with other voltage regulating devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Power Hardware-in-the-Loop Interfacing: Applying Modern Control For Design and Verification of High-Accuracy Interfaces

Here, we develop a novel approach to designing power hardware-in-the-loop (PHIL) simulation interfaces that maximizes simulation bandwidth and accuracy by leveraging a modern control framework that explicitly considers objectives on accuracy and can automatically synthesize an optimal controller that meets these objectives while stabilizing the closed-loop system. The method developed improves upon common approaches to PHIL interface design that typically involve multiple design steps for manual compensation and stabilization design that can result in interfaces that are stable but have suboptimal bandwidth and accuracy. The approach developed is general and can be applied to most PHIL system configurations. The modeling framework allows for the inclusion of scaling factors and hardware-under-test current injection models that are common to practical PHIL simulations and have significant impacts on stability. We also present practical methods and metrics for verifying the absolute accuracy of PHIL simulation results without relying on relative comparisons to potentially inaccurate models or previous simulation results. We demonstrate the accuracy evaluation method and show the improved performance achievable when using the optimal PHIL interface design approach in an experimental case study involving a 100-kVA battery inverter.

42 ENGINEERING↗

Security assessment and impact analysis of cyberattacks in integrated T&D power systems

In this paper, we examine the impact of cyberattacks in an integrated transmission and distribution (T&D) power grid model with distributed energy resource (DER) integration. We adopt the OCTAVE Allegro methodology to identify critical system assets, enumerate potential threats, analyze and prioritize risks for threat scenarios. Based on the analysis, attack strategies and exploitation scenarios are identified which could lead to system compromise. Specifically, we investigate the impact of data integrity attacks in inverted-based solar PV controllers, control signal blocking attacks in protective switches and breakers, and coordinated monitoring and switching time-delay attacks. Index Terms—Cyberattacks, security assessment, impact analysis, case studies, integrated power systems.

14 SOLAR ENERGY↗

Satellite observations of suprathermal electron bursts

Data from the ISIS 2 satellite are used to study the spatial distribution of the suprathermal electron bursts discovered by high-altitude sounding rockets. It is found that the bursts form an integral part of the boundary plasma sheet and are linked with the formation of discrete auroral arcs. The maximum energy of the bursts is always below the peak energy in neighboring discrete forms, and it appears that if the bursts fail to reach the minimum energy found to be necessary to sustain a discrete arc they collapse within a few seconds. It is suggested that in a pass across the auroral oval the overall envelope of the maximum energy in bursts and the peak energy in discrete auroral forms reflect the variation of the available acceleration (perhaps a parallel electric potential) across the auroral oval while the energy structure in individual forms is a function of the nonlinear processes which sustain them. This explanation appears to resolve the apparent discrepancy in scale thickness between rocket and satellite inverted V's.

Johnstone, A. D.↗

Single-state selection system for hydrogen masers

The design and operation of a single-state selection system based on the adiabatic fast-passage technique for atomic state inversion is described. The system uses a variable-pitch dc solenoid and orthogonal four-wire RF coil to create the state-changing magnetic fields, and a half-wavelength state selection magnet to remove the inverted state atoms from the hydrogen beam. The system's performance was determined by measuring maser power as a function of line Q. The system removes more than 85 percent of undesired atoms from the beam. The potential effects of improvements in the maser on its frequency stability have been calculated. The use of single-state selection combined with increased RF coupling to the cavity and increased storage bulb collimation offers the possibility of frequency stability in the 10 to the -17th regime over intervals on the order of 60,000 s.

Mattison, Edward M.↗