Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

An investigation of the optimization of parameters affecting the implementation of fourier transform spectroscopy at 20-500 micron from the C-141 airborne infrared observatory

A program for 20-500 micron spectroscopy from the NASA flying C141 infrared observatory is being carried out with a Michelson interferometer. The parameters affecting the performance of the instrument are studied and an optimal configuration for high performance on the C-141 aircraft is recommended. As each parameter is discussed the relative merits of the two modes of mirror motion (rapid scan or step and integrate) are presented.

Thompson, R. I.↗

The S-054 X-ray telescope experiment on Skylab

A description of the S-054 X-ray telescope on Skylab is presented with a discussion of the experimental objectives, observing program, data reduction and analysis. Some results from the Skylab mission are given. The telescope photographically records high-resolution images of the solar corona in several broadband regions of the soft X-ray spectrum. It includes an objective grating used to study the line spectrum. The spatial resolution, sensitivity, dynamic range and time resolution of the instrument were chosen to survey a wide variety of solar phenomena. It embodies improvements in design, fabrication, and calibration techniques which were developed over a ten-year period. The observing program was devised to optimize the use of the instrument and to provide studies on a wide range of time scales. The data analysis program includes morphological studies and quantitative analysis using digitized images. A small sample of the data obtained in the mission is presented to demonstrate the type of information that is available and the kinds of results that can be obtained from it.

Vaiana, G. S.↗

Optimal Design of Calibration Signals in Space Borne Gravitational Wave Detectors

Future space borne gravitational wave detectors will require a precise definition of calibration signals to ensure the achievement of their design sensitivity. The careful design of the test signals plays a key role in the correct understanding and characterization of these instruments. In that sense, methods achieving optimal experiment designs must be considered as complementary to the parameter estimation methods being used to determine the parameters describing the system. The relevance of experiment design is particularly significant for the LISA Pathfinder mission, which will spend most of its operation time performing experiments to characterize key technologies for future space borne gravitational wave observatories. Here we propose a framework to derive the optimal signals in terms of minimum parameter uncertainty to be injected to these instruments during its calibration phase. We compare our results with an alternative numerical algorithm which achieves an optimal input signal by iteratively improving an initial guess. We show agreement of both approaches when applied to the LISA Pathfinder case.

LISA Path_nder mission↗

An automated system to define the optimal operating settings of cryogenic calorimeters

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and stability. In this paper we present a set of automatic measurements and analysis procedures for the characterization and optimization of the working configuration of the NTD thermistors. The presented procedures were developed for CUORE, an array of 988 cryogenic macro-calorimeters instrumented with NTD thermistors that has been taking data since 2017. These procedures made it possible to characterize a large number of detectors in a reliable way. They are suitable enough to be used also in other large arrays of cryogenic detectors, such as CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cellular glass substrate solar concentrator

The design of a second generation point focusing solar concentration is discussed. The design is based on reflective gores fabricated of thin glass mirror bonded continuously to a contoured substrate of cellular glass. The concentrator aperture and structural stiffness was optimized for minimum concentrator cost given the performance requirement of delivering 56 kWth to a 22 cm diameter receiver aperture with a direct normal insolation of 845 watts sq m and an operating wind of 50 kmph. The reflective panel, support structure, drives, foundation and instrumentation and control subsystem designs, optimized for minimum cost, are summarized. The use of cellular glass as a reflective panel substrate material is shown to offer significant weight and cost advantages compared to existing technology materials.

Bedard, R.↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

How Well Satellite Remote Sensing Can Inform Surface Level Ozone Production Sensitivity to Precursor Trace Gas Emissions?

Surface-level ozone (O3) pollution mitigation strategies rely on a clear understanding of the atmospheric chemical processes involving O3, NOx (nitric oxide (NO) + nitrogen dioxide (NO2)) and volatile organic compounds (VOCs). A robust spatiotemporal classification of O3 photochemical regimes with relative chemical sensitivity of local O3 formation to emission reductions of NOx (NOx-limited regime) versus VOCs (radical-limited regime) is required to design anthropogenic emission reduction policies in order to improve surface air quality. Numerous studies found that the ratio of satellite-retrieved Vertical Column Densities (VCDs) of formaldehyde (HCHO) to NO2 can diagnose O3 production sensitivity. However, uncertainty still remains about the accuracy of such estimates using satellite-based retrievals. This study conducts an investigation to identify how well satellite data can inform surface-level O3 sensitivity by validating satellite-based estimates against aircraft-based retrievals taken during the Long Island Sound Tropospheric Ozone Study (LISTOS-2018) and Ozone Water-Land Environmental Transition Study (OWLETS-2) field campaigns. For this study, we use HCHO and NO2 retrievals from the Ozone Monitoring Instrument (OMI) onboard the Aura satellite, and high spatiotemporal resolution TROPOspheric Monitoring Instrument (TROPOMI) onboard the Sentinel-5 Precursor (S5P) satellite. The Community Multiscale Air Quality (CMAQ) modelling system is used to provide trace gas vertical profiles to recalculate air mass factor for deriving consistent satellite-based VCDs. To demonstrate the ability of satellites to diagnose O3 production regimes, we validate satellite-derived O3 sensitivity regimes, along with the OMI and TROPOMI products applied, using HCHO and NO2 retrievals from the aircraft-based instruments: Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) spectrometer and Geostationary Coastal and Air Pollution Events Airborne Simulator (GCAS) instruments deployed during the LISTOS-2018 and OWLETS-2 campaigns. The results of this work will advance our fundamental knowledge of the spatiotemporal evolution of the complex O3-NOx-VOC chemistry, and will advance our understanding about the quality of remote-sensing, suborbital, and satellite data for accurately observing surface-level O3 production sensitivity.

Satellite↗

Contributions of the SSBUV Experiment to Long-Term Ozone Monitoring

The SSBUV experiment flew eight Space Shuttle missions from October 1989 to January 1996 in conducted eight missions between October 1989 and support of the US long-term ozone monitoring program. Contributions of the SSBUV experiment are reviewed in this paper. SSBUV data are being used to provide and validate the absolute and long-term calibrations of multiple satellite-based ozone monitoring instruments. SSBUV observed a significant decrease in Northern hemisphere total ozone from the winter of 1992 to the following winter, and SSBUV data were combined with Nimbus-7 data to assess long-term ozone changes during the 1980's. SSBUV solar irradiance measurements are being used to determine the absolute solar spectral irradiance in the middle UV, validate solar data from two UARS instruments, and independently measure long-term solar change at wavelengths important for ozone photochemistry. SSBUV data where also used to study the effects of surface reflectivity and rotational Raman scattering on the ozone retrievals, determine the NO column amount and its altitude distribution, measure the UV lunar albedo, and assist in the optimization of wavelengths for new instruments.

Hilsenrath, E.↗

WFIRST CGI Integral Field Spectrograph Performance and Post-Processing in the OS6 Observing Scenario

The WFIRST coronagraph instrument (CGI) will have an integral field spectrograph (IFS) backend to disperse the entire field of view at once and obtain spatially-resolved, low-resolution spectra of the speckles and science scene. The IFS will be key to understanding the spectral nature of the speckles, obtain science spectra of planets and disks, and will be used for broadband wavefront control. In order to characterize, predict, and optimize the performance of the instrument, we present a detailed model of the IFS in the context of the new OS6 observing scenario. The simulation includes spatial, spectral, and temporal variations of the speckle field on the IFS detector plane, which allows us to explore several post-processing methods and assess what gains can be expected. The simulator includes the latest models of the detector behavior when operating in photon-counting mode.

WFIRST coronagraph instrument (CGI)↗

Towards an Optimal Estimation Retrieval of Cirrus Cloud Optical and Microphysical Properties Using Hyperspectral Shortwave Instruments and A Fast Radiative Transfer Algorithm

Cirrus cloud retrieval products (here, cloud optical depth, effective particle size, and cloud top height) are important inputs into numerical weather and climate models. Uncertainties in such retrieval products, as a matter of course, propagate downstream, impacting model calculations. Improvements in high-quality global cirrus cloud optical and microphysical data products from satellite observations are needed to understand and reduce retrieval uncertainties. Hyperspectral shortwave instruments produce high-resolution and information-dense spectra, thus offering the opportunity to reduce uncertainties in retrieval products. We are in the process of developing a retrieval that uses the very fast Principal Component Radiative Transfer Model in the solar spectral region (PCRTM-Solar) in the forward model calculations. This retrieval will use measured reflectances from the NASA Earth Surface Mineral Dust Source Investigation (EMIT) and the forthcoming Climate Absolute Radiance and Refractivity Observatory Pathfinder (CLARREO-Pathfinder) instruments. In this manuscript we present progress towards a reference retrieval employing a widely used, verified, accurate, yet computationally slower radiative transfer modeling technique. The reference retrieval, while too slow for using the complete hyperspectral measurement, will allow us to study the behavior of retrieval products and help us verify results from our in-development fast retrieval. Both retrievals will use the optimal estimation retrieval framework. In this manuscript we present results from an uncertainty analysis considering three uncertainty sources for a cirrus cloud retrieval in the form of error covariance matrices: reflectance uncertainty due to water vapor, the reflectance uncertainty due to ice crystal scattering assumptions, and the instrument measurement uncertainty. Results show that the uncertainty due to habit selection is the largest, while that due to water vapor is at most 0.6% relative to channel reflectance. As a first step, the retrieval is being designed for single layer ice clouds over open ocean water.

Cirrus cloud↗

ExoSpec Project: An Exoplanet Spectroscopy Technology Research Collaboration Based at NASA’s Goddard Space Flight Center and Ames Research Center

The exoplanet atmosphere characterization goals of future UV/Optical/Infrared flagship space missions will drive challenging design requirements for instrument wavefront controls, spatial and spectral sampling, spectral bandwidth, and detector performance. The new ExoSpec Project links four previously distinct research efforts at Goddard and Ames for enabling and enhancing the characterization of directly-imaged exoplanets. ExoSpec is comprised of three laboratory subsystem demonstrations: high-contrast integral field spectrographs, p-channel CCDs, and parabolic deformable mirrors. A fourth component, exoplanet spectral retrieval, is an iterative data simulation activity driven by the goal of optimizing the system-level instrument design for atmosphere retrieval metrics. The ExoSpec Project’s emphasis on system-level spectroscopy performance complements the objectives of other technology demonstrations supported by NASA.

Neil T Zimmerman↗

Modular droplet injector for sample conservation providing new structural insight for the conformational heterogeneity in the disease-associated NQO1 enzyme

Droplet injection strategies are a promising tool to reduce the large amount of sample consumed in serial femtosecond crystallography (SFX) measurements at X-ray free electron lasers (XFELs) with continuous injection approaches. Here, we demonstrate a new modular microfluidic droplet injector (MDI) design that was successfully applied to deliver microcrystals of the human NAD(P)H:quinone oxidoreductase 1 (NQO1) and phycocyanin. We investigated droplet generation conditions through electrical stimulation for both protein samples and implemented hardware and software components for optimized crystal injection at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Stanford Linac Coherent Light Source (LCLS). Under optimized droplet injection conditions, we demonstrate that up to 4-fold sample consumption savings can be achieved with the droplet injector. In addition, we collected a full data set with droplet injection for NQO1 protein crystals with a resolution up to 2.7 Å, leading to the first room-temperature structure of NQO1 at an XFEL. NQO1 is a flavoenzyme associated with cancer, Alzheimer's and Parkinson's disease, making it an attractive target for drug discovery. Further, our results reveal for the first time that residues Tyr128 and Phe232, which play key roles in the function of the protein, show an unexpected conformational heterogeneity at room temperature within the crystals. These results suggest that different substates exist in the conformational ensemble of NQO1 with functional and mechanistic implications for the enzyme's negative cooperativity through a conformational selection mechanism. Our study thus demonstrates that microfluidic droplet injection constitutes a robust sample-conserving injection method for SFX studies on protein crystals that are difficult to obtain in amounts necessary for continuous injection, including the large sample quantities required for time-resolved mix-and-inject studies.

59 BASIC BIOLOGICAL SCIENCES↗

Counter tube window and X-ray fluorescence analyzer study

A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.

Hertel, R.↗

The Cusp Plasma Imaging Detector (Cupid) Cubesat Observatory: Instrumentation

The Cusp Plasma Imaging Detector (CuPID) CubeSat observatory is a 6U CubeSat designed to observe solar wind charge exchange in magnetospheric cusps to test competing theories of magnetic reconnection at the Earth’s magnetopause. The CuPID is equipped with three instruments, namely, a wide field-of-view (4.6° × 4.6°) soft x-ray telescope, a micro-dosimeter suite, and an engineering magnetometer optimized for the science operation. The instrument suite has been tested and calibrated in relevant environments, demonstrating successful design. The testing and calibration of these instruments produced metrics and coefficients that will be used to create the CuPID mission’s data product.

Magnetospheric dynamics↗

Gamma Ray Source Localization for Time Projection Chamber Telescopes Using Convolutional Neural Networks

Diverse phenomena such as positron annihilation in the Milky Way, merging binary neutron stars, and dark matter can be better understood by studying their gamma ray emission. Despite their importance, MeV gamma rays have been poorly explored at sensitivities that would allow for deeper insight into the nature of the gamma emitting objects. In response, a liquid argon time projection chamber (TPC) gamma ray instrument concept called GammaTPC has been proposed and promises exploration of the entire sky with a large field of view, large effective area, and high polarization sensitivity. Optimizing the pointing capability of this instrument is crucial and can be accomplished by leveraging convolutional neural networks to reconstruct electron recoil paths from Compton scattering events within the detector. In this investigation, we develop a machine learning model architecture to accommodate a large data set of high fidelity simulated electron tracks and reconstruct paths. We create two model architectures: one to predict the electron recoil track origin and one for the initial scattering direction. We find that these models predict the true origin and direction with extremely high accuracy, thereby optimizing the observatory’s estimates of the sky location of gamma ray sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization of ray-tracing simulations to confirm performance of the GP-SANS instrument at the High-Flux Isotope Reactor

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transit telescope designs optimized for multiple object spectroscopy with fibers

Instruments to simultaneously study the spectra of many objects in the field of view of a telescope can be made using fused silica fibers. The spectrograph at the 2.3m telescope of the University of Arizona has been modified for such operation, and is used routinely to study the dynamics of galaxy clusters. Consideration has been given to how the multifiber technique can best be used to obtain spectra of the many faint objects identified by deep transit survey instruments and new space and radio telescopes. A transit survey such as that planned by McGraw et al. (1980), with CCDs at the focus of a 2m transit telescope, will identify objects down to 24th magnitude, and down to 22nd magnitude will give very complete data on variability and optical energy distribution. A telescope with much larger aperture is required for spectroscopic follow up. It is suggested that large telescopes dedicated to this type of work can be made and operated for only a fraction of the cost of a general-purpose telescope.

Angel, J. R. P.↗

Multiple-Zone Diffractive Optic Element for Laser Ranging Applications

A diffractive optic element (DOE) can be used as a beam splitter to generate multiple laser beams from a single input laser beam. This technology has been recently used in LRO s Lunar Orbiter Laser Altimeter (LOLA) instrument to generate five laser beams that measure the lunar topography from a 50-km nominal mapping orbit (see figure). An extension of this approach is to use a multiple-zone DOE to allow a laser altimeter instrument to operate over a wider range of distances. In particular, a multiple-zone DOE could be used for applications that require both mapping and landing on a planetary body. In this case, the laser altimeter operating range would need to extend from several hundred kilometers down to a few meters. The innovator was recently involved in an investigation how to modify the LOLA instrument for the OSIRIS asteroid mapping and sample return mission. One approach is to replace the DOE in the LOLA laser beam expander assembly with a multiple-zone DOE that would allow for the simultaneous illumination of the asteroid with mapping and landing laser beams. The proposed OSIRIS multiple-zone DOE would generate the same LOLA five-beam output pattern for high-altitude topographic mapping, but would simultaneously generate a wide divergence angle beam using a small portion of the total laser energy for the approach and landing portion of the mission. Only a few percent of the total laser energy is required for approach and landing operations as the return signal increases as the inverse square of the ranging height. A wide divergence beam could be implemented by making the center of the DOE a diffractive or refractive negative lens. The beam energy and beam divergence characteristics of a multiple-zone DOE could be easily tailored to meet the requirements of other missions that require laser ranging data. Current single-zone DOE lithographic manufacturing techniques could also be used to fabricate a multiple-zone DOE by masking the different DOE zones during the manufacturing process, and the same space-compatible DOE substrates (fused silica, sapphire) that are used on standard DOE s could be used for multiple- zone DOE s. DOEs are an elegant and cost-effective optical design option for spacebased laser altimeters that require multiple output laser beams. The use of multiple-zone DOEs would allow for the design and optimization of a laser altimeter instrument required to operate over a large range of target distances, such as those designed to both map and land on a planetary body. In addition to space-based laser altimeters, this technology could find applications in military or commercial unmanned aerial vehicles (UAVs) that fly at an altitude of several kilometers and need to land. It is also conceivable that variations of this approach could be used in land-based applications such as collision avoidance and robotic control of cars, trains, and ships.