Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inlet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

ECAR-5067 Computational Evaluation on Effect of Edge-rounding in Circular to Annular Flow Transitions within a Hexagonal Duct

In this ECAR, the computational fluid dynamics (CFD) simulation of the duct with a cross-section varying from circle to annulus was performed to evaluate the effect of edge-rounding of the internal edges. The edge of circular channel and the edge of inner annular channel were rounded with the radius of curvature ranged from 0 mm to 20 mm. The CFD results show that the pressure loss of the duct can be reduced by increasing the radius of the rounded edge. Case-A results showed that the pressure drop can be significantly reduced by the edge-rounding, e.g., the pressure drop was reduced approximately 56% by the radius of curvature of 5.0mm, and reduced 70% by the radius of curvature of 20.0 mm although its effectiveness would be attenuated as the radius of curvature of edge increases. Results from Case-B showed the impact of rounding the inlet edge was practically negligible compared to the outlet edge. This ECAR could provide a guideline to determine the optimum inlet module design of the VTR fuel rod bundle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Multi-Tube Mixer Combustion for 65% Efficiency (Final Report)

This project targeted advanced low NOx combustion for advanced gas turbines capable of 65%, or greater, efficiency in combined cycle application. This technology advancement has further potential to benefit gas turbines used in coal based IGCC applications with pre-combustion carbon capture and hydrogen as the resulting fuel. The program developed and synthesized the most advanced combustion system capable of achieving low NOX emissions up to turbine inlet temperatures of 3100F while also supporting the load-following needs of a modern grid. The combustion system contributes to the overall gas turbine efficiency goal by setting the maximum cycle temperature achievable for a given NOX level and by minimizing the through-combustor air flow pressure drop. Focus areas for this project targeted maximizing the turbine inlet temperature entitlement, as constrained by emissions considerations. The design also minimized parasitic air flow pressure drop by using advanced cooling techniques and performance materials selections and by minimizing hot surface area. These two technology objectives (maximum, emissions-compliant cycle temperature and minimum air flow pressure drop) were integrated into a prototype design. The primarily analytical project sought to identify the most promising technologies to meet these objectives. Additional critical “jugular” data were obtained from multi-tube mixer tests to realize the potential of leveraging “micro flames” for minimizing overall hot surface area. This data was used, in conjunction with an understanding of advanced material and cooling design technologies, to analytically develop multiple design concepts. Phase I focused on in-depth engineering analysis and design, with minimal supporting laboratory testing to enable a selection of the top three combustion architectures for achieving these overall objectives. Phase II of the program developed the selected design through a combination of sub-scale testing and analytical efforts. Early tests included a cold-flow cascade to establish aerodynamic performance characteristics and a sub-scale fired test at GE Global Research in Niskayuna, NY, to establish cooling and heat transfer characteristics in conjunction with combustion performance. The data from these tests validated the analytical models to ultimately design a full-scale, test article to evaluate at prototypical pressure and temperature conditions at GE Gas Power’s Gas Turbine Technology Laboratory in Greenville, SC. GE Gas Power also developed, tested, and recommended a suitable seal design to be applied to the unique features of the combustor. To assess the technology challenges from prospective future production of the combustor from a ceramic matrix composite material, screening tests of Environmental Barrier Coatings were completed.

20 FOSSIL-FUELED POWER PLANTS↗

KIPT ADS Target Cooling Analyses by MCNP/Fluent

This report presents multi-physics analyses of the target cooling system of the accelerator driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target using a mesh-tally. The mesh-tally data have been imported in Fluent by a C subroutine that has been compiled and linked to Fluent as a user defined function. The KIPT ADS is in operation and Fluent used the CAD model from the manufacturing process of the target. The Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator control or the primary water coolant pump. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. If the water coolant mass flow decreases to 25%, the water maximum temperature exceeds the boiling point. However, the transient analysis showed that the target cooling system can operate for 180 seconds when the inlet water mass flow rate is decreased down by 50%.

42 ENGINEERING↗

Thermal-Hydraulics Modeling and Simulations of Hot Pool Using the SAS-CFD Coupled Code

The main goal of this activity is to test the dynamic coupling of the SAS4A/SASSYS-1 (SAS) and CFD models, using a recently patched version of the SAS code intended to address an undocumented limitation that hindered the Versatile Test Reactor (VTR) simulation efforts in FY21. As described in previous VTR calculation reports, the undocumented limitation in SAS v5.4 does not allow the user to activate the CFD coupling option during restart calculations. Since the analysts were unaware of this limitation, prior SAS-CFD simulation results for the protected station blackout (PSBO) transient were erroneous. Root-cause analysis was performed to determine the cause of this undocumented limitation in SAS v5.4, the SAS software was updated in a new patch, and the SAS-CFD simulations were repeated with this patched software. The results of the SAS-CFD simulations documented in this report show that the software patch does address the cited issue, and that the patched software indeed supports the activation of the CFD coupling model in restart calculations. The SAS development team will determine the schedule for implementing the patch in an official software release. This report documents updated SAS-CFD simulations of the PSBO transient response in the VTR. The hot pool is modeled with the CFD code STAR-CCM+, which is coupled at the flow boundaries to the SAS model of the primary heat transport system. SAS computes the mass flow rate and temperature at each core subassembly outlet, the thermal insulation cavity bypass, and the IHX inlet windows. CFD in turn computes the absolute pressure and temperature at each of these boundaries. The SAS code will ignore the temperature data at flow boundaries where flow is directed into the hot pool, i.e., at the core subassembly outlets unless flow reversal occurs. Similarly, CFD will ignore temperature data at boundaries where the flow is directed out of the hot pool, i.e., at the IHX inlets except under flow reversal. The focus of this work is to ensure that the SAS software patch addresses the undocumented limitation described in prior VTR calculation reports, rather than the accurate assessment of thermal stratification in the VTR during protected transients. This motivates the development of a new, simplified CFD model with a coarser mesh to accelerate the testing process. The updated model, and simplifying assumptions, are documented in this report. In future work, the thermal stratification assessment should be performed in more detail. The simplified CFD model can be improved by performing grid convergence studies sensitivity studies of turbulence parameters (e.g., Prandtl number, turbulence production and dissipation parameters) on temperature distributions and thermal stratification.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of NEAMS Tools Using MSRE Data

This report documents the benchmarks developed and performed for the tools and codes developed under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program utilizing the MSRE experiment data. There are three focus areas explored in this work: fuel evolution, CFD, and system transient analyses. Fuel depletion is important for MSR reactor physics and fuel cycle analysis. Fuel depletion capability is currently being developed in the Griffin reactor physics code. To support this, a benchmark problem is developed using the MSRE data and an existing depletion code with flowing fuel analysis functionality (ADDER) to validate this new capability in Griffin. The ADDER calculation is compared with the TRITON-MSR results as well as the MSRE experimental data. This benchmark can be directly used to verify and validate the Griffin fuel depletion capability in future years. For CFD simulation, the MSRE CAD model is obtained from the Copenhagen Atomics and a mesh is generated for the MSRE inlet plenum. The Nek5000 code will be employed to find the flow distribution in the MSRE inlet plenum based on the mesh generated. For system analysis, a simple benchmark problem for three types of MSR system transients is developed. The SAM and SPECTRA codes are used to solve the simple problem, and the results from the two codes agree well. The SAM code is also employed to obtain the frequency response of the MSRE system at the 5 and 8 MWt power levels. The results agree well with the experiment measurements. These verification and validation efforts gives SAM users more confidence in MSR system transient simulations using SAM. Lastly, the SAM-Griffin Multiphysics coupling work is initiated. A simple one-way coupling of evaluating the precursor drift effect on the MSRE k-eff is demonstrated. This preliminary coupling work serves as the basis for future more complex Multiphysics simulation and modelling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of Reactor Design and Optimization for Scale-Up of the Catalyxx Process for Ethanol Conversion to Higher Alcohol Biofuels

This report summarizes the results of a collaborative efforts between Oak Ridge National Laboratory (ORNL) and Catalyxx Inc. to investigate scale-up of Catalyxx’s Ethanol upgrading to higher alcohols process. The study was funded by the U.S. Department of Energy (DOE) Bioenergy Technologies Office (BETO) under CRADA (Cooperative Research and Development Agreement) No: NFE-20-08396. The project is part of the Direct Funding Opportunity (DFO) for Computational Science to Enable Bioenergy program which utilized computational toolsets developed by the Consortium for Computational Physics and Chemistry, a multi-laboratory consortium in BETO. The report here summarizes a packed-bed reactor modeling effort spanning the range from lab to industrial scale (from 4 gram to 5-ton catalyst beds), and examining reactor design, process optimization strategies, and suggested design and operating conditions for Catalyxx’s ethanol upgrading plants. The results in this report have been shared in monthly steering meetings and presentations are available in the shared data house owned by Catalyxx. The modeling effort helped to define optimum operation conditions for maximum alcohol selectivity and yield: i.e., temperature control scenarios ranging from adiabatic to isothermal, feed rate, pressure, and inlet H 2 /Ethanol ratio. The modeling results were verified at lab-(4 gram) and pre-pilot (4 kg) scales and has been used to evaluate a 5-ton packed-bed reactor and identify operating conditions to maximize the butanol yield. Special focus was given to understanding mass-transfer effects in the pre-pilot and pilot-scale reactors, over the domain of flow rate, pressure, feed composition, pellet size, shape, porosity, bed voidage, and reactor dimensions (i.e., length/diameter). Modeling was also used to evaluate innovative reactor design concepts such as water removal to improve alcohol selectivity and yield, and a reactor with an additional side inlet to facilitate quenching. These concepts were thoroughly explored, and potential benefits were disclosed. The results in this report are summarized and described qualitatively to protect the IP rights of Catalyxx. The details have been shared with the Catalyxx team in the regular steering meetings. At the end of the project, Catalyxx Inc. announced a successful demonstration of pilot scale operation in Seville, Spain.

02 PETROLEUM↗

Flow rate optimization for a small liquid argon system at Fermilab.

This analysis highlights the dominant role of pressure loss in filter disks, emphasizing its crucial consideration during the design phase to ensure optimal fluid flow. Additionally, the significance of vapor quality at the transfer line inlet is identified as a key factor impacting the fill rate. Reducing inlet vapor quality and exploring the use of subcooled liquid are recommended approaches to enhance system performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems How Mohawk and Velo3Dare Printing the Future of Energy

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

Narrow-Channel, Fluidized Beds for Effective Particle Thermal Energy Transport and Storage

Colorado School of Mines (Mines) led this program in collaboration with Sandia National Laboratories (Sandia) to characterize narrow-channel fluidized beds of aluminosilicate particles – supplied by Carbo Ceramics – as a means for releasing high-temperature thermal energy in particle heat exchangers and for capturing concentrated solar energy in indirect particle receivers. Single-channel, heat transfer experiments at Mines and reduced-order 1-D models and 3-D two-fluid, CFD models explored many aspects of counterflow, bubbling fluidized beds (net downward particle flow and upward gas flow) for enhancing particle-wall heat transfer at elevated temperatures. Results at Mines on single-channel test sections consistently showed that mild bubbling fluidization increases particle-wall heat transfer coefficients (h T,w ) regularly by more than 4.0x over h T,w values without fluidization at similar conditions (mean particle diameter d p , bed depth Δz b , and bed particle temperatures T p ). Insights from lab-scale tests and modeling studies provided Nusselt number correlations for h T,w and informed the design and fabrication (by Vacuum Process Engineering) of a nominal 40-kWth, particle-sCO 2 plate heat exchanger (HX) with 12 parallel narrow-channel, fluidized beds bounded by stainless-steel walls with embedded microchannels for high-pressure sCO 2 flows. Tests of the 40-kW th HX at the particle-sCO 2 HX test stand at Sandia's National Solar Thermal Test Facility (NSTTF) were limited, due to HX design, to particle inlet temperatures T p,in ≤ 520°C with maximum sCO 2 outlet temperatures T sCO2,out ≈ 440°C, which are well below design conditions for a primary HX in a sCO 2 power cycle for a Gen-3 concentrating solar power (CSP) plant. Total heat transfer $\dot{Q}_{HX}$ remains relatively constant with increased fluidization for fixed particle and sCO 2 inlet conditions because higher h T,w due to fluidization is offset by increased axial dispersion, which suppresses temperature differences between the particles and sCO 2 in the counterflow configuration. The axial dispersion reduces the effective overall heat transfer coefficient U based on T p,in to values around 200 W m -2 K -1 .

14 SOLAR ENERGY↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Natural Gas Combined Cycle (NGCC) Power Plants with Carbon Capture and Exhaust Gas Recycle (EGR)

The purpose of this study is to determine the cost and performance of natural gas combined cycle (NGCC) power plants using state-of-the-art gas turbines with post combustion carbon capture and recycle streams designed to increase the CO 2 concentration in the inlet to the capture system. Increasing the inlet CO 2 concentration by exhaust gas recycle (EGR) is expected to improve the efficiency of the capture system and reduce its costs. Primary results indicate that adding EGR to NGCC plants with CO 2 capture results in minimal improvement to the cost of electricity. The addition of 50 percent EGR in NGCC plants with CO 2 capture reduces the LCOE by 2 percent over the LCOE of the same design without EGR as reference. Including the EGR ductwork and cooler in a greenfield plant design could still be prudent since there is some cost advantage to EGR and it would allow more flexibility for taking advantage of future improvements in the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Lignetics CRADA closeout report

Lignetics is one of the leading domestic producers of wood pellet fuels used for domestic heating. The company also produces pellets for other applications including animal bedding. The primary feedstock used for the production of Lignetics products is woody biomass. To improve the economics of pellet production, Lignetics is evaluating advanced preprocessing technologies developed by researchers at INL. In the proposed project, INL and Lignetics will work collaboratively to assess the feasibility of integrating INL’s advanced preprocessing technologies (fractional milling, high moisture pelleting and low temperature drying) in Lignetics production facilities. The successful completion of the project relies on the integration of the fractional milling and high moisture pelleting (HMP) process and low temperature drying to improve the economics of woody biomass pellet production for use in biofuel and bioproduct applications. In the HMP process, the biomass loses some moisture during compression and extrusion through the pellet die due frictional heat developed. Also, as pellets have a definite size and shape, they can be further dried in low temperature grain or belt dryers. Belt dryers are better suited to take advantage of low-grade and waste heat because they operate at lower temperatures than rotary dryers (Tumuluru et al.) Rotary dryers, for example, typically require inlet temperatures of 260°C, but more optimally operate around 400°C. In contrast, the inlet temperature of a belt dryer, such as a commercially available vacuum dryer, can be as low as 10°C above the ambient temperature, although more typically they operate at higher temperatures, between 90°C and 200°C. Because of their lower temperature operation, fire hazards and emissions to the air are lower for belt dryers in addition to reducing drying and overall pelleting costs, INL’s technology also has potential to reduce emissions at Lignetics facilities.

09 BIOMASS FUELS↗

Low Cost Glass-Ceramic Matrix Composites for Harsh Environment Heat Exchangers (Final Technical Report)

Nearly all high temperature heat exchangers are currently constructed from metallic alloys that can have good capability but are limited to hot inlet temperatures in the range of 1,200 to 1,400 °F. In general, increasing the hot inlet temperature will improve existing application cycles to operate more efficiently, and it will enable new application cycles to be viable that otherwise would not be. The objective of this project was to mature the technologies associated with the development of a ceramic-class heat exchanger that would significantly increase the operating temperature to 1,600 °F and above. The approach taken was to use Glass-Ceramic Matrix Composite (G-CMC) material and to fabricate coupon-scale tube sheet heat exchangers (HXs) to identify risks, refine details of the process and develop a pathway for this novel approach.

36 MATERIALS SCIENCE↗

CFD and systems engineering to minimize membrane-based carbon capture costs

In this study, we propose a superstructure for membrane-based carbon capture, addressing these challenges through the formulation of an optimization problem. The case study considers a flue gas with a flowrate of 1000 mol/s and a 30 % CO2 (molar basis), which is representative of steel plants. Reduced models, derived from rigorous CFD simulations of membrane modules, are utilized to enhance the efficiency of the optimization process. The reduced model includes specific input variables such as inlet flow rate, retentate and permeate pressures, and inlet CO2 concentration; while the CO2 recovery and purity in the permeate side are considered as output variables. In this way, we exploit the information from the CFD simulations in the superstructure, aiding in the selection of the optimal configuration for the multi-stage membrane process. The results underscore the efficiency of a multi-stage membrane design, showing capture costs around 45 $/t-CO2.

Pedrozo, Hector A.↗