Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Industry Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Monolithic GaAs digitizer for space-based laser pulse spreading effect

A 6-bit 1-GHz digitizer was designed to analyze the 1-ns pulse spreading effects in a space based altimeter. The digitizer consisted of four 4-bit flash A/D converters and a 6-bit encoder. Also, the converter utilized four 4-bit converters and a 4-to-6 bit encoder to achieve 6 bit resolution at the 1 GHz sample rate. The design was unique because it utilized only the inverters and NOR gates for the converters and encoder, hence it could be fabricated using the existing state-of-the-art GaAs processing techniques. This GHz digitizer has many commercial applications. It could be applicable to: (1) digital microwave transmission system for the telecommunication industries, (2) pulse monitoring in high kinetic chemical reactions, (3) transient signals in the medical field, and (4) microwave signals in astronomy.

Lao, Bennig↗

Cloud Mask Intercomparison eXercise (CMIX): An evaluation of cloud masking algorithms for Landsat 8 and Sentinel-2

Cloud cover is a major limiting factor in exploiting time-series data acquired by optical spaceborne remote sensing sensors. Multiple methods have been developed to address the problem of cloud detection in satellite imagery and a number of cloud masking algorithms have been developed for optical sensors but very few studies have carried out quantitative intercomparison of state-of-the-art methods in this domain. This paper summarizes results of the first Cloud Masking Intercomparison eXercise (CMIX) conducted within the Committee Earth Observation Satellites (CEOS) Working Group on Calibration & Validation (WGCV). CEOS is the forum for space agency coordination and cooperation on Earth observations, with activities organized under working groups. CMIX, as one such activity, is an international collaborative effort aimed at intercomparing cloud detection algorithms for moderate-spatial resolution (10–30 m) spaceborne optical sensors. The focus of CMIX is on open and free imagery acquired by the Landsat 8 (NASA/USGS) and Sentinel-2 (ESA) missions. Ten algorithms developed by nine teams from fourteen different organizations representing universities, research centers and industry, as well as space agencies (CNES, ESA, DLR, and NASA), are evaluated within the CMIX. Those algorithms vary in their approach and concepts utilized which were based on various spectral properties, spatial and temporal features, as well as machine learning methods. Algorithm outputs are evaluated against existing reference cloud mask datasets. Those datasets vary in sampling methods, geographical distribution, sample unit (points, polygons, full image labels), and generation approaches (experts, machine learning, sky images). Overall, the performance of algorithms varied depending on the reference dataset, which can be attributed to differences in how the reference datasets were produced. The algorithms were in good agreement for thick cloud detection, which were opaque and had lower uncertainties in their identification, in contrast to thin/semi-transparent clouds detection. Not only did CMIX allow identification of strengths and weaknesses of existing algorithms and potential areas of improvements, but also the problems associated with the existing reference datasets. The paper concludes with recommendations on generating new reference datasets, metrics, and an analysis framework to be further exploited and additional input datasets to be considered by future CMIX activities.

Sergii Skakun↗

FTIR quantification of industrial hydraulic fluids in perchloroethylene

The purpose of this summer research project was to investigate whether perchloroethylene can be used as a solvent for the quantitative analysis of industrial hydraulic fluids by infrared spectroscopy employing Beer's law. Standard calibration curves using carbon-hydrogen stretching (generic) and ester absorption peaks were prepared for a series of standard dilutions at low ppm levels of concentration of seven hydraulic fluids in perchloroethylene. The absorbance spectras were recorded with 1.5-10 mm fixed and variable path length sample cells made of potassium bromide. The results indicate that using ester infrared spectral peak, it is possible to detect about 20 ppm of the hydraulic fluid in perchloroethylene.

Mehta, Narinder K.↗

New Developments in NASA's Rodent Research Hardware for Conducting Long Duration Biomedical and Basic Research in Space

Animal models, particularly rodents, are the foundation of pre-clinical research to understand human diseases and evaluate new therapeutics, and play a key role in advancing biomedical discoveries both on Earth and in space. The National Research Councils Decadal survey emphasized the importance of expanding NASA's life sciences research to perform long duration, rodent experiments on the International Space Station (ISS) to study effects of the space environment on the musculoskeletal and neurological systems of mice as model organisms of human health and disease, particularly in areas of muscle atrophy, bone loss, and fracture healing. To accomplish this objective, flight hardware, operations, and science capabilities were developed at NASA Ames Research Center (ARC) to enhance science return for both commercial (CASIS) and government-sponsored rodent research. The Rodent Research Project at NASA ARC has pioneered a new research capability on the International Space Station and has progressed toward translating research to the ISS utilizing commercial rockets, collaborating with academia and science industry, while training crewmembers to assist in performing research on orbit. The Rodent Research Habitat provides a living environment for animals on ISS according to standard animal welfare requirements, and daily health checks can be performed using the habitats camera system. Results from these studies contribute to the science community via both the primary investigation and banked samples that are shared in publicly available data repository such as GeneLab. Following each flight, through the Biospecimen Sharing Program (BSP), numerous tissues and thousands of samples will be harvested, and distributed from the Space Life and Physical Sciences (SLPS) to Principal Investigators (PIs) through the Ames Life Science Data Archive (ALSDA). Every completed mission sets a foundation to build and design greater complexity into future research and answer questions about common human diseases. Together, the hardware improvements (enrichment, telemetry sensors, cameras), new capabilities (live animal return), and experience that the Rodent Research team has gained working with principal investigator teams and ISS crew to conduct complex experiments on orbit are expanding capabilities for long duration rodent research on the ISS to achieve both basic science and biomedical research objectives.

Shirazi, Yasaman↗

Sensory characterization of a ready-to-eat sweetpotato breakfast cereal by descriptive analysis

The sweetpotato [Ipomoea batatas (L.) Lam], an important industry in the United States, has been selected as a candidate crop to be grown on future long-duration space missions by NASA. Raw sweetpotato roots were processed into flour, which was used to formulate ready-to-eat breakfast cereal (RTEBC). Twelve trained panelists evaluated the sensory attributes of the extruded RTEBC using descriptive analysis. The samples were significantly different (P<0.05) for all attributes. Twelve perceived sensory attributes, which could be used to differentiate the appearance, texture, and flavor of sweetpotato RTEBC, were described. The data could be used to optimize the RTEBC and for designing studies to test its consumer acceptance.

NASA Discipline Life Support Systems↗

Hermetic Seal Designs for Sample Return Sample Tubes

Prototypes have been developed of potential hermetic sample sealing techniques for encapsulating samples in a ≈1-cm-diameter thin-walled sample tube that are compatible with IMSAH (Integrated Mars Sample Acquisition and Handling) architecture. Techniques include a heat-activated, finned, shape memory alloy plug; a contracting shape memory alloy activated cap; an expanding shape memory alloy plug; and an expanding torque plug. Initial helium leak testing of the shape memory alloy cap and finned shape memory alloy plug seals showed hermetic- seal capability compared against an industry standard of <1×10-8 atm-cc/s He. These tests were run on both clean tubes and dirty tubes dipped in MMS (Mojave Mars Simulant). The leak tests were also performed after thermal cycling between -135 and +55 ºC to ensure seal integrity after Martian diurnal cycles. Developmental testing is currently being done on the expanding torque plug, and expanding shape memory alloy plug seal designs. The finned shape memory alloy (SMA) plug currently shows hermetic sealing capability based on preliminary tests.

Younse, Paulo J.↗

Automating analog design: Taming the shrew

The pace of progress in the design of integrated circuits continues to amaze observers inside and outside of the industry. Three decades ago, a 50 transistor chip was a technological wonder. Fifteen year later, a 5000 transistor device would 'wow' the crowds. Today, 50,000 transistor chips will earn a 'not too bad' assessment, but it takes 500,000 to really leave an impression. In 1975 a typical ASIC device had 1000 transistors, took one year to first samples (and two years to production) and sold for about 5 cents per transistor. Today's 50,000 transistor gate array takes about 4 months from spec to silicon, works the first time, and sells for about 0.02 cents per transistor. Fifteen years ago, the single most laborious and error prone step in IC design was the physical layout. Today, most IC's never see the hand of a layout designer: and automatic place and route tool converts the engineer's computer captured schematic to a complete physical design using a gate array or a library of standard cells also created by software rather than by designers. CAD has also been a generous benefactor to the digital design process. The architect of today's digital systems creates the design using an RTL or other high level simulator. Then the designer pushes a button to invoke the logic synthesizer-optimizer tool. A fault analyzer checks the result for testability and suggests where scan based cells will improve test coverage. One obstinate holdout amidst this parade of progress is the automation of analog design and its reduction to semi-custom techniques. This paper investigates the application of CAD techniques to analog design.

Barlow, A.↗

Feasibility study of a synthesis procedure for array feeds to improve radiation performance of large distorted reflector antennas

There were several tangible products that resulted from the reflector antenna research program. The initial technical effort was to develop techniques to compensate for distortions over the surface of the main reflector of a large reflector antenna system. An in-depth investigation of this problem resulted in a new technique for the electronic correction of surface errors. A journal article on the findings describe the use of the iterative sampling method. Shortly after the 'Mission to Planet Earth' program started, we began investigating the use of large reflector antennas in geostationary orbit for passive earth remote sensing. A study panel was coordinated by Virginia Tech to set technical goals for the effort. These were used to guide the design of several antennas. The original interest stemmed from an industrial (Reynolds Metals) need and currently involves work with industry (Prodelin Corporation) on high technology, low cost reflectors. The intervening years (1987 - 1993) is the period of this report and Virginia Tech's reflector antenna activity then was exclusively with NASA LaRC.

Stutzman, W. L.↗

Bacteria Counter

Science Applications, Inc.'s ATP Photometer makes a rapid and accurate count of the bacteria in a body fluid sample. Instrument provides information on the presence and quantity of bacteria by measuring the amount of light emitted by the reaction between two substances. Substances are ATP adenosine triphosphate and luciferase. The reactants are applied to a human body sample and the ATP Photometer observes the intensity of the light emitted displaying its findings in a numerical output. Total time lapse is usually less than 10 minutes, which represents a significant time savings in comparison of other techniques. Other applications are measuring organisms in fresh and ocean waters, determining bacterial contamination of foodstuffs, biological process control in the beverage industry, and in assay of activated sewage sludge.

Source record↗

Three Methods of Detection of Hydrazines

Three proposed methods for measuring trace quantities of hydrazines involve ionization and detection of hydrazine derivatives. These methods are intended to overcome the limitations of prior hydrazine- detection methods. Hydrazine (Hz), monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH) are hypergolic fuels and are highly reactive, toxic, and corrosive. A capability to measure concentrations of hydrazines is desirable for detecting leaks and ensuring safety in aerospace settings and in some industrial settings in which these compounds are used. One of the properties (high reactivity) that make it desirable to detect trace amounts of hydrazines also makes it difficult to detect hydrazines and measure their concentrations accurately using prior methods: significant amounts are lost to thermal and catalytic decomposition prior to detection. Further complications arise from the sticky nature of hydrazines: Sample hydrazine molecules tend to become irreversibly adsorbed onto solid surfaces with which they come into contact during transport to detectors, giving rise to drift in detector responses. In each proposed method, the reactive, sticky nature of hydrazines would be turned to advantage by providing a suitably doped substrate surface with which the hydrazines would react. The resulting hydrazine derivatives would be sufficiently less sticky and sufficiently more stable so that fewer molecules would be lost to decomposition or adsorption during transport. Consequently, it would be possible to measure concentration with more sensitivity and less error than in prior techniques. The first proposed method calls for the use of a recently developed technique known as desorption electrospray ionization (DESI), in which a pneumatically assisted micro -electrospray at ambient pressure is directed at a surface of interest. In this case, the surface of interest would be that of a substrate described above.

Griffin, Timothy↗

Effect of Mechanical and Thermal Loading Histories on Residual Properties of SiCf/SiC Ceramic Matrix Composites

Silicon Carbide based Ceramic Matrix Composites (CMCs) are attractive materials for use in high-temperature structural applications in the aerospace and nuclear industries. Under high stresses and temperatures, creep degradation is the dominant damage mechanism in CMCs. Consequently, chemical vapor infiltration (CVI) SiCf/SiC ceramic matrix composites (CMC) incorporating SylramicTM-iBN SiC fibers coated with boron nitride (BN) interphase and CVI-SiC matrix were tested to examine creep behavior in air at a range of elevated temperatures of (2200 - 2700 F). Samples that survived creep tests were evaluated via RT fast fracture tensile tests to determine residual properties, with the use of acoustic emission (AE) to assess stress dependent damage initiation and progression. Microscopy of regions within the gage section of the tested specimens was performed. Observed material degradation mechanisms are discussed.

creep↗

Heat storage in alloy transformations

Heats of transformation of eutectic alloys were measured for many binary and ternary systems by differential scanning calorimetry and thermal analysis. Only the relatively cheap and plentiful elements Mg, Al, Si, P, Ca, Cu, Zn were considered. A method for measuring volume change during transformation was developed using x-ray absorption in a confined sample. Thermal expansion coefficients of both solid and liquid states of aluminum and of its eutectics with copper and with silicon also were determined. Preliminary evaluation of containment materials lead to the selection of silicon carbide as the initial material for study. Possible applications of alloy PCMs for heat storage in conventional and solar central power stations, small solar receivers and industrial furnace operations are under consideration.

Birchenall, C. E.↗

Mars Ascent Vehicle Development Status

The Mars robotic sample return mission has been a potential flagship mission for NASA s science mission directorate for decades. The Mars Exploration Program and the planetary science decadal survey have highlighted both the science value of the Mars Sample Return (MSR) mission, but also the need for risk reduction through technology development. One of the critical elements of the MSR mission is the Mars Ascent Vehicle (MAV), which must launch the sample cache from the surface of Mars and place it into low Mars orbit. The MAV has significant challenges to overcome due to tight constraints on the MAV s mass and volume, as well as environmental challenges associated with long duration storage on the Martian surface and during Entry Descent and Landing (EDL). In the fall of 2010, NASA selected three industrial partners for study phase contracts to develop MAV system concepts, identify technology needs, and recommend technology developments plans for follow-on work. In addition to the contractor recommendations, JPL s Team-X was used for a comparative assessment of the three vehicle concepts to understand relative strengths, weaknesses, and sensitivity to system growth. The GRC COMPASS team independently evaluated MAV system solutions using liquid bipropellant, solid rocket motors, and an advanced monopropellant option. The results of the study phase contracts and comparative assessment is provided herein.

Dankanich, John W.↗

A Pipeline for Assessing the Quality of Rna-Seq Datasets in GeneLab

Transcriptome profiling by RNA sequencing (RNA-seq) is a powerful approach to identify gene expression changes in organisms exposed to unique environments such as spaceflight. One of the challenges of evaluating RNA-seq data both within and across different space-relevant studies is the ability to control for technical differences, including the use of different library preparation kits, sequencing platforms, RNA yield, and person-to-person variation. To help address this issue, the National Institute of Standards and Technology (NIST, nist.gov) initiated a consortium, at the request of industry and academia, to develop a set of controls for gene expression measurements. The result was a set of 92 unlabeled, polyadenylated transcripts that range from 250 – 2,000 nucleotides in length to mimic natural eukaryotic mRNAs. These External RNA Controls Consortium (ERCC) genes can be used in any RNA-seq experiment, by adding known concentrations of the ERCC genes to samples after RNA extraction, to offer a standard measurement for data comparison. At NASA GeneLab, we employ these controls as part of our standard operating procedures for every in-house RNA-seq study to assess the limit of detection, dynamic range, and power of differential expression analysis both within and across experiments. Here we will discuss the use, benefits, and limitations of ERCC genes and other types of controls, such as universal RNA references, to generate quality control information for RNA-seq studies conducted at GeneLab.

GeneLab↗

Entry System Design Considerations for Mars Landers

The objective for the next generation or Mars landers is to enable a safe landing at specific locations of scientific interest. The 1st generation entry, descent and landing systems, ex. Viking and Pathfinder, provided successful landing on Mars but by design were limited to large scale, 100s of km, landing sites with minimal local hazards. The 2 nd generation landers, or smart landers, will provide scientists with access to previously unachievable landing sites by providing precision landing to less than 10 km of a target landing site, with the ability to perform local hazard avoidance, and provide hazard tolerance. This 2nd generation EDL system can be utilized for a range of robotic missions with vehicles sized for science payloads from the small 25-70 kg, Viking, Pathfinder, Mars Polar Lander and Mars Exploration Rover-class, to the large robotic Mars Sample Return, 300 kg plus, science payloads. The 2nd generation system can also be extended to a 3nd generation EDL system with pinpoint landing, 10's of meters of landing accuracy, for more capable robotic or human missions. This paper will describe the design considerations for 2nd generation landers. These landers are currently being developed by a consortium of NASA centers, government agencies, industry and academic institutions. The extension of this system and additional considerations required for a 3nd generation human mission to Mars will be described.

Lockwood, Mary Kae↗

Aerosol Radiative Forcing in Asian Continental Outflow

Aerosols in elevated layers were sampled with FSSP-probes and wire impactors over the Pacific ocean aboard the NASA DC-8 aircraft. Analyses of particle size and morphology identifies two distinctly different aerosol types for cases when the mid-visible extinctions exceed 0.2/km. Smaller sizes (effective radii of 0.2 um) and moderate absorption (mid-visible single scattering albedo of.935) are typical for urban-industrial pollution. Larger sizes (effective radii of 0.7 um) and weak absorption (mid-visible single scattering albedo of 0.985) identify dust. This aerosol classification is in agreement with its origin as determined by airmass back trajectory analysis. Based on lidar vertical profiling, aerosol dominated by dust and urban-industrial pollution above 3km were assigned mid-visible optical depths of 0.50 and 0.27, respectively. Radiative transfer simulations, considering a 50% cloud-cover below the aerosol layers, suggest (on a daily tP C)C> basis) small reductions (-4W/m2) to the energy budget at the top of the atmosphere for both aerosol types. For c' 0 dust, more backscattering of sunlight (weaker solar absorption) is compensated by a stronger greenhouse effect due to larger sizes. Forced reductions to the energy budget at the surface are 12W/m2 for both aerosol types. In contrast, impacts on heating rates within the aerosol layers are quite different: While urban-industrial aerosol warms the layer (at +0.6K/day as solar heating dominates), dust cools (at -0.5K/day as infrared cooling dominates). Sensitivity tests show the dependence of the aerosol climatic impact on the optical depth, particle size, absorptivity, and altitude of the layers, as well as clouds and surface properties. Climatic cooling can be eliminated (1) for the urban-industrial aerosol if absorption is increased to yield a mid-visible single scattering albedo of 0.89, or if the ocean is replaced by a land surface; (2) for the dust aerosol if the effective radius is increased from 0.7 to 1.2 um. The removal of low-level clouds doubles the cooling at the top of the atmosphere to about -8W/m2.

Pueschel, R.↗

Large-scale Distribution of CH4 in the Western North Pacific: Sources and Transport from the Asian Continent

Methane (CH4) mixing ratios in the northern Pacific Basin were sampled from two aircraft during the TRACE-P mission (Transport and Chemical Evolution over the Pacific) from late February through early April 2001 using a tunable diode laser system. Described in more detail by Jacob et al., the mission was designed to characterize Asian outflow to the Pacific, determine its chemical evolution, and assess changes to the atmosphere resulting from the rapid industrialization and increased energy usage on the Asian continent. The high-resolution, high-precision data set of roughly 13,800 CH4 measurements ranged between 1602 ppbv in stratospherically influenced air and 2149 ppbv in highly polluted air. Overall, CH4 mixing ratios were highly correlated with a variety of other trace gases characteristic of a mix of anthropogenic industrial and combustion sources and were strikingly correlated with ethane (C2H6) in particular. Averages with latitude in the near-surface (0-2 km) show that CH4 was elevated well above background levels north of 15 deg N close to the Asian continent. In the central and eastern Pacific, levels of CH4 were lower as continental inputs were mixed horizontally and vertically during transport. Overall, the correlation between CH4 and other hydrocarbons such as ethane (C2H6), ethyne (C2H2), and propane (C3H8) as well as the urban/industrial tracer perchloroethene (C2Cl4), suggests that for CH4 colocated sources such as landfills, wastewater treatment, and fossil fuel use associated with urban areas dominate regional inputs at this time. Comparisons between measurements made during TRACE-P and those of PEM-West B, flown during roughly the same time of year and under a similar meteorological setting 7 years earlier, suggest that although the TRACE-P CH4 observations are higher, the changes are not significantly greater than the increases seen in background air over this time interval.

Bartlett, Karen B.↗

Sensitive, Rapid Detection of Bacterial Spores

A method of sensitive detection of bacterial spores within delays of no more than a few hours has been developed to provide an alternative to a prior three-day NASA standard culture-based assay. A capability for relatively rapid detection of bacterial spores would be beneficial for many endeavors, a few examples being agriculture, medicine, public health, defense against biowarfare, water supply, sanitation, hygiene, and the food-packaging and medical-equipment industries. The method involves the use of a commercial rapid microbial detection system (RMDS) that utilizes a combination of membrane filtration, adenosine triphosphate (ATP) bioluminescence chemistry, and analysis of luminescence images detected by a charge-coupled-device camera. This RMDS has been demonstrated to be highly sensitive in enumerating microbes (it can detect as little as one colony-forming unit per sample) and has been found to yield data in excellent correlation with those of culture-based methods. What makes the present method necessary is that the specific RMDS and the original protocols for its use are not designed for discriminating between bacterial spores and other microbes. In this method, a heat-shock procedure is added prior to an incubation procedure that is specified in the original RMDS protocols. In this heat-shock procedure (which was also described in a prior NASA Tech Briefs article on enumerating sporeforming bacteria), a sample is exposed to a temperature of 80 C for 15 minutes. Spores can survive the heat shock, but nonspore- forming bacteria and spore-forming bacteria that are not in spore form cannot survive. Therefore, any colonies that grow during incubation after the heat shock are deemed to have originated as spores.

Kern, Roger G.↗