Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

CCD mosaic images of the supernova remnant 3C 400.2

We have constructed CCD mosaic images of the old Galactic supernova remnant 3C 400.2 in lines of H-alpha + forbidden N II, forbidden S II, and forbidden O III, plus a continuum band. These are the first CCD images covering the full extent of this remnant, and they reveal significantly more nebulosity than the deepest photographic plates. Comparison with radio and X-ray images indicates dramatically different morphology in the three regimes. The optical images both in H-alpha + forbidden N II and in forbidden S II show an almost complete, irregular shell of emission, with a diameter of about 16 arcmin, little over half that of the radio shell, while the X-ray structure is a centrally peaked ellipsoid. Approximate values for optical line fluxes are obtained; we estimate L(H-alpha) about 3 x 10 exp 35 ergs/s, roughly three times the X-ray luminosity. We also report a previously uncataloged planetary nebula southwest of 3C 400.2.

Winkler, P. F.↗

Recent developments at JPL in the application of digital image processing techniques to astronomical images

Several techniques of a digital image-processing nature are illustrated which have proved useful in visual analysis of astronomical pictorial data. Processed digital scans of photographic plates of Stephans Quintet and NGC 4151 are used as examples to show how faint nebulosity is enhanced by high-pass filtering, how foreground stars are suppressed by linear interpolation, and how relative color differences between two images recorded on plates with different spectral sensitivities can be revealed by generating ratio images. Analyses are outlined which are intended to compensate partially for the blurring effects of the atmosphere on images of Stephans Quintet and to obtain more detailed information about Saturn's ring structure from low- and high-resolution scans of the planet and its ring system. The employment of a correlation picture to determine the tilt angle of an average spectral line in a low-quality spectrum is demonstrated for a section of the spectrum of Uranus.

Lorre, J. J.↗

Improved collimator for imaging system

System's collimator, consisting of metal plate with many small-diameter holes and fiber optics scintillator, can increase system resolution to 1 mm and reduce scintillation loss to 25 percent.

Holladay, A. M.↗

Impact Induced Delamination Detection and Quantification With Guided Wavefield Analysis

This paper studies impact induced delamination detection and quantification by using guided wavefield data and spatial wavenumber imaging. The complex geometry impact-like delamination is created through a quasi-static indentation on a CFRP plate. To detect and quantify the impact delamination in the CFRP plate, PZT-SLDV sensing and spatial wavenumber imaging are performed. In the PZT-SLDV sensing, the guided waves are generated from the PZT, and the high spatial resolution guided wavefields are measured by the SLDV. The guided wavefield data acquired from the PZT-SLDV sensing represent guided wave propagation in the composite laminate and include guided wave interaction with the delamination damage. The measured guided wavefields are analyzed through the spatial wavenumber imaging method, which generates an image containing the dominant local wavenumber at each spatial location. The spatial wavenumber imaging result for the simple single layer Teflon insert delamination provided quantitative information on delamination damage size and location. The location of delamination damage is indicated by the area with larger wavenumbers in the spatial wavenumber image. The impact-like delamination results only partially agreed with the damage size and shape. The results also demonstrated the dependence on excitation frequency. Future work will further investigate the accuracy of the wavenumber imaging method for real composite damage and the dependence on frequency of excitation.

Tian, Zhenhua↗

Wedge-and-strip anodes for centroid-finding position-sensitive photon and particle detectors

The paper examines geometries employing position-dependent charge partitioning to obtain a two-dimensional position signal from each detected photon or particle. Requiring three or four anode electrodes and signal paths, images have little distortion and resolution is not limited by thermal noise. An analysis of the geometrical image nonlinearity between event centroid location and the charge partition ratios is presented. In addition, fabrication and testing of two wedge-and-strip anode systems are discussed. Images obtained with EUV radiation and microchannel plates verify the predicted performance, with further resolution improvements achieved by adopting low noise signal circuitry. Also discussed are the designs of practical X-ray, EUV, and charged particle image systems.

Martin, C.↗

The Viking Mosaic Catalog, Volume 2

A collection of more than 500 mosaics prepared from Viking Orbiter images is given. Accompanying each mosaic is a footprint plot, which identifies by location, picture number, and order number, each frame in the mosaic. Corner coordinates and pertinent imaging information are also included. A short text provides the camera characteristics, image format, and data processing information necessary for using the mosaic plates as a research aide. Procedures for ordering mosaic enlargements and individual images are also provided.

Evans, N.↗

Development efforts to improve curved-channel microchannel plates

Curved-channel microchannel plate (C-plate) improvements resulting from an ongoing NASA STIS microchannel plate (MCP) development program are described. Performance limitations of previous C-plates led to a development program in support of the STIS MAMA UV photon counter, a second generation instrument on the Hubble Space Telescope. C-plate gain, quantum detection efficiency, dark noise, and imaging distortion, which are influenced by channel curvature non-uniformities, have all been improved through use of a new centrifuge fabrication technique. This technique will be described, along with efforts to improve older, more conventional shearing methods. Process optimization methods used to attain targeted C-plate performance goals will be briefly characterized. Newly developed diagnostic measurement techniques to study image distortion, gain uniformity, input bias angle, channel curvature, and ion feedback, will be described. Performance characteristics and initial test results of the improved C-plates will be reported. Future work and applications will also be discussed.

Corbett, M. B.↗

National Diagnostic Working Group (NDWG) for inertial confinement fusion (ICF)/high-energy density (HED) science: The whole exceeds the sum of its parts

The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. Here, an abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.

47 OTHER INSTRUMENTATION↗

Leica ADS40 Sensor for Coastal Multispectral Imaging

The Leica ADS40 Sensor as it is used for coastal multispectral imaging is presented. The contents include: 1) Project Area Overview; 2) Leica ADS40 Sensor; 3) Focal Plate Arrangements; 4) Trichroid Filter; 5) Gradient Correction; 6) Image Acquisition; 7) Remote Sensing and ADS40; 8) Band comparisons of Satellite and Airborne Sensors; 9) Impervious Surface Extraction; and 10) Impervious Surface Details.

Craig, John C.↗

Explosion dynamics of thin flat foils at high current density

This paper presents characteristic features of the explosion of thin flat foils for currents and pulse risetimes ranging from 8 kA at 350 ns to 1000 kA at ~100 ns. Foils made of aluminum, copper, nickel, and titanium with thicknesses of 1–100 µm are tested. Various diagnostics in the optical, UV, and x-ray spectral ranges are used to image the exploding foils from initial breakdown to complete destruction or pinching. It is shown that foil explosion is a complex process that depends on many factors, but features common to all foils are found that do not depend on the parameters of the generators or, accordingly, on the energy deposited in the foil: for example, the breakdown of flat foils under different conditions occurs at the edges of the foil. For the first time, the formation of a precursor over the central part of the foil is shown, which significantly changes the dynamics of the foil explosion.

36 MATERIALS SCIENCE↗

Deconvolution of a pre-outburst picture of SN 1987A

The block iterative method (Young 1971) of algebraic image restoration is applied to a photographic plate of the field around SN 1987A obtained 4 yr before outburst by Chu at the CTIO 4-m telescope. By setting appropriate constraints for the solution on a pixel-by-pixel basis, the image of a starfield centered on Sk -69 202, the precursor to the supernova, is restored. It is found that this star has two companions, which others (e.g., Walborn et al., 1987 and West et al., 1987) have also noted and designated as Star 2 and Star 3. Also found is marginal evidence for Star 4, a weak source at theta = 222 deg, r = 1.9 arcsec. Correction for the contributions of these companions yields an estimate of the magnitude for Sk -69 202 alone of V = 12.37.

Heap, Sara R.↗

High-Performance Scanning Acousto-Ultrasonic System

A high-performance scanning acousto-ultrasonic system, now undergoing development, is designed to afford enhanced capabilities for imaging microstructural features, including flaws, inside plate specimens of materials. The system is expected to be especially helpful in analyzing defects that contribute to failures in polymer- and ceramic-matrix composite materials, which are difficult to characterize by conventional scanning ultrasonic techniques and other conventional nondestructive testing techniques. Selected aspects of the acousto-ultrasonic method have been described in several NASA Tech Briefs articles in recent years. Summarizing briefly: The acousto-ultrasonic method involves the use of an apparatus like the one depicted in the figure (or an apparatus of similar functionality). Pulses are excited at one location on a surface of a plate specimen by use of a broadband transmitting ultrasonic transducer. The stress waves associated with these pulses propagate along the specimen to a receiving transducer at a different location on the same surface. Along the way, the stress waves interact with the microstructure and flaws present between the transducers. The received signal is analyzed to evaluate the microstructure and flaws. The specific variant of the acousto-ultrasonic method implemented in the present developmental system goes beyond the basic principle described above to include the following major additional features: Computer-controlled motorized translation stages are used to automatically position the transducers at specified locations. Scanning is performed in the sense that the measurement, data-acquisition, and data-analysis processes are repeated at different specified transducer locations in an array that spans the specimen surface (or a specified portion of the surface). A pneumatic actuator with a load cell is used to apply a controlled contact force. In analyzing the measurement data for each pair of transducer locations in the scan, the total (multimode) acousto-ultrasonic response of the specimen is utilized. The analysis is performed by custom software that extracts parameters of signals in the time and frequency domains. The computer hardware and software provide both real-time and postscan processing and display options. For example, oscilloscope displays of waveforms and power spectral densities are available in real time. Images can be computed while scanning continues. Signals can be digitally preprocessed and/or post-processed by filtering, windowing, time-segmenting, and running-waveform-averaging algorithms. In addition, the software affords options for off-line simulation of the waveform-data-acquisition and scanning processes. In tests, the system has been shown to be capable of characterizing microstructural changes and defects in SiC/SiC and C/SiC ceramic-matrix composites. Delaminations, variations in density, microstructural changes attributable to infiltration by silicon, and crack-space indications (defined in the next sentence) have been revealed in images formed from several time- and frequency-domain parameters of scanning acousto-ultrasonic signals. The crack-space indications were image features that were not revealed by other nondestructive testing methods and are so named because they turned out to mark locations where cracking eventually occurred.

Roth, Don↗

Segmented cold cathode display panel

The present invention is a video display device that utilizes the novel concept of generating an electronically controlled pattern of electron emission at the output of a segmented photocathode. This pattern of electron emission is amplified via a channel plate. The result is that an intense electronic image can be accelerated toward a phosphor thus creating a bright video image. This novel arrangement allows for one to provide a full color flat video display capable of implementation in large formats. In an alternate arrangement, the present invention is provided without the channel plate and a porous conducting surface is provided instead. In this alternate arrangement, the brightness of the image is reduced but the cost of the overall device is significantly lowered because fabrication complexity is significantly decreased.

Payne, Leslie↗

Full-field quantitative visualization of shock-driven pore collapse and failure modes in PMMA

The dynamic collapse of pores under shock loading is thought to be directly related to hot spot generation and material failure, which is critical to the performance of porous energetic and structural materials. However, the shock compression response of porous materials at the local, individual pore scale is not well understood. This study examines, quantitatively, the collapse phenomenon of a single spherical void in PMMA at shock stresses ranging from 0.4 to 1.0 GPa. Using a newly developed internal digital image correlation technique in conjunction with plate impact experiments, full-field quantitative deformation measurements are conducted in the material surrounding the collapsing pore for the first time. The experimental results reveal two failure mode transitions as shock stress is increased: (i) the first in situ evidence of shear localization via adiabatic shear banding and (ii) dynamic fracture initiation at the pore surface. Numerical simulations using thermo-viscoplastic dynamic finite element analysis provide insights into the formation of adiabatic shear bands (ASBs) and stresses at which failure mode transitions occur. Further numerical and theoretical modeling indicates the dynamic fracture to occur along the weakened material inside an adiabatic shear band. Finally, analysis of the evolution of pore asymmetry and models for ASB spacing elucidate the mechanisms for the shear band initiation sites, and elastostatic theory explains the experimentally observed ASB and fracture paths based on the directions of maximum shear.

42 ENGINEERING↗

Instrumentation development for the EUVE

The prototype mirror was successfully replated with a thick layer of nickel and diamond turned again. Optimization of the sensitivity of the instruments was studied with emphasis on the filter material, and on the available telemetry. The JHU Preliminary Project Definition Document was critically analyzed. Further studies of the electron cloud distribution produced by a channel plate were performed, and a wedge and strip anode with 17 quartets per inch was shown to image with better than 0.5% linearity. Half the microchannel plates being used in the lifetest completed initial processing and are in the lifetest vacuum chamber.

Finley, D.↗

A Novel Ultrasonic Method for Characterizing Microstructural Gradients in Tubular Structures

Ultrasonic velocity and time-of-flight (TOF) imaging that uses back surface reflections to gage volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse echo ultrasonic velocity and TOF imaging is that the image shows the effects of thickness as well as microstructural variations, unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse echo TOF based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples which, eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material in plate like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex shaped structures- those having (hollow) tubular or curved geometry. The experimental inspection technique and results are described as applied to a polymer matrix composite "proof of concept" tube that contains machined patches of various depths and an as manufactured monolithic silicon nitride ceramic tube that might be used in "real world" applications.

Roth, Don J.↗

Images of the future - Two decades in astronomy

Future instruments for the 100-10,000 A UV-wavelength region will require detectors with greater quantum efficiency, smaller picture elements, a greater wavelength range, and greater active area than those currently available. After assessing the development status and performance characteristics of vidicons, image tubes, electronographic cameras, digicons, silicon arrays and microchannel plate intensifiers presently employed by astronomical spacecraft, attention is given to such next-generation detectors as the Mosaicked Optical Self-scanned Array Imaging Camera, which consists of a photocathode deposited on the input side of a microchannel plate intensifier. The problems posed by the signal processing and data analysis requirements of the devices foreseen for the 21st century are noted.

Weistrop, D.↗

Readout techniques for photon-counting microchannel image systems

A comparative evaluation is made of such readout methods for the microchannel plates that are commonly used in EUV, FUV, and X-ray low light level image systems as the (1) phosphor-video, (2) phosphor and binary-mask encoder, (3) direct discrete-position encoder, (4) direct analog amplitude position-encoder systems, and (5) delay-line encoders. Relative advantages and limitations are discussed in the context of low light level space-based astronomy applications. The delay-line technique offers great promise for high-resolution applications where oversampling is mandatory, as in spectroscopy.

Lampton, Michael↗