Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISAACS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Baryogenesis in a parity solution to the strong CP problem

Abstract Space-time parity can solve the strong CP problem and introduces a spontaneously broken SU(2) R gauge symmetry. We investigate the possibility of baryogenesis from a first-order SU(2) R phase transition similar to electroweak baryogenesis. We consider a model with the minimal Higgs content, for which the strong CP problem is indeed solved without introducing extra symmetry beyond parity. Although the parity symmetry seems to forbid the SU(2) R anomaly of theB−Lsymmetry, the structure of the fermion masses can allow for the SU(2) R sphaleron process to produce non-zeroB−Lasymmetry of Standard Model particles so that the wash out by the SU(2) L sphaleron process is avoided. The setup predicts a new hyper-charged fermion whose mass is correlated with the SU(2) R symmetry breaking scale and hence with the SU(2) R gauge boson mass, and depending on the origin of CP violation, with an electron electric dipole moment. In a setup where CP violation and the first-order phase transition are assisted by a singlet scalar field, the singlet can be searched for at future colliders.

Physics↗

The Monitoring Network of the Vancouver 2010 Olympics

Abstract—An innovative monitoring network was implemented to support the operational and science programs for the Vancouver 2010 Winter Olympics. It consisted of in situ weather stations on custom-designed platforms. The sensors included an HMP45C for temperature, humidity and pressure, a tipping bucket rain gauge, an acoustic snow depth sensor, a Pluvio 1 precipitation gauge and an anemometer placed at gauge height and at 10 m height. Modifications to commercial automated precipitation gauges were necessary for the heavy snowfall conditions. Advanced or emerging technologies were deployed to support scientific and nowcasting studies into precipitation intensity, typing, visibility and wind. The sensors included an FD12P visibility and precipitation sensor, a precipitation occurrence sensing system (POSS) present weather sensor, a Hotplate precipitation sensor and a Parsivel disdrometer. Data were collected at 1 min sampling intervals. A Doppler weather radar was deployed in a valley location and provided critical detailed low-level data. An X-band dual-polarized radar was deployed by the National Oceanic and Atmospheric Administration to monitor Vancouver and Cypress Mountain. Three remote sensing stations for vertical profiling were established. At the base of Whistler Mountain, a micro-rain radar, a 22-channel radiometer, a ceilometer, a Parsivel and a POSS were installed. At the base of Cypress Mountain, a micro-rain radar, a ceilometer, a low cost rain sensor (LCR by ATTEX) and a POSS were installed. At Squamish, a wind profiler and a POSS were installed. Weather sensors were mounted on the Whistler Village Gondola and on the Peak to Peak gondola. Sites were established along the Whistler Mountain slope and at other key locations. The combination of sites and instruments formed a comprehensive network to provide observations appropriate for nowcasting in winter complex terrain and investigate precipitation, visibility and wind processes. The contribution provides a detailed description of the network, their sensors, the innovations and some examples.

Joe, Paul↗

Development of Friction Stir Welding Technologies for In-Space Manufacturing

Friction stir welding (FSW) has emerged as an attractive process for fabricating aerospace vehicles. Current FSW state-of-the-art uses large machines that are not portable. However, there is a growing need for fabrication and repair operations associated with in-space manufacturing. This need stems from a desire for prolonged missions and travel beyond low-earth orbit. To address this need, research and development is presented regarding two enabling technologies. The first is a self-adjusting and aligning (SAA) FSW tool that drastically reduces the axial force that has historically been quite large. The SAA-FSW tool is a bobbin style tool that floats freely, without any external actuators, along its vertical axis to adjust and align with the workpiece s position and orientation. Successful butt welding of 1/8 in. (3.175 mm) thick aluminum 1100 was achieved in conjunction with a drastic reduction and near elimination of the axial process force. Along with the SAA-FSW, an innovative in-process monitor technique is presented in which a magnetoelastic force rate-of-change sensor is employed. The sensor consists of a magnetized FSW tool that is used to induce a voltage in a coil surrounding the tool when changes to the process forces occur. The sensor was able to detect 1/16 in. (1.5875 mm) diameter voids. It is concluded that these technologies could be applied toward the development of a portable FSW machine for use in space.

42 ENGINEERING↗

Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy

Purpose: The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. Methods: Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Three observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. Results: Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan-Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). Conclusion: Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Post-Biopsy Manoeuvres to Reduce Pneumothorax Incidence in CT-Guided Transthoracic Lung Biopsies: A Systematic Review and Meta-analysis

This systematic review and meta-analysis investigated post-biopsy manoeuvres to reduce pneumothorax following computed tomography-guided percutaneous transthoracic lung biopsy. Twenty-one articles were included with 7080 patients. Chest drain insertion rates were significantly reduced by ninefold with the normal saline tract sealant compared to controls (OR 0.11, 95% CI 0.02–0.48), threefold with the rapid rollover manoeuvre to puncture site down (OR 0.34, 95% CI 0.18–0.63), threefold with the tract plug (OR 0.33, 95% CI 0.22–0.48) and threefold with the blood patch (OR 0.39, 95% CI 0.26–0.58). The absolute chest drain insertion rates were the lowest in the normal saline tract sealant (0.8% vs 7.3% for controls), rapid rollover (1.9% vs 5.2%), deep expiration and breath-hold on needle extraction (0.9% vs 1.8%) and standard rollover versus no rollover (2.6% vs 5.2%). These findings highlight post-biopsy manoeuvres which could help reduce pneumothorax and chest drain insertions following lung biopsies. Level of Evidence: Level 1/no level of evidence, systematic review.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision mass measurements of 44 V and 44m V for nucleon-nucleon interaction studies

Here, we discuss the motivation and technique of Penning trap mass spectrometry applied to radioactive 44 V and 44m V, using the LEBIT 9.4 T Penning trap mass spectrometer at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University. A complementary measurement of these nuclides, performed at the CSRe in Lanzhou, China, was recently published, but with errors several times larger than obtainable for a short-lived radionuclide in a Penning trap. Interpretation of the higher precision results is ongoing and a full accounting of this measurement is anticipated in the coming months.

44-vanadium↗

Portable C++ Code that can Look and Feel Like Fortran Code with Yet Another Kernel Launcher (YAKL)

This paper introduces the Yet Another Kernel Launcher (YAKL) C++ portability library, which strives to enable user-level code with the look and feel of Fortran code. The intended audience includes both C++ developers and Fortran developers unfamiliar with C++. The C++ portability approach is briefly explained, YAKL’s main features are described, and code examples are given that demonstrate YAKL’s usage. YAKL fills a niche capability important particularly to scientific applications seeking to port Fortran code quickly to a portable C++ library. YAKL places heavy emphasis on simplicity, readability, and productivity with performance mainly emphasizing Graphics Processing Units (GPUs). Central to YAKL’s ability to allow Fortran-like user-level code are three features: (1) a multi-dimensional Array class that allows Fortran behavior; (2) a limited library of Fortran intrinsic functions; and (3) an efficient pool allocator that transparently enables cheap frequent allocations and deallocations of YAKL Arrays. While YAKL allows Fortran-style code, it also allows Arrays that exhibit C-like behavior as well, including row-major index ordering and lower bounds of “0”. YAKL currently supports CPUs, CPU threading, and Nvidia, AMD, and Intel GPUs.

97 MATHEMATICS AND COMPUTING↗

Assay Methods for 238U, 232Th, and 210Pb in Lead and Calibration of 210Bi Bremsstrahlung Emission from Lead

Assay methods for measuring 238U, 232Th, and 210Pb concentrations in refined lead are presented. The 238U and 232Th concentrations are assayed via inductively coupled plasma mass spectrometry (ICP-MS) after anion exchange column separation on dissolved lead samples. The 210Pb concentration is inferred through α-spectroscopy of a daughter isotope, 210Po, after chemical precipitation separation on dissolved lead samples. Subsequent to the 210Po α-spectroscopy assay, a method for evaluating 210Pb concentrations in solid lead samples was developed via measurement of bremsstrahlung radiation from β-decay of a daughter isotope, 210Bi, by employing a 14-crystal array of high purity germanium (HPGe) detectors. Ten sources of refined lead were assayed. The 238U concentrations were <34 microBq/kg and the 232Th concentrations ranged <0.6 – 15 microBq/kg, as determined by the ICP-MS assay method. The 210Pb concentrations ranged from ~0.1 – 75 Bq/kg, as inferred by the 210Po α-spectroscopy assay method.

Orrell, John L.↗

Identification of background limitations to ultra-sensitive $\mathrm{LSC}$ counting through $\mathrm{ICP}$-$\mathrm{MS}$ assay of $\mathrm{LSC}$ cocktails

We report the performance of LSC cocktails in ultra-sensitive applications was evaluated. Backgrounds from radioactive contaminations in commercially available and in-house developed liquid scintillation cocktails were measured and compared to the predicted background levels of the ultra-low background liquid scintillation counter. Through the ICP-MS assay of the cocktails and their constituents, potassium impurities in the surfactant component were identified as a significant source of background, potentially limiting the use of LSC counting in ultra-sensitive applications. This work lays the groundwork for future research towards ultrapure LSC cocktails for ultrasensitive LSC counting

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of lowering potassium contamination in liquid scintillation cocktails for ultra-sensitive radiation detection

Intrinsic 40 K radioactive backgrounds from impurities of natural K in liquid scintillation cocktails have previously been demonstrated to limit their use in ultra-sensitive applications. Here, this work explores two methodologies in parallel for the reduction of 40 K backgrounds in the cocktails, and lays the groundwork for use in ultra-sensitive applications. In one method, alternative low-K liquid scintillation matrix constituents were identified and in the other, a simple purification method for single components and finished cocktails was developed. Both methods were verified via ICP-MS analysis. Liquid scintillation counting of selected purified cocktails demonstrated background reduction, improved stability, and enhanced performance. The best performing purified cocktail was also counted on a custom-built ultra-low background liquid scintillation counter, with results below the detector background.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗