Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Thickness measurement of transparent glass plates using a lateral shearing cyclic path optical configuration setup and polarization phase shifting interferometry

We present a measurement technique to determine the thickness of a transparent glass plate (GP) by using a lateral shearing cyclic path optical configuration (CPOC) setup and polarization phase shifting interferometry (PPSI). In the technique, the GP introduces a longitudinal shift in the focus of the beam and, as a result, a spherical wavefront emerges from the lens, which is otherwise set for producing a collimated beam. Using CPOC, two laterally sheared orthogonally polarized beams are generated from the incident spherical wavefront. By applying PPSI, the slope of the optical path difference variation between the laterally sheared interfering beams is evaluated, and the radius of the spherical wavefront and the longitudinal shift of the beam focus are calculated. The thickness of the GP is determined from the standard relation between the longitudinal shift of the focus introduced by the GP and the thickness of the GP. Results obtained for a GP of 9.810mm thickness are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time heterodyne speckle pattern interferometry using the correlation image sensor

A real-time method for heterodyne speckle pattern interferometry using the correlation image sensor (CIS) is proposed. The CIS demodulates the interference phase of heterodyned speckle wavefronts pixelwise at an ordinary video frame rate. The proposed method neither suffers loss of spatial resolution nor requires a high frame rate. Interferometers for out-of-plane and in-plane deformation are developed with a 200x200 pixel CIS camera. Experimental results confirm that the proposed method realizes real-time imaging of a rough-surfaced object under deformation. The average standard deviations of demodulated phase-difference images for the out-of-plane and in-plane interferometers are 0.33 and 0.13 rad, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional profiling with binary fringes using phase-shifting interferometry algorithms

Three-dimensional shape measurements by sinusoidal fringe projection using phase-shifting interferometry algorithms are distorted by the nonlinear response in intensity of commercial video projectors and digital cameras. To solve the problem, we present a method that consists in projecting and acquiring a temporal sequence of strictly binary patterns, whose (adequately weighted) average leads to a sinusoidal fringe pattern with the required number of bits. Since binary patterns consist of ''ones'' and ''zeros'' - and no half-tones are involved - the nonlinear response of the projector and the camera will not play a role, and a nearly unit contrast gray-level sinusoidal fringe pattern is obtained. Validation experiments are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase measurement in temporal speckle pattern interferometry signals presenting low-modulated regions by means of the bidimensional empirical mode decomposition

We propose a phase measurement technique to retrieve optical phase distributions coded in noisy temporal speckle pattern interferometry signals presenting regions of adjacent low-modulated pixels, which is based on the bidimensional empirical mode decomposition and the Hilbert transform. It is shown that this approach can effectively remove noise and minimize the influence of large sets of adjacent nonmodulated pixels located in the time series of speckle interferograms. The performance of the phase retrieval approach is analyzed using computer-simulated speckle interferograms modulated with a temporal carrier. The results are also compared with those given by a technique based on the one-dimensional empirical mode decomposition. The advantages and limitations of the proposed approach are finally discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Confocal simultaneous phase-shifting interferometry

In order to implement the ultraprecise measurement with large range and long working distance in confocal microscopy, confocal simultaneous phase-shifting interferometry (C-SPSI) has been presented. Four channel interference signals, with {pi}/2 phase shift between each other, are detected simultaneously in C-SPSI. The actual surface height is then calculated by combining the optical sectioning with the phase unwrapping in the main cycle of the interference phase response, and the main cycle is determined using the bipolar property of differential confocal microscopy. Experimental results showed that 1 nm of axial depth resolution was achieved for either low- or high-NA objective lenses. The reflectivity disturbance resistibility of C-SPSI was demonstrated by imaging a typical microcircuit specimen. C-SPSI breaks through the restriction of low NA on the axial depth resolution of confocal microscopy effectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional quantification of the corrosion process in metal surfaces using digital speckle pattern interferometry

The applicability of digital speckle pattern interferometry (DSPI) to the analysis of surface corrosion processes has been evaluated by studying the evolution of an Fe surface immersed in sulfuric acid. This work describes the analysis process required to obtain quantitative information about the corrosion process. It has been possible to evaluate the corrosion rate, and the results agree with those derived from the weight loss method. In addition, a two-dimensional analysis has been applied, showing that DSPI measurements can be used to extract information about the corrosion rate at any region of the surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface profile measurement in white-light scanning interferometry using a three-chip color CCD

White-light scanning interferometry (WLSI) is a useful technique to measure surface profile when a test object contains discontinuous structures or microstructures. A black and white CCD camera is usually utilized to capture interferograms, and a series of corresponding algorithms is used to achieve the profile measurement. However, the color information in the interferograms is lost. A novel profile measurement method that uses phase information in different color channels (red-green-blue) of an interferogram obtained using a three-chip color CCD in WLSI is proposed. The phase values are extracted by a windowed Fourier transform algorithm. Simulation and experimental results are presented to demonstrate the validity of the proposed method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional spectral shearing interferometry resolved in time for ultrashort optical pulse characterization

We present a new scheme for coherent measurement of ultrashort optical pulses that relies on spectral shearing interferometry combined with all-optical time gating. The spectral phase is encoded along a temporal coordinate resulting in a two-dimensional (2D) self-referenced and self-calibrating set of data. The method works without time delay between the two interfering signals. The pulse amplitude and phase are reconstructed with a high signal-to-noise ratio using a direct algorithm that applies a Fourier transform (FT) to the 2D recorded interference pattern. Characterization of low-energy, high-repetition-rate femtosecond pulses of various shapes and validation of a single-shot operation are reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis and mitigation of systematic errors in spectral shearing interferometry of pulses approaching the single-cycle limit [Invited]

We derive an analytical approximation for the measured pulse width error in spectral shearing methods, such as spectral phase interferometry for direct electric-field reconstruction (SPIDER), caused by an anomalous delay between the two sheared pulse components. This analysis suggests that, as pulses approach the single-cycle limit, the resulting requirements on the calibration and stability of this delay become significant, requiring precision orders of magnitude higher than the scale of a wavelength. This is demonstrated by numerical simulations of SPIDER pulse reconstruction using actual data from a sub-two-cycle laser. We briefly propose methods to minimize the effects of this sensitivity in SPIDER and review variants of spectral shearing that attempt to avoid this difficulty.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quadriwave Lateral Shearing Interferometry in an Achromatic and Continuously Self-imaging Regime for Future X-ray Phase Imaging

We present in this Letter a type of quadriwave lateral shearing interferometer for x-ray phase imaging. This device is based on a phase chessboard, and we take advantage of the large spectrum of the source to produce interferograms with a propagation-invariant contrast. Such a grating has been created for hard x-ray interferometry and experimentally tested on a synchrotron beamline at Soleil.

99 GENERAL AND MISCELLANEOUS↗

Density characterization of discharged gas-filled capillaries through common-path two-color spectral-domain interferometry

Electrically discharged plasma structures, typically several centimeters in length and sub-millimeter in diameter, have been applied to guide laser pulses in laser plasma accelerators and to focus ion and relativistic electron beams in compact, radially symmetric transport configurations. Knowledge of the on-axis plasma density is critical. Traditional density interferometry has been ineffective for these laser-machined structures, while group velocity delay (GVD) techniques involve combining two laser paths with corresponding alignment complexities and stability sensitivities. Here the GVD technique is advanced to a common-path two-color interferometer configuration performed in the spectral domain of a broad-bandwidth femtosecond laser. Multi-shot tracking of the phase is not required, and the common path assures improved stability. Here, this in situ technique was validated on 15 mm long plasma structures, measuring electron densities of 10 17 -10 18 cm -3 for various fill pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing Atom and Neutron Neutrality with Atom Interferometry

We propose an atom-interferometry experiment based on the scalar Aharonov-Bohm effect which detects an atom charge at the 10{sup -28} e level, and improves the current laboratory limits by 8 orders of magnitude. This setup independently probes neutron charges down to 10{sup 28} e, 7 orders of magnitude below current bounds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Globally optimal interferometry with lossy twin Fock probes

Parity or quadratic spin (e.g., J z 2 ) readouts of a Mach–Zehnder (MZ) interferometer probed with a twin Fock (TF) input state allow saturating the optimal sensitivity attainable among all mode-separable states with a fixed total number of particles but only when the interferometer phase θ is near zero. When more general Dicke state probes are used, the parity readout saturates the quantum Fisher information (QFI) at θ = 0, whereas better-than-standard quantum limit performance of the J z 2 readout is restricted to an o ( N ) occupation imbalance. We show that a method of moments readout of two quadratic spin observables J z 2 and J + 2 + J − 2 is globally optimal for Dicke state probes; i.e., the error saturates the QFI for all θ . In the lossy setting, we derive the time-inhomogeneous Markov process describing the effect of particle loss on TF states, showing that the method of moments readout of four at-most-quadratic spin observables is sufficient for globally optimal estimation of θ when two or more particles are lost. The analysis culminates in a numerical calculation of the QFI matrix for distributed MZ interferometry on the four-mode state | N 4 , N 4 , N 4 , N 4 〉 and its lossy counterparts, showing that an advantage for the estimation of any linear function of the local MZ phases θ 1 and θ 2 (compared to independent probing of the MZ phases by two copies of | N 4 , N 4 〉 ) appears when more than one particle is lost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust Optimized Pulse Schemes for Atomic Fountain Interferometry

The robustness of an atomic fountain interferometer with respect to variations in the initial velocity of the atoms and deviations from the optimal pulse amplitude is examined. We numerically simulate the dynamics of an interferometer in momentum space with a maximum separation of and map out the expected signal contrast depending on the variance of the initial velocity distribution and the value of the laser field amplitude. We show that an excitation scheme based on rapid adiabatic passage significantly enhances the expected signal contrast, compared to the commonly used scheme consisting of a series of and pulses. We demonstrate further substantial increase of the robustness by using optimal control theory to identify splitting and swapping pulses that perform well on an ensemble average of pulse amplitudes and velocities. Our results demonstrate the ability of optimal control to significantly enhance future implementations of atomic fountain interferometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Elastic Properties of β-Mg 2 SiO 4 Containing 0.73 wt.% of H 2 O to 10 GPa and 600 K by Ultrasonic Interferometry with Synchrotron X-Radiation

Here, we measured the elastic velocities of a synthetic polycrystalline β-Mg 2 SiO 4 containing 0.73 wt.% H 2 O to 10 GPa and 600 K using ultrasonic interferometry combined with synchrotron X-radiation. Third-order Eulerian finite strain analysis of the high P and T data set yielded K so = 161.5(2) GPa, G o = 101.6(1) GPa, and (∂K s /∂P) T = 4.84(4), (∂G/∂P) T = 1.68(2) indistinguishable from K so = 161.1(3) GPa, G o = 101.4(1) GPa, and (∂K s /∂P) T = 4.93(4), (∂G/∂P) T = 1.73(2) from the linear fit. The hydration of the wadsleyite by 0.73 wt.% decreases K s and G moduli by 5.3% and 8.6%, respectively, but no measurable effect was noted for (∂K s /∂P) T and (∂G/∂P) T . The temperature derivatives of the K s and G moduli from the finite strain analysis (∂K S /∂T) P = –0.013(2) GPaK –1 , (∂G/∂T) P = –0.015(0.4) GPaK –1 , and the linear fit (∂K S /∂T) P = –0.015(1) GPaK –1 , (∂G/∂T) P = –0.016(1) GPaK –1 are in agreement, and both data sets indicating the |(∂G/∂T) P | to be greater than |(∂K S /∂T) P |. Calculations yield ΔV p(α-β) = 9.88% and ΔV S(α-β) = 8.70% for the hydrous β-Mg 2 SiO 4 and hydrous α-Mg 2 SiO 4 , implying 46–52% olivine volume content in the Earth’s mantle to satisfy the seismic velocity contrast ΔV s = ΔV P = 4.6% at the 410 km depth.

58 GEOSCIENCES↗

Dispersion of magnetic fields in molecular clouds. IV. Analysis of interferometry data

We expand on the dispersion analysis of polarimetry maps toward applications to interferometry data. We show how the filtering of low spatial frequencies can be accounted for within the idealized Gaussian turbulence model, initially introduced for single-dish data analysis, to recover reliable estimates for correlation lengths of magnetized turbulence, as well as magnetic field strengths (plane-of-the-sky component) using the Davis–Chandrasekhar–Fermi method. We apply our updated technique to TADPOL/CARMA data obtained on W3(OH), W3 Main, and DR21(OH). For W3(OH), our analysis yields a turbulence correlation length δ≃19 mpc, a ratio of turbulent-to-total magnetic energy 〈B{sub t}{sup 2}〉/〈B{sup 2}〉≃0.58, and a magnetic field strength B{sub 0}∼1.1 mG; for W3 Main δ≃22 mpc, 〈B{sub t}{sup 2}〉/〈B{sup 2}〉≃0.74, and B{sub 0}∼0.7 mG; while for DR21(OH) δ≃12 mpc, 〈B{sub t}{sup 2}〉/〈B{sup 2}〉≃0.70, and B{sub 0}∼1.2 mG.

79 ASTRONOMY AND ASTROPHYSICS↗

Superresolution Full-polarimetric Imaging for Radio Interferometry with Sparse Modeling

We propose a new technique for radio interferometry to obtain superresolution full-polarization images in all four Stokes parameters using sparse modeling. The proposed technique reconstructs the image in each Stokes parameter from the corresponding full-complex Stokes visibilities by utilizing two regularization functions: the ℓ {sub 1} norm and the total variation (TV) of the brightness distribution. As an application of this technique, we present simulated linear polarization observations of two physically motivated models of M87 with the Event Horizon Telescope. We confirm that ℓ {sub 1}+TV regularization can achieve an optimal resolution of ~25%–30% of the diffraction limit λ/D{sub max}, which is the nominal spatial resolution of a radio interferometer for both the total intensity (i.e., Stokes I) and linear polarizations (i.e., Stokes Q and U). This optimal resolution is better than that obtained from the widely used Cotton–Schwab CLEAN algorithm or from using ℓ {sub 1} or TV regularizations alone. Furthermore, we find that ℓ {sub 1}+TV regularization can achieve much better image fidelity in linear polarization than other techniques over a wide range of spatial scales, not only in the superresolution regime, but also on scales larger than the diffraction limit. Our results clearly demonstrate that sparse reconstruction is a useful choice for high-fidelity full-polarimetric interferometric imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-PRECISION ASTROMETRIC MILLIMETER VERY LONG BASELINE INTERFEROMETRY USING A NEW METHOD FOR MULTI-FREQUENCY CALIBRATION

In this paper we describe a new approach for millimeter Very Long Baseline Interferometry (mm-VLBI) calibration that provides bona-fide astrometric alignment of the millimeter-wavelength images from a single source, for the measurement of frequency-dependent effects, such as “core-shifts” near the black hole of active galactic nucleus jets. We achieve our astrometric alignment by solving first for the ionospheric (dispersive) contributions using wide-band centimeter-wavelength observations. Second, we solve for the tropospheric (non-dispersive) contributions by using fast frequency-switching at the target millimeter-wavelengths. These solutions can be scaled and transferred from low frequency to the high frequency. To complete the calibration chain an additional step is required to remove a residual constant phase offset on each antenna. The result is an astrometric calibration and the measurement of the core-shift between 22 and 43 GHz for the jet in BL Lacertae to be −8 ± 5, 20 ± 6 μ as, in R.A. and decl., respectively. By comparison to conventional phase referencing at centimeter-wavelengths we are able to show that this core shift at millimeter-wavelengths is significantly less than what would be predicted by extrapolating the low-frequency result, which closely followed the predictions of the Blandford and Königl conical jet model. As such it would be the first demonstration for the association of the VLBI core with a recollimation shock, normally hidden at low frequencies due to the optical depth, which could be responsible for the γ -ray production in blazar jets.

79 ASTRONOMY AND ASTROPHYSICS↗