Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPELLERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Experimental and computational investigation of the NASA low-speed centrifugal compressor flow field

An experimental and computational investigation of the NASA Lewis Research Center's low-speed centrifugal compressor (LSCC) flow field was conducted using laser anemometry and Dawes' three-dimensional viscous code. The experimental configuration consisted of a backswept impeller followed by a vaneless diffuser. Measurements of the three-dimensional velocity field were acquired at several measurement planes through the compressor. The measurements describe both the throughflow and secondary velocity field along each measurement plane. In several cases the measurements provide details of the flow within the blade boundary layers. Insight into the complex flow physics within centrifugal compressors is provided by the computational fluid dynamics analysis (CFD), and assessment of the CFD predictions is provided by comparison with the measurements. Five-hole probe and hot-wire surveys at the inlet and exit to the impeller as well as surface flow visualization along the impeller blade surfaces provided independent confirmation of the laser measurement technique. The results clearly document the development of the throughflow velocity wake that is characteristic of unshrouded centrifugal compressors.

Hathaway, Michael D.↗

Pump CFD code validation tests

Pump CFD code validation tests were accomplished by obtaining nonintrusive flow characteristic data at key locations in generic current liquid rocket engine turbopump configurations. Data were obtained with a laser two-focus (L2F) velocimeter at scaled design flow. Three components were surveyed: a 1970's-designed impeller, a 1990's-designed impeller, and a four-bladed unshrouded inducer. Two-dimensional velocities were measured upstream and downstream of the two impellers. Three-dimensional velocities were measured upstream, downstream, and within the blade row of the unshrouded inducer.

Brozowski, L. A.↗

Rotary blood pump

A rotary blood pump is presented. The pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial, and radial clearances of the blades associated with the flow straightener, inducer portion, impeller portion, and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with crosslinked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

Bozeman, Richard J.↗

Design of a Bearingless Blood Pump

In the field of open heart surgery, centrifugal blood pumps have major advantages over roller pumps. The main drawbacks to centrifugal pumps are however problems with the bearings and with the sealing of the rotor shaft. In this paper we present a concept for a simple, compact and cost effective solution for a blood pump with a totally magnetically suspended impeller. It is based on the new technology of the 'Bearingless Motor' and is therefore called the 'Bearingless Blood Pump.' A single bearingless slice motor is at the same time a motor and a bearing system and is able to stabilize the six degrees of freedom of the pump impeller in a very simple way. Three degrees of freedom are stabilized actively (the rotation and the radial displacement of the motor slice). The axial and the angular displacement are stabilized passively. The pump itself (without the motor-stator and the control electronics) is built very simply. It consists of two parts only: the impeller with the integrated machine rotor and the housing. So the part which gets in contact with blood and has therefore to be disposable, is cheap. Fabricated in quantities, it will cost less than $10 and will therefore be affordable for the use in a heart-lung-machine.

Barletta, Natale↗

Rotary Blood Pump

A rotary blood pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial and radial clearances of blades associated with the flow straightener, inducer portion, impeller portion and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with cross-linked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

Bozeman, Richard J., Jr.↗

Method for Reducing Pumping Damage to Blood

Methods are provided for minimizing damage to blood in a blood pump wherein the blood pump comprises a plurality of pump components that may affect blood damage such as clearance between pump blades and housing, number of impeller blades, rounded or flat blade edges, variations in entrance angles of blades, impeller length, and the like. The process comprises selecting a plurality of pump components believed to affect blood damage such as those listed herein before. Construction variations for each of the plurality of pump components are then selected. The pump components and variations are preferably listed in a matrix for easy visual comparison of test results. Blood is circulated through a pump configuration to test each variation of each pump component. After each test, total blood damage is determined for the blood pump. Preferably each pump component variation is tested at least three times to provide statistical results and check consistency of results. The least hemolytic variation for each pump component is preferably selected as an optimized component. If no statistical difference as to blood damage is produced for a variation of a pump component, then the variation that provides preferred hydrodynamic performance is selected. To compare the variation of pump components such as impeller and stator blade geometries, the preferred embodiment of the invention uses a stereolithography technique for realizing complex shapes within a short time period.

Bozeman, Richard J., Jr.↗

Axial Pump

A rotary blood pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial and radial clearances of blades associated with the flow straightener, inducer portion, impeller portion and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with cross-linked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

Bozeman, Richard J., Jr.↗

NRA8-21 Cycle 2 RBCC Turbopump Risk Reduction

This project was composed of three sub-tasks. The objective of the first task was to use the CFD code INS3D to generate both on- and off-design predictions for the consortium optimized impeller flowfield. The results of the flow simulations are given in the first section. The objective of the second task was to construct a turbomachinery testing database comprised of measurements made on several different impellers, an inducer and a diffuser. The data was in the form of static pressure measurements as well as laser velocimeter measurements of velocities and flow angles within the stated components. Several databases with this information were created for these components. The third subtask objective was two-fold: first, to validate the Enigma CFD code for pump diffuser analysis, and secondly, to perform steady and unsteady analyses on some wide flow range diffuser concepts using Enigma. The code was validated using the consortium optimized impeller database and then applied to two different concepts for wide flow diffusers.

Ferguson, Thomas V.↗

Performance of J33-A-21 and J33-A-23 Turbojet-Engine Compressors with Water Injection

As part of the performance investigation of compressors for the J33 turbojet engine, the A-21 model and the A-23 model with a 17- and a 34-blade impeller were operated with water injection at their respective design equivalent speeds of 11,500 and 11,750 rpm. Inlet conditions of pressure of 14 inches of mercury absolute and of ambient temperature correspond to those of the investigation of these models without water injection. The water-air ratio by weight ranged from 0.05 to 0.06. By the use of water injection, the peak pressure ratio of the A-21 compressor and the A-23 compressor with a 34-blade impeller increased approximately 0.38, whereas that of the A-23 compressor with a 17-blade impeller increased only 0.14. The decrease in maximum efficiency for the three compressors ranged from 0.12 to 0.14. The highest increase in maximum equivalent weight flow of air plus weight flow of water was 10.90 pounds per second obtained with the A-21 compressor. The increase in air weight flow alone was approximately 5.70 pounds per second for the A-21 compressor end the A-23, 17-blade compressor, which exceeded the increase of 3.15 pounds per second for the A-23; 34-blade compressor.

Beede, William L.↗

Experimental Investigation of a Model of a Two-Stage Turboblower

In the present paper an investigation is made of two stages of a multistage turboblower having a vaneless diffuser behind the impeller and guide vanes at the inlet to the nest stage. The method employed was that of investigating the performance of the successive elements of the blower (the impeller, vaneless diffuser, ets.) whereby the kinematics of the flow through the blower could be followed and the pressure at the different points computed. The character of the flow and the physical significance of the loss coefficients could thereby be determined so as to secure the best agreement of the computed with the actual performance of the blower. Since the tests were carried out for various delivery volumes, the dependence of the coefficients on a number of factors (angle of attack, velocities, etc.) could be obtained. The distribution of the losses that occur during the transformation of dynamic pressure at the impeller exit into static pressure could be found and likewise the range within which the friction coefficient varies in the vaneless diffuser. With the aid of factors having a certain physical significance, the centrifugal blower could be computed on the basis of a more or less schematical consideration of the phenomena occuring during the air flow through it, and the use of arbitrary factors and recourse to the geometrical similtude law thus avoided. The present investigation largely summarizes all the previous work af the CHI Blower Section on the different elements of a centrifugal blower. Some considerations on the analysis of model test data for application to full-scale are presented in the appendix.

Dovjik, s.↗

Reverse-Tangent Injection in a Centrifugal Compressor

Injection of working fluid into a centrifugal compressor in the reverse tangent direction has been invented as a way of preventing flow instabilities (stall and surge) or restoring stability when stall or surge has already commenced. The invention applies, in particular, to a centrifugal compressor, the diffuser of which contains vanes that divide the flow into channels oriented partly radially and partly tangentially. In reverse-tangent injection, a stream or jet of the working fluid (the fluid that is compressed) is injected into the vaneless annular region between the blades of the impeller and the vanes of the diffuser. As used here, "reverse" signifies that the injected flow opposes (and thereby reduces) the tangential component of the velocity of the impeller discharge. At the same time, the injected jet acts to increase the radial component of the velocity of the impeller discharge.

Skoch, Gary J.↗

PLSS 2.5 Fan Design and Development

NASA is building a high fidelity prototype of an advanced portable life support system (PLSS) as part of the Advanced Exploration Systems Program. This new PLSS, designated as PLSS 2.5, will advance component technologies and systems knowledge in order to inform a future flight program. The oxygen ventilation loop of its predecessor, PLSS 2.0, is driven by a centrifugal fan developed using specifications from over five years ago. PLSS technology and system parameters have matured to the point where the existing fan will not perform adequately for the new prototype. In addition, areas of potential improvement have been identified with the existing fan that could be addressed in a new design. As a result, a new fan was designed and tested for the PLSS 2.5. The PLSS 2.5 fan is a derivative of the one used in PLSS 2.0. It uses the same basic non-metallic can around the motor, but with a larger volute and impeller to meet the higher pressure drop requirements of the PLSS 2.5 loop. This allows it to operate at rotational speeds that are matched to rolling element bearings, and which create reasonably low impeller tip speeds. Development of the fan also considered a shrouded impeller design that allows larger clearances for greater oxygen safety and better performance.

Converse, David↗

Testing of Selective Laser Melting Turbomachinery Applicable to Exploration Upper Stage

This task is to design, fabricate, and spin test to failure a Ti6-4 hydrogen turbopump impeller that was built using the selective laser melting (SLM) fabrication process (fig. 1). The impeller is sized around upper stage engine requirements. In addition to the spin burst test, material testing will be performed on coupons that are built with the impeller.

Calvert, Marty↗

Electric Turbo Pump

NASA is working in junction with another company on the Electric Turbo Pump. Analysis of the impeller, including the blades, volute housing, and associated components, will take place in ANSYS. Contours of the deformed and stress were recorded to assess the parts. Campbell diagrams will be considered as mentioned to find the operating regions of the impeller and volute housing, more specifically what speed is ideal to ensure that the impeller does not begin to vibrate at a frequency that will break it. More than one material will be examined as per request by the designer to determine which material is more cost efficient, easy to machine, and can withstand the stress values that will be placed on it.

Steckler, Jessica↗

GT2024-139262: Development of a Computational Fluid Dynamics Model for a High-Speed Centrifugal Compressor

Computational fluid dynamics (CFD) has become widely used in the design and analysis of turbomachinery components such as centrifugal compressors. However, CFD is only a limited representation of experimental cases and struggles to model complex flows or lack model details to increase computation speed. The High Efficiency Centrifugal Compressor (HECC) was designed by United Technologies Research Center for NASA to investigate the difficulties behind improving centrifugal compressor technology and to provide an open case to the turbomachinery research community. The CFD technology seen in previous numerical models of the compressor have improved since then. In this study, a high-fidelity computational model for the vaneless configuration of HECC operating at its design point was developed and compared to an equivalent experimental case. This model incorporated GPU versions of mesh generation code WAND and solver code LEO from AeroDynamic Solutions, Inc. Blade sections extracted from the solid model formed the basis of the impeller mesh, while the remainder of the stage was modeled as ducts. Standard day aerodynamic conditions, design rotational speed, design mass flow rate, and inlet flow angles served as additional inputs. A mesh sensitivity study was performed prior to using the model for analysis. The accuracy of the model’s predictions of impeller and stage performance were assessed by comparing the total pressure ratio, total temperature rise ratio, and adiabatic efficiency to the corresponding parameters observed in the experimental case. Results showed a general overprediction of compressor performance by the model. Predictions were more accurate for the impeller performance compared to those for the full compressor stage. Spanwise analyses showed that the model tended to follow flow behavior patterns exhibited in the experiment. Beyond this study, this model was used to examine HECC aerodynamics and performance in research following thereafter.

centrifugal compressor↗

Microfluidic active mixing nozzle for three-dimensional printing of viscoelastic inks

A microfluidic printing nozzle for 3D printing may include a mixing chamber, a first inlet for connecting with a first ink source, the first inlet located at a first end of the mixing chamber, and a second inlet for connecting with a second ink source, the second inlet located at the first end of the mixing chamber. An outlet may be located at a second end of the mixing chamber, and a generally cylindrical impeller may be rotatably disposed in the mixing chamber between the first end and the second end. The cylindrical impeller may include an outer surface, and the outer surface of the impeller includes a groove, a protrusion, or both, to facilitate mixing of fluidic inks flowing from the first end to the second end of the mixing chamber.

47 OTHER INSTRUMENTATION↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/heccdata/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗