TH-A-BRF-08: Deformable Registration of MRI and CT Images for MRI-Guided Radiation Therapy

Purpose: To evaluate the quality of a commercially available MRI-CT image registration algorithm and then develop a method to improve the performance of this algorithm for MRI-guided prostate radiotherapy. Methods: Prostate contours were delineated on ten pairs of MRI and CT images using Eclipse. Each pair of MRI and CT images was registered with an intensity-based B-spline algorithm implemented in Velocity. A rectangular prism that contains the prostate volume was partitioned into a tetrahedral mesh which was aligned to the CT image. A finite element method (FEM) was developed on the mesh with the boundary constraints assigned from the Velocity generated displacement vector field (DVF). The resultant FEM displacements were used to adjust the Velocity DVF within the prism. Point correspondences between the CT and MR images identified within the prism could be used as additional boundary constraints to enforce the model deformation. The FEM deformation field is smooth in the interior of the prism, and equal to the Velocity displacements at the boundary of the prism. To evaluate the Velocity and FEM registration results, three criteria were used: prostate volume conservation and center consistence under contour mapping, and unbalanced energy of their deformation maps. Results: With the DVFs generated by the Velocity and FEM simulations, the prostate contours were warped from MRI to CT images. With the Velocity DVFs, the prostate volumes changed 10.2% on average, in contrast to 1.8% induced by the FEM DVFs. The average of the center deviations was 0.36 and 0.27 cm, and the unbalance energy was 2.65 and 0.38 mJ/cc3 for the Velocity and FEM registrations, respectively. Conclusion: The adaptive FEM method developed can be used to reduce the error of the MIbased registration algorithm implemented in Velocity in the prostate region, and consequently may help improve the quality of MRI-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

Purpose: Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET–CT misalignment. Methods: A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. Results: In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations also indicated that the magnitude of MBF errors resulting from motion in the superior/inferior and anterior/posterior directions was similar (up to 250%). Body motion effects were more detrimental for higher resolution PET imaging (2 vs 10 mm full-width at half-maximum), and for motion occurring during the mid-to-late time-frames. Motion correction of the reconstructed dynamic image series resulted in significant reduction in MBF errors, but did not account for the residual PET–CTAC misalignment artifacts. MBF bias was reduced further using global partial-volume correction, and using dynamic alignment of the PET projection data to the CT scan for accurate attenuation correction during image reconstruction. Conclusions: Patient body motion can produce MBF estimation errors up to 500%. To reduce these errors, new motion correction algorithms must be effective in identifying motion in the left/right direction, and in the mid-to-late time-frames, since these conditions produce the largest errors in MBF, particularly for high resolution PET imaging. Ideally, motion correction should be done before or during image reconstruction to eliminate PET-CTAC misalignment artifacts.

60 APPLIED LIFE SCIENCES↗

SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy

Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared to rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.

60 APPLIED LIFE SCIENCES↗

MusMorph, a database of standardized mouse morphology data for morphometric meta-analyses

Complex morphological traits are the product of many genes with transient or lasting developmental effects that interact in anatomical context. Mouse models are a key resource for disentangling such effects, because they offer myriad tools for manipulating the genome in a controlled environment. Unfortunately, phenotypic data are often obtained using laboratory-specific protocols, resulting in self-contained datasets that are difficult to relate to one another for larger scale analyses. To enable meta-analyses of morphological variation, particularly in the craniofacial complex and brain, we created MusMorph, a database of standardized mouse morphology data spanning numerous genotypes and developmental stages, including E10.5, E11.5, E14.5, E15.5, E18.5, and adulthood. To standardize data collection, we implemented an atlas-based phenotyping pipeline that combines techniques from image registration, deep learning, and morphometrics. Alongside stage-specific atlases, we provide aligned micro-computed tomography images, dense anatomical landmarks, and segmentations (if available) for each specimen (N = 10,056). Our workflow is open-source to encourage transparency and reproducible data collection.

59 BASIC BIOLOGICAL SCIENCES↗

Alignment and Bonding of Silicon Mirrors for High-Resolution Astronomical X-Ray Optics [10699-141]

Future large x-ray astronomy missions require large area and high resolution. The present consensus is to integrate thin, lightweight, segmented mirrors to form a compact but large telescope with high resolution (better than 1 sec). Key technologies: 1) Accurate mirror substrates: polishing high quality mono-crystalline silicon. 2) Stress-free reflective coating: stress-based distortion cancellation. 3) Precise alignment and integration: kinematic mounting and distortion-free bonding. Four-point alignment for quasi-cylindrically symmetric mirrors (segments) - 4-Point alignment: Pitch and yaw angles, image center (X, Y) are controlled by heights of the 4 mount points; Alignment Precision: better than 1 sec; Bonding error: approx. 0.1 micrometers (approx. 1 sec); Current single mirror pair x-ray tested: 3 sec (Half-Power Diameter). Integration into (meta) shell: Shell structure has rotationally defined axis; Interlocking mirrors means lightweight, mechanically strong telescope.

Chan, Kai-Wing↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

3D/3D registration of coronary CTA and biplane XA reconstructions for improved image guidance

Purpose: The authors aim to improve image guidance during percutaneous coronary interventions of chronic total occlusions (CTO) by providing information obtained from computed tomography angiography (CTA) to the cardiac interventionist. To this end, the authors investigate a method to register a 3D CTA model to biplane reconstructions. Methods: The authors developed a method for registering preoperative coronary CTA with intraoperative biplane x-ray angiography (XA) images via 3D models of the coronary arteries. The models are extracted from the CTA and biplane XA images, and are temporally aligned based on CTA reconstruction phase and XA ECG signals. Rigid spatial alignment is achieved with a robust probabilistic point set registration approach using Gaussian mixture models (GMMs). This approach is extended by including orientation in the Gaussian mixtures and by weighting bifurcation points. The method is evaluated on retrospectively acquired coronary CTA datasets of 23 CTO patients for which biplane XA images are available. Results: The Gaussian mixture model approach achieved a median registration accuracy of 1.7 mm. The extended GMM approach including orientation was not significantly different (P > 0.1) but did improve robustness with regards to the initialization of the 3D models. Conclusions: The authors demonstrated that the GMM approach can effectively be applied to register CTA to biplane XA images for the purpose of improving image guidance in percutaneous coronary interventions.

60 APPLIED LIFE SCIENCES↗

Measuring the Cryogenic Optical Alignment Between the Telescope Element and the Instruments Module of the James Webb Space Telescope

The alignment between the Aft Optical Subsystem (AOS) and the Integrated Science Instruments Module (ISIM) is non-adjustable in orbit, so the alignment must be carefully verified in a cryogenic vacuum environment prior to launch. Optical point source locations calibrated by optical metrology instruments are imaged through the AOS onto the Science Instruments to determine focal, lateral, and clock angle alignment. The pupil image of the AOS is overlaid onto the pupil image of the NIRCam to determine the tip and tilt alignment. In addition, an image from fiducial lights at the Primary Mirror checks the pupil alignment between the telescope entrance pupil, the telescope pupil mask, and the NIRCam aperture stop. The image positions are combined to determine the relative alignment between the Optical Telescope Element (OTE) and the ISIM in all six degrees of freedom with corresponding alignment uncertainties. Uncertainties in the position of focused images of the test sources and images from the pupils are derived from sensitivities of an optical model of the system and the Science Instrument sensing capability. Additional uncertainty in the pupil alignment measurement is due to uncertainty in the analytical removal of gravity effects that simulate the on-orbit alignment environment.

Whitman, Tony↗

An Image-Guided Study of Setup Reproducibility of Postmastectomy Breast Cancer Patients Treated With Inverse-Planned Intensity Modulated Radiation Therapy

Purpose: To calculate planning target volume (PTV) margins for chest wall and regional nodal targets using daily orthogonal kilovolt (kV) imaging and to study residual setup error after kV alignment using volumetric cone-beam computed tomography (CBCT). Methods and Materials: Twenty-one postmastectomy patients were treated with intensity modulated radiation therapy with 7-mm PTV margins. Population-based PTV margins were calculated from translational shifts after daily kV positioning and/or weekly CBCT data for each of 8 patients, whose surgical clips were used as surrogates for target volumes. Errors from kV and CBCT data were mathematically combined to generate PTV margins for 3 simulated alignment workflows: (1) skin marks alone; (2) weekly kV imaging; and (3) daily kV imaging. Results: The kV data from 613 treatment fractions indicated that a 7-mm uniform margin would account for 95% of daily shifts if patients were positioned using only skin marks. Total setup errors incorporating both kV and CBCT data were larger than those from kV alone, yielding PTV expansions of 7 mm anterior–posterior, 9 mm left–right, and 9 mm superior–inferior. Required PTV margins after weekly kV imaging were similar in magnitude as alignment to skin marks, but rotational adjustments of patients were required in 32% ± 17% of treatments. These rotations would have remained uncorrected without the use of daily kV imaging. Despite the use of daily kV imaging, CBCT data taken at the treatment position indicate that an anisotropic PTV margin of 6 mm anterior–posterior, 4 mm left–right, and 8 mm superior–inferior must be retained to account for residual errors. Conclusions: Cone-beam CT provides additional information on 3-dimensional reproducibility of treatment setup for chest wall targets. Three-dimensional data indicate that a uniform 7-mm PTV margin is insufficient in the absence of daily IGRT. Interfraction movement is greater than suggested by 2-dimensional imaging, thus a margin of at least 4 to 8 mm must be retained despite the use of daily IGRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates

We present an image postprocessing framework for Scanning Tunneling Microscope (STM) to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a “rubber band” model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA). The numerical results on measurement from copper(111) surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

47 OTHER INSTRUMENTATION↗

Investigating the Role of the Earth's Ionosphere in Space Weather: Modeling and Observations of High-Latitude Ionospheric Outflows

We will present what we believe to be the first reported observations of up- and downflows of topside ionospheric thermal plasmas from multiple near-simultaneous tracks through the high-latitude topside ionosphere. From several Southern polar passes, it has been possible to construct plots of field-aligned flows of 0+ observed by the Thermal Ion Dynamics Experiment(TIDE) on the POLAR spacecraft near 5000 km altitude together with vertical ion flow observations from one or more DMSP spacecraft near 800 km altitude. We also will present simultaneous observations of POLAR auroral LTVI images with field-aligned flows. We will further show new fluid-kinetic simulations of auroral ionospheric flows in the altitude range 120 km to several R-E as subjected to the synergistic auroral effects of soft electron precipitation, transverse wave-driven ion heating, and hot plasma-driven electric potentials.

Horwitz, J. L.↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗

In-situ observation of calcium chloride hexahydrate phase separation via neutron imaging

Inorganic salt hydrate offers a low-cost thermal energy storage solution with high energy density, but phase separation during thermal cycling poses a significant challenge, leading to irreversible performance degradation. In this research, neutron radiography was used to investigate phase separation in calcium chloride hexahydrate (CaCl₂·6H₂O, CCH) during thermal cycling to track its gradual accumulation into calcium chloride tetrahydrate (CaCl₂·4H₂O, CC4). Through in-situ visualization, phase separation and CC4 sedimentation were observed to occur during the cooling phase between 301.40 K and 304.80 K. CC4 accumulated linearly to 7.99 wt% after 10 thermal cycles. Crystallization and multi-cycle conversion models were developed to validate neutron imaging results of CC4 formation. The predicted CC4 content after 10 thermal cycles closely aligned with experimental observations. Neutron imaging offers a novel approach to investigate salt hydrate phase change materials (PCMs). It enables in-situ visualization of sub-hydrate (CC4) formation from original hydrate (CCH) in metastable phase change range (between 301.40 ± 0.66 K and 304.80 ± 0.60 K). Thereby, it provides a new insight of understanding the basis of phase separation mechanism and paves the way for future research of improving PCM thermal cycling performance.

Li, Yucen [The University of Tennessee, Knoxville]↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗

Non-contact rapid reader system for reflective particle tags

A reflective particle tag reader system includes a read head assembly having a camera, illuminators, and a rigid frame portion for supporting the camera and the illuminators. The illuminators illuminate a focal point located opposite the camera where a reflective particle tag is placed. A computer in data communication with the camera receives and store images of the reflective particle tag that are acquired by the camera. The computer is programmed to process video images and to quantify a positional alignment parameter and an angular alignment parameter of the reader with respect to the reflective particle tag. A rapid burst of image frames is obtained in response to the positional alignment and the angular alignment parameters being within a predetermined tolerance and identity of the reflective tag is established between a first image set and a second image set.

42 ENGINEERING↗

A multiple-plate, multiple-pinhole camera for X-ray gamma-ray imaging

Plates with identical patterns of precisely aligned pinholes constitute lens system which, when rotated about optical axis, produces continuous high resolution image of small energy X-ray or gamma ray source. Camera has applications in radiation treatment and nuclear medicine.

Hoover, R. B.↗