Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Hierarchical Local Electricity Market for a DER-rich Grid Edge

We report with increasing penetration of distributed energy resources (DER) in the distribution system, it is critical to design market structures that enable smooth integration of DERs. A hierarchical local electricity market (LEM) structure is proposed in this paper with a secondary market (SM) at the lower level representing secondary feeders and a primary market (PM) at the upper level, representing primary feeders, in order to effectively use DERs to increase grid efficiency and resilience. The lower level SM enforces budget, power balance, and flexibility constraints and accounts for costs related to consumers, such as their disutility, flexibility limits, and commitment reliability, while the upper level PM enforces grid physics constraints such as power balance and capacity limits, and also minimizes line losses. The hierarchical LEM is extensively evaluated using a modified IEEE-123 bus with high DER penetration, with each primary feeder consisting of at least three secondary feeders. Data from a GridLAB-D model is used to emulate realistic power injections and load profiles over the course of 24 hours. The performance of the LEM is illustrated by delineating the family of power-injection profiles across the primary and secondary feeders as well as corresponding local electricity tariffs that vary across the distribution grid. Through numerical simulations, the hierarchical LEM is shown to improve the efficiency of the market in terms of lowering overall costs, including both the distribution-level locational marginal prices (d-LMP) as well as retail tariffs paid by customers. Together, it represents an overall framework for a Distribution System Operator (DSO) who can provide the oversight for the entire LEM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Correlation study of finite element analysis

A study was conducted to investigate and prove the correlation between the NASTRAN predicted stresses and those measured on an actual structure. NASTRAN is a general purpose digital computer program for the analysis of large complex structures. A real airframe, which had logged several thousand hours flying time, was obtained, instrumented, and loaded to obtain the measured strains.

Long, C. A.↗

The useful potential of using existing data to uniquely identify predictable wind events and regimes, part 1

Correlations between standard meteorological data and wind power generation potential were developed. Combined with appropriate wind forecasts, these correlations can be useful to load dispatchers to supplement conventional energy sources. Hourly wind data were analyzed for four sites, each exhibiting a unique physiography. These sites are Amarillo, Texas; Ludington, Michigan; Montauk Point, New York; and San Gorgonio, California. Synoptic weather maps and tables are presented to illustrate various wind 'regimes' at these sites.

Trettel, D. W.↗

Evaluation of a high-torque backlash-free roller actuator

The results are presented of a test program that evaluated the stiffness, accuracy, torque ripple, frictional losses, and torque holding capability of a 16:1 ratio, 430 N-m (320 ft-lb) planetary roller drive for a potential space vehicle actuator application. The drive's planet roller supporting structure and bearings were found to be the largest contributors to overall drive compliance, accounting for more than half the total. In comparison, the traction roller contacts themselves contributed only 9 percent of the drive's compliance based on an experimentally verified stiffnesss model. Torque ripple tests showed the drive to be extremely smooth, actually providing some damping of input torsional oscillations. The drive also demonstrated the ability to hold static torque with drifts of 7 arc sec or less over a 24-hour period at 35 percent of full load.

Steinetz, Bruce M.↗

Summary and recommendations for initial exercise prescription

The recommendations summarized herein constitute a basis on which an initial exercise prescription can be formulated. It is noteworthy that any exercise program designed currently would be an approximation. Examination of the existing space-flight data reveals a scarcity of in-flight data on which to rigorously design an exercise program. The relevant experience within the U.S. space program (with regard to long-duration space flight) is limited to the Skylab Program. Lessons learned from Skylab are relevant to the design of a Space Station exercise program, especially with regard to the total length of exercise time required, cardiovascular (CV) deconditioning/reconditioning, and bone loss. Certain observations of the U.S.S.R. exercise activities can also contribute to the formulation of an exercise prescription of Space Station. Reportedly, the U.S.S.R. uses both a bicycle ergometer and a treadmill device on long-duration missions with some degree of success. Using the third crew of Salyut 6, which was a 175-day stay, as a representative mission, the typical time dedicated to exercise varies from 2 to 3 hours per day. In addition, the cosmonauts wear an elasticized suit, called a penquin suit, for time periods ranging from 12 to 16 hours per day. This device provides a load across the axial skeleton against which the wearer must exert himself. Despite these extensive countermeasures, the effects of adaptation are not totally prevented.

Stewart, Donald F.↗

SPILC: An expert student advisor

The Lamar University Computer Science Department serves about 350 undergraduate C.S. majors, and 70 graduate majors. B.S. degrees are offered in Computer Science and Computer and Information Science, and an M.S. degree is offered in Computer Science. In addition, the Computer Science Department plays a strong service role, offering approximately sixteen service course sections per long semester. The department has eight regular full-time faculty members, including the Department Chairman and the Undergraduate Advisor, and from three to seven part-time faculty members. Due to the small number of regular faculty members and the resulting very heavy teaching loads, undergraduate advising has become a difficult problem for the department. There is a one week early registration period and a three-day regular registration period once each semester. The Undergraduate Advisor's regular teaching load of two classes, 6 - 8 semester hours, per semester, together with the large number of majors and small number of regular faculty, cause long queues and short tempers during these advising periods. The situation is aggravated by the fact that entering freshmen are rarely accompanied by adequate documentation containing the facts necessary for proper counselling. There has been no good method of obtaining necessary facts and documenting both the information provided by the student and the resulting advice offered by the counsellors.

Read, D. R.↗

SiC/SiC Composites for 1200 C and Above

The successful replacement of metal alloys by ceramic matrix composites (CMC) in high-temperature engine components will require the development of constituent materials and processes that can provide CMC systems with enhanced thermal capability along with the key thermostructural properties required for long-term component service. This chapter presents information concerning processes and properties for five silicon carbide (SiC) fiber-reinforced SiC matrix composite systems recently developed by NASA that can operate under mechanical loading and oxidizing conditions for hundreds of hours at 1204, 1315, and 1427 C, temperatures well above current metal capability. This advanced capability stems in large part from specific NASA-developed processes that significantly improve the creep-rupture and environmental resistance of the SiC fiber as well as the thermal conductivity, creep resistance, and intrinsic thermal stability of the SiC matrices.

DiCarlo, J. A.↗

Microstructural Optimization of High Temperature SiC/SiC Composites

Advanced materials and process approaches are described that have allowed NASA to develop five state-of-the-art silicon carbide (SiC) fiber-reinforced hybrid-SiC matrix composite systems that can operate under mechanical loading and oxidizing conditions for hundreds of hours at upper use temperatures from 1200 to 1450 C. Key data are presented that demonstrate the ability of these materials to meet the first-level property requirements for hot-section components in advanced gas turbine engines.

DiCarlo, James A.↗

Advanced Constituents and Processes for Ceramic Composite Engine Components

The successful replacement of metal alloys by ceramic matrix composites (CMC) in hot-section engine components will depend strongly on optimizing the processes and properties of the CMC microstructural constituents so that they can synergistically provide the total CMC system with improved temperature capability and with the key properties required by the components for long-term structural service. This presentation provides the results of recent activities at NASA aimed at developing advanced silicon carbide (Sic) fiber-reinforced hybrid Sic matrix composite systems that can operate under mechanical loading and oxidizing conditions for hundreds of hours at 2400 and 2600 F, temperatures well above current metal capability. These SiC/SiC composite systems are lightweight (-30% metal density) and, in comparison to monolithic ceramics and carbon fiber-reinforced ceramic composites, are able to reliably retain their structural properties for long times under aggressive engine environments. It is shown that the improved temperature capability of the SiC/SiC systems is related first to the NASA development of the Sylramic-iBN Sic fiber, which displays high thermal stability, creep resistance, rupture resistance, and thermal conductivity, and possesses an in-situ grown BN surface layer for added environmental durability. This fiber is simply derived from Sylramic Sic fiber type that is currently produced at ATK COI Ceramics. Further capability is then derived by using chemical vapor infiltration (CVI) to form the initial portion of the hybrid Sic matrix. Because of its high creep resistance and thermal conductivity, the CVI Sic matrix is a required base constituent for all the high temperature SiC/SiC systems. By subsequently thermo- mechanical-treating the CMC preform, which consists of the S ylramic-iBN fibers and CVI Sic matrix, process-related defects in the matrix are removed, further improving matrix and CMC creep resistance and conductivity.

Yun, H. M.↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

A Study of Cost-Saving Potential of Load Flexibility Measures in Grid-Interactive Multifamily Buildings

With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.

building energy modeling↗

Investigating Commercial Off-The-Shelf (COTS) Glovebox and Support Components Compared to Custom Curatorial Laboratories

There is a need envisioned to investigate the application of commercial off-the-shelf (COTS) systems as tools that could be used within commercial preliminary curation as the expected space economy is supported and begins to take flight. NASA is involved with supporting and developing the space economy [1] and therefore it’s feasible that at some point, a commercial space company would bring back materials and either store initially, or permanently, within COTS equipment as a stand-in for custom curation laboratories. While utilizing opportunities to explore this capability at NASA-Johnson Space Center (JSC) during the establishment of other laboratories [2] it was realized that cleanliness and/or other properties could be evaluated for these COTS systems during their installation in advanced research facilities that are not ISO-class rated clean rooms. Several aspects of a COTS-Curation system were explored including various gloves for curation manipulation within a negative pressure glovebox (Fig.1), Balazs organic and inorganic contaminant levels testing prior to glovebox ever being used, mode swapping comparison of recirculation vs. single pass, constant monitoring of oxygen (O2) and moisture (H2O) levels in various conditions, etc. To acquire inorganic and organic compound loads inside the glovebox, Balazs wafer testing and gas sampling were implemented. These are standardized analytical tests provided by Balazs™ NanoAnalysis, a division of Air Liquide USA. Deployment of 8-inch silicon wafer witness plates for 24-hours in an undisturbed environment capture the organic compound load and inorganic trace metal contents which can be obtained by Vapor Phase Decomposition Inductively Coupled Plasma Mass Spectrometry (VPD ICP-MS). Balazs gas sample analysis was also performed for better measurements of volatile organic compounds (VOC) in glovebox air analyzed by Thermal Desorption Gas Chromatography Mass Spectrometry (TD GC-MS). These analytical testings were carried out in a controlled ultra high pure (UHP) gaseous nitrogen (N2)-purged environment where oxygen and moisture contents were continuously monitored at certain temperature and pressure. The preliminary outcomes of these testings are promising. The COTS systems appear to maintain the steady-state controlled environment for days, if not weeks, with uninterrupted gaseous N2-supply which was operated from a standard medium pressure LN2 250L 230L dewar, exchanged as needed. The outgassing load can be maintained by selecting the glove materials that have the least outgassing and particle shedding performances. Further experiments will be considered to validate the preliminary findings. While this project is exploratory, it is not intended as an endorsement by NASA Curation for approved materials or usage for advanced curatorial activities. NASA does not endorse nor promote any one particular product or company. References: [1] McCubbin F. M. et al. (2019) Space Science Reviews 215:A48. [2] Lewis, E.K. et. al (2024) LPSC LV, Abstract #2457.

Curation↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

New non-geosynchronous orbits for communications satellites to off-load daily peaks in geostationary traffic

The potential for satellites in two orbits, the sun-synchronous 12-hour equatorial orbit (STET) and the apogee at constant time-of-day equatorial orbit (ACE), to off-load peaks in the CONUS geostationary communications traffic is discussed. These orbits are found to require maneuvers of smaller magnitudes for insertion than geostationary orbits. Advantages of the ACE orbit over the STET orbit are discussed, including larger satellite mass capability for a given launch vehicle, lower slant ranges, and larger angular separation from the geostationary arc for a nonequatorial ground observer.

Turner, A. E.↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Omics of Stem Cell Mediated Regeneration: A Pilot Single Cell RNA-Seq Study of Mechanotransduction

Mechanical forces are potent modulators of stem cell based tissue regenerative mechanisms, inducing cell fate decisions and tissue specific commitment. A unique platform for investigating mechanotransduction is spaceflight, where microgravity and altered fluid mechanics provide a loading-null experimental condition. Seminal investigations of regenerative capacity in a wholly regenerative species, the newt model, and in a variety of totipotent and adult stem cell populations have demonstrated the detrimental effects of unloading on maintenance of stem cell based regeneration. Of particular interest is the observation that unloading interferes with the transition of stem cell pools from proliferative state to differentiation commitment. In this work we sought to test the hypothesis that gravity mechanotransduction regulates stem cell tissue regenerative processes by modulating stem cell proliferation and differentiation fates at specific cell cycle stages. To do this, clonally-derived ESCs were plated on a collagen matrix and expanded for 36 hours before re-plating on a non-adherent culture dish in the absence of leukemia inhibitory factor (LIF) to form spheroid aggregate EBs. After formation, the EBs were transferred to a collagen matrix coated culture dishes and given 4 days to allow implantation and outgrowth. In parallel, totipotent ESCs were plated 24 hours before mechanical stimulation on collagen matrix culture dishes in the presence of LIF to maintain totipotency and serve as un-differentiation committed controls. The EBs and ESCs were then subjected to either a 60 minute pulse of gravity (static loading) or 60 minutes of cyclic stretch (dynamic loading) mechanotransduction. Six hours post-stimulation, we used a 10X Genomics Single Cell controller to generate bar-coded single cell Illumina libraries and sequenced expressomes for 5,000 static loaded cells, representative of a change in gravity mechanotransduction, 5,000 dynamic loaded cells, representative of tissue loading associate with physiologic function, and 5,000 unstimulated 1g control cells. The comparison of these 3 libraries by cluster assignment based on like gene expression patterns show substantial alteration in cluster geometry due to mechanical loading. Specifically the mechanically loaded EB outgrowth cells to retain potency markers (PAX6, SOX2, CD34) and suppress early commitment markers (Dhh, VCAN, Igf1). Whereas the EBs cultured under the non-stimulated conditions display clear departure from the ESC expressome with lineage commitment markers upregulated and several tissue specific markers being expressed (BMP "early musculoskeletal development, Mesp1" early cardiovascular cell lineage). These markers are not seen in the mechano-stimulated cultures or the totipotent ESC cultures. Comparison of like clusters between our experimental conditions revealed an array of regenerative and stem cell genes are significantly mechano-regulated. Of particular importance CDKN1a/p21, a gene shown by previous investigation of our research team to be significantly upregulated in unloading, was suppressed in the static and dynamic loaded EBS. In addition to CDKN1a/p21 many genes related to cell cycle and transitory differentiation markers had elevated expression in the mechano-stimulated EBs, but surprisingly these trends were not observed in the ESC cultures. This study is the first of its kind investigating for mechano-signaling and mechano-regulated pathways, and has alre

Single cell RNA-sequecing↗

Electric Load Planning Tool (ELPT) v0.9

The Electric Load Planning Tool (ELPT) helps facilities understand the economic and environmental impacts of their electricity consumption. Using a user-provided Excel input, ELPT analyzes electricity use, costs, and grid CO2e emissions to identify savings opportunities through load management strategies such as load shifting, shedding, and planning. It accounts for Time-of-Use (TOU) tariffs and hourly emissions factors, varying by location and time of day. Users input details about their facility's load profile, location, year of analysis, and electricity billing tariff to receive customized insights. The tool provides visual representations of cost and GHG impacts, helping users understand the benefits of adjusting electricity usage to align with periods of cheaper and cleaner electricity, thereby achieving cost savings and reducing Scope 2 CO2e emissions

Karki, Unique [Lawrence Berkeley National Laborato↗