Design and testing of high-performance mini-channel graphite heat exchangers in thermoelectric energy recovery systems

Recent national energy usage studies by Lawrence Livermore National Laboratory in 2015 [1] show that there is approximately 59 Quads (1015 Btu’s) of waste thermal energy throughout various industrial, residential, power generation, and transportation sectors of the U.S. economy. Thermoelectric energy recovery is one important technology for recovering this waste thermal energy in high-temperature industrial, transportation and military energy systems. Thermoelectric generator (TEG) systems in these applications require high performance hot-side and cold-side heat exchangers to provide the critical temperature differential and transfer the required thermal energy. High performance hot-side heat exchangers in these systems are often metal-based due to requirements for high-temperature operation, strength at temperature, corrosion resistance, and chemical stability. However, the generally selected metal-based hot-side heat exchangers (i.e., Inconels, Stainless Steels) suffer from low thermal conductivity, high thermal expansion, and high density, which degrades their thermal performance, leads to high thermal-expansion-driven stresses, and creates relatively high mass/high volume (i.e., low power density) TEG systems that are then difficult to fabricate and integrate into viable energy recovery systems. This paper describes the design and testing of a new, high-temperature minichannel graphite heat exchanger designed for operation up to 500C that is a critical element of a high-power-density TEG power system for aircraft energy recovery. This high-performance graphite heat exchanger represents a new state-of-the-art standard in high-temperature heat exchangers for TEG systems, which provides higher thermal transport, less thermal expansion at operation, lower system level stresses on TE components, and a lighter weight TEG system. This new heat exchanger creates a new design paradigm in TEG system design for terrestrial energy recovery and potential NASA technology infusion into terrestrial energy system applications. This paper will present and discuss the key heat transfer, pressure drop, pumping power analyses and design tradeoffs that created this unique design. Heat transfer and pressure drop modeling was performed with both empirical models based on known heat transfer and friction factor correlations and COMSOL thermal/fluid dynamic modeling of the graphite heat exchanger structure. We will also discuss resulting thermal transport and heat fluxes predicted at the TEG interface level. Heat exchanger performance testing was performed under simulated operating conditions and correlation with test data at the anticipated operating temperature conditions will be presented and discussed.

Shevade, Abhijit↗

Heat Transfer and Flow on the Squealer Tip of a Gas Turbine Blade

Experimental investigations are performed to measure the detailed heat transfer coefficient and static pressure distributions on the squealer tip of a gas turbine blade in a five-bladed stationary linear cascade. The blade is a 2-dimensional model of a modem first stage gas turbine rotor blade with a blade tip profile of a GE-E(sup 3) aircraft gas turbine engine rotor blade. A squealer (recessed) tip with a 3.77% recess is considered here. The data on the squealer tip are also compared with a flat tip case. All measurements are made at three different tip gap clearances of about 1%, 1.5%, and 2.5% of the blade span. Two different turbulence intensities of 6.1% and 9.7% at the cascade inlet are also considered for heat transfer measurements. Static pressure measurements are made in the mid-span and near-tip regions, as well as on the shroud surface opposite to the blade tip surface. The flow condition in the test cascade corresponds to an overall pressure ratio of 1.32 and an exit Reynolds number based on the axial chord of 1.1 x 10(exp 6). A transient liquid crystal technique is used to measure the heat transfer coefficients. Results show that the heat transfer coefficient on the cavity surface and rim increases with an increase in tip clearance. 'Me heat transfer coefficient on the rim is higher than the cavity surface. The cavity surface has a higher heat transfer coefficient near the leading edge region than the trailing edge region. The heat transfer coefficient on the pressure side rim and trailing edge region is higher at a higher turbulence intensity level of 9.7% over 6.1 % case. However, no significant difference in local heat transfer coefficient is observed inside the cavity and the suction side rim for the two turbulence intensities. The squealer tip blade provides a lower overall heat transfer coefficient when compared to the flat tip blade.

Azad, Gm S.↗

Turbine heat transfer

Improved turbine durability and performance and reduced development cost will all result from impoved methods of predicting turbine metal temperatures. Better metal temperature prediction methods require improvements in the methods of predicting the hot gas flow over the turbine airfoils and the cooling air flow inside the airfoil and in the methods of predicting the heat transfer rates on both the hot gas side and coolant side of the airfoil. The overall HOST Turbine Heat Transfer effort is directed at improving all four of these areas of concern.

Rohde, J. E.↗

Aerodynamics and heat transfer investigations on a high Reynolds number turbine cascade

The results of aerodynamic and heat transfer experimental investigations performed in a high Reynolds number turbine cascade test facility are analyzed. The experimental facility simulates the high Reynolds number flow conditions similar to those encountered in the Space Shuttle Main Engine. In order to determine the influence of Reynolds number on aerodynamic and thermal behavior of the blades, heat transfer coefficients were measured at various Reynolds numbers using liquid crystal temperature measurement technique. Potential flow calculation methods were used to predict the cascade pressure distributions. Boundary layer and heat transfer calculation methods were used with these pressure distributions to verify the experimental results.

Schobeiri, Taher↗

Aerodynamics and heat transfer investigations on a high Reynolds number turbine cascade

The results of aerodynamic and heat transfer experimental investigations performed in a high Reynolds number turbine cascade test facility are analyzed. The experimental facility simulates the high Reynolds number flow conditions similar to those encountered in the Space Shuttle Main Engine. In order to determine the influence of Reynolds number on aerodynamic and thermal behavior of the blades, heat transfer coefficients were measured at various Reynolds numbers using liquid crystal temperature measurement technique. Potential flow calculation methods were used to predict the cascade pressure distributions. Boundary layer and heat transfer calculation methods were used with these pressure distributions to verify the experimental results.

Schobeiri, Taher↗

Advanced X ray Astrophysics Facility-Imaging (AXAF-I) thermal analyses using Integrated Thermal Analysis System (ITAS) program

The complex geometry and stringent thermal requirements associated with the Advanced X-ray Astrophysics Facility - Imaging (AXAF-I) necessitate a detailed and accurate thermal analysis of the proposed system. A brief description of said geometry and thermal requirements is included. Among the tools considered for the aforementioned analysis is a PC-compatible version of the Integrated Thermal Analysis System (ITAS). Several bench-mark studies were performed to evaluate the capabilities of ITAS and to compare the corresponding results with those obtained using TRASYS and SINDA. Comparative studies were conducted for a typical Space Station module. Four models were developed using various combinations of the available software packages (i.e. ITAS, SINDA, and TRASYS). Orbital heating and heat transfer calculations were performed to determine the temperature distributions along the surfaces of this module. A comparison of the temperature distributions obtained for each of the four cases is presented. Results of this investigation were used to verify the different ITAS modules including those used for model generation, steady state and transient orbital heating analyses, radiative and convective heat flow analyses, and SINDA/TRASYS model translation. The results suggest that ITAS is well suited to subsequent analyses of the AXAF-I.

Ghaffarian, Benny↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Bubble Dynamics, Two-Phase Flow, and Boiling Heat Transfer in Microgravity

This report contains two independent sections. Part one is titled "Terrestrial and Microgravity Pool Boiling Heat Transfer and Critical heat flux phenomenon in an acoustic standing wave." Terrestrial and microgravity pool boiling heat transfer experiments were performed in the presence of a standing acoustic wave from a platinum wire resistance heater using degassed FC-72 Fluorinert liquid. The sound wave was created by driving a half wavelength resonator at a frequency of 10.15 kHz. Microgravity conditions were created using the 2.1 second drop tower on the campus of Washington State University. Burnout of the heater wire, often encountered with heat flux controlled systems, was avoided by using a constant temperature controller to regulate the heater wire temperature. The amplitude of the acoustic standing wave was increased from 28 kPa to over 70 kPa and these pressure measurements were made using a hydrophone fabricated with a small piezoelectric ceramic. Cavitation incurred during experiments at higher acoustic amplitudes contributed to the vapor bubble dynamics and heat transfer. The heater wire was positioned at three different locations within the acoustic field: the acoustic node, antinode, and halfway between these locations. Complete boiling curves are presented to show how the applied acoustic field enhanced boiling heat transfer and increased critical heat flux in microgravity and terrestrial environments. Video images provide information on the interaction between the vapor bubbles and the acoustic field. Part two is titled, "Design and qualification of a microscale heater array for use in boiling heat transfer." This part is summarized herein. Boiling heat transfer is an efficient means of heat transfer because a large amount of heat can be removed from a surface using a relatively small temperature difference between the surface and the bulk liquid. However, the mechanisms that govern boiling heat transfer are not well understood. Measurements of wall temperature and heat flux near the wall would add to the database of knowledge which is necessary to understand the mechanisms of nucleate boiling. A heater array has been developed which contains 96 heater elements within a 2.5 mm square area. The temperature of each heater element is held constant by an electronic control system similar to a hot-wire anemometer. The voltage that is being applied to each heater element can be measured and digitized using a high-speed Analog to Digital (A/D) converter, and this digital information can be compiled into a series of heat-flux maps. Information for up to 10,000 heat flux maps can be obtained each second. The heater control system, the A/D system and the heater array construction are described in detail. Results are presented which show that this is an effective method of measuring the local heat flux during nucleate and transition boiling. Heat flux maps are obtained for pool boiling in FC-72 on a horizontal surface. Local heat flux variations are shown to be three to six times larger than variations in the spatially averaged heat flux.

Chung, Jacob N.↗

Natural melting within a spherical shell

Fundamental heat transfer experiments were performed on the melting of a phase change medium in a spherical shell. Free expansion of the medium into a void space within the sphere was permitted. A step function temperature jump on the outer shell wall was imposed and the timewise evolution of the melting process and the position of the solid-liquid interface was photographically recorded. Numerical integration of the interface position data yielded information about the melted mass and the energy of melting. It was found that the rate of melting and the heat transfer were significantly affected by the movement of the solid medium to the base of the sphere due to gravity. The energy transfer associated with melting was substantially higher than that predicted by the conduction model. Furthermore, the radio of the measured values of sensible energy in the liquid melt to the energy of melting were nearly proportional to the Stefan number. The experimental results are in agreement with a theory set forth in an earlier paper.

Bahrami, Parviz A.↗

Solar dynamic modules for Space Station Freedom: The relationship between fine-pointing control and thermal loading of the aperture plate

Dynamic simulations of Space Station Freedom (SSF) configured with solar dynamic (SD) power modules were performed. The structure was subjected to Space Shuttle docking disturbances, while being controlled with a 'natural' vibration and tracking control approach. Three control cases were investigated for the purpose of investigating the relationship between actuator effort, SD pointing, and thermal loading on the receiver aperture plate. Transient, one-dimensional heat transfer analyses were performed to conservatively predict temperatures of the multi-layered receiver aperture plate assembly and thermal stresses in its shield layer. Results indicate that the proposed aperture plate is tolerant of concentrated flux impingement during short-lived structural disturbances. Pointing requirements may be loosened and the requirement control torques lessened from that previously specified. Downsizing and simplifying the joint drive system should result in a considerable savings mass.

Quinn, Roger D.↗

Optimal Design of Functionally Graded Metallic Foam Insulations

The focus of our work has been on developing an insight into the physics that govern the optimum design of thermal insulation for use in thermal protection systems of launch vehicle. Of particular interest was to obtain optimality criteria for designing foam insulations that have density (or porosity) distributions through the thickness for optimum thermal performance. We investigate the optimum design of functionally graded thermal insulation for steady state heat transfer through the foam. We showed that the heat transfer in the foam has competing modes, of radiation and conduction. The problem assumed a fixed inside temperature of 400 K and varied the aerodynamic surface heating on the outside surface from 0.2 to 1.0 MW/sq m. The thermal insulation develops a high temperature gradient through the thickness. Investigation of the model developed for heat conduction in foams showed that at high temperatures (as on outside wall) intracellular radiation dominates the heat transfer in the foam. Minimizing radiation requires reducing the pore size, which increases the density of the foam. At low temperatures (as on the inside wall), intracellular conduction (of the metal and air) dominates the heat transfer. Minimizing conduction requires increasing the pore size. This indicated that for every temperature there was an optimum value of density that minimized the heat transfer coefficient. Two optimization studies were performed. One was to minimize the heat transmitted though a fixed thickness insulation by varying density profiles. The second was to obtain the minimum mass insulation for specified thickness. Analytical optimality criteria were derived for the cases considered. The optimality condition for minimum heat transfer required that at each temperature we find the density that minimizes the heat transfer coefficient. Once a relationship between the optimum heat transfer coefficient and the temperature was found, the design problem reduced to the solution of a simple nonlinear differential equation. Preliminary results of this work were presented at the American Society of Composites meeting, and the final version was submitted for publication in the AIAA Journal. In addition to minimizing the transmitted heat, we investigated the optimum design for minimum weight given an acceptable level of heat transmission through the insulation. The optimality criterion developed was different from that obtained for minimizing beat transfer coefficient. For minimum mass design, we had to find for a given temperature the optimum density, which minimized the logarithmic derivative of the insulation thermal conductivity with respect to its density. The logarithmic derivative is defined as the ratio of relative change in the dependent response (thermal conductivity) to the relative change in the independent variable (density). The results have been documented as a conference paper that will be presented at the upcoming AIAA.

Haftka, Raphael T.↗

Predicting Turbulent Convective Heat Transfer in Fully Developed Duct Flows

The performance of an explicit algebraic stress model (EASM) is assessed in predicting the turbulent flow and forced heat transfer in both straight and wavy ducts, with rectangular, trapezoidal and triangular cross-sections, under fully developed conditions. A comparison of secondary flow patterns. including velocity vectors and velocity and temperature contours, are shown in order to study the effect of waviness on flow dynamics, and comparisons between the hydraulic parameters. Fanning friction factor and Nusselt number, are also presented. In all cases. isothermal conditions are imposed on the duct walls, and the turbulent heat fluxes are modeled using gradient-diffusion type models. The formulation is valid for Reynolds numbers up to 10(exp 5) and this minimizes the need for wall functions that have been used with mixed success in previous studies of complex duct flows. In addition, the present formulation imposes minimal demand on the number of grid points without any convergence or stability problems. Criteria in terms of heat transfer and friction factor needed to choose the optimal wavy duct cross-section for industrial applications among the ones considered are discussed.

Rokni, Masoud↗

Turbulent Heat Transfer Characteristics in the Shear Layer of a Separated Flow

Experiments were performed to study the evolution of the heat transfer structure in a separated free shear layer region of an incompressible separated turbulent boundary layer flow behind a backward-facing step. While there is an abundance of velocity field measurements of separated flows, heat transfer measurements are rather scarce, thus limiting assessment of the heat transfer physics and its accurate modeling. The purpose of the paper is twofold: to improve an understanding of effects of flow separation on heat transfer characteristics, and to provide data for turbulence modeling and computation. The boundary layer upstream of the step was turbulent and fully developed. A constant temperature surface boundary condition was imposed upstream and downstream of the step for the heat transfer study. An internal mixing-layer like flow forms and grows from the step lip within the original boundary layer. The turbulent structure of the flow evolving downstream, however, does not switch immediately to that of a mixing layer over the entire shear layer thickness. Measurements of mean and fluctuating velocity and temperature fields indicate that the internal layer spreads gradually in the transverse direction while the outer part of the original boundary layer is effectively unperturbed. The results in this paper have not been previously reported.

Jovic, S.↗

Numerical analysis of coalescence-induced bubble departure for enhanced boiling heat transfer

Boiling heat transfer plays a crucial role in a wide range of applications, such as power generation, refrigeration, electronics cooling, and pharmaceutics. Among the various factors that influence boiling heat transfer, the dynamics of vapor bubble nucleation, growth, and departure from the heated surface stand out as particularly important. An emerging phenomenon that can promote the departure of bubbles smaller than the Fritz diameter is coalescence-induced departure. If the dynamics of this process are fully understood, then surfaces can be engineered to promote faster bubble departure and substantially increase the performance of boiling heat transfer. Further, this work expands on published results by presenting a detailed numerical analysis of bubble coalescence and departure for a range of initial bubble diameters and size ratios between coalescing bubbles. Analysis of the results is focused on explaining how the release of surface energy and bubble surface dynamics lead to bubble departure, as well as fundamentally distinguishing capillary–inertial jumping and buoyant–inertial departure mechanisms across different bubble sizes and size ratios. The results show that both the initial sizes of the coalescing bubbles and the ratio between their sizes can determine whether the merged bubble will leave the surface through capillary–inertial jumping or buoyant departure. Below a certain bubble size, the release of surface energy by the merger is not sufficient to propel the merged bubble from the surface.

42 ENGINEERING↗

Analysis of a Radioisotope Thermal Rocket Engine

The Triton Hopper is a concept for a global hopper vehicle which uses a radioisotope rocket engine and In-situ propellant acquisition to explore the surface of Neptune's moon, Triton. The current Triton Hopper concept stores heated Nitrogen in a spherical tank to be used as the propellant. The aim of the research was to investigate the benefits of storing propellant at ambient temperature and heating it through the use of a thermal block during engine operation, as opposed to storing gas at a high temperature. Lithium, Lithium Fluoride and Beryllium were considered as possible materials for the thermal block. A heat energy analysis indicated that a lithium thermal mass would provide the highest heat energy for a temperature change from 900 Celsius to -100 Celsius. A heat transfer analysis was performed for Nitrogen at -100 Celsius flowing through 1000 passages inside a 1kg lithium thermal block at a temperature of 900 Celsius. The system was analyzed as turbulent flow through a tube with constant surface temperature. The analysis indicated that the propellant reached a maximum temperature of 877 Celsius before entering the nozzle. At this exit temperature, the average specific impulse [I(sub sp)] of the engine was determined to be 157s. Previous studies for the stored heated gas concept suggest that the engine would have an average I(sub sp) of approximately 52s. Thus, the use of a thermal block concept results in a 200 percent engine performance increase. In addition, a tank sizing study was performed to determine if the concept is feasible in terms of mass requirements. The mass for a spherical carbon fiber COPV storing 35kg of nitrogen at an initial temperature of -100 Celsius and a pressure of 1000psia, was determined to be 7.2kg. The specific impulse analysis indicated that the maximum engine performance is obtained for a mass ratio of 5kg of Nitrogen per every 1kg of lithium thermal mass. Thus for 35kg of Nitrogen the total thermal mass would be 7kg. This brings the total mass of the system to 49.2.kg which is less than the 56kg landing payload capacity of the Triton Hopper. Finally, an insulation analysis using 10mm of MLI insulation indicated that a total of 22 watts of heat are lost to the environment. With the heat loss known, the power required to heat the thermal mass to 900 Celsius in 24 days was determined to be 2.15 watts. The study's results allowed us to conclude that the thermal mass concept is the better option due to the performance increase provided, the low power requirement and its compliance with the landing mass requirement of the Triton Hopper.

Radioisotope↗

Mathematical modeling of high and low temperature heat pipes

Following a review of heat and mass transfer theory relevant to heat pipe performance, math models are developed for calculating heat-transfer limitations of high-temperature heat pipes and heat-transfer limitations and temperature gradient of low temperature heat pipes. Calculated results are compared with the available experimental data from various sources to increase confidence in the present math models. Complete listings of two computer programs for high- and low-temperature heat pipes respectively are included. These programs enable the performance to be predicted of heat pipes with wrapped-screen, rectangular-groove, or screen-covered rectangular-groove wick.

Chi, S. W.↗

Impact of Periodic Unsteadiness on Performance and Heat Load in Axial Flow Turbomachines

Results of an analytical and experimental investigation, directed at the understanding of the impact of periodic unsteadiness on the time-averaged flows in axial flow turbomachines, are presented. Analysis of available experimental data, from a large-scale rotating rig (LSRR) (low speed rig), shows that in the time-averaged axisymmetric equations the magnitude of the terms representing the effect of periodic unsteadiness (deterministic stresses) are as large or larger than those due to random unsteadiness (turbulence). Numerical experiments, conducted to highlight physical mechanisms associated with the migration of combustor generated hot-streaks in turbine rotors, indicated that the effect can be simulated by accounting for deterministic stress like terms in the time-averaged mass and energy conservation equations. The experimental portion of this program shows that the aerodynamic loss for the second stator in a 1-1/2 stage turbine are influenced by the axial spacing between the second stator leading edge and the rotor trailing edge. However, the axial spacing has little impact on the heat transfer coefficient. These performance changes are believed to be associated with the change in deterministic stress at the inlet to the second stator. Data were also acquired to quantify the impact of indexing the first stator relative to the second stator. For the range of parameters examined, this effect was found to be of the same order as the effect of axial spacing.

Sharma, Om P.↗