Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

99 GENERAL AND MISCELLANEOUS↗

Solvent Degradation and Emissions from a 0.7MWe Pilot CO 2 Capture System with Two-stage Stripping

The UKy-CAER team successfully tested an advanced 0.7 MWe post-combustion CO 2 capture system on a coal-fired power plant using a heat integration process combined with two-stage stripping to enhance the CO 2 absorber performance. One of the unique feature of the UKy-CAER integrated process is a two-stage stripping unit for solvent regeneration. The secondary stripper is empowered by the heat rejection from a conventional steam-heated (primary) stripper. The secondary stripper outlet stream at the commercial scale can be used as boiler secondary combustion air, consequently enriching the flue gas with CO 2 , resulting in less energy penalty required by the CO2 capture system. The primary goal of this study was to form an initial assessment of the impact on the amine solvent from coal combustion flue gas contaminants and the potential higher oxygen content in the solvent due to incorporation of the secondary air stripper into the conventional amine scrubber/stripper system. The overall oxidative degradation was comparable to previous reports with 30 wt% MEA solvent at similar flue gas run hours. This suggests that the addition of the secondary air stripper appears to be negligible with regards to solvent oxidation.

20 FOSSIL-FUELED POWER PLANTS↗

The reservoir network: A new network topology for district heating and cooling

Thermal district networks are effective solutions to substitute fossil fuels with renewable energy sources for heating and cooling. Moreover, thermal networking of buildings allows energy efficiency to be further increased. The waste heat from cooling can be reused for heating in thermal district systems. Because of bidirectional energy flows between prosumers, thermal networks require new hydraulic concepts. In this work, we present a novel network topology for simultaneous heating and cooling: the reservoir network. The reservoir network is robust in operation due to hydraulic decoupling of transfer stations, integrates heat sources and heat sinks at various temperature levels and is flexible in terms of network expansion. Furthermore, we used Modelica simulations to compare the new single-pipe reservoir network to a basecase double-pipe network, taking yearly demand profiles of different building types for heating and cooling. The electric energy consumed by the heat pumps and circulations pumps differs between the reservoir and base case networks by less than 1%. However, if the reservoir network is operated with constant instead of variable mass flow rate, the total electrical consumption can increase by 48% compared to the base case. As with any other network topology, the design and control of such networks is crucial to achieving energy efficient operation. Investment costs for piping and trenching depend on the district layout and dimensioning of the network. If a ring layout is applied in a district, the reservoir network with its single-pipe configuration is more economical than other topologies. For a linear layout, the piping costs are slightly higher for the reservoir network than for the base case because of larger pipe diameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aeroheating Environments for a Mars Smart Lander

A proposed Mars Smart Lander is designed to reach the surface via lifting-body atmospheric entry (alpha = 16 deg) to within 10 km of the target site. CFD (computational fluid dynamics) predictions of the forebody aeroheating environments are given for a direct entry from a 2005 launch. The solutions were obtained using an 8-species gas in thermal and chemical nonequilibrium with a radiative-equilibrium wall temperature boundary condition. Select wind tunnel data are presented from tests at NASA Langley Research Center. Turbulence effects are included to account for both smooth body transition and turbulence due to heatshield penetrations. Natural transition is based on a momentum-thickness Reynolds number value of 200. The effects of heatshield penetrations on turbulence are estimated from wind tunnel tests of various cavity sizes and locations. Both natural transition and heatshield penetrations are predicted to cause turbulence prior to the nominal trajectory peak heating time. Laminar and turbulent CFD predictions along the trajectory are used to estimate heat rates and loads. The predicted peak turbulent heat rate of 63 W/sq cm on the heatshield leeward flank is 70% higher than the laminar peak. The maximum integrated heat load for a fully turbulent heat pulse is 38% higher than the laminar load on the heatshield nose. The predicted aeroheating environments with uncertainty factors will be used to design a thermal protection system.

Edquist, Karl T.↗

Techno-Economic Analysis and Life Cycle Assessment for the Separation of 2,3-Butanediol from Fermentation Broth Using Liquid–Liquid Extraction

It is energy-intensive to separate dilute 2,3-butanediol (2,3-BDO) (<10 wt %) from the aqueous phase of fermentation broth for sustainable aviation fuel (SAF) using conventional distillation. Liquid–liquid extraction (LLE) using oleyl alcohol as a solvent in a membrane extractor to extract BDO from water can significantly reduce the energy cost and minimize the potential emulsion. In an Aspen Plus model simulation, 95.2% BDO recovery and 97.1% BDO purity have been achieved using this LLE method with solvent recovery and heat integration. Here, the thermal energy cost was estimated to be 4.57 MJ/kg BDO, which is only about 16.8% of the lower heating value (LHV) of the BDO. This method consumes 81% less energy than the cascade distillation and reduces about $0.46/GGE (gasoline gallon equivalent) to the minimal fuel selling price. Meanwhile, the greenhouse gas (GHG) emission is 62% lower than petroleum-based jet fuel production and 34% less than using the cascade distillation.

09 BIOMASS FUELS↗

Water dissociative adsorption on NiO(111): Energetics and structure of the hydroxylated surface

The energetics of the reactions of water with metal oxide surfaces are of tremendous interest for catalysis, electrocatalysis, and geochemistry, yet the energy for the dissociative adsorption of water was only previously measured on one well-defined oxide surface, iron oxide. In the present paper, the enthalpy of the dissociative adsorption of water is measured on NiO(111)-2 × 2 at 300 K using single-crystal adsorption calorimetry. The differential heat of dissociative adsorption decreases with coverage from 170 to 117 kJ/mol in the first 0.25 ML of coverage. Water adsorbs molecularly on top of that, with a heat of ~92 kJ/mol. Density functional theory (DFT) calculations reproduce the measured energies well (all within 17 kJ/mol) and provide insight into the atomic-level structure of the surfaces studied experimentally. They show that the oxygen-terminated O-octo(2 × 2) structure is the most stable NiO(111)-2 × 2 termination and gives reaction energies with water that are more consistent with the calorimetry results than the metal-terminated surface. They show that water adsorbs dissociatively on this (2 × 2)-O-octo surface to produce a hydroxyl-covered surface with a heat of adsorption of 171 ± 5 kJ/mol in the low-coverage limit (very close to 170 kJ/mol experimentally) and an integral heat that decreases by 14 kJ/mol up to saturation (compared to ~30 kJ/mol experimentally). As a result, sensitivity of this reaction’s energy to choice of DFT method is tested using a variety of different exchange correlation functionals, including HSE06, and found to be quite weak.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and test of a self-controlled heat pipe radiator.

A 15,000-W spacecraft waste heat rejection system utilizing heat pipe radiator panels has been investigated. Of the several concepts initially identified, a series system was selected for more in-depth analysis. As a demonstration of system feasibility, a nominal 500-W radiator panel has been designed, built, and bench tested. The panel, which is a module of the 15,000-W system, consists of a variable conductance heat pipe (VCHP) header, and six isothermalizer heat pipes attached to a radiator. The thermal load to the VCHP is supplied by a Freon 21 liquid loop via an integral heat exchanger. This paper describes the results of the system studies and the radiator design. Also presented are test data on the VCHP, heat exchanger and isothermalizer heat pipes.

Swerdling, B.↗

Heat pipe radiator

A 15,000 watt spacecraft waste heat rejection system utilizing heat pipe radiator panels was investigated. Of the several concepts initially identified, a series system was selected for more in-depth analysis. As a demonstration of system feasibility, a nominal 500 watt radiator panel was designed, built and tested. The panel, which is a module of the 15,000 watt system, consists of a variable conductance heat pipe (VCHP) header, and six isothermalizer heat pipes attached to a radiating fin. The thermal load to the VCHP is supplied by a Freon-21 liquid loop via an integral heat exchanger. Descriptions of the results of the system studies and details of the radiator design are included along with the test results for both the heat pipe components and the assembled radiator panel. These results support the feasibility of using heat pipes in a spacecraft waste heat rejection system.

Swerdling, B.↗

Highly Efficient Regeneration Module for Carbon Capture Systems in NGCC Applications

The objective of this project is to design, fabricate, and test a highly efficient regeneration module capable of providing an ultra-lean absorption solution that is required for capturing CO 2 from dilute sources at 95% or better efficiency. By integrating this advanced regenerator module with SRI International’s Mixed Salt Process (MSP) absorption modules, SRI expects to demonstrate significant progress toward a reduction in cost of capture versus the DOE reference natural gas combined cycle (NGCC) plant with carbon capture. SRI designed, built, and tested an advanced stripper to enhance the performance of SRI’s MSP for CO 2 capture – a transformational ammonia-based solvent technology – for natural gas (NG) power sources. The testing of the advanced stripper for MSP was conducted at an SRI site using a simulated flue gas stream equivalent to about 10 kWe. The research work included modeling of the advanced stripper and integrating it with the MSP absorbers; studying the strategies for producing very highly alkaline lean solvent with minimized emissions; operating the stripper with advanced heat integration to improve process efficiencies; and collecting critically important data for a detailed techno-economic analysis (TEA). The project tasks were designed to address concerns relating to scale-up and integration of the technology to NG power plants—more specifically, to maximize the carbon capture efficiency achievable with MSP and identify pathways to achieve higher capture efficiencies and ultimately zero net carbon emissions. SRI teamed up with a process modeling company (OLI Systems), a process and chemical engineering company (Trimeric Corporation), and a cost-sharing commercial partner (Baker-Hughes – a leading multinational company that designs, manufactures, and services transformative energy technologies) to execute the project. The research findings will accelerate the MSP development and pave the way for the technology to reach the DOE’s goal, and ultimately commercialization of the MSP technology for low-cost CO 2 capture from NGCC flue gas and other dilute CO 2 sources.

03 NATURAL GAS↗

Observations of joule and particle heating in the auroral zone

Observational data from the Chatanika, Alaska incoherent scatter radar have been used to deduce atmospheric heating rates associated with particle precipitation and joule dissipation. During periods when Chatanika is in the vicinity of the auroral oval the height-integrated heat input to the lower thermosphere can be as large as 100 ergs per sq cm per sec with joule and particle heating rates of comparable magnitude. Altitude profiles of these heat inputs are also obtained, showing that the energy liberated by joule dissipation tends to peak at a substantially higher altitude (about 130 km) than that due to particles (100-120 km). As a consequence, it follows that joule heating can be expected to provide a rapid means for creating thermospheric disturbances. It is also pointed out that joule and particle heating are permanent features of the auroral oval and polar cap. As such, expansion of the auroral oval leads to an increase in the total global heating and, hence, to the close relationship between magnetic disturbances and thermospheric perturbation.

Banks, P. M.↗

Superconducting Cavity Cryomodule Designs for the Next Generation of CW Linacs: Challenges and Options

The designs of nearly all superconducting RF (SRF) linacs over the last several years, with one notable exception being CEBAF at Jefferson Lab, have assumed pulsed beam operation with relatively low duty factors. These include the XFEL at DESY, the ILC, the original configuration for Project X at Fermilab, as well as several others. Recently proposed projects, on the other hand, including the LCLS-II at SLAC, the newly configured low and medium energy sections for Project X, and FRIB at Michigan State, to name a few, assume continuous wave or CW operation on quite a large scale with ambitious gradients and cavity performance requirements. This has implications in the cavity design as well as in many parts of the overall cryomodule due to higher dynamic heat loads in the cavities themselves and higher heat loads in the input and high-order-mode (HOM) couplers. Piping internal to the cryomodule, the effectiveness of thermal intercepts, the size of integrated heat exchangers, and many other aspects of the overall design are also affected. This paper will describe some of these design considerations as we move toward the next generation of accelerator projects.

43 PARTICLE ACCELERATORS↗

Assessment of advanced solvent-based post-combustion CO 2 capture processes using a bi-objective optimization technique

We report the optimized performance of two advanced CO 2 capture processes is compared to that of a monoethanolamine (MEA) baseline for a gas-powered CO 2 capture retrofit of an existing coal-fired facility. The advanced temperature-swing processes utilize piperazine and mixed-salt solvents. The mixed-salt treatment involves the use of ammonia for CO 2 absorption and potassium carbonate primarily to control ammonia slip. The processes are represented in terms of energy duty requirements within a modular heat integration code developed for CO 2 capture modeling and optimization. The model includes a baseload coal plant, a gas-fired subsystem containing gas turbines and a heat recovery steam generator (HRSG), and a CO 2 capture facility. A formal bi-objective optimization procedure is applied to determine the design (e.g., detailed HRSG components and pressure levels, gas turbine capacity, CO 2 capture capacity) and time-varying operations of the facility to simultaneously maximize net present value (NPV) and minimize total capital requirement (TCR), while meeting a maximum CO 2 emission intensity constraint. For a realistic scenario constructed using historical data, optimization results indicate that both advanced processes outperform MEA in both objectives, and the mixed-salt process in turn outperforms the piperazine process. Specifically, for the scenario considered, the base case mixed-salt process achieves 16% greater NPV and 14% lower TCR than the MEA process, and 10% greater NPV and 5% lower TCR than the piperazine process. A five-case sensitivity study of the mixed-salt process indicates that it is competitive with the piperazine process and consistently outperforms the MEA process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Positive Power with Negative Emission Flexible NGCC Enable by Modular Direct Air Capture (Final Report)

The primary project objective was to synthesize a retrofit design of a natural gas combined cycle plant (Fseries gas turbines in 2x1 configuration) to integrate post-combustion (PCC) and direct air carbon capture (DAC) systems that could produce power with negative emissions across a wide range of loads, see table below. The IP-LP crossover and LP steam system of the NGCC were reconfigured to enable 97% CO2 capture in the PCC system at all loads, and heat integration with the DAC reduced the parasitic load of carbon capture by recovering the heat of condensation of the steam. Similar results were found for Hseries gas turbines.

03 NATURAL GAS↗

Aerothermodynamic Environment Definition for the Genesis Sample Return Capsule

NASA's Genesis sample return mission will be the first to return material from beyond the Earth-Moon system. NASA Langley Research Center supported this mission with aerothermodynamic analyses of the sample return capsule. This paper provides an overview of that effort. The capsule is attached through its forebody to the spacecraft bus. When the attachment is severed prior to Earth entry, forebody cavities remain. The presence of these cavities could dramatically increase the heating environment in their vicinity and downstream. A combination of computational fluid dynamics calculations and wind tunnel phosphor thermography tests were employed to address this issue. These results quantify the heating environment in and around the cavities, and were a factor in the decision to switch forebody heat shield materials. A transition map is developed which predicts that the flow aft of the penetrations will still be laminar at the peak heating point of the trajectory. As the vehicle continues along the trajectory to the peak dynamic pressure point, fully turbulent flow aft of the penetrations could occur. The integrated heat load calculations show that a heat shield sized to the stagnation point levels will be adequate for the predicted environment aft of the penetrations.

Cheatwood, F. McNeil↗

Integration of Solid Oxide Fuel Cell Systems Into Artificial Intelligence Data Centers

This report presents the results of a techno-economic analysis (TEA) that evaluates the economic benefits of integrating solid oxide fuel cell (SOFC) systems with artificial intelligence (AI) data centers. The analysis was completed in two phases: a scoping-level analysis was performed to identify impactful integration opportunities, followed by a more detailed TEA. Results show that, due to their modularity, SOFC can meet the 99.999% availability requirement of data centers with minimal additional costs. Heat integration via absorption chillers decreases data center electricity consumption at the tradeoff of increased water consumption. Higher SOFC exhaust temperatures are important for achieving larger electricity savings. Finally, power electronics integration with SOFC direct current electricity can reduce electricity consumption by 9 percent and reduce water consumption by 6.4 percent.

20 FOSSIL-FUELED POWER PLANTS↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗