Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HUMIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Humidity sensor

The present disclosure relates to a device that includes a light source, a detector; and a film having a first surface that includes a transition metal dichalcogenide, where the film is configured to interact with a volume of gas containing a concentration of water vapor, the light source is configured to shine a first light onto the first surface, the film is configured, as a result of the first light, to emit from the first surface a second light, the detector is configured to receive at least a portion of the second light, and the detector is configured to generate a signal proportional to an intensity of the second light.

Zhang, Hanyu↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

The controlling role of atmosphere in dawsonite versus gibbsite precipitation from tetrahedral aluminate species

In highly alkaline solution, aluminum speciates as the tetrahedrally coordinated aluminate monomer, Al(OH)4- and/or dimer Al2O(OH)62-, yet precipitates as octahedrally coordinated gibbsite (Al(OH)3). This tetrahedral to octahedral transformation governs Al precipitation, which is crucial to worldwide Al production, and to the processing of caustic high-level radioactive wastes. Despite its significance, the transformation pathway remains unknown. Here we explore the roles of atmospheric water and carbon dioxide in mediating the transformation of the tetrahedrally coordinated potassium aluminate dimer salt (K2Al2O(OH)6) to gibbsite versus potassium dawsonite (KAl(CO3)(OH)2). A combination of in-situ attenuated total reflection infrared spectroscopy, ex-situ micro X-ray diffraction, and multivariate curve resolution-alternating least squares chemometrics analysis reveals that humidity plays a key role in the transformation by limiting the amount of alkalinity neutralization by dissolved CO2. Lower humidity favors higher alkalinity and incorporation of carbonate species in the final Al product to form KAl(CO3)(OH)2. Higher humidity enables more acid generation that destabilizes dawsonite and favors gibbsite as the solubility limiting phase. Because the transformation was restricted to occur in thin water films, the results suggest that transition from tetra- to octahedrally coordinated Al does not have to occur in bulk solution, as has often been hypothesized, but may instead appear on the source mineral surface.

Dembowski, Mateusz↗

Fuel cell system

A fuel cell system comprising: a fuel cell, a fuel gas supplier configured to supply fuel gas to an anode of the fuel cell, an oxidant gas supplier configured to supply oxidant gas to a cathode of the fuel cell, a humidity adjuster configured to adjust a relative humidity of the fuel gas and a relative humidity of the oxidant gas, and a controller, wherein the controller detects the relative humidity of the fuel gas at an anode inlet of the fuel cell, and the controller detects the relative humidity of the oxidant gas at a cathode outlet of the fuel cell, and wherein, based on detection results, the controller controls the humidity adjuster so that the relative humidity of the fuel gas at the anode inlet is higher than the relative humidity of the oxidant gas at the cathode outlet.

Ando, Masaki↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review and Summary of Corrosion Behavior for Aluminum-Clad Spent Nuclear Fuel in Dry Storage

A description of the corrosion behavior of aluminum alloys used for cladding on aluminum-based, aluminum-clad nuclear fuel used in research reactors under potential dry storage conditions has been compiled. An evaluation is made of potential additional corrosion with water postulated to not be removed during drying. The relative humidity (RH) produced by typical dryness criteria for industrial spent nuclear fuel drying is expected to be low, particularly at high temperatures (17% RH at 20°C and lower at higher temperatures). Existing corrosion data suggests that negligible vapor-phase corrosion of aluminum is expected at such low humidity, even for nominally bare aluminum surfaces. That is, the predicted relative humidity from free water (e.g., 17% RH) is below the “critical” relative humidity (~40% RH at room temperature), below which no significant corrosion is observed for bare aluminum. Furthermore, reported room-temperature corrosion rates are very low even under saturated (100% RH) water vapor. Existing results showing significant vapor-phase corrosion corresponded specifically to conditions of high temper ed with high relative humidity. A relatively large reservoir of (chemically bound) water exists in the aluminum (oxy)hydroxide films on the SNF cladding surface. The estimated total could saturate the gas even at relatively high temperature if fully released; however, its release as molecular water is expected to only be plausible if the temperature during storage exceeds both the drying temperature and the threshold for thermal decomposition of the trihydroxides (~220°C). Therefore, the combination of high temperature and high relative humidity that could drive significant corrosion is considered implausible during sealed dry storage following an appropriate drying process, to include >220°C drying for canisters that may approach or exceed this temperature during storage. Vapor-phase testing of aluminum samples with an adherent (oxy)hydroxide layer, prepared in liquid water to resemble those on actual aluminum-clad spent nuclear fuel (ASNF), did not observe evidence of additional corrosion even at combined high-temperature (up to 180°C) and high-humidity (up to 100% RH) conditions. Instead, small net mass losses were observed for most specimens and attributed to dehydration of the samples, which had been air-dried only prior to testing. ASNF being moved to dry storage is expected to have an existing (oxy)hydroxide film, suggesting that the cladding will be less prone to additional corrosion than bare aluminum metal. If significant corrosion did occur during sealed storage, the overall extent and impact is expected to be small. Corrosion post-closure of a canister would not alter the total amount of hydrogen in the canister, so it would have no effect on the maximum H 2 release already assessed in existing bounding calculations. In addition, the total amount of water in a 25-µm dense bayerite film would consume a only ~8 µm additional aluminum metal on average, if fully consumed by oxidizing aluminum metal to Al 2 O 3 . These conclusions are consistent with ASNF-in-canister simulations to date, which included a reaction pathway for corrosion using kinetics from previous literature and believed to be conservative and predicted very low rates of corrosion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Near-Surface Warming Reduces Dew Frequency in China

Long-term (1961-2010) observations of dew data collected at 597 stations over China show that dew frequency decreased by 5.2 days per decade due primarily to near-surface warming and associated decreases in relative humidity (RH). Moreover, the percentage decreasing rate of dew frequency in arid regions (precipitation PR < 400 mm yr -1 ) are larger than that in humid regions (PR ≥ 800 mm yr -1 ). Compared with the 1960s, the mean dew frequency in the 2000s decreased by 28%, 40%, 50% in humid, semi-humid (400 ≤ PR<800 mm yr -1 ), and arid regions, respectively. Surface warming is larger in arid regions in northwestern China than its humid and semi-humid regions during recent global warming, which leads to larger decreases in surface RH and makes dew events less likely. Here, since dew contributes significantly to surface water balance in arid regions, the large decreases in dew frequency may contribute to "the drier getting drier" response to global warming over arid regions.

54 ENVIRONMENTAL SCIENCES↗

Grounding our Understanding of the Impacts of Boreal Forest Expansion on Shallow Cumulus Clouds with a Simple Modeling Framework

Abstract The expansion of the boreal forest poleward is a potentially important driver of feedbacks between the land surface and Arctic climate. A growing body of work has highlighted the importance of differences in evaporative resistance between different possible future Arctic land covers, which in turn alters humidity and cloudiness in the boundary layer, for these feedbacks. While thus far this problem has been studied primarily with complex Earth system models, we turn to a locally focused, idealized model capable of diagnosing and testing the sensitivity of first-order processes connecting vegetation, the atmospheric boundary layer, and low clouds in this critical region. This allows us to benchmark the mechanisms and results at the center of predictions from larger-scale simulations. A surface dominated by broadleaf trees, characterized by higher albedo and lower surface evaporative resistance, drives cooling and moistening of the boundary layer relative to a surface of needleleaf trees, characterized by lower albedo and higher surface evaporative resistance. Differences in evaporative resistance between these hypothetical Arctic vegetation covers are of equal importance to changes in albedo for the initial response of the boundary layer to boreal expansion, even with our idealized approach. However, compensation between the elevation of the lifting condensation level (LCL) and more rapid growth of the mixed layer over higher evaporative resistance surfaces can minimize changes in the favorability of shallow clouds over different land cover types under some conditions. We then perform two tests on the sensitivity of this compensating effect, to changes in water availability, represented first by a reduction in boundary layer humidity and then by both a reduction in humidity and soil moisture available to our vegetation surface. Finally, given the importance of this potential LCL–mixed-layer height compensation in our idealized modeling results, we look to determine its relevance in observational data from a field campaign in boreal Finland. These observations do confirm that such a coupling plays an important role in cumulus-topped boundary layers over a needleleaf forest surface. While our results confirm some underlying mechanisms at the center of prior work with Earth system models, they also provide motivation for future work to constrain the impact of boreal forest expansion. This will include both large eddy simulations to examine the impact of processes and feedbacks not resolved by a mixed-layer model, as well as a more systematic evaluation and comparison of relevant observations at the site in Finland and sites from prior boreal field campaigns. Significance Statement Clouds and vegetation are both important components of the climate system that interact across a range of scales. These interactions are central to understanding how changes at the land surface feedback on climate. For example, if a forest expands or recedes, diagnosing how that will impact clouds will determine whether you predict warming or cooling temperatures from that shift in the forest area. These predictions are often made with complex Earth system models, but we look to a more idealized representation of the land–atmosphere system to diagnose how shallow clouds should respond to changes in surface properties with different scenarios of boreal forest expansion at a more foundational level. This both grounds our understanding of previous analysis and provides helpful direction for future studies of this relevant and impactful land cover change.

Meteorology & Atmospheric Sciences↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method and apparatus for desalinating water

This disclosure concerns a system and a method for removing dissolved solids from liquids. Specific implementations concern desalinating water. The system may comprise a blower, such as a thermal fan/compressor, configured to atomize a solid-bearing liquid to produce a hot, humid gas containing dissolved solids; a gas-solid separator configured to receive hot, humid gas containing entrained dissolved solids from the blower to separate the solids from the humid gas and to transmit the humid gas with solids removed through an exit port; a heater configured to heat the hot, humid gas received from the exit port of the gas-solid separator; and a condenser configured to receive heated humid gas from the heater and to condense solids-free liquid therefrom. The thermal fan/compressor may comprise a plurality of nozzles with outlets positioned adjacent atomization apertures across which a solid-bearing liquid flows and through which gas exiting the nozzles passes.

Abbasi, Bahman↗

Method and apparatus for desalinating water

This disclosure concerns a system and a method for removing dissolved solids from liquids. Specific implementations concern desalinating water. The system may comprise a blower, such as a thermal fan/compressor, configured to atomize a solid-bearing liquid to produce a hot, humid gas containing dissolved solids; a gas-solid separator configured to receive hot, humid gas containing entrained dissolved solids from the blower to separate the solids from the humid gas and to transmit the humid gas with solids removed through an exit port; a heater configured to heat the hot, humid gas received from the exit port of the gas-solid separator; and a condenser configured to receive heated humid gas from the heater and to condense solids-free liquid therefrom. The thermal fan/compressor may comprise a plurality of nozzles with outlets positioned adjacent atomization apertures across which a solid-bearing liquid flows and through which gas exiting the nozzles passes.

Abbasi, Bahman↗

Multitarget control models for building thermal comfort and indoor air quality - A critical review

The control techniques in buildings contribute significantly to thermal comfort and indoor air quality (IAQ). However, the gaps are existing for multitarget controls considering both thermal comfort and IAQ. They are: (1) both experimental and modeling control studies were conducted for thermal comfort, focusing on temperature and humidity. (2) All three (physical, grey-box, black-box) modeling approaches were investigated for temperature control. (3) Physical and grey-box modeling approach were adopted for humidity control. (4) physical models were developed for VOCs and CO2 control. (5) grey-box and black-box models were lacking for VOCs and CO2. (6) Multi-target controls were lacking for temperature, humidity and CO2s. (7) Limited studies are available for multi-target controls for temperature, humidity, and VOCs. (8) Multi-target controls are not available yet for temperature, humidity, VOCs, and CO2.

42 ENGINEERING↗