Severe Gastrointestinal Haemorrhage: Summary of a National Quality of Care Study with Focus on Radiological Services

Purpose of StudyTo identify the remediable factors in the quality of care provided to patients with severe gastrointestinal (GI) bleeding.MethodAll hospital admissions in the first four months of 2013 with ICD10 coding for GI bleeding who received a transfusion of 4 units or more of blood. Up to five cases/hospital randomly selected for structured case note peer review. National availability of GI bleeding services data derived from organisational questionnaire completed by all hospitals.Results4563/29,796 (15.3%) of GI bleeds received 4 or more units of blood with a mortality rate of 20.2% compared to 7.3% without blood transfusion. 30.8% of GI bleeds received a blood transfusion. 32% (60/185) of hospitals admitting acute GI bleeds lacked 24/7 endoscopy. 26% (48/185) had on-site embolisation 24/7 with a further 34% (64/185) accessing embolisation by transfer within a validated formal network. Blood product use was inappropriate in 20% (84/426). Improved management, principally earlier senior gastroenterologist review and/or endoscopy, would have reduced blood product use in 25% (113/457). 14.5% (90/618) had a CT scan which identified the site of bleeding in 32% (29/90). 7.8% (36/459) underwent an Interventional Radiology (IR) procedure but a further 6.3% (21/33) should have had IR. 6% (36/586) underwent surgery with 21/36 for uncontrolled bleeding. In 20/35 IR was not considered despite the majority being suitable for IR. Overall 44% (210/476) received an acceptable standard of care according to peer review.Conclusions26 recommendations were made to improve the quality of care in GI bleeding, with six principle recommendations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Prediction of New Adjacent Vertebral Fractures After PVP for Patients with Vertebral Compression Fractures: Development of a Prediction Model

PurposeWe aim to determine the predictors of new adjacent vertebral fractures (AVCFs) after percutaneous vertebroplasty (PVP) in patients with osteoporotic vertebral compression fractures (OVCFs) and to construct a risk prediction score to estimate a 2-year new AVCF risk-by-risk factor condition.Materials and MethodsPatients with OVCFs who underwent their first PVP between December 2006 and December 2013 at Hospital A (training cohort) and Hospital B (validation cohort) were included in this study. In training cohort, we assessed the independent risk predictors and developed the probability of new adjacent OVCFs (PNAV) score system using the Cox proportional hazard regression analysis. The accuracy of this system was then validated in both training and validation cohorts by concordance (c) statistic.Results421 patients (training cohort: n = 256; validation cohort: n = 165) were included in this study. In training cohort, new AVCFs after the first PVP treatment occurred in 33 (12.9%) patients. The independent risk factors were intradiscal cement leakage and preexisting old vertebral compression fracture(s). The estimated 2-year absolute risk of new AVCFs ranged from less than 4% in patients with neither independent risk factors to more than 45% in individuals with both factors.ConclusionsThe PNAV score is an objective and easy approach to predict the risk of new AVCFs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of Preoperative Transcatheter Arterial Embolization for Nasopharyngeal Angiofibroma: A Comparative Study

ObjectiveThis study aimed to retrospectively evaluate the efficacy and safety of preoperative transcatheter arterial embolization (pTAE) for treating nasopharyngeal angiofibroma (NPAF).MethodsSeventy-four NPAF patients were hospitalized for elective surgical treatment with pTAE (pTAE group, n = 32) or surgical treatment alone (non-pTAE group, n = 42) between January 1990 and December 2013. The following outcome measures were retrospectively analyzed and compared: intraoperative bleeding volume, surgery time (ST), duration of postoperative hospital stay (PHS), and disease recurrence.ResultsAmong Radkowski stage I patients, those in pTAE group had a slightly higher but not significant bleeding volume than patients in non-pTAE group (344 ± 407 vs. 248 ± 219 mL, P = 0.899); among stage II/III patients, however, patients in pTAE group showed a significantly lower bleeding volume than patients in non-pTAE group (stage II, 829 ± 519 vs. 1339 ± 767 mL, P = 0.035; stage III, 1267 ± 592 vs. 2125 ± 479 mL, P = 0.024). The two groups presented comparable OTs, PHSs, and rates of frontal recurrence (all P>0.05).ConclusionspTAE significantly reduces intraoperative bleeding in NPAF patients with Radkowski stage II/III disease, but offers no additional benefits regarding ST, PHS, or recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incidence and Consequence of Nontarget Embolization Following Bland Hepatic Arterial Embolization

Purpose: Estimate the incidence of nontarget embolization (NTE) as identified on immediate post-hepatic artery embolization CT. Materials and Methods: Two hundred hepatic embolizations performed with particles alone (bland embolization) in 147 patients between August 16, 2013 and August 26, 2014 with immediate post-procedure CT were retrospectively reviewed. Arterial anatomy, vessels treated, imaging findings of NTE, patient demographics, length of hospital stay following embolization, and procedure-related complications were recorded. The data were analyzed using two-sided t-tests and chi-squared tests. Results: Evidence of NTE was seen on post-procedure CT in 64 of 200 cases (64/200, 32%). Six organs were affected, with 69 discrete sites in 64 patients. The majority (49/69, 71.0%) involved the gallbladder. The mean length of hospital stay (LOS) for patients with and without NTE was 2.9 ± 1.5 nights (range 1–7) and 2.9 ± 2.3 nights (range 0–21), respectively (P = 0.81). NTE was more common following embolization of replaced or accessory hepatic vessels. There were three complications in the NTE group (3/64, 4.7%) following the embolization procedure, one of which was cholecystitis directly related to NTE. The other two were one incidence each of contrast-induced nephropathy and pneumonia. In the group without NTE, seven complications occurred (7/136, 5.1%, P = 0.889), including one death resulting from hepatic failure, two gastrointestinal bleeds, two hepatic abscesses, flash pulmonary edema, and pancreatitis. Conclusion: Unanticipated NTE is not uncommon after bland hepatic artery embolization, particularly after treating accessory or replaced vessels, but does not increase complications or LOS. Level of Evidence: Level 2b, Retrospective Cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systematic Layout Planning of a Radiology Reporting Area to Optimize Radiologists’ Performance

Optimizing radiologists’ performance is a major priority for managers of health services/systems, since the radiologists’ reporting activity imposes a severe constraint on radiology productivity. Despite that, methods to optimize radiologists’ reporting workplace layout are scarce in the literature. This study was performed in the Radiology Division (RD) of an 850-bed University-based general hospital. The analysis of the reporting workplace layout was carried out using the systematic layout planning (SLP) method, in association with cluster analysis as a complementary tool in early stages of SLP. Radiologists, architects, and hospital managers were the stakeholders consulted for the completion of different stages of the layout planning process. A step-by-step description of the proposed methodology to plan an RD reporting layout is presented. Clusters of radiologists were defined using types of exams reported and their frequency of occurrence as clustering variables. Sectors with high degree of interaction were placed in proximity in the new RD layout, with separation of noisy and quiet areas. Four reporting cells were positioned in the quiet area, grouping radiologists by subspecialty, as follows: cluster 1-abdomen; cluster 2-musculoskeletal; cluster 3-neurological, vascular and head & neck; cluster 4-thoracic and cardiac. The creation of reporting cells has the potential to limit unplanned interruptions and enhance the exchange of knowledge and information within cells, joining radiologists with the same expertise. That should lead to improvements in productivity, allowing managers to more easily monitor radiologists’ performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping.

54 ENVIRONMENTAL SCIENCES↗

Leisure time activities related to carcinogen exposure and lung cancer risk in never smokers. A case-control study

We aim to assess the relationship between leisure time activities related to exposure to carcinogenic substances and lung cancer risk in a hospital-based case-control study performed in never smokers. We included never smoking cases with anatomopathologically confirmed lung cancer and never smoking controls undergoing trivial surgery, at 8 Spanish hospitals. The study was conducted between January 2011 and June 2013. Participants were older than 30 and had no previous neoplasms. All were personally interviewed focusing on lifestyle, environmental tobacco smoke exposure, occupational history and leisure time activities (including duration of such activities). Results were analyzed through logistic regression and adjusted also by residential radon and education level. We included 513 never smokers, 191 cases and 322 controls. The OR for those performing the studied leisure time activities was 1.43 (95%CI 0.78–2.61). When we restricted the analysis to those performing do-it-yourself activities for more than 10 years the OR was 2.21 (95%CI 0.93–5.27). Environmental tobacco smoke exposure did not modify this association. The effect for the different lung cancer histological types was very close to significance for adenocarcinoma but only when these activities were performed for more than 10 years. We encourage health professionals to recommend protective measures for those individuals while performing these hobbies to reduce the risk of lung cancer. - Highlights: • Some leisure time activities are associated with the exposure to carcinogenic substances. • These activities are model-making, painting (artistic or not), furniture refinishing or wood working. • Few studies have assessed lung cancer risk due to these hobbies and none in never-smokers. • Leisure activities related to exposure to carcinogenic substances present higher lung cancer risk. • The risk is higher when these activities are performed for more than 10 years.

54 ENVIRONMENTAL SCIENCES↗

The burden of overall and cause-specific respiratory morbidity due to ambient air pollution in Sichuan Basin, China: A multi-city time-series analysis

Highlights: • We assess the burden of respiratory HAs due to air pollution in Southwest China. • Risks of respiratory HAs were elevated following increased PM{sub 10}, PM{sub 2.5}, NO{sub 2} and SO{sub 2}. • The effect estimates might be modified by age, season and region. • 1.84% of respiratory HAs were attributed to PM{sub 10}, 1.73% to PM{sub 2.5} and 0.34% to SO{sub 2}. Few studies have investigated the respiratory morbidity burden due to ambient air pollution in China, especially in a multi-city setting. This study aimed to estimate the short-term effects of ambient air pollutants (PM{sub 10}, PM{sub 2.5}, NO{sub 2} and SO{sub 2}) on hospital admissions (HAs) for overall and cause-specific respiratory diseases, as well as the associated burden in 17 cities of Sichuan Basin, China during 2015–2016. Firstly, city-specific effect estimates for each pollutant on respiratory HAs were obtained using generalized additive model with quasi-Poisson link, and then random- or fixed-effects meta-analysis was applied to pool the effect estimates at the regional level. Subgroup analyses by sex, age, season and region were also performed. A total of 757,712 respiratory HAs were collected from all the tertiary and secondary hospitals located in the 17 cities. Risks of HAs for overall and cause-specific respiratory diseases were elevated following increased PM{sub 10}, PM{sub 2.5}, NO{sub 2} and SO{sub 2} exposure. An increase of 10 μg/m{sup 3} in PM{sub 10} at lag01, PM{sub 2.5} at lag01, NO{sub 2} at lag0 and SO{sub 2} at lag02 was associated with a 0.43% (95% CI: 0.33%, 0.53%), 0.53% (95% CI: 0.39%, 0.68%), 2.36% (95% CI: 1.75%, 2.98%) and 2.54% (95% CI: 1.51%, 3.59%) increases in total respiratory HAs, respectively. Children (≤ 14 years) and elderly (≥ 65 years) appeared to be more vulnerable to the effects of ambient air pollutants. Comparing to the WHO's air quality guidelines, we estimated that 1.84% (95%CI: 1.42%, 2.25%), 1.73% (95%CI: 1.27%, 2.19%) and 0.34% (95%CI: 0.21%, 0.48%) of respiratory HAs were due to PM{sub 10}, PM{sub 2.5} and SO{sub 2} exposure, respectively. This study suggests that air pollution might be an important trigger of respiratory admissions, and result in substantial burden of HAs for respiratory diseases in Sichuan Basin.

54 ENVIRONMENTAL SCIENCES↗

An Assessment of the Current US Radiation Oncology Workforce: Methodology and Global Results of the American Society for Radiation Oncology 2012 Workforce Study

Purpose: To determine the characteristics, needs, and concerns of the current radiation oncology workforce, evaluate best practices and opportunities for improving quality and safety, and assess what we can predict about the future workforce. Methods and Materials: An online survey was distributed to 35,204 respondents from all segments of the radiation oncology workforce, including radiation oncologists, residents, medical dosimetrists, radiation therapists, medical physicists, nurse practitioners, nurses, physician assistants, and practice managers/administrators. The survey was disseminated by the American Society for Radiation Oncology (ASTRO) together with specialty societies representing other workforce segments. An overview of the methods and global results is presented in this paper. Results: A total of 6765 completed surveys were received, a response rate of 19%, and the final analysis included 5257 respondents. Three-quarters of the radiation oncologists, residents, and physicists who responded were male, in contrast to the other segments in which two-thirds or more were female. The majority of respondents (58%) indicated they were hospital-based, whereas 40% practiced in a free-standing/satellite clinic and 2% in another setting. Among the practices represented in the survey, 21.5% were academic, 25.2% were hospital, and 53.3% were private. A perceived oversupply of professionals relative to demand was reported by the physicist, dosimetrist, and radiation therapist segments. An undersupply was perceived by physician's assistants, nurse practitioners, and nurses. The supply of radiation oncologists and residents was considered balanced. Conclusions: This survey was unique as it attempted to comprehensively assess the radiation oncology workforce by directly surveying each segment. The results suggest there is potential to improve the diversity of the workforce and optimize the supply of the workforce segments. The survey also provides a benchmark for future studies, as many changes in the healthcare field exert pressure on the workforce.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Phase 3 Trial of Domiciliary Humidification to Mitigate Acute Mucosal Toxicity During Radiation Therapy for Head-and-Neck Cancer: First Report of Trans Tasman Radiation Oncology Group (TROG) 07.03 RadioHUM Study

Purpose: To assess the impact of domicile-based humidification on symptom burden during radiation therapy (RT) for head-and-neck (H and N) cancer. Methods and Materials: From June 2007 through June 2011, 210 patients with H and N cancer receiving RT were randomized to either a control arm or to receive humidification using the Fisher and Paykel Healthcare MR880 humidifier. Humidification commenced on day 1 of RT and continued until Common Terminology Criteria for Adverse Events (CTCAE), version 3.0, clinical mucositis (CMuc) grade ≤1 occurred. Forty-three patients (42%) met a defined benchmark for humidification compliance and contributed to per protocol (PP) analysis. Acute toxicities, hospitalizations, and feeding tube events were recorded prospectively. The McMaster University Head and Neck Radiotherapy Questionnaire (HNRQ) was used for patient-reported outcomes. The primary endpoint was area under the curve (AUC) for CMuc grade ≥2. Results: There were no significant differences in AUC for CMuc ≥2 between the 2 arms. Humidification patients had significantly fewer days in hospital (P=.017). In compliant PP patients, the AUC for CTCAE functional mucositis score (FMuc) ≥2 was significantly reduced (P=.009), and the proportion who never required a feeding tube was significantly greater (P=.04). HNRQ PP analysis estimates also in the direction favoring humidification with less symptom severity, although differences at most time points did not reach significance. Conclusions: TROG 07.03 has provided efficacy signals consistent with a role for humidification in reducing symptom burden from mucositis, but the influence of humidification compliance on the results moderates recommendations regarding its practical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mobile Technology and Social Media in the Clinical Practice of Young Radiation Oncologists: Results of a Comprehensive Nationwide Cross-sectional Study

Purpose: Social media and mobile technology are transforming the way in which young physicians are learning and practicing medicine. The true impact of such technologies has yet to be evaluated. Methods and Materials: We performed a nationwide cross-sectional survey to better assess how young radiation oncologists used these technologies. An online survey was sent out between April 24, 2013, and June 1, 2013. All residents attending the 2013 radiation oncology French summer course were invited to complete the survey. Logistic regressions were performed to assess predictors of use of these tools in the hospital on various clinical endpoints. Results: In all, 131 of 140 (93.6%) French young radiation oncologists answered the survey. Of these individuals, 93% owned a smartphone and 32.8% owned a tablet. The majority (78.6%) of the residents owning a smartphone used it to work in their department. A total of 33.5% had more than 5 medical applications installed. Only 60.3% of the residents verified the validity of the apps that they used. In all, 82.9% of the residents had a social network account. Conclusions: Most of the residents in radiation oncology use their smartphone to work in their department for a wide variety of tasks. However, the residents do not consistently check the validity of the apps that they use. Residents also use social networks, with only a limited impact on their relationship with their patients. Overall, this study highlights the irruption and the risks of new technologies in the clinical practice and raises the question of a possible regulation of their use in the hospital.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Approach to Postmastectomy Radiation Therapy Using Scanned Proton Beams

Purpose: Postmastectomy radiation therapy (PMRT), currently offered at Massachusetts General Hospital, uses proton pencil beam scanning (PBS) with intensity modulation, achieving complete target coverage of the chest wall and all nodal regions and reduced dose to the cardiac structures. This work presents the current methodology for such treatment and the ongoing effort for its improvements. Methods and Materials: A single PBS field is optimized to ensure appropriate target coverage and heart/lung sparing, using an in–house-developed proton planning system with the capability of multicriteria optimization. The dose to the chest wall skin is controlled as a separate objective in the optimization. Surface imaging is used for setup because it is a suitable surrogate for superficial target volumes. In order to minimize the effect of beam range uncertainties, the relative proton stopping power ratio of the material in breast implants was determined through separate measurements. Phantom measurements were also made to validate the accuracy of skin dose calculation in the treatment planning system. Additionally, the treatment planning robustness was evaluated relative to setup perturbations and patient breathing motion. Results: PBS PMRT planning resulted in appropriate target coverage and organ sparing, comparable to treatments by passive scattering (PS) beams but much improved in nodal coverage and cardiac sparing compared to conventional treatments by photon/electron beams. The overall treatment time was much shorter than PS and also shorter than conventional photon/electron treatment. The accuracy of the skin dose calculation by the planning system was within ±2%. The treatment was shown to be adequately robust relative to both setup uncertainties and patient breathing motion, resulting in clinically satisfying dose distributions. Conclusions: More than 25 PMRT patients have been successfully treated at Massachusetts General Hospital by using single-PBS fields. The methodology and robustness of both the setup and the treatment have been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship Between Radiation Therapy Dose and Outcome in Patients Treated With Neoadjuvant Chemoradiation Therapy and Surgery for Stage IIIA Non-Small Cell Lung Cancer: A Population-Based, Comparative Effectiveness Analysis

Purpose: To compare, using the National Cancer Database, survival, pathologic, and surgical outcomes in patients with stage IIIA non-small cell lung cancer treated with differential doses of neoadjuvant chemoradiation therapy, with the aim to discern whether radiation dose escalation was associated with a comparative effectiveness benefit and/or toxicity risk. Methods and Materials: Patients in the National Cancer Database with stage IIIA non-small cell lung cancer treated with neoadjuvant chemoradiation therapy and surgery between 1998 and 2005 were analyzed. Dose strata were divided between 36 to 45 Gy (low-dose radiation therapy, LD-RT), 45 to 54 Gy (inclusive, standard-dose, SD-RT), and 54 to 74 Gy (high-dose, HD-RT). Outcomes included overall survival, residual nodal disease, positive surgical margin status, hospital length of stay, and adverse surgical outcomes (30-day mortality or readmission). Results: The cohort consisted of 1041 patients: 233 (22%) LD-RT, 584 (56%) SD-RT, and 230 (22%) HD-RT. The median, 3-year, and 5-year overall survival outcomes were 34.9 months, 48%, and 37%, respectively. On univariable analysis, patients treated with SD-RT experienced prolonged overall survival (median 38.3 vs 31.8 vs 29.0 months for SD-RT, LD-RT, and HD-RT, respectively, P=.0089), which was confirmed on multivariable analysis (hazard ratios 0.77 and 0.81 vs LD and HD, respectively). Residual nodal disease was seen less often after HD-RT (25.5% vs 31.8% and 37.5% for HD-RT, LD-RT, and SD-RT, respectively, P=.0038). Patients treated with SD-RT had fewer prolonged hospital stays. There were no differences in positive surgical margin status or adverse surgical outcomes between the cohorts. Conclusions: Neoadjuvant chemoradiation therapy between 45 and 54 Gy was associated with superior survival in comparison with doses above and below this threshold. Although this conclusion is limited by selection bias, clear candidates for trimodality therapy do not seem to achieve additional benefit with dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The antimicrobial cathelicidin peptide hlF(1-11) attenuates alveolar macrophage pyroptosis induced by Acinetobacter baumannii in vivo

Acinetobacter baumannii is a Gram-negative coccobacillus found primarily in hospital settings that has recently emerged as a source of hospital-acquired infections, including bacterial pneumonia. The hLF(1-11) peptide comprising the first 11 N-terminal residues of human lactoferrin exerts antimicrobial activity in vivo and was highly effective against multidrug-resistant A. baumannii strains in vitro and in vivo. Pyroptosis is a caspase-1-dependent inflammatory cell death process and is induced by various microbial infections. In the present study, we investigated the molecular mechanisms that regulate pyroptosis induced by A. baumannii in macrophages. Our results revealed that A. baumannii induced pyroptosis through caspase-1 activation and IL-1β production. We also found that caspase-1 activation and IL-1β maturation in A. baumannii-triggered pyroptotic cell death were reduced by hLF(1-11) treatment. Moreover, hLF(1-11) inhibited the A. baumannii-induced caspase-1 activation and pyroptosis of pulmonary alveolar macrophages in vivo.

60 APPLIED LIFE SCIENCES↗

Invited Article: In situ comparison of passive radon-thoron discriminative monitors at subsurface workplaces in Hungary

During a one-year long measurement period, radon and thoron data obtained by two different passive radon-thoron discriminative monitors were compared at subsurface workplaces in Hungary, such as mines (bauxite and manganese ore) and caves (medical and touristic). These workplaces have special environmental conditions, such as, stable and high relative humidity (100%), relatively stable temperature (12°C–21°C), low or high wind speed (max. 2.4 m s{sup −1}) and low or elevated aerosol concentration (130–60 000 particles m{sup −3}). The measured radon and thoron concentrations fluctuated in a wide range among the different workplaces. The respective annual average radon concentrations and their standard deviations (in brackets) measured by the passive radon-thoron discriminative monitor with cellulose filter (CF) and the passive radon-thoron discriminative monitor with sponge filter (SF) were: 350(321) Bq m{sup −3} and 550(497) Bq m{sup −3} in the bauxite mine; 887(604) Bq m{sup −3} and 1258(788) Bq m{sup −3} in the manganese ore mine; 2510(2341) Bq m{sup −3} and 3403(3075) Bq m{sup −3} in the medical cave (Hospital Cave of Tapolca); and 6239(2057) Bq m{sup −3} and 8512(1955) Bq m{sup −3} in the touristic cave (Lake Cave of Tapolca). The respective average thoron concentrations and their standard deviation (in brackets) measured by CF and SF monitors were: 154(210) Bq m{sup −3} and 161(148) Bq m{sup −3} in the bauxite mine; 187(191) Bq m{sup −3} and 117(147) Bq m{sup −3} in the manganese-ore mine; 360(524) Bq m{sup −3} and 371(789) Bq m{sup −3} in the medical cave (Hospital Cave of Tapolca); and 1420(1184) Bq m{sup −3} and 1462(3655) Bq m{sup −3} in the touristic cave (Lake Cave of Tapolca). Under these circumstances, comparison of the radon data for the SF and CF monitors showed the former were consistently 51% higher in the bauxite mine, 38% higher in the manganese ore mine, and 34% higher in the caves. Consequently, correction is required on previously obtained radon data acquired by CF monitors at subsurface workplaces to gain comparable data for SF monitors. In the case of thoron, the data were unreliable and no significant tendency was seen during the comparison therefore comparison of previously obtained thoron data acquired by either CF or SF is doubtful. There was probable influence by relative humidity on the detection response; however, the effects of the high wind speed and elevated aerosol concentration could not be excluded. The results of this study call attention to the importance of calibration under extreme environmental conditions and the need for using reliable radon-thoron monitors for subsurface workplaces.

54 ENVIRONMENTAL SCIENCES↗

Beam related response of in vivo diode detectors for external radiotherapy

In Vivo Dosimetry (IVD) is a set of methods used in cancer treatment clinics to determine the real dose of radiation absorbed by target volume in a patient’s body. IVD has been widely implemented in radiotherapy treatment centers and is now recommended part of Quality Assurance program by many International health and radiation organizations. Because of cost and lack of specialized personnel, IVD has not been practiced as yet, in Albanian radiotherapy clinics. At Hygeia Hospital Tirana, patients are irradiated with high energy photons generated by Elekta Synergy Accelerators. We have recently started experimenting with the purpose of establishing an IVD practice at this hospital. The first set of experiments was aimed at calibration of diodes that are going to be used for IVD. PMMA, phantoms by PTW were used to calibrate p – type Si, semiconductor diode dosimeters, made by PTW Freiburg for entrance dose. Response of the detectors is affected by energy of the beam, accumulated radiation dose, dose rate, temperature, angle against the beam axis, etc. Here we present the work done for calculating calibration factor and correction factors of source to surface distance, field size, and beam incidence for the entrance dose for both 6 MV photon beam and 18 MV photon beam. Dependence of dosimeter response was found to be more pronounced with source to surface distance as compared to other variables investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-P-01: An Informative Review On the Role of Diagnostic Medical Physicist in the Academic and Private Medical Centers

Purpose: The role of physicist in the academic and private hospital environment continues to evolve and expand. This becomes more obvious with the newly revised requirements of the Joint Commission (JC) on imaging modalities and the continued updated requirements of ACR accreditation for medical physics (i.e., starting in June 2014, a physicists test will be needed before US accreditation). We provide an informative review on the role of diagnostic medical physicist and hope that our experience will expedite junior physicists in understanding their role in medical centers, and be ready to more opportunities. Methods: Based on our experience, diagnostic medical physicists in both academic and private medical centers perform several clinical functions. These include providing clinical service and physics support, ensuring that all ionizing radiation devices are tested and operated in compliance with the State and Federal laws, regulations and guidelines. We also discuss the training and education required to ensure that the radiation exposure to patients and staff is as low as reasonably achievable. We review the overlapping roles of medical and health physicist in some institutions. Results: A detailed scheme on the new requirements (effective 7/1/2014) of the JC is provided. In 2015, new standards for fluoroscopy, cone beam CT and the qualifications of staff will be phased in. A summary of new ACR requirements for different modalities is presented. Medical physicist have other duties such as sitting on CT and fluoroscopy committees for protocols design, training of non-radiologists to meet the new fluoroscopy rules, as well as helping with special therapies such as Yittrium 90 cases. Conclusion: Medical physicists in both academic and private hospitals are positioned to be more involved and prominent. Diagnostic physicists need to be more proactive to involve themselves in the day to day activities of the radiology department.

60 APPLIED LIFE SCIENCES↗

SU-E-I-10: Automatic Monitoring of Accumulated Dose Indices From DICOM RDSR to Improve Radiation Safety in X-Ray Angiography

Purpose: To investigate the potential benefits of automatic monitoring of accumulated patient and staff dose indicators, i.e., CAK and KAP, from DICOM Radiation Dose Structured Reports (RDSR) in x-ray angiography (XA). Methods: Recently RDSR has enabled the convenient aggregation of dose indices and technique parameters for XA procedures. The information contained in RDSR objects for three XA systems, dedicated to different types of clinical procedures, has been collected and aggregated in a database for over one year using a system developed with open-source software at the Karolinska University Hospital. Patient weight was complemented to the RDSR data via an interface with the Hospital Information System (HIS). Results: The linearly approximated trend in KAP over a time period of a year for cerebrovascular, pelvic/peripheral vascular, and cardiovascular procedures showed a decrease of 12%, 20%, and 14%, respectively. The decrease was mainly due to hardware/software upgrades and new low-dose imaging protocols, and partially due to ongoing systematic radiation safety education of the clinical staff. The CAK was in excess of 3 Gy for 15 procedures, and exceeded 5 Gy for 3 procedures. The dose indices have also shown a significant dependence on patient weight for cardiovascular and pelvic/peripheral vascular procedures; a 10 kg shift in mean patient weight can result in a dose index increase of 25%. Conclusion: Automatic monitoring of accumulated dose indices can be utilized to notify the clinical staff and medical physicists when the dose index has exceeded a predetermined action level. This allows for convenient and systematic follow-up of patients in risk of developing deterministic skin injuries. Furthermore, trend analyses of dose indices over time is a valuable resource for the identification of potential positive or negative effects (dose increase/decrease) from changes in hardware, software, and clinical work habits.