Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOMELAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Enhancing Acoustic Signal Quality by Rapidly Switching between Pulse-Echo and Through Transmission using Diplexers

This presentation is for submission to the SPIE Smart Structures/NDE Symposium, the internationally recognized forum for reporting state-of-the-art research and development in smart structures, smart materials, nondestructive evaluation, and health monitoring. Specifically, this paper is being presented in the NDE Symposia in a Conference entitled, "Nondestructive Characterization for Composite Materials, Aerospace Engineering, Civil Infrastructure, and Homeland Security II", in San Diego, CA., March 9-13, 2008.

36 MATERIALS SCIENCE↗

Prompt Neutron Multiplicity Measurements with Portable Detectors

Mobile detection of kilogram quantities of special nuclear materials (SNM) during maritime transportation is a challenging problem for the U.S. Department of Homeland Security. Counting neutrons emitted by the SNM and partitioning them from background neutrons of multiple origins is the most effective passive means of detecting the SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment is complex due to the presence of spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. This work studied the possibilities of building a prototype neutron detector using boron- 10 (10B) as the converter in a novel form factor called “straws” that would address the above problem by examining multiplicity distributions of neutrons originating from a fissioning source. Currently, commercially manufactured fission meters (FM) are available that separate cosmic neutrons from non-cosmic neutrons and quantitatively determine the strength of a fissioning source; however, these FMs use 3He, which is becoming increasingly difficult to procure; also the size and weight of a commercial FM is not conducive to manual neutron detection operations in a maritime environment. The current project may provide a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to the FM. The prototype detector provides a large-area, efficient, lightweight, more granular neutron responsive detection surface (to facilitate imaging) to ease the application of the new FMs. A novel prototype fission meter is being designed at National Security Technologies, LLC, using a thin uniform coating of 10B as neutron converter (only 1 micron thick) inside a large array of thin (4 mm diameter) copper tubes. The copper tubes are only 2-mil thick, and each holds the stretched anode wire under tension and high voltage. The tubes are filled with proportional counter gas (a mixture of 90% Ar and 10% CO2). The tubes operate in proportional counter mode and attract mobile charged particles (alpha-particles) created in the nuclear interaction 10B(n, a)7Li. Several MCNPX calculations covering the substantial design parameter space of neutron multiplicity detectors have been performed and are presented. Our detector’s thermal neutron detection efficiency is compared to two Ortec commercial products, the Fission Meter and Detective-EX. Pulse height spectra originating from the charged particles created in the nuclear reaction 10B(n, a) 7Li* + 2.310 MeV (94%) – excited state (1) and 10B(n, a) 7Li + 2.792 MeV (6%) – ground state (2) are examined, and the response to incident gamma rays are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current Trends in Gamma Radiation Detection for Radiological Emergency Response

Passive and active detection of gamma rays from shielded radioactive materials, including special nuclear materials, is an important task for any radiological emergency response organization. This article reports on the current trends and status of gamma radiation detection objectives and measurement techniques as applied to nonproliferation and radiological emergencies. In recent years, since the establishment of the Domestic Nuclear Detection Office by the Department of Homeland Security, a tremendous amount of progress has been made in detection materials (scintillators, semiconductors), imaging techniques (Compton imaging, use of active masking and hybrid imaging), data acquisition systems with digital signal processing, field programmable gate arrays and embedded isotopic analysis software (viz. gamma detector response and analysis software [GADRAS]1), fast template matching, and data fusion (merging radiological data with geo-referenced maps, digital imagery to provide better situational awareness). In this stride to progress, a significant amount of interdisciplinary research and development has taken place–techniques and spin-offs from medical science (such as x-ray radiography and tomography), materials engineering (systematic planned studies on scintillators to optimize several qualities of a good scintillator, nanoparticle applications, quantum dots, and photonic crystals, just to name a few). No trend analysis of radiation detection systems would be complete without mentioning the unprecedented strategic position taken by the National Nuclear Security Administration (NNSA) to deter, detect, and interdict illicit trafficking in nuclear and other radioactive materials across international borders and through the global maritime transportation–the so-called second line of defense.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Results from an Investigation into Nanostructured Nuclear Radiation Detectors for Non-Proliferation Applications

In recent years, the concept of embedding composite scintillators consisting of nanosized inorganic crystals in an organic matrix has been actively pursued. Nanocomposite detectors have the potential to meet many of the homeland security, non-proliferation, and border and cargo-screening needs of the nation and, by virtue of their superior nuclear identification capability over plastic, at roughly the same cost as plastic, have the potential to replace all plastic detectors. Nanocomposites clearly have the potential of being a gamma ray detection material that would be sensitive yet less expensive and easier to produce on a large scale than growing large, whole crystals of similar sensitivity. These detectors would have a broad energy range and a sufficient energy resolution to perform isotopic identification. The material can also be fabricated on an industrial scale, further reducing cost. This investigation focused on designing and fabricating prototype core/shell and quantum dot (QD) detectors. Fourteen core/shell and four QD detectors, all with the basic consistency of a mixture of nanoparticles in a polymer matrix with different densities of nanoparticles, were prepared. Nanoparticles with sizes <10 nm were fabricated, embedded in a polystyrene matrix, and the resultant scintillators’ radiation detector properties were characterized. This work also attempted to extend the gamma energy response on both low- and high-energy regimes by demonstrating the ability to detect low-energy and high-energy gamma rays. Preliminary results of this investigation are consistent with a significant response of these materials to nuclear radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-I-03: Tissue Equivalent Material Phantom to Test and Optimize Coherent Scatter Imaging for Tumor Classification

Purpose: To accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Methods: A breast phantom has been designed to assess the capability of coded aperture coherent x-ray scatter imaging system to classify different types of breast tissue (adipose, fibroglandular, tumor). The tissue-equivalent phantom was modeled as a hollow plastic cylinder containing multiple cylindrical and spherical inserts that can be positioned, rearranged, or removed to model different breast geometries. Each enclosure can be filled with a tissue-equivalent material and excised human tumors. In this study, beef and lard, placed inside 2-mm diameter plastic Nalgene containers, were used as surrogates for fibroglandular and adipose tissue, respectively. The phantom was imaged at 125 kVp, 40 mA for 10 seconds each with a 1-mm pencil beam. The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor, or momentum transfer (q) spectrum of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: The tissue equivalent phantom was found to accurately model different types of breast tissue by qualitatively comparing our measured form factors to those of adipose and fibroglandular tissue from literature. Our imaging system has been able to define the location and composition of the various materials in the phantom. Conclusion: This work introduces a new tissue equivalent phantom for testing and optimization of our coherent scatter imaging system for material classification. In future studies, the phantom will enable the use of a variety of materials including excised human tissue specimens in evaluating and optimizing our imaging system using pencil- and fan-beam geometries. United States Department of Homeland Security Duke University Medical Center - Department of Radiology Carl E Ravin Advanced Imaging Laboratories Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

Akatosh: Automated Cyber Incident Verification and Impact Analysis

Akatosh, a U.S. Department of Homeland Security Transition to Practice Program (TTP) project developed by Oak Ridge National Laboratory with industry and academic partnership, enables automated, real-time forensic analysis of endpoints after malware-attacks and other cyber security incidents by automatically maintaining detailed snapshots of host-level activity on endpoints over time. It achieves this by integrating intrusion detection systems (IDS) with forensic tools. The combination allows Akatosh to collect vast amounts of endpoint data and assists in verifying, tracking, and analyzing endpoints in real time. This provides operations personnel and analysts as well as managers and executives with continuous feedback on the impact of malicious software and other security incidents on endpoints in their network.

Smith, Jared M.↗

Analyzing Infrastructure Interdependencies Using Network-Of-Networks Modeling

Infrastructure networks play a crucial role in our day-to-day lives, and modeling these infrastructure networks can help decisionmakers prepare for and respond to disruptions such as natural disasters or cyberattacks. Because these infrastructure networks depend on each other, it is not sufficient to model a single network in isolation. We build on previous single-network-modeling techniques to develop a methodology for modeling infrastructure interdependencies as a Network-of-Networks. Using distributionlevel data from a real U.S. city on the power grid, road geometry, and hospital locations, we show how to apply this methodology to modeling three of the U.S. Department of Homeland Security's Critical Infrastructure Sectors: Healthcare, Transportation, and Energy. We also analyze three primary metrics before and after a simulated disaster: 1) impact on hospital access; 2) road network impact with the change in betweenness centrality; 3) electric customer outage. We simulate three different disruptions: 1) road flooding from nearby rivers; 2) a malicious actor targeting the road networks; 3) a malicious actor targeting the electric grid. Finally, we discuss how our methodology can be applied to additional infrastructure networks and types of disruption, and how Artificial Intelligence (AI) techniques may be incorporated into this methodology for further research.

Scherrer, Evan [Drake University, Iowa]↗

Scalable Reasoning System (SRS)

SRS is a web-based and mobile toolkit for information visualization and collaboration. It includes server-side components in the form of web services that provide analytical functions such as data clustering and temporal analysis. The SRS client is accessed via a web browser and uses asynchronous javascript and XML (AJAX) to interact with and visualize the results of these web services. Users of SRS can query data sources that are connected to the SRS backend, and query results are presented in the form of coordinated visual displays in a web browser that depict temporal, topical, and spatial relationships in the results. SRS also includes an early stage graphical reasoning diagram interface that helps analysts express and test hypotheses. This software was developed with funding from the Science and Technology Directorate of the U.S. Department of Homeland Security.

Pike, William↗

Editorial

To address the need for additional high-resolution urban dispersion data sets, the U.S. Departments of Defense, Energy and Homeland Security joined together to fund the Joint Urban 2003 (JU03) atmospheric dispersion study. This major urban study was conducted from June 28 through July 31, 2003, in Oklahoma City, Oklahoma, with the participation of over 150 scientists and engineers from over 20 U.S. and foreign institutions. Through mid-2006 over 125 papers and presentations have been given on scientific findings and model evaluations based on the field study results. The official JU03 data archive is accessible through the internet by requesting an account at https://ju2003-dpg.dpg.army.mil/. The JU03 study included several integrated scientific components necessary to describe and understand the physical processes governing dispersion within and surrounding an urban area and into and within building environments. These components included characterizing: 1) the urban boundary layer; 2) flows within a street canyon, including the effects of traffic on turbulence; 3) flows within and downwind of the tall-building core; 4) the surface energy balance within an urban area; 5) dispersion of tracer into, out of, and within buildings; and 6) dispersion of tracer throughout the downtown core and out to four kilometers downwind from the release. The scientific elements of the study were accomplished using state-of-the-art meteorological and tracer instruments, including lidars, sodars, radars, sonic anemometers, airplane-based meteorological sensors, fast-response tracer analyzers, and helicopter-based remote tracer detectors. Winds and other meteorological quantities were measured continuously at nearly 100 locations in and around downtown OKC. Tracer was released on 10 days during the experiment period and included both puff and continuous releases. The tracer was sampled using over 200 integrated samplers and 25 fast response analyzers. Vertical measurements of tracer were made by placing samplers on the tops of nearly 20 buildings and by sampling tracer at seven levels on a 90-m crane. The twelve papers in this special issue provide a cross-section of the scientific investigations pursued using JU03 data. Half the papers focus on using observations to characterize winds, turbulence and dispersion in the boundary layer above the city and into a downtown Oklahoma City street canyon (Park Avenue). The remaining papers discuss model evaluations using JU03 data and our improved understanding of processes governing dispersion in urban areas using models and observations. The combination of a dense network of measurements with state-of-the-art instruments allowed for an unparalleled investigation of transport and diffusion in an urban environment. We expect the Joint Urban 2003 data set will be used for many years for model development and validation efforts, and for refining our understanding of flow and dispersion in urban areas including the exchange of contaminants between outdoor and indoor and environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comparison of Cs-137 γ Rays and 320-kV X-Rays in a Mouse Bone Marrow Transplantation Model

US homeland security concerns regarding the potential misuse of some radiation sources used in radiobiological research, for example, cesium-137 ( 137 Cs), have resulted in recommendations by the National Research Council to conduct studies into replacing these sources with suitable X-ray instruments. The objective of this research is to compare the effectiveness of an X-RAD 320 irradiator (PXINC 2010) with a 137 Cs irradiator (Gammacell-1000 Unit) using an established bone marrow chimeric model. Using measured radiation doses for each instrument, we characterized the dose–response relationships for bone marrow and splenocyte ablation, using a cytotoxicity-hazard model. Our results show that the X-RAD 320 photon energy spectrum was suitable for ablating bone marrow at the 3 exposure levels used, similar to that of 137 Cs photons. However, the 320-kV X-rays were not as effective as the much higher energy γ rays at depleting mouse splenocytes. Furthermore, the 3 X-ray levels used were less effective than the higher energy γ rays in allowing the successful engraftment of donor bone marrow, potentially as a result of the incomplete depletion of the spleen cells. More defined studies are warranted for determining whether bone marrow transplantation in mice can be successfully achieved using 320-kV X-rays. A higher X-ray dose then used is likely needed for transplantation success.

320-kV X-rays↗

Modeling Cell Survival Fraction and Other Dose-Response Relationships for Immunodeficient C.B-17 SCID Mice Exposed to 320-kV X Rays

US homeland security concerns related to potential misuse of γ-ray-emitting radiation sources employed in radiobiological research (eg, shielded cesium-137 irradiators) led to recommendations by the National Research Council to conduct studies into possibly replacing γ-ray irradiators used in research involving small rodent and other models with X-ray instruments. A limiting factor is suitability of the X-ray photon energy spectra. The objective of our research was to demonstrate the suitability of the radiation energy spectrum of 320-kV X rays after filtration (HVL = 4 mm Cu) for in-vivo cytotoxicity studies in immunodeficient C.B-17 SCID mice. By using a previously-published Hazard Function (HF) model to characterize dose-response relationships for in vivo bone marrow and spleen cell survival fractions and also to characterize the acute lethality risk (hematopoietic syndrome mode) we demonstrate that the filtered 320-kV X-ray beam appears suitable for such studies. A key finding for C.B-17 SCID mice when compared to results previously obtained for immunocompetent C.B-17 mice is that the immunodeficient mice appear to be more radioresistant, implicating a possible role of the immune system capacity in radiosensitivity of mammals.

Scott, Bobby R.↗

Neutron multiplicity counting: Confidence intervals for reconstruction parameters

From nuclear materials accountability to homeland security, the need for improved nuclear material detection, assay, and authentication has grown over the past decades. Starting in the 1940s, neutron multiplicity counting techniques have enabled quantitative evaluation of masses and multiplications of fissile materials. In this paper, we propose a new method to compute uncertainties on these parameters using a model-based sequential Bayesian processor, resulting in credible regions in the fissile material mass and multiplication space. These uncertainties will enable us to evaluate quantitatively proposed improvements to the theoretical fission chain model. Additionally, because the processor can calculate uncertainties in real time, it is a useful tool in applications such as portal monitoring: monitoring can stop as soon as a preset confidence of non-threat is reached.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stochastic analog neutron transport with TRIPOLI-4 and FREYA: Bayesian uncertainty quantification for neutron multiplicity counting

From nuclear safeguards to homeland security applications, the need for the better modeling of nuclear interactions has grown over the past decades. Current Monte Carlo radiation transport codes compute average quantities with great accuracy and performance; however, performance and averaging come at the price of limited interaction-by-interaction modeling. These codes often lack the capability of modeling interactions exactly: for a given collision, energy is not conserved, energies of emitted particles are uncorrelated, and multiplicities of prompt fission neutrons and photons are uncorrelated. Many modern applications require more exclusive quantities than averages, such as the fluctuations in certain observables (e.g., the neutron multiplicity) and correlations between neutrons and photons. In an effort to meet this need, the radiation transport Monte Carlo code TRIPOLI-4® was modified to provide a specific mode that models nuclear interactions in a full analog way, replicating as much as possible the underlying physical process. Furthermore, the computational model FREYA (Fission Reaction Event Yield Algorithm) was coupled with TRIPOLI-4 to model complete fission events. As a result, FREYA automatically includes fluctuations as well as correlations resulting from conservation of energy and momentum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RadTrac : A system for detecting, localizing, and tracking radioactive sources in real time.

Within the homeland security and emergency response communities, there is a need for a low-profile system to detect and locate radioactive sources. RadTrac has been developed at Argonne National Laboratory as an integrated system for the detection, localization, identification, and tracking of radioactive sources in real time. The system is based on a network of radiation detectors and advanced signal-processing algorithms. Features include video surveillance, automated tracking, easy setup, and logging of all data and images. This paper describes the advanced algorithms that were developed and implemented for source detection, localization, and tracking in real time. In the physio-spatial integration approach to source localization, counts from multiple detectors are processed according to the underlying physics linking these counts to obtain the probability that a source is present at any point in space. This information is depicted in a probability density function map. This type of depiction allows the results to be presented in a simple, easy-to-understand manner. It also allows for many different complicated factors to be accounted for in a single image as each factor is computed as a probability density in space. These factors include spatial limitations, variable shielding, directional detectors, moving detectors, and different detector sizes and orientations. The utility and versatility of this approach is described in further detail. Advanced signal-processing algorithms have also been incorporated to improve real-time tracking and to increase signal-to-noise ratios including temporal linking and energy binning. Measurements aimed at demonstrating the sensitivity improvements through the use of advanced signal-processing techniques were performed and are presented. Results of tracking weak sources (<100 {micro}Ci {sup 137}Cs) using four fixed-position detectors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near-complete extraction of maximum stored energy from large-core fibers using coherent pulse stacking amplification of femtosecond pulses

High field science relies on ultrashort pulse lasers with multi-joule pulse energies for studying light–matter interactions under extreme conditions and for driving particle accelerators and secondary radiation sources of x rays, gamma rays, neutrons, positrons, muons, and protons. Next-generation laser drivers will require a 10 3 -10 4 times increase in pulse repetition rates, producing multi-joule energies at multi-kilowatt average powers to enable practical applications in nuclear engineering, advanced materials, medicine, biology, homeland security, and high-energy physics. Spatially coherently combined femtosecond fiber lasers are recognized as a pathway to these next-generation drivers, with significant practical advantages including high efficiency and the possibility of compact integration. However, chirped pulse amplification in fibers is capable of extracting only a small fraction (usually ~1%) of the maximum stored energy. Here we demonstrate near-complete maximum stored energy extraction with low accumulated nonlinearity from a large-core fiber amplifier using coherent pulse stacking amplification. We have amplified a 81-pulse stacking burst in a 85 µm core chirally coupled core Yb-doped fiber, extracting up to 9.5 mJ (~90% of stored energy) with < 4.5 radians of accumulated nonlinear phase, temporally combined this burst into a single pulse, and achieved 4.2 mJ pulses of 313 fs bandwidth-limited duration after compression. This represents, to our knowledge, the highest energy extracted and compressed into a femtosecond pulse from a single fiber amplifier, enabling approximately two orders of magnitude size reduction of future high-energy coherently spatially combined fiber laser arrays.

47 OTHER INSTRUMENTATION↗

Defining resilience within a risk-informed assessment framework

The concept of resilience is the subject of considerable discussion in academic, business, and governmental circles. The United States Department of Homeland Security for one has emphasised the need to consider resilience in safeguarding critical infrastructure and key resources. The concept of resilience is complex, multidimensional, and defined differently by different stakeholders. The authors contend that there is a benefit in moving from discussing resilience as an abstraction to defining resilience as a measurable characteristic of a system. This paper proposes defining resilience measures using elements of a traditional risk assessment framework to help clarify the concept of resilience and as a way to provide non-traditional risk information. The authors show various, diverse dimensions of resilience can be quantitatively defined in a common risk assessment framework based on the concept of loss of service. This allows the comparison of options for improving the resilience of infrastructure and presents a means to perform cost-benefit analysis. This paper discusses definitions and key aspects of resilience, presents equations for the risk of loss of infrastructure function that incorporate four key aspects of resilience that could prevent or mitigate that loss, describes proposed resilience factor definitions based on those risk impacts, and provides an example that illustrates how resilience factors would be calculated using a hypothetical scenario.

99 GENERAL AND MISCELLANEOUS↗