Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Substation-Level Grid Topology Optimization Using Bus Splitting: Preprint

Operations of substation circuit breakers are of high significance for performing system maintenance and topology optimization. Bus splitting is one type of topology changes where the two bus-bars at a substation become electrically disconnected after certain actions of circuit breakers. As these events involve detailed substation modeling, they are not typically considered in power system routine operation and control. In this paper, an improved substation-level topology optimization is developed by expanding traditional line switching with breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bi-linear terms in the resultant topology optimization model. Thus, a tractable mixed-integer linear program formulation is presented which can be efficiently solved for real-time control. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the performance and economic benefits of the proposed topology optimization approach.

bus split↗

Total Effective Dose from Radiologic Emissions from INL Facilities for Calculation of Population Dose for the INL 2024 Annual Site Environmental Report

Total effective radiation dose from airborne releases was calculated using air dispersion modeling performed by the National Oceanic and Atmospheric Administration (NOAA) Idaho Falls Office using their HYSPLIT computer model (Stein et al. 2015; Draxler et al. 2013), and the Dose Multi-Media (DOSEMM) dose assessment model (Rood 2019) . The objective of these calculations was to provide a grid of total effective dose across a model domain that encompasses a 50-mile (80-km) radius from any Idaho National Laboratory (INL) Site source. In addition to INL Site sources, releases from the Radiological and Environmental Sciences Laboratory (RESL) (IF-683) and IF-603 located at the INL Research Center (IRC) within the Idaho Falls city limits were also included. Due to tracking limitations, radionuclides released from IF-611 and IF-603 are modeled as released from IF-603. The dose results will be combined with GIS software to compute a total population dose for the calendar year (CY) 2024 and will be reported in the INL Annual Site Environmental Report (ASER). This report does not cover the population dose calculation and only documents generation of the gridded dose file.

42 - ENGINEERING↗

Generator Scorecard

Code built on Archive Walker. The Generator Scorecard analyzes power grid measurements to automate the process of evaluating the performance of generators. The tool includes three aspects: frequency response, voltage response, and voltage schedule tracking.

Follum, Jim↗

Impact of LWR assembly structural features on cladding burst behavior under LOCA conditions

This provides an initial scoping study on clad balloon and burst behavior for burnup extension of reactor fuel. The associated issues with burnup extension are fuel fragmentation, relocation, and dispersal in the event of cladding failure. The general finding of this work is that the structural features, spacer grids and mixing vanes, locally suppress cladding deformation but have little impact on the overall clad performance during loss-of-coolant accidents. The work detailed in a previous report by Capps et al. focused on core optimization via neutronics, thermal hydraulics and thermomechanical analysis for burnups beyond 62 GWD/tU and enrichments above 5%. Uncertainty of fuel fragmentation relocation and dispersal in high-burnup rods during accident conditions was also investigated. The dispersal aspect of fuel fragmentation depends on cladding rupture. Thus, assessing uncertainties in the rupture behavior is helpful in estimating the dispersal of high-burnup fuel. This study builds on the previous work by assessing the impact of assembly structural features on cladding balloon and burst behavior in a full-length fuel rod. In this work, the BISON fuel performance code was used to generate 2D radial and height meshes containing structural features commonly used in nuclear fuel assemblies. First, meshes were generated with spacer grids. Results were then compared to the cladding burst temperature and balloon strain results from the previous work. A mesh sensitivity study was performed to ensure that mixing vanes and spacer grid effects were appropriately considered, resulting in a more refined mesh than the previous study. The balloon deformation and burst times of the cladding were compared to the original case. Consideration was also given to the effect of rod initial pressure. In conclusion, 3D quarter rod simulations were also performed and found good agreement with the 2D simulations in clad deformation and reasonable agreement in burst times.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Small Hydropower Interconnections: Best Practices

Small hydropower projects have been the predominant source of capacity growth of U.S. hydropower for more than a decade, and they present the most cost-effective and environmentally permissible avenues for hydropower growth (DOE 2016; Johnson et al. 2018). However, interconnection to electricity distribution and transmission grids is a persistent barrier due to cost surprises and schedule overruns. As a culmination to research into the status and requirements of small hydropower interconnection across the United States, this paper presents the best practices for setting interconnection standards that can improve the process for small hydropower developers. As part of the analysis, the interconnection costs are compared between small hydropower, solar, and wind. The analysis of the small hydropower interconnection landscape across the United States was carried out by Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) with support from the U.S. Department of Energy Water Power Technologies Office. The research team was guided by a Technical Advisory Group (TAG) and gleaned data from publicly available sources, such as the HydroSource database (ORNL 2020) and interconnection queues hosted by utilities, balancing authorities, independent system operators (ISOs), and regional transmission organizations (RTOs). The results of this work are shared in a series of papers detailing the state of small hydropower in the United States (“Small Hydropower Interconnections: Small Hydropower in the United States”), the variety of state interconnection processes to connect power generators with the grid (“Small Hydropower Interconnections: State Interconnection Processes”), and an analysis of the interconnection processes (“Small Hydropower Interconnections: Analysis of Interconnection Processes”). In this, the final paper in the series, best practices for interconnection processes (“Small Hydropower Interconnections: Best Practices”) are identified from the solar energy and distributed wind energy industries that are transferrable to small hydropower development. This information will help overcome barriers to future small hydropower development.

13 HYDRO ENERGY↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Opportunities and Challenges to Capturing Distributed Battery Value via Retail Utility Rates and Programs

Distributed battery deployment is increasing with advanced metering, control, and communication technologies, leaving electric utilities with an under-utilized, flexible grid resource in aggregate. Rates can reflect locational and temporal prices while utility incentive-based programs allow DERs to provide direct grid services. However, utilities must balance accurately reflecting dynamic grid conditions versus simple and feasible design that encourages customer participation. Currently, most rates and incentive-based programs are simple, but as penetration of DER and advanced controls increase, dynamic designs could become prevalent. Utilities could encourage providing multiple services to optimize distributed battery dispatch and value streams, however, challenges persist when stacking services across distribution and bulk systems. A DER committed to multiple discrete services concurrently necessitates coordination between operators and a clear hierarchy of commitments. One way to address this is to separate commitments by time or capacity. For services that follow cyclic, predictable patterns, or those that are peak driven with predictability, an operator could ensure sufficient state of charge for participation, leaving time where a distributed battery could otherwise provide different services by segmenting participation temporally. To provide continuous or unexpected services, a battery operator may use state of charge management to reserve some percentage of the battery and segment participation by capacity. Macroeconomic trends, load patterns, generation profiles, and grid configurations drive variation in value and the subsequent implications for utility offerings and how a customer might participate. As distributed battery adoption increases, both regulators and utilities will need to ensure no adverse grid impacts and encourage provision of societal value beyond the customer domain.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic Analysis of a Novel Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage: Preprint

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The integration of renewable power and storage to support future carbon-free utility has several significant and positive impacts including expanding the renewable generation into the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Can a Coating Mitigate Molten Na Dendrite Growth in NaSICON Under High Current Density?

Alkali metals are among the most desirable negative electrodes for long duration energy storage due to their extremely high capacities. Currently, only high-temperature (>250 °C) batteries have successfully used alkali electrodes in commercial applications, due to limitations imposed by solid electrolytes, such as low conductivity at moderate temperatures and susceptibility to dendrites. Toward enabling the next generation of grid-scale, long duration batteries, we aim to develop molten sodium (Na) systems that operate with commercially attractive performance metrics including high current density (>100 mA cm –2 ), low temperature (<200 °C), and long discharge times (>12 h). In this work, we focus on the performance of NaSICON solid electrolytes in sodium symmetric cells at 110 °C. Specifically, we use a tin (Sn) coating on NaSICON to reduce interfacial resistance by a factor of 10, enabling molten Na symmetric cell operation with “discharge” durations up to 23 h at 100 mA cm –2 and 110 °C. Unidirectional galvanostatic testing shows a 70% overpotential reduction, and electrochemical impedance spectroscopy (EIS) highlights the reduction in interfacial resistance due to the Sn coating. Detailed scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) show that Sn-coated NaSICON enables current densities of up to 500 mA cm –2 at 110 °C by suppressing dendrite formation at the plating interface (Mode I). In conclusion, this analysis also provides a mechanistic understanding of dendrite formation at current densities up to 1000 mA cm –2 , highlighting the importance of effective coatings that will enable advanced battery technologies for long-term energy storage.

25 ENERGY STORAGE↗

Hybrid renewable energy systems

In the pursuit of ecologically sustainable and resilient energy systems, increasingly more attention is being devoted to a diversity of energy generation and storage methods. As the landscape of generation technology gains nuance and complexity, a wide-ranging set of technical questions has emerged, touching on topics that range from control and optimization of hybrid systems to finance and economic viability to multi-fidelity modeling and scientific machine learning. In the context of this special issue, hybrid renewable energy systems are any systems that consider the combined dynamics of more than one form of generation, storage, or grid subsystem. Research endeavors have delved into improving the flexibility of energy systems by utilizing existing resources, introducing novel operational strategies, deploying enhanced renewable forecasts, and exploring emerging technologies. In conclusion, the interconnection among various sectors has garnered heightened attention, not only due to the provision of additional tradable energy products but also for furnishing flexible headroom to system operators.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Engineering Li/Na selectivity in 12-Crown-4–functionalized polymer membranes

Significance Lithium is a key ingredient in batteries, which are integral components of next-generation automobiles, airplanes, grid energy storage, and electronic devices. Unfortunately, lithium extraction from natural sources is laborious, slow, and costly, motivating the search for more efficient isolation techniques. While polymeric membranes could reduce the cost of lithium recovery, current membrane materials lack sufficient lithium-ion selectivity. To address this challenge, we introduce a class of polymeric membranes that incorporate ion binding sites, which significantly increases the transport selectivity of LiCl over NaCl. These studies provide guidelines and practical considerations for incorporating specific interactants into polymers that mediate selective ion transport.

36 MATERIALS SCIENCE↗

Energy Storage Market Transformation Through Stored Energy Targets

Aggressive energy decarbonization targets will require the rapid deployment of renewable energy in the U.S. in coming years. As the amount of variable generation on the grid grows, there will be an increasing need for long-duration energy storage (LDES) technologies to maintain grid reliability. Meeting that need will require a suite of technology alternatives with different capabilities. Many of these alternatives, however, are in a nascent state and face significant commercialization challenges. In the last decade, 10 U.S. states have enacted energy storage mandates as a vehicle for market transformation to accommodate energy storage. Those mandates, however, fail to send appropriate investment signals for LDES technologies because they are based on energy storage capacity and treat all technologies the same, regardless of duration. This paper explores the idea of replacing capacity-based storage procurement targets with stored energy targets, which would be technology-neutral policies designed to enable the market transformation necessary to support a competitive LDES industry.

Twitchell, Jeremy B.↗

Self-Secure Inverters Against Malicious Setpoints

The next generation of grid-interactive inverters brings a communication feature that allows data sharing from utility supervisory controllers and smart devices that are connected to the same network. This feature enhances the control capabilities of grid-interactive inverters to provide services beyond active power injection. However, communication networks entail more vulnerable surfaces to malicious attacks that may result in modifying active and reactive power setpoints and causing weak-grid conditions or abnormal inverter operation. In this paper, steady-state and the dynamic behavior of the inverter for the incoming setpoints are analyzed to detect false data injection attacks and provide device-level security. The steady-state behavior of the inverter in the operating region is determined from the grid parameters such as the grid voltage and the grid impedance. These estimations are accomplished by the proposed self-security technique through a low-frequency signal injection-based approach combined with the recursive least square method. Moreover, a reduced fourth-order inverter model is used as the dynamic reference model, and grid parameters as well as the incoming setpoints are implemented to the reference model to verify whether the dynamic behavior of the inverter is inside the permissible region of operation. The validity and performance of the proposed method are verified experimentally through Allen-Bradley Powerflex 755 three-phase inverter and a 12 kW NHR 9410 regenerative power grid emulator. The results show that the self-secure smart-inverter is able to accept or reject the incoming commands and thus is protected from malicious cyber-physical attacks.

Hossen, Tareq↗

Hy-DAT: A Tool to Address Hydropower Modeling Gaps Using Interdependency, Efficiency Curves, and Unit Dispatch Models

As the power system continues to be flooded with intermittent resources, it becomes more important to accurately assess the role of hydro and its impact on the power grid. While hydropower generation has been studied for decades, dependency of power generation on water availability and constraints in hydro operation are not well represented in power system models used in the planning and operation of large-scale interconnection studies. There are still multiple modeling gaps that need to be addressed; if not, they can lead to inaccurate operation and planning reliability studies, and consequently to unintentional load shedding or even blackouts. As a result, it is very important thathydropower is represented correctly in both steady-state and dynamic power system studies. In this paper, we discuss the development and use of the Hydrological Dispatch and Analysis Tool (Hy-DAT) as an interactive graphical user interface (GUI), that uses a novel methodology to address the hydropower modeling gaps like water availability and inter-dependency using a database, and algorithms, to generate accurate representative models for power system simulation.

Wang, Dewei↗

Multi-Resolution UAV Path Replanning for Inspection of Tailings Dams

Autonomous inspection of large and complex structures with a commercial unmanned aerial vehicle (UAV) is a challenging problem that has been addressed in recent years. In this paper, we address the global motion planning problem of creating autonomous inspection missions for UAVs considering photogrammetry constraints. We focus on the inspection of large tailings dams, which are dam structures used to store waste byproducts of mining. Our method uses a prior sparse point cloud of the dam to generate a voxel grid, where paths satisfying photogrammetry constraints are tested for collisions. We then apply the A* algorithm as a local planner to avoid obstacles within the global mission. Moreover, we address the problem of changing routes online by using octree-based multi-resolution grids for efficient and fast pathfinding. Our results, obtained using tridimensional maps of an actual coal mine tailings dam, show that using octrees for multi-resolution motion planning is faster than using a fixed voxel grid in online missions while inspecting large structures.

42 ENGINEERING↗